Gasboy MS7120 User Manual

Introduction

Purpose

This document contains a verification sequence that allows you to determine whether your scanner is configured correctly, and a programming sequence to follow if it is not configured correctly.
Be aware of the following:
Metrologic® MS7120 Bar Code Scanner Setup
January 2007
IMPORTANT INFORMATION
• Refer to MDE-4389 Setting Up Datalogic™ DLL2020 Bar Code Scanner Used on Profit Point Terminal for Datalogic DLL2020 scanners.
• Refer to MDE-4354 Setting Up Metrologic Metrologic MS6720 scanners.
®
MS6720 Bar Code Scanner for
MDE-4631
Note: Your bar code scanner has been programmed with default settings at the factory and

Table of Contents

Top ic Page
Introduction 1
Important Safety Information 3
Setting Up the Scanner 5
Programming a Sequence 7
Bar Codes 8
should be ready to be configured.
MDE-4631 Metrologic® MS7120 Bar Code Scanner Setup · January 2007 Page 1
Introduction

Warranty

For information on warranty, refer to MDE-4255 Gasboy’s Warranty Policy Statement. If you have any warranty-related questions, contact Gasboy’s Warranty Department at its Greensboro location.
Page 2 MDE-4631 Metrologic® MS7120 Bar Code Scanner Setup · January 2007

