GarrettCom Magnum 6K8-Series, Magnum 6K8, Magnum 6K8-24VDC, Magnum 6K8-5VDC, Magnum 6K8-48VDC Hardware Installation And User's Manual

...
www GarrettCom com
..
Magnum 6K8-Series
Industrial Field Switch
Hardware Installation
and
User Guide
Magnum 6K8-Series Industrial Field Switch Installation & User Guide (03/06)
www GarrettCom com
..
Magnum
6K8-Series
Industrial Field Switch
Hardware
Installation and User Guide
Part #: 84-00160 (Rev. A)
Trademarks
Ethernet is a trademark of Xerox Corporation
NEBS is a trademark of Telcordia Technologies
UL is a registered trademark of Underwriters Laboratories
GarrettCom, Magnum and Personal Switch are trademarks and Personal Hub is a
registered trademark of GarrettCom, Inc.
Important: The Magnum 6K8-Series Industrial Field Switch contains no user
serviceable parts. Attempted service by unauthorized personnel shall render all
warranties null and void. If problems are experienced with Magnum 6K8-
Series Switch products, consult Section 6, Troubleshootings, of this User
Guide.
Copyright 2006 GarrettCom, Inc. All rights reserved. No part of this publication may
be reproduced without prior written permission from GarrettCom, Inc.
Printed in the United States of America.
Magnum 6K8-Series Industrial Field Switch Installation & User Guide (03/06)
www GarrettCom com
..
Contacting GarrettCom, Inc
Please use the mailing address, phone and fax numbers and email address listed below:
GarrettCom, Inc.
47823 Westinghouse Dr.
Fremont, CA 94539-7437
Phone (510) 438-9071
Fax (510) 438-9072
Website: http://www.GarrettCom.com
email support@garrettcom.com
Federal Communications Commission
Radio Frequency Interference Statement
Radio Frequency Interference Statement
This equipment generates, uses and can radiate frequency energy and if not installed and used properly, that is in strict accordance with the manufacturer's instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user, at his own expense, will be required to take whatever measures may be required to correct the interference.
Canadian Emission This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil respecte toutes les exigences du Réglement sur le matériel du Canada. Cet appareil est Classe A..
Magnum 6K8-Series Industrial Field Switch Installation & User Guide (03/06)
www GarrettCom com
..
Table of Contents........................................................................... Page
1.0
SPECIFICATIONS ............................................................................... 2
1.1
Technical Specifications ...................................................................... 2
1.2
Ordering Information........................................................................... 5
2.0
Introduction............................................................................................ 7
2.1
Inspecting the Package and Product .................................................... 7
2.2 Product Description - Magnum 6K8-Series (6K8) .............................. 8
2.2.1a Magnum 6K8-Series, Industrial Field Switch.............................. 9
2.2.2
Eight-port SFF fiber modules 100Mb fiber ............................... 11
2.2.3
Eight-Port Copper Module, 6K8-RJ45 ...................................... 12
2.2.4
Six-Port “4 + 2”Combo Modules, fiber
100Mb ST or SC
............ 12
2.2.5
Four-Port 10 Mb and 100Mb mm Fiber ST Modules.............. 13
2.2.6
Gigabit (1000Mbps) port modules............................................. 14
2.2.7
Packet Prioritization, 802.1p QOS............................................. 14
2.2.8
Frame Buffering and Flow Control............................................ 15
2.2.9
Managed Network Software for Magnum 6K8-Series .............. 16
2.3
Features and Benefits......................................................................... 17
2.3
Features and Benefits......................................................................... 17
2.4
Applications ....................................................................................... 18
3.0
Installation............................................................................................ 22
3.1
Locating Magnum 6K8-Series Switches............................................ 22
3.2
Connecting Ethernet Media ............................................................... 23
3.2.1
Connecting Fiber Optic ST-type, “twist-lock”........................... 23
3.2.2
Connecting Fiber Optic SC-type, "Snap-In".............................. 24
3.2.3
Connecting Single-Mode Fiber Optic ........................................ 24
3.2.4
Connecting Twisted Pair Unshielded or Shielded .................... 24
3.2.5
Connecting Twisted Pair Unshielded or Shielded ..................... 25
3.2.6
Connecting Gigabit Media Using GBICs .................................. 25
3.3
DIN-Rail Mounting............................................................................ 25
3.3.1
Installing DIN-RAIL variable brackets on Magnum 6K8 ......... 27
3.3.2
Mounting Dimensions for 6K8 with metal brackets.................. 29
3.4
Powering the Magnum 6K8-Series Industrial Field Switch .............. 30
3.5 Alarm Contacts for monitoring internal power, and Software Traps.... 31
3.6 6K8-Series Port Module (6KPMV) Installation ................................ 31
3.6.1 Preparation for Installing and Removing 6KPMVs from 6K8’s ...... 32
3.6.2
Installing 6KPM Cards in the Magnum 6K8-Series .................. 34
3.6.3
Removing 6KPM Cards............................................................. 37
3.7
Connecting a Management Console Terminal to Magnum 6K8........ 38
3.7.1
RS-232 (DB-9) Console Com port (Serial port) pin assignments.39
4.0
OPERATION....................................................................................... 40
4.1
Switching Functionality ..................................................................... 40
4.2
Dual LEDs
Status
on TOP and Front of the 6K8-Series unit ............. 41
4.3
Auto-Cross(MDIX) and Auto-negotiation, for RJ-45 ports............... 41
Magnum 6K8-Series Industrial Field Switch Installation & User Guide (03/06)
www GarrettCom com
..
4.4
Flow-control, IEEE 802.3x Standard................................................. 43
4.5
Power Budget Calculations for Magnum 6K8-with Fiber Media...... 43
5.0
Introduction - Magnum 6K8 Industrial Field Switch Port Modules45
5.1
Inspecting the Package and Product .................................................. 45
5.2
6KPMV Module Description............................................................. 45
5.2.1
6KP6-RJMST, FX-ST “twist lock” Combo Module ................. 46
5.2.1a 6KP6-RJ10ST, mm FX-ST “twist lock” Combo Module.......... 46
5.2.1b 6KP4-F10ST, multi-mode FX-ST “twist lock” Module ........... 47
5.2.1c 6KP4-FLSTFX,multi-mode FX-ST “twist lock” Module.......... 47
5.2.2. 6KP6-RJMSC multi-mode FX-SC “snap-in” Fiber connector ........ 48
5.2.3
6KP6-RJSSC single-mode FX-SC-type, “snap-in” connector... 48
5.2.4
6KP6-RJSSCL single-mode FX-SC-type, “snap-in” connector 49
5.2.4a 6KP6-RJ10ST multi-mode FL-ST-type, “twist-lock” connector49
5.2.5 6KP8-MTRJ, small-Form-factor..................................................... 50
5.2.5a 6KP6-MT10ST, MTRJ Small-Form-Factor ST-Fiber port.......... 50
5.2.6
6KP8-45MT, MTRJ Small-Form-Factor ................................... 51
5.2.7
6KP8-MLC, Small-Form Factor............................................... 51
5.2.8
6KP8-45LC, LC small-form factor............................................ 52
5.2.9
6KP8-RJ45 (Twisted Pair), 10/100Mb 8-Port .......................... 52
5.2.10 6KP8-45-2MT, multi-mode FX , MTRJ Small-Form-Factor .... 53
5.2.10a
6KP8-45-2LC, single-mode FX , LC Small-Form-Factor ..... 53
5.2.11 GBIC-SXSC Gigabit fiber(1000Mb)multi-mode SC Connector54
5.2.11a
GBIC-LXSC Gigabit fiber multi-mode SC Connector .......... 55
6.0
TROUBLESHOOTING...................................................................... 56
6.1
Before Calling for Assistance ............................................................ 56
6.2
When Calling for Assistance ............................................................. 57
6.3
Return Material Authorization (RMA) Procedure ............................. 57
6.4
Shipping and Packaging Information................................................. 58
APPENDIX A: WARRANTY INFORMATION......................................... 58
APPENDIX B : Internal DC Power Supply Options.................................... 58
APPENDIX C: Internal DC Dual-Source Power Option............................. 61
Revisions 03/06: Minor update on 10/05 : Initial Release, Rev A
09/05 : Draft of Initial Release, Rev A
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
1
www GarrettCom com
..
THE MAGNUM LINE
Ethernet connectivity products
"Designed and Manufactured in the USA"
Overview
GarrettCom, Inc. offers the premium-quality Magnum line of Ethernet LAN connectivity products with industry-standard functionality and built-in fiber configurability. Magnum products are designed for use in demanding Carrier Class, Industrial Grade and OEM applications where reliability is a primary consideration.
6K-Series Managed Fiber Switches, MODULAR- Gigabit, 100 and 10 Mbps, fiber and
copper ports, mix-and match. Features SFF fiber and DC power in 1U units.
Edge SwitcHEs, Economical 6 port 10/100 and a combo of fiber+copper, provide an
effective solution for Industrial and outdoor environment.
POE POWER SOURCE SWITCH, 4 10/100 Power source switch to provide power,
data, and voice through RJ-45 ports.
Converter and convenient switches, 4 port 10/100 compact & economical switcehs and 3-port (2 10/100 and one fiber 10 or 100Mbps) converter switches for temperature
un
controlled locations.
4K-Series Switches, 100 and 10 Mbps, copper ports with optional fiber port, with auto-
negotiating full switching performance.
Quad-Series Fiber Switches, MODULAR- 100 & 10Mbps, fiber and copper ports,
mixed-speed and mixed-media types, full switching performance.
“Outdoor” Ethernet Switch, for temperature un
controlled locations
6 10/100 and 2 100Mb fiber ports, can be connected in strings
Mixed-Media Fiber Hub, 16-port Stackable,10/100 auto-sensing Dual Speed 8-port and 16-port Stackables, 10/100 auto-sensing Stackable Hubs, SNMP Optional
10Mb series(12/24 ports RJ-45), w/ optional port modules
Personal Switches, 10/100Mb
8 port dual speed, Auto-negotiable with fiber option
Personal Hubs, 100Mb or 10/100Mb 8-port, with two switched ports (1 fiber built in) Personal Hubs, 10Mb series
8-port + AUI, stackable to 5 high, + optional BNC of fiber port
8 or 9-port and 4 or 5-Port Personal Hubs, w/ man. up-link sw. Media Converters, 10Mb and 100Mb series
All media combinations, incl. fiber ST, SC, mm., single mode
The “X-line” of configurable MiX
ed Media products: Stackable Concentrators, SNMP optional, 13-Ports Mini-Concentrators, 7 Ports, Repeaters, 2-Ports
Repeater Port Modules (RPMs), 6 types for Ethernet media Bridge Port Modules (BPMs), 4 types, for segment isolation Transceivers, 10Mb series Mini-Transceivers and Coax Models
Mar., 06
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
2
www GarrettCom com
..
