Gasboy Gascard Credit User Manual

Page 1
Gasboy CFN Series
Gascard
Credit and Debit Card Networks
Version 020
for Site Controller II
Versions 2.3 and above
part number: C35907
Gasboy International LLC
Page 2
Page 3
Gascard
Credit and Debit Card Networks
Version 002
March 12, 2003
C35907
Gasboy International LLC
Lansdale, Pennsylvania
Page 4
Gasboy International LLC
P. O. Box 309
Lansdale, PA 19446
Copyright 2003 by Gasboy International LLC
All rights reserved.
Printed in the United States of America.
The information in this document is confidential and proprietary. No furth er disclosure thereof shall be made without permission from Gasboy International LLC.
Gasboy International LLC believes that the information in this document is accurate and reliable. However, we assume no responsibility for i ts use, nor for any infringements of patents or other rights of third parties resulting from its use. We reserve the right to make changes at any time without notice.
REVISION RECORD OF THIS DOCUMENT
Part No. Date Published SC II Release Levels
C35907 June 1997 Version 2. 2 and above C35907 July 15, 1999 Version 2.2 and abov e C35907 October 25, 1999 Version 2.3 and above C35907 March 12, 2003 Version 2.3 and above
i
Page 5
Site Controller II Related Publications
Site Controller Il - version 2.3 and later
Part No. Title
C09212 SC II Manager’s Manual 2.23 C01918 SC II Installation Manual C09213 SC II Configur ation Manual, version 2 .3 C09159 SC II Pocket Reference, version 2.3 C09204 Check Point Reference Manual C35745 Profit Point Clerk’s Manual - Modular series C35746 Profit Point Reference Manual - Modular series C35923 Point of Sale and Shift Change, version 003
Credit and Debit Card Networks
C35931 Amoco/DataCard C35909 Generic Dial C35901 Buypass C35908 PaymenTech (formerly Gensar) C35902 ADS-CITGO C35910 NaBANCO C35906 ADS-FINA C35911 NDC C35919 ADS-ZION C35913 Sinclair C35904 EDS-CCIS C35914 SPS/Phillips C35903 Comdata C35915 T-Chek C35905 FDR C35916 UFDA C35930 Gasboy Dial C35917 VDOT C35907 Gascard C35918 VisaNet
Forms, Quick Refere nc e, Tutorials
C09134 SC II Configuration Order Form call SC II Sample Reports
Pump Interface
C09146 Pump Interface Manual C01745 Current Loop Interface Unit Manual C35849 SDI/Wayne CAT Interface C35924 SDI/Unitec Interface
Card Encoding and Miscellaneous
C09136 CFN Series Clubcard Format C01687 CFN Series Card Encoding Manual
Remote Communications
C09137 SC II-Host Communications C09138 SC II Raw Mode Communications C09140 Applications Guide for Host-SC Communications C09141 PC/SiteControl User’s Manu al
Technical Publications
internal SC II Technical Manual C01759 CFN Diagnostic Manual
ii
Page 6
Page 7
Credit & Debit Card Ne tworks Gascard 020 iii
Table of Contents
Cards accepted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Preparing for configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Configuring the Site Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
System Parameters (SYS_PAR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Console (CONSOLE) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Island card reader (READER) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Tables (TABLE) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Transaction format (TRFMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Jumper settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
The GASCARD command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
The transaction pointer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Gasboy CFN Series
Page 8
iv Gascard 020 Credi t & De bit Card Networks
Gasboy CFN Series
Page 9
Credit & Debit Card Networks Gascard 020 1
020
If you are connecting your site to Gascard for card verification, use this manual for reference.
The Gascard software now complies with the new VIS A restriction on the credit card account printed on
Island receipts. Only 4 digits wi ll be printed instead of the complete number.
Gascard
Cards accepted
Gascard currently accepts these cred i t cards:
VISA MasterCard American Express Discover
The proprietary cards accepted are:
Gascard Fuelman
Preparing for configuration
Before you configure, you should consu lt with yo ur Gasca rd repr es enta tiv e about the following :
• Whether to allow Gascard to set fuel prices on Gascard transactions.
• What kind of Gascard terminal you should have (Diebol d, or another manufacturer’s; note that the Diebold cannot handle merchandise transactions). Use a M/M 1:1 cable (Gasboy part number C04549) to link the Site Controller to the Gascard terminal.
• To accept Fuelman dual cards, you must have the Fuelman special card handler.
Gasboy CFN Series
Page 10
2 Gascard 020 Credit & Debit Card Networks
Configuring the Site Controller
Your Gasboy authorized service representative will configure your Site Controller. Before the service representative begins, make sure you have collected all the information that will be used for configuration.
System Parameters (SYS_PAR)
This information is provided for reference. The menu programs initialize and/or stores the appropriate values for you in the system parameters.
Club Card formats: field widths - page 2
Digits in PIN for credit: 3
Reader verification - page 4
Use remote verification: credit Use local verification: club Check PIN: none Check mod 10: none Check expiration date: credit (and, optionally, cl ub)
Console verification - page 5
Use remote verification: credit Use local verification: club Check PIN (console): none Check mod 10 (console): none Check expiration date (console): credit (and, op tionally, club)
Serial port configuration - Page 8
Host handler channel: The number of the port used for communicating with the Gascard controller. The
default port # is none.
Host router data: The first character determines whether your site will use the prices in the Gascard terminal
(Y) or ignore those prices (I). The second character determines whether your site will accept merchandise products (N, for non-fuel; remember that the Diebold terminal cannot handle merchandise transactions) or will not accept merchandise products (X).
Host handler baud rate: 4800 Send requests to ho st handler: credit
Host handler data: Two two-digit numbers; the default numbers are 00 and 20.
The first two digits, the poll address, are always 30. The second and third two-di git numbers, which set timeouts, are always 05. The fifteenth two-digit number is 0 if debug output to disk or 1 if debug output to local port. The sixteenth two- digit number is 1 if debug, else 0.
Console (CONSOLE)
Allow hand entry of ca rd data: Yes Console asks for odometer on fuel sale: 1 (Card-encoded) Console asks for auxiliary # on fuel sale: 1 (Card-encoded)
Gasboy CFN Series
Page 11
Credit & Debit Card Networks Gascard 020 3
Island card reader (READER)
The Select Pump step must be before the Verify Card step. In the Enter your PIN step, the number of digits must be set to at least 8, with no auto-enter. In Enter Odometer, the number of digits must be set to no more than 6.
Tables (TABLE)
• The receipt table must have at least 100 entries.
• The router table must have 492 entries.
• The price table must have 50 more entries than usual if you are using Gascard prices.
Transaction format (TRFMT)
Make certain that the transactio n printout form at includes the auth orization number (field type 3) an d dollar amount (field type 11).
Jumper settings
The Gascard interface requires that the Si te Controller be configured for “to DTE.” The “to DTE” jumper settings on K1 or K2 for ports 1 or 3 are:
The GASCARD command
You must execute the command GASCARD to set up the router table.
If you see the messa ge Must run GASCARD.BIN to initialize when the Site Controll e r boots, type
GASCARD at the A* or C* prompt.
The transaction pointer
If you are not regularly polling a nd re sett ing the transac tio n p ointe r, then you should run the PURGE SITE command once a day so you do not fill up the Site Controller’s memory.