Federal Communications Commission
Radio Frequency Interference Statement
This equipment generates, uses and can radiate frequency energy and if not installed and used properly, that is in strict accordance with the manufacturer's instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the
CS14, CSN14 Series Converter Switch Installation and User Guide (02/06)
Contacting GarrettCom, Inc
Please use the mailing address, phone and fax numbers and email address listed below:
GarrettCom, Inc.
47823 Westinghouse Drive
Fremont, CA 94539
CS14, CSN14 Series Converter Switch Installation and User Guide (02/06)
TABLE OF CONTENTS Page
1.0 SPECIFICATIONS ............................................................................... 1
1.1 Technical Specifications..................................................................... 1
1.2 Summary of models and descriptions:.................................................. 11
2.0 INTRODUCTION ............................................................................... 14
2.1 Inspecting the Package and the Product............................................. 14
2.2 Product Description ........................................................................... 15
2.3 Frame Buffering and Latency............................................................ 23
CS14, CSN14 Series Converter Switch Installation and User Guide (02/06)
3.7 CS14H and P Series , DC-powered, Installation .............................. 48
3.8 Connecting Ethernet Media ............................................................... 49
3.8.1 Connecting Twisted Pair............................................................ 51
3.8.2 Connecting Fiber Optic ST-type, “twist-lock”........................... 52
3.8.3 Connecting Fiber Optic SC-type, "Snap-In".............................. 53
3.8.4 Connecting Single-Mode Fiber Optic........................................ 53
3.8.5 Power Budget Calculations for CS14 Series, Fiber Media........ 54
3.8.6 Connections to NICs which support Auto-Neg RJ-45 ports...... 56
CS14, CSN14 Series Converter Switch Installation and User Guide (02/06)
5.4 Shipping and Packaging Information................................................. 68
APPENDIX A: WARRANTY INFORMATION......................................... 69
Revisions Rev A 02/06: Change address to Westinghouse Drive Rev A 05/05: Minor updates on Auto-cross (MDIX) functionality Rev A 10/04: Minor updates on power supply option. Rev A 09/04: Minor updates on UL requirements, and edit.
CS14, CSN14 Series Converter Switches Installation and User Guide (02/06)
1.0 SPECIFICATIONS
1.1 Technical Specifications
Ports Performance
When a port is operating at 100Mbps:
Data Rate: 100Mbps When a port is operating at 10 Mbps: Data Rate: 10 Mbps
CS14, CSN14 Series Converter Switches Installation and User Guide (02/06) Address buffer age-out time: 300 sec.
Packet buffers memory: 128KB, dynamically shared on all domains Latency (not including packet time): 100 to 10 Mbps: 5µs 10 to 100Mbps: 15µs Path Delay Value: 50 BT on all ports
Maximum Ethernet Segment (or Domain) Lengths
10BASE-T (Unshielded twisted pair) - 100 m (328 ft) 100BASE-TX (CAT 5 UTP) - 100 m (328 ft)
CS14, CSN14 Series Converter Switches Installation and User Guide (02/06)
Operating Environment
CS14, CSN14: 32ºF to 104ºF (0ºC to 40ºC) CS14H, CSN14H: -13ºF to 140ºF (-25ºC to 60ºC) Long term per agency tests (UL).
-40ºF to 149ºF (-40ºC to 85ºC) Short term per IEC Type tests. CS14P, CSN14P: -40ºF to 167ºF (-40ºC to 75ºC) Long term per agency tests (UL).
-58ºF to 212ºF (-50ºC to 100ºC) Short term per IEC Type tests.
Storage Temperature
,
All models: -40ºF to 160ºF (-40ºC to 85ºC)
CS14, CSN14 Series Converter Switches Installation and User Guide (02/06)
Packaging:
Enclosure: Rugged sheet metal (Steel). Dimensions of the Switch unit:
3.5 in H x 3.0 in W x 1.0 in D (8.9 cm x 7.6 cm x 2.5 cm)
Weight: all models: 4.6 oz. (130g);
Power supply, –d, and i: 5.9 oz (170g)
–Hd, and Hi: 5.8 oz (165g)
CS14, CSN14 Series Converter Switches Installation and User Guide (02/06)
POWER SUPPLY
These products are intended to be supplied by a Listed, Direct Plug-In power unit, marked “Class 2”, or a Listed ITE Power Supply, marked “LPS”, which has suitably rated output voltage (i.e. 9vdc, 12vdc, 24vdc, 48vdc), and suitably rated output current (i.e. 100mA to 500mA).When connected to a 48 V centralized dc source these products shall be provided with a Listed 5 A DC fuse in the supply circuit.
CS14, CSN14 Series Converter Switches Installation and User Guide (02/06)
International (-i) models. Input: 240vac at 50Hz with IEC 320 connector for the user supplied AC power cord. Output:12vdc, 1Amps
Factory Floor (H) Ratings
(-25 to 60°C)
North America (-Hd) models. Hardened, factory floor temperature rated. Input: 6ft AC
power cord to IEC 320 connector on the 100-240vac 47-63Hz external power adapter. Output:12vdc, 1.25Amps International (-Hi) models. Factory floor temperature rated. Input: IEC 320 connector on
CS14, CSN14 Series Converter Switches Installation and User Guide (02/06)
Direct DC POWER SUPPLY : built-in terminal block for +, -, ground along with 12VDC jack 12V DC internal (range of 8.0 to 15V DC),.