1.0 SPECIFICATIONS
1.1 Technical Specifications
Performance
Filtering / Forwarding Rate: Ethernet(10Mb):14,880 pps Fast Ethernet(100Mb): 148,800 pps Gigabit Ethernet(1000Mb): 1, 488,000 pps
Switching Processing Type: Store and Forward with IEEE 802.3x full-
duplex flow -control, non-blocking
Data Rate: 10Mbps,100Mbps and 1000Mbps
Address Table Capacity: 4K node, self-learning with address aging Packet buffer size : 240KB for 10/100 and 120KB for 1000Mb Latency: 5 s + packet time (100 to 100Mbps) 15 s + packet time (10 to 10 Mbps, and 10 to 100Mbps)
Network Standards and Compliance, hardware
Ethernet V1.0/V2.0 IEEE 802.3: 10BASE-T, IEEE 802.3u: 100Base-TX, 100BASE-FX IEEE 802.3z: 1000BASE-TX Ethernet (Auto-Negotiation) IEEE 802.3ab: 1000BASE-TX Ethernet IEEE 802.1p: Priority protocol IEEE 802.1d: Spanning tree protocol IEEE 802.1q: VLAN Tagging IEEE 802.3x: Flow Control
Maximum 10 Mbps Ethernet Segment Lengths
Unshielded twisted pair - 100 m (328 ft) Shielded twisted pair - 150 m (492 ft) 10BASE-FL multi-mode fiber optic - 2 km (6,562 ft) 10BASE-FL single-mode fiber optic - 10 km (32,810 ft)
Maximum Standard Fast Ethernet Segment Lengths: 10BASE-T (CAT 3, 4, 5 UTP) - 100 m (328 ft)
100BASE-TX (CAT 5 UTP) - 100 m (328 ft)
Shielded twisted pair - 150 m (492 ft) 100BASE-FX, half-duplex, multi-mode - 412 m (1350 ft) 100BASE-FX, full-duplex, multi-mode - 2.0 km (6,562 ft) 100BASE-FX, half-duplex, single-mode - 412 m (1350 ft)
100BASE-FX, full-duplex, single-mode - 20.0 km (66K8-Series ft) 100BASE-FX, full-duplex, Long Reach - 40.0 km (122K ft)
Maximum Standard Gigabit Ethernet Segment Lengths:
1000BASE-T (CAT5e or higher is recommended) - 100 m (328 ft) 1000BASE-SX, full-duplex, multi-mode(62.5m cable) - 220m 1000BASE-SX, full-duplex, multi-mode(50m cable) - 550m
1000BASE-LX, full-duplex, single-mode(62.5m cable) -5Km
Fiber Multi-mode connector types supported:
Fiber Port, ST-type (twist-lock):Fiber multi-mode, 10Mb 10BASE-FL Fiber Port, MTRJ-type (plug-in):SFF Fiber multi-mode100BASE-FX Fiber Port, SC-type (snap-in):Fiber optic multi-mode, 100BASE-FX Fiber Port, ST-type (twist-lock): Fiber optic m.-mode, 100BASE-FX
Fiber Port, 1000BASE-FX, GBIC modules
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
3
www GarrettCom com
..
Fiber Single-mode connector types:
Fiber Port, SC-type: Fiber optic single-mode, 100BASE-FX Fiber Port, LC-type Fiber optic SFF single-mode, 100BASE-FX Fiber Port, 1000BASE-FX, GBIC modules
LEDs: Per Port (one set at the port, one set on rear top) LK: Steady ON when media link is operational
ACT: ON with receiver port activity FDX/HDX: ON = Full-Duplex Mode OFF = Half-Duplex Mode 100/10: ON = 100Mbps speed OFF = 10 Mbps
Operating Environment
Ambient Temperature:
-40 to 140 F (-40 to 60C) for UL60950 and Component Parts rating
-60 to 205 F (-50 to 95C) for IEC 60068 Type Test short term rating Storage Temperature: -60to 210F (-50to 100C) Ambient Relative Humidity: 5% to 95% (non-condensing) Altitude: -200 to 13,000 ft. (-60 to 4000m) Conformal Coating (humidity protection) option: Request quote
Alarm Relay Contacts
One NC indicating internal power, one NC software controllable
Packaging
Enclosure: Rugged High strength sheet metal. Dimensions: 9.8 in. H x 5.90 in. W x 3.70 in. D
24.9 cm H x 15.0 cm W x 9.4 cm D
Cooling method: Convection, fully –enclosed elongated dual-cavity case
used as heat-sink. designed for vertical mounting, no fans
Weight: 2.1 lbs. (0.95 kg)
Management Console connector
DB-9 for RS-232 “null-modem” cable (sometimes called an X-modem cable)
Power Supply (Internal)
AC Power Connector: IEC-type, male recessed at rear of chassis, Input Voltage: 100 to 240 VAC (auto-ranging) Input Frequency: 47 to 63 Hz (auto-ranging) Power Consumption: 25 watts typical (for a fully loaded fiber model) 15 watts typical (for a 8-port copper only model)
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
4
www GarrettCom com
..
DC Power Supply (Options)
-48VDC Power Input Voltage : -36 to -70 VDC 24VDC Power Input Voltage : 18 to 36VDC 125VDC Power Input Voltage : 88 to 300VDC 5VDC Power Input Voltage : (+) or (-) 5%
Std. Terminal Block : “ -, GND, + ” Power Consumption: same as for AC models, see above
For DC internal power supplies at –48VDC, 24VDC and 125VDC,
including Dual Source options (
for continuity of operation when either of the
DC input sources are interrupted)
, see Appendices B and C.
Per-port MDI or MDIX on RJ-45
The copper daughter board has MDI-MDIX Auto-crossover on all the RJ-45
ports., and eliminate the use of cross-over cable between the devices. Also port-specific user settings (such as FDX or HDX, copper 10/100 speed) can be fixed using software commands.
Mountings:
Vertical mounting only Suitable for wall or DIN-Rail mounting
Agency Approvals Magnum 6K8 UL listed (UL60950), cU, CE
Emissions meet FCC Part 15 Class A IEEE P1613 Environmental Standard for Electric Power Substations
IEEE 61850 EMC and Operating Conditions, class C for Electric Power
Substations
NEMA TS-2 and TEES for traffic control equipment
Note: These products are tested and approved under IEC61850 for use in Class C sheltered locations where neither temperature nor humidity are controlled. The equipment needs to be protected against solar radiation, rainfall, other precipitations and wind. UL has not approved these products for Annex-T outdoor use.
Warranty: Three years, per UL 60950 temperature rating Made in USA
Email
sales@GarrettCom.com
for details.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
5
www GarrettCom com
..
1.2 Ordering Information
Magnum Industrial Field Switch (8 ports max)
MODEL DESCRIPTION
Magnum 6K8 -Managed Industrial Field Switch, base unit for vertical mounting.
Worldwide AC power. May be configured with a selection of 10/100/1000 fiber and copper port connector types, 8 total ports max. for 10/100Mbps or 2 ports maxm for Gigabit ports. Two metal brackets for vertical wall or panel mounting. Wire speed filtering and forwarding across all ports, 802.3x flow control, 802.1p priority packet processing, self-learning 4K-node address table, large 240KB packet buffers for 10/100 and 120KB for 1000Mb. For licensed managed networks software (MNS-6K and S-ring), See separate data sheets.
Magnum 6K8 -24VDC: Same as 6K8 except the power input is 24VDC Magnum 6K8 -5VDC: Same as 6K8 except the power input is regulated 5VDC & fused Magnum 6K8-48VDC: Same as 6K8 except the power input is –48VDC Magnum 6K8-125VDC: Same as 6K8 except the power input is 125VDC Configuration Options: Each Magnum 6K8 base unit has one port module slot which can be equipped with
one of the following single or multi-mode fiber, copper, 1000, 100 or 10Mbps modules.
Magnum 6K8 Port Modules 6KP8V-RJ45 TP Module, with 8x10/100Mbps auto-negotiating RJ-45 ports 6KP8V-MTRJ SFF Fiber module, with 8x100Mb mm FX MT-RJ connectors 6KP8V-MLC SFF Fiber module, with 8x100Mbps mm FX LC connectors 6KP8V-SLC SFF Fiber module, with 8x100Mbps single-mode FX LC connectors 6KP4V-FXSC “2+2” 100Mb Fiber module, with 4x100Mb 2km FX SC connectors 6KP4V-FXST “2+2” 100Mb Fiber module, with 4x100Mb 2km FX ST connectors 6KP4V-F10ST “2+2” 10Mb Fiber module, with 4x10Mb 2km FL ST connectors 6KP4V-FLSTFX “2+2” ST Fiber module, with 2x100Mb & 2x10Mb ports, 2km 6KP8V-45-2MT “6+2” module, with 6xRJ-45 ports and 2x100Mb 2km FX MTRJ 6KP8V-45-2SLC “6+2” module, with 6xRJ-45 ports and 2x100Mb s.m 15km FX LC 6KP8V-45MT “4+4” module, with 4xRJ-45 ports and 4x2km mm FX MTRJ 6KP8V-45MLC “4+4” module, with 4xRJ-45 ports and 4x2km mm LC connectors 6KP8V-45SLC “4+4” module, with 4xRJ-45 ports and 4x2km single mode LC 6KP6V-RJMST “4+2” module, with 4xRJ-45 ports and 2x2km mm FX SC 6KP6V-RJMSC “4+2” module, with 4xRJ-45 ports and 2x2km mm FX ST 6KP6V-RJSSC “4+2” module, with 4xRJ-45 ports and 2x20km single.mode FX SC 6KP6V-RJSSCL “4+2” module, with 4xRJ-45 ports and 2x40km single mode FX SC 6KP6V-MT10ST “4+2” module, with 4xMTRJports and 2x10Mb 2km FL ST 6KP6V-RJ10ST “4+2” module, with 4xRJ-45 ports and 2x10Mb 2km FL ST
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
6
www GarrettCom com
..