Important Safety Information

This section introduces the hazards and safety precautions associated with installing, inspecting, maintaining or servicing this product. Before performing any task on this product, read this safety information and the applicable sections in this manual, where additional hazards and safety precautions for your task will be found. Fire, explosion, electrical shock or pressure release could occur and cause death or serious injury if these safe service procedures are not followed.
Preliminary Precautions
You are working in a potentially dangerous environment of flammable fuels, vapors, and high voltage or pressures. Only trained or authorized individuals knowledgeable in the related procedures should install, inspect, maintain or service this equipment.
Important Safety Information
Read the Manual
Read, understand and follow this manual and any other labels or related materials supplied with this equipment. If you do not understand a procedure, call a Gasboy Authorized Service Contractor or call the Gasboy Service Center at 1­800-444-5529. It is imperative to your safety and the safety of others to understand the procedures before beginning work.
Follow the Regulations
There is applicable information in NFPA 30A; Automotive and Marine Service Code, NFPA 70; National Electrical Code (NEC),
OSHA regulations and federal, state, and local codes which must be followed. Failure to install, inspect, maintain or service this equipment in accordance with these codes, regulations and standards may lead to legal citations with penalties or affect the safe use and operation of the equipment.
Emergency Total Electrical Shut-Off
The first and most important information you must know is how to stop all fuel flow to the pump and island. Locate the switch or circuit breakers that shut-off all power to all fueling equipment, dispensing devices, and submerged turbine pumps (STPs).
!
WARNING
!
The EMERGENCY STOP, ALL STOP, and PUMP STOP buttons at the cashier’s station WILL NOT shut off electrical power to the pump/dispenser.
Total Electrical Shut-Off Before Access
Any procedure requiring access to electrical components or the electronics of the dispenser requires total electrical shut­off of that unit. Know the function and location of this switch or circuit breaker before inspecting, installing, maintaining, or servicing Gasboy equipment.
Evacuation, Barricading and Shut-Off
Any procedures requiring accessing the pump/dispenser or STPs requires the following three actions:
This means that even if you activate these stops, fuel may continue to flow uncontrolled.
You must use the TOTAL ELECTRICAL SHUT­OFF in the case of an emergency and not only these cashier station “stops.”
Replacement Parts
Use only genuine Gasboy replacement parts and retrofit kits on your pump/dispenser. Using parts other than genuine Gasboy replacement parts could create a safety hazard and violate local regulations.
Safety Symbols and Warning Words
This section provides important information about warning symbols and boxes. Alert Symbol
This safety alert symbol is used in this manual and on warning labels to alert you to a precaution which must be followed to prevent potential personal safety hazards. Obey safety directives that follow this symbol to avoid possible injury or death.
Signal Words
These signal words used in this manual and on warning labels tell you the seriousness of particular safety hazards. The precautions that follow must be followed to prevent death, injury or damage to the equipment
DANGER - This signal word is used to alert you to a
!
hazard to unsafe practice which will result in death or serious injury WARNING - This alerts you to a hazard or unsafe
!
practice that could result in death or serious injury. CAUTION with Alert symbol - This signal word
!
designates a hazard or unsafe practice which may result in minor injury. CAUTION without Alert symbol - When used by itself, CAUTION designates a hazard or unsafe practice which may result in property or equipment damage.
- An evacuation of all unauthorized persons and vehicles using safety tape, cones or barricades to the effected units
- A total electrical shut-off of that unit
MDE-4631 Metrologic® MS7120 Bar Code Scanner Setup · January 2007 Page 3
Working With Fuels and Electrical Energy
Prevent Explosions and Fires
Fuels and their vapors will become explosive if ignited. Spilled or leaking fuels cause vapors. Even filling customer tanks will cause explosive vapors in the vicinity of dispenser or island.
Important Safety Information
No Open Flames
Open flames from matches, lighters, welding torches or other sources can ignite fuels and their vapors.
No Sparks - No Smoking
Sparks from starting vehicles, starting or using power tools, burning cigarettes, cigars or pipes can also ignite fuels and their vapors. Static electricity, including an electrostatic charge on your body, can cause a spark sufficient to ignite fuels and their vapors. After getting out of a vehicle, touch the metal of your vehicle to discharge any electrostatic charge before you approach the dispenser island.
Working Alone
It is highly recommended that someone who is capable of rendering first aid be present during servicing. Be familiar with Cardiopulmonary Resuscitation (CPR) methods if you are working with or around high voltages. This information is available from the American Red Cross. Always advise the station personnel about where you will be working, and caution them not to activate power while you are working on the equipment. Use the OSHA tag out and lock out procedures. If you are not familiar with this requirement, refer to information in the service manual and OSHA documentation.
Working With Electricity Safely
Be sure to use safe and established practices in working with electrical devices. Poorly wired devices may cause a fire, explosion or electrical shock. Be sure grounding connections are properly made. Make sure that sealing devices and compounds are in place. Be sure not to pinch wires when replacing covers. Follow OSHA Lock-Out and Tag-Out requirements. Station employees and service contractors need to understand and comply with this program completely to ensure safety while the equipment is down.
Hazardous Materials
Some materials present inside electronic enclosures may present a health hazard if not handled correctly. Be sure to clean hands after handling equipment. Do not place any equipment in mouth.
!
WARNING
This area contains a chemical known to the State of California to cause cancer.
WARNING
!
This area contains a chemical known to the State of California to cause birth defects or other reproductive harm.
IMPORTANT: Oxygen may be needed at scene if gasoline has been ingested or inhaled. Seek medical advice immediately.
Emergency First Aid
Informing Emergency Personnel
• Compile the following information for emergency personnel:
• Location of accident (for example, address, front/back of building, and so on.)
• Nature of accident (for example, possible heart attack, run over by car, burns, and so on.)
• Age of victim (for example, baby, teenager, middle-age, elderly.)
• Whether or not victim has received first aid (for example, stopped bleeding by pressure, and so on.)
• Whether or not a victim has vomited (for example, if swallowed or inhaled something, and so on.)
WARNING
!
Gasoline ingested may cause unconsciousness and burns to internal organs. Do not induce vomiting. Keep airway open. Oxygen may be needed at scene. Seek medical advice immediately.
WARNING
!
Gasoline inhaled may cause unconsciousness and burns to lips, mouth and lungs. Keep airway open. Seek medical advice immediately.
WARNING
!
Gasoline spilled in eyes may cause burns to eye tissue. Irrigate eyes with water for approximately 15 minutes. Seek medical advice immediately
WARNING
!
Gasoline spilled on skin may cause burns. Wash area thoroughly with clear/water. Seek medical advice immediately.
IMPORTANT: Oxygen may be needed at scene if gasoline has been ingested or inhaled. Seek medical advice immediately.
Lockout/Tagout
Lockout/Tagout covers servicing and maintenance of machines and equipment in which the unexpected energization or start up of the machine(s) or equipment or release of stored energy could cause injury to employees or personnel. Lockout/Tagout applies to all mechanical, hydraulic, chemical or other energy, but does not cover electrical hazards. Reference Subpart S of 29 CFR Part 1910
- Electrical Hazards, 29 CFR Part 1910.333 contains specific Lockout/Tagout provision for electrical hazards.
Page 4 MDE-4631 Metrologic® MS7120 Bar Code Scanner Setup · January 2007

Setting Up the Scanner

To set up the scanner, proceed as follows:
1 Turn off power to the Profit Point Point of Sale (POS) terminal.
2 Unplug the AC power to the POS Distribution Box (D-Box) power supply.
3 Remove the scanner and the Metrologic cable from the shipping box.
Note: None of the other parts in the shipping box, including the scanner power transformer,
will be used with this installation.
4 Insert the phone jack end of the scanner cable into the phone jack connector on the scanner
Figure 1 on page 6).
(
5 Connect the DB9 connector on the scanner cable to the scanner port on the POS D-Box
Figure 1 on page 6).
(
6 Plug in the POS D-Box power supply to the AC outlet (Figure 1 on page 6).
Setting Up the Scanner
7 Turn on the Profit Point POS terminal. Follow the instructions that appear on the screen. The
Profit Point terminal initializes and begins the POS operations.
MDE-4631 Metrologic® MS7120 Bar Code Scanner Setup · January 2007 Page 5
Loading...
+ 9 hidden pages