24V DC internal (range of 18 to 36V DC),.
-48V DC internal (range of 36 to 60V DC), , -, ground.
CS14, CSN14 Series Converter Switches Installation and User Guide (02/06)
Port Connectors
:
Two RJ-45 Ports: support 100BASE-TX and 10BASE-T with auto-cross (MDIX). They are shielded 8-pin female connectors for shielded (STP) and unshielded (UTP) Cat 3, 4, 5 cable. One Fiber optic port: On the CSN14 Series it is 10Base-FL with ST connections and on the CS14 series it is 100Base-FX with a “fiber flavor” choice of multimode
CS14, CSN14 Series Converter Switches Installation and User Guide (02/06)
LED Indicators (Dual: front and top)
POWER: Steady ON when power applied
10/100: Steady ON for 100Mbps; OFF for 10 Mbps
LK/ACT: Steady ON for LINK (LK) with no traffic, BLINKING indicates port is transmitting / receiving (ACT).
F/H: Steady ON for full-duplex, OFF for half-duplex
Mounting options
CS14, CSN14 Series Converter Switches Installation and User Guide (02/06)
Agency Approvals and Standards Compliance:
UL Listed (UL 60950), cUL, CE,
Emissions meets FCC Part 15 Class A.
NEBS L3 and ETSI compliant.
H and P models: IEEE P1613 Env. Std for Electric Power Substations P models: NEMA TS-2 and TEES for traffic control equipment P models: designed for UL 2043 above-the-ceiling installation IEC61850 EMC and Operating Conditions Class C Power Substations
CS14, CSN14 Series Converter Switches Installation and User Guide (02/06)
1.2 Summary of models and descriptions:
Note: The CSN14 model # consists of the base unit type and the power input. Insert S for sgl-mode The CS14 model # consists of the base unit type, the fiber flavor (ff) and the power input.
CSN14 Models (for 10Mb fiber). CSN14-d or -i = two 10/100 RJ-45+ one 10Mb ST Fiber port for office and wiring closet, rated (0 to 40°C) using an external AC power supply. CSN14H-Hd, Hi = Hardened (H), two RJ-45+ one 10Mb Fiber port for factory floor, rated (-25 to 60°C) using a direct DC ( 8-15VDC) and/or external AC hardened power supply ( i ncluded). CSN14H-12VDC = Same as CS14H model, except AC hardened power supply is not included
CS14, CSN14 Series Converter Switches Installation and User Guide (02/06)
CS14 Models (for 100Mb fiber).
CS14-ff-d or -i = two 10/100 RJ-45+ one 10Mb ST Fiber port for office and wir i ng closet (0 to 40C) using an external AC power supply. CS14H-ff-Hd, Hi = Hardened (H), two RJ-45+ one 10Mb Fiber port for factory floor (-25 to 60C) using a direct DC ( 8-15VDC) and/or external AC hardened power supply (included). CS14H-ff-12VDC = Same as CS14H model, except AC hardened power supply is not included CS14H-ff-24VDC = Same as CS14H-12VDC model, except 24VDC power input replaces 12VDC. CS14HR-ff-24VDC = Same as CS14H-24VDC model, but includes DIN-RAIL-MC2 mounting option.
CS14, CSN14 Series Converter Switches Installation and User Guide (02/06)
“SC” = 100Base-FX-SC: multi-mode fiber optic with SC type connector, 2km. “SSC”= 100Base-FX-SSC: single-mode fiber optic with SC type connector, 20km. “SSCL”= 100Base-FX-SSCL: single-mode fiber optic with SC type connector, 40km. “ST” = 100Base-FX-ST: multi-mode fiber optic with ST type connector, 2km. “SST” = 100Base-FX-ST: single-mode fiber optic with ST type connector, 2km. “SLC”= 100Base-FX-SLC: single-mode fiber optic with LC type connector , 15km. “MTRJ”= 100Base-FX-MTRJ: multi-mode fiber optic with MTRJ type connector, 2km.
Accessories
CS14, CSN14 Series Converter Switches Installation and User Guide (02/06)
2.0 INTRODUCTION
This section describes CS14- and CSN14-Series models, including appearance,
features and typical applications.
2.1 Inspecting the Package and the Product
Examine the shipping container for obvious damage prior to installing this product; notify the carrier immediately of any damage which you believe occurred during shipment or delivery. Inspect the contents of this package for any signs of damage and ensure that the items listed below are included.
CS14, CSN14 Series Converter Switches Installation and User Guide (02/06)
Remove the Magnum CS14 or CSN14 Series Converter Switch from the shipping container. Be sure to keep the shipping container should you need to ship the unit at a later date. In the event there are items missing or damaged contact your supplier. If you need to return the unit, use the original shipping container. Refer to Section 5 Troubleshooting, for specific return procedures.
2.2 Pr oduc t Description
Combine a 10 or 100 Mb Fiber Media Converter and a two-port 10/100 copper Switch, and you have the Converter Switch, a flexible edge-of-the-network Ethernet
CS14, CSN14 Series Converter Switches Installation and User Guide (02/06)
heavy-duty and extended temperature operation ranges are included selectively in the Hardened factory-floor and Premium-rated outdoor models. This selection of models and fiber port types offers the best price-to-value ratio for each user and installation. Where a Media Converter might have been used, a Converter Switch offers a better value. The compact package is ideal for network edge installations, and is able to be conveniently mounted to suit any application.