6KP5V-G4RJ “G+4” module, with one GBIC receptacle for one user selectable GBIC
transceiver (see below) with 4 fixed 10/100 RJ-45 ports.
6KP3V-G2SC “G+2” module, with one GBIC receptacle for one user selectable GBIC
transceiver (see below) and 2 100Mb 2km FX SC fiber ports.
GBPMV-2OTX Two-port Gigabit module for 6K8-Series Switches, with two GBIC
receptacles for user selectable GBIC transceivers (see below).
GBPMV-COTX One slot Gigabit module for 6K8-Series Switches, with one GBIC
receptacle for a user selectable GBIC transceiver module (see below).
GBIC(1000Mb) Transceiver options for Mangum 6K8-Series GBIC-SXSC One 1000BASE-SX port with 850nm multi mode SC fiber connector GBIC-LXSC10 One 1000BASE- LX/LH port with 1310nm single mode SC(10km)
fiber connector
GBIC-LXSC25 One 1000BASE- LX/LH port with 1310nm single mode SC(25km)
fiber connector
GBIC-ZXSC40 One 1000BASE-ZX port with 1550nm, single mode SC(40km) fiber
connector
GBIC-ZXSC70 One 1000BASE-ZX port with 1550nm, single mode SC(70km) fiber
connector
GBIC-TP One 802.3ab 1000BASE-T port, RJ-45 connector
CONSOLE CBL Industry standard serial cable, DB-9 connectors for RS-232 “ null-
modem “ connection (sometimes called an X-modem cable), used to connect a PC or a character terminal to the Management port.
CONSOLE USB Industry standard serial cable, DB-9 connectors for RS-232 “ null-
modem “ connection (sometimes called an X-modem cable) to connect to a managed switch, and a USB port to connect to a PC
DIN-RAIL-VRM DIN-Rail holder for a secure vertical mount of a 6K8-Series unit,
with screws to attach to metal mounting brackets of the 6K8 case.
GarrettCom, Inc. reserves the right to change specifications, performance
characteristics and/or model offerings without notice.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
7
www GarrettCom com
..
2.0 Introduction
2.1 Inspecting the Package and Product
Examine the shipping container for obvious damage prior to installing this
product; notify the carrier of any damage that you believe occurred during shipment or
delivery. Inspect the contents of this package for any signs of damage and ensure that
the items listed below are included.
This package should contain:
1 Magnum 6K8-Series Industrial Field Switch, base unit (configured with user-selected port module options installed)
1 AC Power Cord (U.S. and other 115 VAC only) if AC version
1 Set of two metal vertical mounting brackets, with screws to the case
1 Installation and User Guide (this manual)
1 Product Registration Card
Remove the items from the shipping container. Be sure to keep the shipping
container should you need to re-ship the unit at a later date. To validate the product
warranty, please complete and return the enclosed Product Registration Card to
GarrettCom, Inc. as soon as possible.
In the event there are items missing or damaged, contact the party from whom
you purchased the product. If the unit needs to be returned, please use the original
shipping container if possible. Refer to Section 6, Troubleshooting, for specific return
procedures.
NOTE: This Hardware user- manual only contains the hardware related information about the Magnum 6K8 and provides help for Network installation, wiring, and other hardware features. Refer to our
Software user Manual
for
management software features and configurations (e .g. VLANS, RSTP, SNMP, RADIUS, TACACS etc.) using this URL-
www.garrettcom.com/techsupport/software/userguides/6kseries_softugrel3.pdf
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
8
www GarrettCom com
..
2.2 Product Description - Magnum 6K8-Series (6K8)
The M
agnum 6K8-Series, Industrial Field Switch is the smallest member of
the Managed 6K-Switch family. It is equipped with one module slot configurable to 8-
ports. It is specially designed to meet industrial, power substation, and outdoor Ethernet
specifications while fulfilling the needs of hardened applications. 6K8-Series managed
field switches provide modularity of fiber and copper ports. They come with a
combination of 10Mb, 100Mb and 1000Mb speed ports with comprehensive management
software in a compact industrial-grade package. The combination of multiple possible
configurations, multiple power
options, a hardened enclosure, and
MNS-6K management software
makes the Magnum 6K8 a very
powerful, effective and reliable
managed Field Switch providing a
secure solution for many needs.
Setting a new standard for Industrial and Carrier Class applications, heavy duty Ethernet Switch requirements are readily accommodated with an extended temperature rating of -40˚C to 60˚C calculated by the UL Component Parts method, or ­50˚C to 95˚C by the IEC 60068 calculated by the Type Test method. With various Power Supply options, such as all popular DC power input types, worldwide AC power and DIN-Rail mounting, the hardened Magnum 6K8-Series is a “multi-purpose” Industrial Ethernet Switch.
The extremely versatile options of various port modules offer all fiber media
possibilities including small form factor (all connector types, multi- and single-mode)
and 10/100 Mb auto-negotiating RJ-45 ports. Standard GBIC ports can be configured for
a variety of Gigabit cabling types and distances. For details about module configurations
please go to http://www.garrettcom.com/techsupport/insertion_guides/6k8cg.pdf
Advanced thermal design techniques (patent pending) transform the tough metal case into a heat sink as well as a shield for reducing electrical noise and providing physical protection. The unique design features an elongated dual-cavity shape for
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
9
www GarrettCom com
..
optimal cooling of internal components without any ventilation openings. This sealed­case design enables the unit to operate in temperature un-controlled environments, achieve high EMI noise immunity and provide an un-matched IP53 physical protection rating against dust, dirt, insects, and liquid spills.
http://www.garrettcom.com/Pictorial/6k8_pictorial.pdf
High performance features include non-blocking speed on all ports and 802.1p
QoS Traffic Prioritization. Magnum 6K8-Series switches are “plug-and-play” ready for
use as backbone switches where a mix of bursty data traffic and priority streaming traffic
for VoIP and audio/video “Triple Play” applications are present.
Magnum 6K8-Series Fiber Switches are provided with LAN management
software including SNMP, Tag and Port-based VLANs, IGMP Snooping and Port
Security with control via secure Web and command line interface (CLI). Loaded with
secure features like- Radius server (802.1x), TACACS+, SNMPV3 and Port Security
allow this Industrial Field Switch to qualify for a sub-standard managed switch to meet
the Industrial expectation. For high availability, Redundant LANs using ring/mesh
topologies, Spanning Tree Protocol, Rapid Spanning Tree Protocol, Link-Loss-Learn and
S-Ring (ring only) are available. See the Managed Networks Software (MNS-6K) and S-
Ring datasheets for additional details on the comprehensive set of software programs and
options.
Magnum 6K8-Series, Industrial Field Switches have heavy duty
metal cases and auto-ranging power supplies for operation with standard AC power
worldwide. Internal DC power supplies are optional. All DC power input types (24V,
48V, 125V) are supported, and dual source input is optional.
Alarm Relay contacts provided on each Magnum 6K8-Series Switch are
monitored via the hardware and software providing a loss of power signal and user-
defined software events through traps. See Section 3.5 for details.
The wide selections of port modules are key to the flexibility and adaptability.
2.2.1a Magnum 6K8-Series, Industrial Field Switch
The Magnum 6K8-Series is primarily designed for use in vertical mount applications.
Equipped with multi-media fiber/copper solutions, multiple speed 10/100/1000Mb
support, rich MNS-6K management features, hardware and software alarms and
convection cooling (no fans), the Magnum 6K8 easily qualifies for use in transportation
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
10
www GarrettCom com
..
and traffic control systems, power utilities and industrial factory-floors. For the fast
growing demands of video surveillance systems with segments requiring Gigabit
backbone interconnections, the Magnum 6K8 managed switches are easy to install and
operate with Magnum 6K management firmware.
The advanced generation of industrial applications requires advanced managed network
software, operation at extended
temperatures, fiber ports modularity,
support for self-healing ring structures,
redundancy, security and gigabit backbone
configurability. The Magnum 6K8 has all
of these, in a very tough and robust metal
case with a wide choice of popular DC
options or industry standard AC internal
input.
The plug-n-play Magnum 6K8 Industrial
Field switches, should be mounted vertically using
the vertical mounting brackets which come along
with the unit or by using the DIN-RAIL-KIT
(optional) for Din rail mounting.
Loaded with versatile and secured management
software (MNS-6K), the 6K8 switch can be easily
managed and monitored via SNMP or secured Web.
Supporting dual Gigabit ports (copper or fiber) in
one slot defines the Magnum 6K8 Field switches role as an effective Managed Gigabit media converter Switch that meets any secured Gigabit media requirements.
Dual LEDs on the front and Top side help the vertically mounted 6K8 to be monitored
easily. The modular designed Magnum 6K8 Industrial Field switch can support a
maximum of two Gigabit modules (fiber or copper) to meet any demand of bandwidth
required applications. In an on-going demand of diversified designed Ethernet
applications, the Magnum 6K8 is a fine solution to meet and satisfy any requirements
through its rich modular structure. The Relay contact for external “ALARM” is another
additional feature which allows the Magnum 6K8 to monitor the internal power failure
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
11
www GarrettCom com
..
and controlled via hardware or software trap controls. The options for universal AC and
24V/-48V/125VDC power options offer a widely accepted managed switch with high
reliability.
2.2.2 Eight-port SFF fiber modules (6K8-MTRJ, 6K8-MLC), 100Mb fiber
Fig.2.2.2 : SFF Fiber Port
Modules, 6K8-MTRJ (to the left)
and 6K8-MLC or -SLC
(below)
In an eight-port SFF fiber port module, all of the fiber ports are of the same
speed (100Mb), mode, and connector type. Models available with Small Form Factor
(SFF) are multi-mode MT-RJ or LC-type connectors, and single-mode LC-type
connectors.
The 100Mb fiber eight-port
modules for the Magnum 6K8-Series
normally are set (factory default) to
operate in full-duplex mode for best
fiber distance and performance. Using
the 6K-MNS software, the user may
select full- or half-duplex mode per-port through set-up of the software (See Magnum
6K-MNS Software Manual) for the flexibility to adapt to any FDX or HDX type of Fast
Ethernet devices).
There are three LED’s per fiber port. The Link (LK) LED indicates “ready for operation” on that port when lit, the F/H LED indicates operation in full-duplex mode when ON (half-duplex when OFF), and the blinking ACT LED indicates receiving Activity on the port. A fiber cable must be connected into a SFF port and the Link (LK) indicator for that port must be ON (indicating there is a powered-up device at the other end of the cable) in order for a LK LED to provide valid indications of operating conditions on that port.
1 3 5 7
2 4 6 8
LK LK LK LK
ACT F/H
ACT F/H
ACT F/H
ACT
F/H
LK LK LK LK
ACT
F/H ACT
F/H
ACT
F/H
ACT
F/H
2 4 6 8
LK LK LK L
AC F/H
AC F/H
ACT
F/H
ACT
F/H
2 4 6 8
LK LK LK L
AC F/H
AC F/H
ACT
F/H
ACT
F/H
1 3 5 7
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
12
www GarrettCom com
..
2.2.3 Eight-Port Copper Module, 6K8-RJ45
The 6K8-Series’s 8-port Copper port module, model 6K8-RJ45, provides eight 10/100Mb switched RJ-45 ports. The 10/100Mb switched ports normally (as a default setting) are independently N-way auto-negotiating, and auto-crossover(MDIX) for operation at 10 or 100Mb speed in full- or half-duplex mode, i.e., each independently selects a mode and speed to match the device at the other end of the twisted pair cable.
(See Section 4.3 for auto-negotiation and MDIX details). The auto-crossover feature will automatically determine the other side of connection to make the connection, and eliminate the need of cross-over cable.
On the model 6K8-RJ45 module, there are four LEDs for each port, two in the connector and two separate. The LK (Link) LED indicates “ready for operation” on that port when lit. The blinking ACT (Activity) LED indicates receiving Activity on that port when lit. The 10/100 LED indicates operation at 100Mb speed when ON and at 10 Mb speed when OFF (when auto-negotiation is not disabled). The FDX/HDX LED is ON to indicate full-duplex operation and OFF to indicate half­duplex mode. A twisted pair cable must be connected into an RJ-45 port and the Link (LK) indicator for that port must be ON (indicating there is a powered-up device at the other end of the cable) in order for a LK LED to provide valid indications of operating conditions on that port.
Using the 6K8-Series (MNS-6K) management software, the user may disable auto-negotiation and fix the desired operation of each RJ-45 port. User may select 10Mb or 100Mb speed and full- or half-duplex mode per-port as per user requirement. (See Magnum MNS-6K Software Manual for details info.).
2.2.4 Six-Port “4 + 2”Combo Modules, 4@ 10/100 RJ-45 and 2@100Mb fiber
4@RJ-45 + 2@ 100Mb
ST or SC
The combo six-port modules are combinations of copper and fiber media, available as
four 10/100 switched RJ-45 copper ports and two 100Mb switched multi-mode fiber in
either ST, SC, single mode SC or Long Reach SC ports. For port numbering, ports
1,3,5,7 are copper, ports 2 and 6 are fiber, and ports 4 and 8 are not present.
The four RJ-45 ports operate just like the 8-port copper module with auto-cross
1 3 5 7
10/100
LK
F/H
ACT
10/100
LK
2 4 6 8
F/ H
ACT
1 3 5 7
2 6TX RX
TX LK RX
LK
ACT F/H
ACT F/H
10/100
LK
F/H
ACT
1 3 5 7
2 6TX RX
TX LK RX
LK
ACT F/H
ACT F/H
10/100
LK
F/H
ACT
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
13
www GarrettCom com
..
(MDIX) features to eliminate the use of cross-over cables. The two fiber ports operate at
100Mbps full-duplex (default). User mode control per port through the MNS software is
also the same.
On Magnum “4+2” Combo modules, there are four LED’s for each RJ-45 port,
which indicate status as described for the 6K8-RJ45 in Section 2.2.3 above. The fiber
port LEDs indicate status the same way as described for the SFF fiber modules in Section
2.2.2 above. Color-coding on the panel of the module shows which LEDs belong to
which port.
The Magnum Combo six-
port modules are also available with
4@ MTRJ 100Mb mm SFF fiber and
2@10Mb fiber mm ST ports, or 4@
RJ45 10/100 copper and 2@10Mb
fiber mm ST ports. The
4@ RJ-45 + 2@ 10 Mb ST operation of the SFF fiber and the RJ-45 half of
the module is as described for those port types above. For detailed information about
10Mb mm ST fiber half of the module, see Section 2.2.5.
2.2.5 Four-Port 10 Mb and 100Mb mm Fiber ST Modules
The 4-port @10Mb ST fiber modules behave the same as the 4@100Mb ST
fiber modules except for the 10Mb speed. For port numbering, ports 1, 2, 5, 6 are present,
ports 3, 4. 7, 8 are not present. There is also a similar 100Mb fiber SC module.
The default setup on the 10Mb fiber module is half-duplex, which allows the
Magnum 6K8-Series Switch to connect to any 10Mb hub or media converter or almost
any other device with a 10Mb fiber Ethernet port. The default setting of the 100Mb fiber
module is full duplex. User mode-control per port through the MNS “port settings”
software is the same as the other 6K8-Series modules.
The fiber ports support fiber-cabling distances according to the 10BASE-FL
and 100BASE-FX standards, i.e., 2km distance for multi-mode fiber. (Single-mode for
up to greater distance may be available as a special order, request quote).
1 3 5 7
2 6TX RX
TX LK RX
LK
ACT F/H
ACT F/H
10/100
LK
F/H
ACT
2 6
T
LK R
ACT F/H
TX RX
LK
ACT F/H
TX RXLK
ACT F/H
TX RXLK
ACT F/H
1 5
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
14
www GarrettCom com
..
2.2.6 Gigabit (1000Mbps) port modules
The Magnum 6K8-Series offers a wide range of optional Gigabit modules and
one or two Gigabit ports can be configured in one modular slot. The Gigabit modules are
the two port GBPMV-2OTX , the 6KP5V-G4RJ (single Gigabit+4 10/100 RJ-45 ports)
or the 6KP3V-G2SC (single Gigabit+2 100Mb fiber ports) as shown below in the figure.
1@ 1000Mb Fiber SC + 2@ 100Mb SC 1@ 1000Mb Fiber SC + 4@10/ 100Mb
The 6K8-Series Modules provide a GBIC opening for insertion of industry-standard
GBICs to provide Gigabit media flexibility. GBIC models are available for both multi-
mode (550m) and single-mode (10, 25, 40, 70) km fiber options. Gigabit copper is also
available with new models appearing often.
The 1000Mb Gigabit fiber-port modules on the Magnum 6K8-Series are
normally set (factory default) to operate at AUTO mode for best fiber distance and
performance. The 1000Mbps SC fiber-optic module on the Gigabit -SX and Gigabit-LX
transceivers are compatible with the IEEE 802.3z Gigabit standards.
There are two LEDs mounted on each Gigabit port module. The Gigabit fiber
port is by default configured to AUTO mode, and can be fixed at 1000Mbps speed full-
duplex mode at any time. The Gigabit fiber port has LEDs that indicate LK (Link status)
and ACT (receiving activity) on that port when lit.
NOTE: For detail information about the various port module 6KPMV options being used for Magnum 6K8, please check section5.2, 6KPM Module Description.
2.2.7 Packet Prioritization, 802.1p QOS
Quality of Service means providing consistent predictable data delivery to
users from datagram paths that go all across a network. As a LAN device, the Magnum
6K8-Series can do its part to prevent any QOS degradation while it is handling Ethernet
traffic through its ports and buffers.
2 6
1 3 5 7
10/100
L
F/
ACT
TX RXLK
ACT F/
TX RXL
ACT F/
TX LK RX
ACT F/
TX RXL
K
ACT F/
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
15
www GarrettCom com
..
The Magnum 6K8-Series switching hardware supports the IEEE 802.1p
standard and fulfills its role in support of QOS, giving packet processing priority to
priority tagged packets according to the 802.1p standard. In addition to hardware support
for QOS, the MNS software (Rel3) supports two priority queues that can be shared across
the eight levels of defined packet priorities for application-specific priority control by the
user through software configuration settings.
2.2.8 Frame Buffering and Flow Control
Magnum 6K8-Series’s are store-and-forward switches. Each frame (or packet)
is loaded into the Switch’s memory and inspected before forwarding can occur. This
technique ensures that all forwarded frames are of a valid length and have the correct
CRC, i.e., are good packets. This eliminates the propagation of bad packets, enabling all
of the available bandwidth to be used for valid information.
While other switching technologies (such as "cut-through" or
"express") impose minimal frame latency, they will also permit bad frames to propagate
out to the Ethernet segments connected. The "cut-through" technique permits collision
fragment frames (which are a result of late collisions) to be forwarded which add to the
network traffic. Since there is no way to filter frames with a bad CRC (the entire frame
must be present in order for CRC to be calculated), the result of indiscriminate cut-
through forwarding is greater traffic congestion, especially at peak activity. Since
collisions and bad packets are more likely when traffic is heavy, the result of store-and-
forward operation is that more bandwidth is available for good packets when the traffic
load is greatest.
When the Magnum 6K8-Series Switch detects that its free buffer queue space
is low, the Switch sends industry standard (full-duplex only) PAUSE packets out to the
devices sending packets to cause “flow control”. This tells the sending devices to
temporarily stop sending traffic, which allows a traffic catch-up to occur without
dropping packets. Then, normal packet buffering and processing resumes. This flow-
control sequence occurs in a fraction of a second and is transparent to an observer.
Another feature implemented in Magnum 6K8-Series Switches is a collision-based flow-
control mechanism (when operating at half-duplex only). When the Switch detects that
its free buffer queue space is low, the Switch prevents more frames from entering by
forcing a collision signal on all receiving half-duplex ports in order to stop incoming
traffic. The flow control option is user configurable (enable/disable) through the setport
command of MSN-6K software as per the requirement of a network.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
16
www GarrettCom com
..
2.2.9 Managed Network Software ( MNS-6K ) for Magnum 6K8-Series
Magnum 6K8-Series comes with licensed MNS-6K Firmware (Rel 3.2), which
allows the configuration of the Magnum 6Ks as a Managed Switch and also allows other
Software enabled features. For additional information about MNS-6K, see the Magnum
6K8-Series MNS Software User guide in pdf format, a separate document normally
accessed via your web-browser, at
ftp://ftp.garrettcom.com/
or FTP client program at ftp.GarrettCom.com . Use the following to log in.
user : m6kuser
password : m6kuser
All MNS-6K software information, including new releases and upgrades related to MNS-
6K software can be accessed and download from GarrettCom’s FTP site.
Alternatively, for documentation and latest information, or needed
GarrettCom proprietary MIBs
for SNMP-
please go to
www.GarrettCom.com/techsupport/index.htm#software and look for Magnum
MNS-6K info.
Magnum MNS-6K Operator Training
This interactive training software
instructs on all the basic and advanced information about the Magnum MNS-6K
management software and is a useful tool for the first time user.
Finally, please email: support@GarrettCom.com
for further information.
For upgrading the Magnum 6K8 Switch to its latest Magnum 6K­Firmware, follow through the steps and instruction provided on -
http://www.garrettcom.com/techsupport/software/upgrade_mns6k.pdf
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
17
www GarrettCom com
..
2.3 Features and Benefits
Managed switching for high performance Ethernet LANs Magnum 6K8-Series Switches provide non-blocking (all ports can run at full speed at
once) performance with standard Managed Networks Software (MNS-6K) included.
They are typically used in LAN traffic centers with 16 100Mb or 8+2 Gigabit ports for
backbone connections, where managed network services are desired.
Switching services includes 802.1p QoS packet prioritization The Magnum 6K8-Series switching hardware supports QoS, giving packet processing
priority to priority tagged packets according to the IEEE 802.1p standard. For port-
and application-specific priorities of data, the QoS software may be configured.
Large selection of built-in fiber options at 10/100/1000Mb
Magnum 6K8-Series Industrial Field Switches are designed to naturally include fiber
ports, and support mixes of multi-mode and single-mode; 10 Mb, 100Mb and 1000Mb speed; full-and half-duplex; classic Small Form Factor (SFF) and GBIC fiber connectors. RJ-45 10/100 ports can also be configured in the mix of port types.
S-Ring and Link Loss Learn for reliable high availability using ring topology S-Ring and Link-Loss-Learn provide reliable fast recovery of a fault in ring topology. Relay Contacts for monitoring internal power and user-defined software events
Two Alarm Relay contacts monitor basic operations. One is for hardware, and will
signal loss of power internally. The other is software controllable and will signal user­defined software event traps such as a security violation or an S-Ring fault condition.
Vertical mounting for efficient convection cooling, no fans, extended temp. Vertical mounting brackets are included. DIN-Rail mounting hardware is optional.
Ethernet signal and power cables attach in the bottom. Two sets of status LEDs are on the switch, one set viewable at the port connector and one set viewable from the front.
Standard AC power input, -48VDC or 24VDC or 125VDC input is optional
Standard AC power input is IEC plug, auto-ranging for worldwide use. For special
applications, models with –48VDC or 24VDC or 125VDC are available. Dual Source DC input can also be selected and configured on the DC power input models.
Heavy-duty design, for Industrial Ethernet and un-controlled temp. ope ration Fiber ports take more power than copper ports, but the Magnum 6K8-Series design
provides for this with heavy-duty components. The ambient temperature dual-rating is 60`C per UL methods, and 95C per type test methods.
MNS-6K licensed Network Management Software included, S-Ring optional
Release 3.1.2 (fall ’05) includes SNMP Switch Management with secure access
control, RMON, CLI, Port Security; Port Mirroring; Port Settings Control; Telnet, TFTP, FTP support, Spanning Tree Protocol, Link-Loss-Learn, S-Ring (with license key) multi-level QoS, Port- and tag-based VLANs, GVRP, IGMP Snooping, SNMPc GUI support; Event Log; SNTP client for time-of-day; BootP and DHCP client for IP configuring, and password security. Secured Web Management, RADIUS X and TACACS+. MNS-6K software is factory installed, supported and updated via Internet and GCI FTP Server.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
18
www GarrettCom com
..
2.4 Applications
Magnum 6K8-Series Fiber Switches offer high performance, modularity and
higher availability to provide an effective solution for Industrial Ethernet needs. They
provide the flexibility of 100Mbps fiber and copper ports as well as single or dual
Gigabit(1000Mb) ports, with industry-standard MNS-6K software. Magnum 6K8-Series
Switches are easily used in a variety of applications including client/server computing,
secure VLAN- performance upgrades to departmental networks, and stream traffic for
VOIP and audio/video applications for a diversified combination of mixed media for
monitoring and signaling in Industrial floor applications. The performance characteristic
of the 6K8-Series Switches enable them to inter-connect a series of subnets (one subnet
per 6K8-Series Switch port) in a LAN traffic center. The subnet connections may be via
fiber or twisted pair cabling, 1000Mbps, 100Mbps or 10 Mbps speed, and full-or half-
duplex.
The mixed-media modular capability is ideal for Industrial applications where
existing Ethernet LAN network cabling must be accommodated. The fiber-built-in
media capability is ideal for integrating future-proof fiber cabling into the LAN structure.
Example 1 : Magnum 6K8-Series Switch for a Industrial appl i cation
Equipped with lots of useful features such as a hardened Industrial enclosure, a
wide spread of AC/DC power supply options, extended temperature rating and secured
management features qualifies the Magnum 6K8-Series Managed switch for any
Industrial factory-floors, traffic control, transportations systems, monitoring and
signaling and power utilities applications. The bundle of MNS-6K software operated
features diversifies this managed switch to operate and perform securely and reliably in
all critical applications. The addition of the S-Ring and Link-Loss-Learn software feature
allows this Managed switch to provide a very reliable highly available redundant
network capability in any ring topology network.
In an Industrial environment where the factory floors are networked with
Ethernet based mixed-media LANs and equipped with PLC computers to take readings
and data from M/C Client/ Server databases and transport this important data to the
central office data warehouses the Managed 6K8-Series shines. The Managed 6K8-
Series’s modularity along with MNS-6K management software features handle these
kinds of networks very securely and reliably through out the Factory-floors. The DIN-
Rail Mounting options on the Magnum 6K8-, allow the Industrial Factory floor user to
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
19
www GarrettCom com
..
Interne
Route
Magnum
Fi
r
GARRE
M
agnu
m
PW
Mn
SwitMagnu
m
1 3
2 TX
LK
L
F/
F
10/1
L
F
1
10/1L
F
10/1
L
2 4
F
1
2 TX
LK
L
ACFAC
F/
10/1
L
F
Magnum 6K25
PL
PLPLPL
PL
PL
PL
PL
mount the 6K8 securely anywhere on their Network setup.
The option for setting the ports at 10 or 100Mb on copper, and supporting the
10 or 100Mb fiber media, provide widespread options to the users to mix and match their
legacy and advance network needs. The modularity of the 6K8-Series Industrial Field
Switch makes it an attractive choice for use in applications with LAN connections to an
organization’s multiple site offices and factory- floors. The different locations can be
easily connected together with the Fiber ports supported by the Magnum 6K8-Series
Switch. A main NT-server in a secure area protected from earthquake or fire hazards can
be connected to the full duplex Gigabit Fiber port.
Extended temp.ratings, 24V/125VDC power supply options, and IP53
approval qualifies this managed 6K8-Series switch for use in temp. un-controlled
network floors and many others temp sensitive critical Industrial applications where
above normal room temp. is present in the room the network operates. Full-duplex future
proof fiber media can easily connect long distance subnets and provide a stable secure
network to all applications. The SNMP, QOS management capability of the Magnum
6K8-Series Switch helps create a database of all the network subnets to easily manage
the network and prioritize the sensitive and useful data. The Relay contact for the Alarms
feature operated through software and hardware provides extra reliability to monitor the
switch operation or any power failure.
Magnum 6K8 in a Industrial floor application to monitor and signaling PLC units
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
20
www GarrettCom com
..
Example 2. In another outdoor Ethernet Traffic monitoring application, a managed
network is needed to provide a Redundant ring topology for a maximum redundant
network. This is needed where any faulty cable, cable disconnection or power failure in
a ring switch needs to be reconfigured in milliseconds . The ring topology of the network
consists of high speed LAN segments supported by 100Mbps full-duplex future-proof
fiber media to provide secure long distance LAN connections. The entire network is
sharing a higher bandwidth of multicast packets used for secure camera monitoring and
data-mining for the vital database located in a controlled center secured building. The
entire spread network will be manageable to provide easy, detectable, uninterrupted
support through a viewable SNMP monitor.
The NEMA TS-2 and TEES along with IP53 approval with the mix of copper
and fiber ports on the 6K8-Series Industrial Field Switch provides an economical and
seamless solution to the requirements. The user-configurable Magnum 6K8 provides an
extra boost to the network requirements by providing copper/fiber media along with the
higher bandwidth support of 10/100Mbps. The user can utilize the SNMP feature
equipped with 802.1Q VLAN, RMON, RSTP and other standard managed LAN features
to provide a secure and stable network.
The 6K8-Series Industrial Field with S-ring and Link-Loss-Learn feature easily
fulfilled the redundancy requirement in a secure and fast reconfiguration time for cable
breakup by setting up a ring topology.
Fig. 2.4b-Magnum 6K8 equipped with S-Ring in redundant ring in a outdoor Traffic application
Interne
Route
Magnum 6K25
CCTV
CCTV
CCTV
CCTV
CCTV
Control Center
SNMP Monitor
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
21
www GarrettCom com
..
Example 3
:
In another example, a large Power Substation (Electric and Gas) needs a
Secure Ethernet LAN network to collect, monitor and provide a simplified
communications backbone for local and remote control of real-time operational and fault
analysis data. The Ethernet backbone should pass the information of SCADA local
monitoring and control via a HMI. The heart of the system evolves around several
communications processors.
The Hardened enclosed 6K8-125VDC Industrial field switch with IEEE 1613
and IEC61850 approved for power stations is equipped with its modularity, secured
management features, un-controlled temp ratings along with a hardware/software
controlled Alarm Relay which easily qualifies it to provide all the requirements of
substations.
The successful track record of previous members of the 6K-family in sub-
stations also adds another example of success for this product to deploy in sub-station
environments. The combination of 6K25 as the back bone and 6K8 at the edge provides a
seamless secure solution which can easily monitor real-time operations. Enriched with
Fiber and copper options make this switch ready to provide this solution and also control
any emission noises via a fiber approach.
Magnum 6K8 Industrial Field switch in a Power Substations applications
Event Monitor
Interne
Route
Magnum 6K25
Control Center
SNMP Monitor
SCADA
HMI Monitor
Comm. processor
Comm. processor
Comm. processor
Comm. processor
Comm. processor
Comm. processor
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
22
www GarrettCom com
..
3.0 Installation
Before installing the equipment, please note the following UL/CSA60950 product safety listing requirements.
1)The external power supply for 24VDC units shall be a Listed, Direct Plug In power unit, marked Class 2, or a Listed ITE Power Supply, which has a suitably rated output voltage (i.e. 24VDC), and suitably rated output current.
Mounting Instructions -
A) Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer.
B) Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of airflow required for safe operation of the equipment is not compromised.
C) Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading.
D) Circuit Overloading - Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on over current protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
E) Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit (e.g. use of power strips).
F) Replacement of fuses should be only by qualified service personnel.
G) A readily accessible disconnect device shall be incorporated in the building installation wiring.
H) When connected to a 48 V centralized dc source, this product is to be installed only in Restricted Access Areas (Dedicated Equipment Rooms, Electrical Closets, or the like)
and shall be provided with a Listed 5 A DC fuse or circuit breaker in the supply circuit.
This section describes installation of the Magnum 6K8-Series Switches, as well as connection of the various Ethernet media types.
3.1 Locating Magnum 6K8-Series Switches
For vertical panel mounting and wall mounting, see Section 3.4.
For vertical DIN-Rail mounting, see Section 3.3.
For DC power options, see Appendix B. For Dual Source, see Appendix C.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
23
www GarrettCom com
..
For AC power input, locate an AC receptacle that is within six feet (2 meters)
of the intended Magnum 6K8-Series site. The rugged metal case of the Magnum 6K8-
Series will normally protect it from accidental damage in a lab or workplace setting.
Maintain an open view of the front to visually monitor the status LEDs. Keep an open
area around the unit so that cooling can occur from convection while the unit is in
operation. The 6K8-Series has no fans, so it is silent when in operation. Internal
electronics use the case as a heat sink, so the unit may normally be quite warm to the
touch.
3.2 Connecting Ethernet Media
The Magnum 6K8-Series Switches are specifically designed to
support all standard Ethernet media types within a single Switch unit. This is
accomplished by using a family of different port Modules which can be
individually selected and configured per-port. See Section 2.4 for a description
of the PMs.
The various media types supported along with the corresponding IEEE
802.3, 802.3D, 802.3u, 802.3AB and 802.3z standards and connector types are
as follows:
IEEE Standard
Media Type Max. Distance Port Module
Fiber:
1000BASE-FX
m
m
1
Fiber
220m ( ft)
GBIC-SXSC
sgl.m
2
Fiber 5,10,25,70Km
GBIC-LXSC
100BASE-FX
m
m
1
Fiber
2.0km (6,562 ft)
6K6-MSC, -MST
sgl.m
2
Fiber 18.0km (95K ft)
SSC, SSCL
small form factor
m
m
1
Fiber
2.0km (6,562 ft)
6K8-MTRJ, -MLC
small form factor
sgl.
m
1
Fiber
15 km
6KP8V- SLC
Copper:
10BASE-T,100BASE-TX twisted pair 100m (328 ft)
6K8-RJ45
1000BASE-TX GBPM-RJ45
1
mm = multi-mode
2
sgl.m = single-mode
3.2.1 Connecting Fiber Optic ST-type, “twist-lock”
The following procedure applies to installations using a PM with ST-type fiber
connectors. This procedure applies to ports using a 6K8-Series module, MST­type port.
1. Before connecting the fiber optic cable, remove the protective dust caps from the tips of the connectors on the PM. Save these dust caps for future use.
2. Wipe clean the ends of the dual connectors with a soft cloth or lint-free lens tissue
dampened in alcohol. Make certain the connectors are clean before connecting.
Note: One strand of the duplex fiber optic cable is coded using color
bands at regular intervals; you must use the color-coded strand on the
associated ports at each end of the fiber optic segment.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
24
www GarrettCom com
..
3. Connect the Transmit (TX) port (light colored post) on the Magnum PM to the Receive (RX) port of the remote device. Begin with the color-coded strand of the cable for this first TX-to-RX connection.
4. Connect the Receive (RX) port (dark colored post on the PM) to the Transmit (TX) port of the remote device. Use the non-color coded fiber strand for this.
5. The LINK LED on the front of the PM will illuminate when a proper connection has been established at both ends (and when power is ON in the unit). If LINK is not lit after cable connection, the normal cause is improper cable polarity. Swap the fiber cables at the PM connector to remedy this situation.
3.2.2 Connecting Fiber Optic SC-type
, "Snap-In"
The following procedure applies to installations using a PM with SC-type fiber connectors, i.e., using 6K-MSC, 6K-SSC single-mode. While connecting fiber media to SC connectors, simply snap the two square male connectors into the SC female jacks of the 6KPM module until it clicks and secures.
3.2.3 Connecting Single-Mode
Fiber Optic
When using single-mode fiber cable, be sure to use single-mode fiber port connectors. Single-mode fiber cable has a smaller diameter than multi-mode fiber cable (9/125 microns for single-mode, 50/125 or 62.5/125 microns for multi-mode where xx/xx are the diameters of the core and the core plus the cladding respectively). Single-mode fiber allows full bandwidth at longer distances, and may be used to connect 10 Mb nodes
up to 10 Km apart, or 18Km with the 6K-SSC.
The same procedures as for multi-mode fiber, applies to single-mode fiber connectors. Follow the steps listed in Section 3.2.2 above.
3.2.4 Connecting Twisted Pair (RJ-45, CAT3, CAT5, Unshielded or Shielded)
The RJ-45 ports of the Magnum 6K8-Series can be connected to the following two media types: 100BASE-TX and 10BASE-T. CAT 5 cables should be used when making 100BASE-TX connections. When the ports are used as 10BASE-T ports, CAT 3 may be used. In either case, the maximum distance for unshielded twisted pair cabling is
100 meters (328 ft).
Media IEEE Standard Connector
Twisted Pair (CAT 3, 4, 5) 10BASE-T RJ-45
Twisted Pair (CAT 5) 100BASE-TX RJ-45
NOTE : It is recommended that high quality CAT. 5 cables (which work for both 10 Mb
and 100Mb) be used whenever possible in order to provide flexibility in a
mixed-speed network, since dual-speed ports are auto-sensing for either 10 and
100Mb/s.
The following procedure describes how to connect a 10BASE-T or 100BASE­TX twisted pair segment to the RJ-45 port. The procedure is the same for both
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
25
www GarrettCom com
..
unshielded and shielded twisted pair cables.
1. Using standard twisted pair media, insert either end of the cable with an RJ-45 plug into the RJ-45 connector of the port. Note that, even though the connector is shielded, either unshielded or shielded cables and wiring may be used.
2. Connect the other end of the cable to the corresponding device
3. Use the LINK LED to ensure proper connectivity by noting that the LED will be illuminated when the unit is powered and proper connection is established.
4. The auto-cross(Auto-MDIX) feature will eliminate the use of crossover cable, while connecting the RJ-45 ports to any other RJ-45 device.
3.2.5 Connecting Twisted Pair (CAT5E or better, Unshielded or Shielded)
The RJ-45 Gigabit ports of the Magnum 6K8-Series can be connected to the media types, 1000BASE-T or CAT 5E or better 100-ohm UTP or shielded twisted pair (STP) balanced cable. The CAT 5E or better 100-ohm UTP or shielded twisted pair (STP) balanced cable is recommended to use when making 1000BASE-TX connections.
In either case, the max distance for unshielded twisted pair cabling is 100 meters (328 ft).
Media
IEEE Standard Connector
Twisted Pair (CAT 5E) 1000BASE-T RJ-45
NOTE : It is recommended that high quality CAT. 5E cables (which work for both 100
Mb and 1000Mb) be used whenever possible in order to provide flexibility in a
mixed-speed network.
The following procedure describes how to connect a 1000BASE-T twisted pair segment
to the RJ-45 port. The procedure is the same for both unshielded and shielded twisted
pair cables.
1. 1000Base-T connections require that all four pairs or wires be connected. Insert either end of the cable with an RJ-45 plug into the RJ-45 connector of the port. Note that, even though the connector is shielded, either unshielded or shielded cables and wiring may be used.
2. Connect the other end of the cable to the corresponding device
3. Use the LINK LED to ensure proper connectivity by noting that the LED will be
illuminated when the unit is powered and proper connection is established
3.2.6 Connecting Gigabit Media Using GBICs
The Gigabit ports accept industry-standard GBICs for user selection of the gigabit media type desired. A selection of fiber and copper GBICs are available.
3.3 DIN-Rail Mounting
The Magnum 6K8 is designed for use in a “factory
floor” industrial environment. It is available with optional
DIN-Rail brackets to mount it securely in a metal factory
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
26
www GarrettCom com
..
floor enclosure, maintained vertically for proper convection cooling of the unit. The
Magnum 6K8 requires two DIN-Rail mounting clips or latches for secure mounting, and
these may be ordered as Model # DIN-RAIL-6K8. See a 6K8 viewed from the rear, at
right, with model DIN-RAIL-6K8 in place on the unit.
The Din Rail Latching clips are mounted on the
upper rear corners of the 6K8 unit. Two threaded
holes are provided on the sides of 6K8 for DIN-
Rail mounting purposes. See side view at the left,
with the top of the unit pointed to the right. The
required two screws are included with the DIN-
Rail brackets, and are no.10-32 X 3/8 PHIL. PAN
w/star washer. The two heavy duty Din-Rail
latches are designed as if that they can be manually accessed from the top when the 6K8
is installed on a DIN Rail.
To install the 6K8 with the DIN-Rail brackets and latches attached to it, hold the
6K8 in the vertical position with the bottom out, and with the top moved in toward the
DIN-Rail. Position the latches over the top of the DIN-Rail. Then, snap the latches into
holding position by moving the bottom of the 6K8 inwards to a vertical position. The
DIN-Rail latches and brackets are heavy duty, and will hold the 6K8 securely in position,
even with cabling attached to the unit.
To release the 6K8 from the DIN-Rail mounting, press the top of the two DIN-
Rail latches down simultaneously to release the 6K8 so that it can be dismounted by
pulling the bottom out. Once the bottom of the 6K8 is rotated out, the DIN-Rail latch is
not engaged and the 6K8 can be moved up and out, free of the DIN-Rail mounting..
The picture below is a front / right-side view of a DIN-Rail mounted 6K8. It
shows vertical mounting of Magnum 6K8 on a DIN-Rail track for proper convection
cooling of the unit. Note that there is air space in the rear, as the 6K8 unit is held out
from the rear of the panel by the mounting brackets. The 6K8 design uses the case for
cooling (patent pending), and needs to be mounted vertically with air flow space in the
front, rear, and sides.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
27
www GarrettCom com
..
Fig 3.3 - Magnum 6K8 mounted vertically with DIN-Rail brackets and latches
The DIN-Rail mounting brackets and latches are optional and need to be ordered as separate items, e.g Model # DIN-
RAIL-6K8
3.3.1 Installing DIN-RAIL
variable brackets on Magnum 6K8
Magnum 6K8 Din-Rail kit comes along with the following-
BOM:
Item Quantity Description
1 1 DIN Rail Clip assy 2 2 #10-32 x ¼ Phillip Flat head screws with undercut
3 8 #4-40 x 3/8 Phillip Flat head screw
Din-Rail kit Installation procedures:
1. Remove the back plate from Magnum 6K8 UNIT a. There are eight screws along the edge of the unit to remove. b.. Do not re-use the old screws.
2. On the back-plate a. Locate the indented side with 1, 11……
b. “1” indentation signify center of the mounted Din-Rail clip
location.
c. Each indented locations (1-11-111…) are ½ inches apart from the center.
Fig 1.
3.
Select the height position via
indented side marking .
4. Place the
DIN Rail Clip assembly under indented side of the plate. Place two of the screws, came along the kit (#10-32 x ¼ Phillip Flat head screws with undercut) onto the indented side and screw tight the assembly as shown in Fig 2a. Note: Make sure the screws must have the 5lbs/in torque minimum.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
28
www GarrettCom com
..
a. The Din-Rail clip must be on top, while positioning the clip as shown in Fig. 2b with arrow mark.
Fig. 2a: 10-32 Screws on indented side Fig. 2b: Din-Rail assembly w/plate applied to mount the Din-Rail assembly underneath.
5.
Remount the Din-Rail assembled plate onto the Magnum 6K8, using the 4-40 screws.
Note: Torque 5lb/in max. on the 4-40 screws while tightening the screws.
The final Din-Rail assembly mounted on the Magnum 6K8 is shown below on Fig. 3
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
29
www GarrettCom com
..
Fig . 3
3.3.2 Mounting Dimensions for 6K8 with metal brackets
Each Mangum 6K8 is supplied with metal mounting brackets and screws to mount the unit securely. It is recommended to mount the 6K8 vertically, as shown below, for proper cooling and long-life reliability. It is also advisable to mount the unit with space for air movement around the top and the sides, typically a minimum of 1 inch..
Note that the back of the 6K8 unit is held out from the panel or wall behind it, creating a rear space of about ¼ inch or 1cm. This allows air circulation and cooling of the rear part of the case. Since the 6K8 uses special internal thermal techniques (patent pending) to move the heat generated by the electronic components inside into the case, the case may be quite warm to the touch during normal operation.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
30
www GarrettCom com
..
The unit can be mounted using the brackets turned outside (normal) or inside (if space is tight). Attach the mounting bracket either outside or inside as shown in the illustration above (dotted line shown for the brackets inside). The spacing for the mounting screws into the supporting wall or panel is a rectangle 11.89” x 7.85” center-to-center.
3.4 Powering the Magnum 6K8-Series Industrial Field Switch
The Magnum 6K8-Series Switches incorporate an internal universal power
supply and have a recessed male IEC connector for the AC power cord at the left-rear. A
manual power ON-OFF switch is adjacent. A six-foot 115 VAC 60 Hz standard power
cord is supplied with each unit shipped within the United States and Canada.
The auto-ranging power supply supports installation environments where the
AC voltage is from 90 to 260 volts with a power input frequency between 47 and 63 Hz.
The 16-port units will consume over 20 watts of power typically. When connecting the
Ethernet cabling, there is no need to power down the unit. Individual cable segments can
be connected or disconnected without concern for AC power-related problems or damage
to the unit.
Power supply options are available to suit the 6K8-Series Switches to special
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
31
www GarrettCom com
..
high-availability communications and/or heavy industrial-grade applications, including:
* -48VDC, 24VDC and 125VDC with single DC input,
* -48VDC, 24VDC and 125VDC with dual-source DC input,
See the Appendices B & C of this manual for more details. Use an RFQ for other
variations.
3.5 Alarm Contacts for monitoring internal power, and Software Traps
The Alarm Contacts feature, standard on Magnum 6K8-Series’s, provides
two Form C Normally Closed (NC) contacts to which the user can attach two sets of
status monitoring wires at the green terminal block. When this option is present, the
terminal block for Alarm Contacts is part of the Power Input panel in the Magnum 6K8-
’s case. The AC or DC power input connection is in the same panel. A manual On-Off
Switch for power to the unit is not available on 6K8- units with the Alarm Contacts
option, as these two features occupy the same space in the case.
The first NC Alarm Contact (top position) is a “Software Alarm”, operated
by user settings in the MNS-6K software. The user can disable the Software Alarm
feature with a software configuration command if desired. When
the Software Alarm is enabled, the Form C Normally Closed
(NC) contact is held close during normal software operation. A
user-defined software malfunction, such as an SNMP Trap or a
Software Security violation or an S-Ring Fault, causes the contact
to open and thus trigger an alarm in the user’s monitoring system
The second (bottom position) NC Alarm Contact is
held close when there is power on the main board inside of the
6K8-. This provides a “Hardware Alarm” because the NC
contacts will open when internal power is lost, either from an
external power down condition or by the failure of the power
supply inside of the Magnum 6K8- Switch. Useful info. about Alarm contacts:
1. There is four terminal block (1,2,3,4) provided next to AC/DC power supply
2. The top two pins (1,2) are software operated
3. The bottom two pins (3,4) are hardware operated
4. By default it is NC (normally closed)
5. The software operation needs to be enabled and set to get the Alarm traps. For detail
information about the Software Alarm and software control of SNMP alarm traps, please
reference the Magnum MNS-6K Software User Manual. (Chapter 19th).
The Alarm Contact is on the front left area (next to the DC power source) of
the Magnum 6K8-Series unit and is green in color as shown in the picture.
3.6 6K8-Series Port Module (6KPMV) Installation
Note: The modules used in the 6K8-Series vertical mount unit are similar to
those used in 6K16V units. The modules have the letter “V” in the model numbers, to
order the right module for this unit. In the Port Module materials below, all modules are
Relay Contacts
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
32
www GarrettCom com
..
referred to as “6KPMV” for convenience in describing port module installation.
Magnum 6K8-Series Switches are normally received from the factory with all
required 6KPMV modules installed. There may be situations where 6KPMV cards need
to be added or replaced. In cases where additional 6KPMV cards are needed, the
faceplate for an available front-mounted slot must be removed. The following procedure
describes this operation. The pictorial view of the hardware assembly can be seen here-
http://www.garrettcom.com/Pictorial/6k8_pictorial.pdf
3.6.1 Preparation for Installing and Removing 6KPMVs from 6K8’s
STOP!!!
Be sure the power cord is unpl ugged
from the chassis before attempting to remove
and/or replace any PM cards.
Failure to do so may result in damage to the unit
and will void the warranty.
Caution- Avoid Static Discharge: The port modules (like most electronic equipment) are sensitive to static dischar g e. Use proper ESD measures when handling port modules.
Step 1. Make sure the 6KPMV Card package has all necessary accessories and use the
proper tool to install it properly. Each 6KPMV Card package, for field
installation contains (Daughterboard (Bigger) and Granddaughter board
(smaller), three 5/8 stand offs for Granddaughter board, 6 standoff for daughter
Board, nine #4-40x3/8 Pan-Head screws along with Front panel face plate
package.
NOTE: Every 6KPMV Card package comes with their matching Daughter and Granddaughter board. The copper 6KPMV card should not work properly if mixed with other Fiber combo 6KPMV card packages. Always install the PM module separately one by one to avoid the mixing.
Do not change the Blue color DIP Switch setting ever! Leave it at factory default. Step 2. Remove Chassis Cover
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
33
www GarrettCom com
..
The Magnum 6K8-Series chassis consists of top cover and bottom chassis assembled together with the help of 12 Philips-head screws. There are 4 screws located on the top-side panel of the unit (2 each on both side), 8 for bottom chassis base of the unit. Remove these screws. Once these screws are removed, the top-cover is easily slide out to the front, off the chassis base, as shown in the picture above in Fig. 3.6.1a.
Figure 3.6.1a: Removing the Top panel from the Chassis base of the unit
Caution: Be careful not to disturb the power supply.
When the chassis top cover has been removed, the interior of the unit is
exposed. Looking down into the Magnum 6K8-Series unit, notice that there are PM
module installed and daughter module would be facing your eyes on the top installed on
the main board with J5 and DSSV pins connected on the right. (See Figure 3.6.1b)
below.
Figure 3.6.1b:
Magnum 6K8-Series,
Top view without
chassis cover w/
daughter module on the
top.
Note: Un-hooked the J5and DSSV connected wires first as shown in Figure above with arrow mark.
Step 3. Remove front panel face plate retaining screws and screen plate
There are four retaining screws as shown with
arrow mark in Fig 3.6.1c holding the face plate of
the chassis.
Figure 3.6.1c: Top View – 6KPM retaining screws hold Face Plate
Daughter boar
d
Power LED, Pin J5
Power Supply, Pin DSSV
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
34
www GarrettCom com
..
Once opened all the four retaining screws the
front cover can be removed easily as shown in Fig
3.6.1d. on the left.
Figure 3.6.1d: Removing Face Plate
Carefully remove the PM screen plate using finger or small screw driver to come out easily as shown in Fig
3.6.1d on the right. Just be careful on the LEDs placed both side and hold the face plate tightly. There are no screws used on holding the screen
face plate
.
Figure 3.6.1d: Removing PM screen Plate
3.6.2 Installing 6KPM Cards in the Magnum 6K8-Series
Only one front-mounted 6KPMV Module may be installed in one Magnum
6K8-Series Field Switch unit. Follow these steps to install a 6KPMV.
Step 1. Remove top chassis cover. See procedure in Section 3.6.1 above.
Fig 3.6.2a A Magnum 6K8 unit with main board(motherboard) only
Step 2. Place Granddaughter
board (as shown in fig. 3.6.2b)
on the chassis built in stand off
(female) provided at the front of
the 6K8-Series Main Board. To
place the Granddaughter board
on the chassis, as shown in
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
35
www GarrettCom com
..
Figure below 3.6.2c, screw down tightly with the three 5/16 stand-off (male) on the top
of the Granddaughter board. The three 5/16 stand off has been used to place the daughter
board on the top of the granddaughter board and a latch connector to hold it securely.
Fig 3.6.2b Granddaughter
Board shown separately Fig 3.6.2c Granddaughter Board placed in slot & secured with three 5/16 standoff’s
Step 3. The figure here illustrates the basic layout of an individual PM card. Each
6KPM card fits into the space provided on the main board.
Fig. 3.6.2d Daughter Board, top view of
4 copper 10/100 ports Fig 3.6.2e Daughter Board shown upside down with two
male latch connectors Step 4. Hold the daughter board with both hands at the
end and insert the 6KPMV module inside the front face plate slot carefully. Then align
the two cream color latching connectors (male) placed at the bottom of the daughter
board with the other female connector placed on the Granddaughter and main board. As
shown below in Fig. 3.6.2f.
Fig. 3.6.2f Magnum 6KPM daughter board aligned with the bottom latch connector after inserted properly in front plate slot
Female latch connector
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
36
www GarrettCom com
..
Step 5. Once the latching connectors are aligned properly and the mounting holes are
aligned with stand offs then press slowly and firmly with two fingers (as shown
below in Fig. 3.6.2f) on the top of the latching connectors until the connectors latched up securely.
Figure 3.6.2f:
Securely
latching up
6KPMV Cards into a Magnum 6K8-Series
Step 6. Now screw down the daughter board with 6 #440 screws,
so that it holds the daughter board securely. The figure on
the left shows the top view of successfully installed
6KPMV cards inside and the Power Led(pin J5) and Power supply cable(pin DSSV) connected to the board pins as shown in Fig 3.6.2g with arrows.
Fig. 3.6.2g Top View: 6KPM Module installed and insight for connecting two wires to the right pins
Step 7. Once the installation of granddaughter and
daughter modules is done, the front panel
screen plates of 6KPMV need to be placed
on the face of the module securely and carefully. Now screw down properly the
J5
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
37
www GarrettCom com
..
face plate with 4 screws to complete the installation process for port module.
The front panel screen plate does not need any screws to hold on port module,
but need to place tightly and carefully while placing on LEDs.
Step 8. Once 6KPMV card have been installed (including faceplate and screen plate),
the chassis cover should be replaced. Make sure the chassis top cover is aligned
properly to the base before securely sliding the chassis base track inside the top
cover properly as shown in
Fig 3.6.2h
Fig. 3.6.2h sliding in the top cover onto the chassis base track
3.6.3 Removing 6KPM Cards
To properly remove a 6KPM card from the 6K8-Series Industrial Field Switch,
follow the 3 steps below.
Step 1. Remove chassis cover See procedures in Section 3.6.1 above.
Caution: Be sure the power cord i s unplugged.
Step 2. Remove retaining screws placed on top of the 6KPMV and Face Plate
Each 6KPMV module is
secured with nine retaining
screws #440x3/8. These screws
are used to secure a 6KPM
card in position (see Figure
3.6.3a). Remove the 9 screws
to take off the daughter module
and thereafter three standoffs
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
38
www GarrettCom com
..
underneath holding the Granddaughter board with the chassis. Figure 3.6.3a: 8 retaining screws shown by arrows
Step 3. Remove 6KPM Card
Carefully and gently pull out the daughter board from the latching connectors,
using both hands, gripping the board near the latch-up connectors as shown in Fig. 3.6.3b
Figure 3.6.3b: Removing a 6KPM Card
All the same procedures will
apply for replacing any
6KPMV module from 6K8-
Series managed switches.
Follow the steps as described
for installing a 6KPMV card
discussed in step 3.7.1.
3.7 Connecting a Management Console Terminal to Magnum 6K8
Use a DB-9 “null modem” cable (use on any serial port)or “one DB-9 and one USB” ( USB port on the laptop) null modem cable to connect the Magnum6K8-Series Console Port (the RS-232 port on the 6K8-Series Switch) to the your PC, so that your PC becomes the 6K8-Series’s Console Terminal. For Hyper terminal configuration to communicate with 6K-Series Switches, please follow the “Quick Step Guide” come along with the Switch.
http://www.garrettcom.com/techsupport/software/upgrade_mns6k.pdf
Note: A console cable (either of the two types) may be purchased as a separate item with the 6K8-Series unit. They ar e not “bundled” with the unit.
Fig 3.7 Enlarged view of Magnum 6K8-Series Console Port area
Note: For a detailed description of Managed Network Software (MNS-6K) and Magnum 6K8-Series Switch configuration for Network Management, please refer to
Consoleor Serial. (DB-9) Port
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
39
www GarrettCom com
..
Magnum 6K8-Series Software Manual available on GarrettCom‘s FTP site. Please refer Section 2.2.9 of this manual for download information.
3.7.1 RS-232 (DB-9) Console Com port (Serial port) pin assignments.
Pin 1 Pin 5
DB-9 (Console port connector)
Pin Signal Description
1 CD Carrier detect (not used) 2 RXD Receive Data (input) 3 TXD Transmit Data (output) 4 open not used 5 GND Signal Ground 6-9 open not used
The above information enables a management station ( a PC or Console terminal) to connect directly to the Switch Console using a straight-through serial cable
.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
40
www GarrettCom com
..
4.0 OPERATION
This chapter describes the functions and operation of the Magnum 6K8-Series
Switch.
4.1 Switching Functionality
A Magnum 6K8-Series provides switched connectivity at Ethernet wire-speed
among all of its ports. The Magnum 6K8-Series supports10/100Mbs for copper media
and 10 or 100Mb separate traffic domains for fiber ports to maximize bandwidth
utilization and network performance. All ports can communicate to all other ports in a
Magnum 6K8-Series, but local traffic on a port will not consume any of the bandwidth
on any other port.
Magnum 6K8-Series units are plug-and-play devices. There is no software
configuring necessary to be done for basic operation at installation or for maintenance.
The only hardware configuration settings are user options for an UP-LINK Switch
(resides inside the unit) on the 6K8-RJ45. Optional Half / Full duplex mode and 10 or
100Mbps selection for the switched ports must be configured through MNS software per
unit as per the requirement. The internal functions of both are described below.
Filtering and Forwardi ng
Each time a packet arrives on one of the switched ports, the decision is taken to
either filter or to forward the packet. Packets whose source and destination addresses are
on the same port segment will be filtered, constraining them to that one port and relieving
the rest of the network from having to process them. A packet whose destination address
is on another port segment will be forwarded to the appropriate port, and will not be sent
to the other ports where it is not needed. Traffic needed for maintaining the un-
interrupted operation of the network (such as occasional multi-cast packets) are
forwarded to all ports.
The Magnum 6K8-Series Switches operate in the store-and-forward switching
mode, which eliminates bad packets and enables peak performance to be achieved when
there is heavy traffic on the network.
Address Learning
All Magnum 6K8-Series units have address table capacities of 4K node
addresses suitable for use in larger networks. They are self-learning, so as nodes are
added, removed or moved from one segment to another, the 6K8-Series Switch
automatically keeps up with node locations.
An address-aging algorithm causes least-used addresses to fall out in favor of
frequently-used addresses. To reset the address buffer, cycle power down-and-up.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
41
www GarrettCom com
..
4.2 Dual LEDs
Status
on TOP and Front of the 6K8-Series unit
PWR/POWER : Power LED, ON when external power is applied to the unit.
LK/LINK : Steady ON, Link status for 10 Mbps and 100Mbps operation. ACT : ON with port activity for 10 Mbps and 100Mbps operation. F/H : Full / Half duplex LED, ON when the port is running full duplex,
OFF for half duplex.
10/100 : Speed LED, ON when the speed is 100Mbps, OFF when the
speed is 10 Mbps
4.3 Auto-Cross(MDIX) and Auto-negotiation, for RJ-45 ports
The RJ-45 ports independently support auto-cross (MDI or MDIX) in auto-negotiation mode and will work properly with all the other connected devices with RJ-45 port whether it supports Auto-negotiation or not (e.g 10Mb Hub, media converter) or fixed mode at 10Mb or 100Mb Half/Full Duplex(managed switch). No cross-over cable is required while using the 6K8’s copper port to other devices. Operation is according to the IEEE 802.3u standard.
The Managed 6K8-Series Fast Ethernet copper ports, can be set for either fixed 100Mb
speed or for 10/100 F/H N-way auto-negotiation per the IEEE802.3u standard. The
selection is made via MNS software. The factory default setting is for auto-negotiation.
At 10Mb or 100Mb-fixed speed, the user may select half- or full-duplex mode by MNS
Software for each RJ-45 port separately. For detail information See Section (10.1 at page no.52) of this manual to access the “6K-MNS(Rel 3) Software user guide”
One frequently-used application for the Managed Magnum 6K8-Series Switch
copper ports is to connect one of them using a fiber media converter to another Switch in
the network backbone, or to some other remote 100Mb device. In this case, it is
desirable to operate the fiber link at 100Mb speed, and at either half- or full duplex mode
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
42
www GarrettCom com
..
depending on the capabilities of the remote device. Standard commercially available
Fast Ethernet media converters mostly do not support auto-negotiation properly, and
require that the switched port to which they are connected be at 100Mb fixed speed.
Attachment to 10/100 auto-negotiation ports typically will not work properly. The 6K8-
Series Switch’s RJ-45 ports handle this situation by configuring the ports as per desire
through MNS software port settings and can check the port status of each port after the
change.
When Magnum 6K8-Series RJ-45 copper ports are set for auto-negotiation and are connected to another auto-negotiating device, there are 4 different speed and F/H modes possible depending on what the other device supports. These are: (1) 100Mb full­duplex, (2) 100Mb half-duplex, (3) 10 Mb full-duplex and (4) 10 Mb half-duplex.
The auto-negotiation logic will attempt to operate in descending order and will normally arrive at the highest order mode that both devices can support at that time. (Since auto­negotiation is potentially an externally controlled process, the original “highest order mode” result can change at any time depending on network changes that may occur). If the device at the other end is not an auto-negotiating device, the 6K8-Series’s RJ-45 ports will try to detect its idle signal to determine 10 or 100 speed, and will default to
half-duplex at that speed per the IEEE standard.
General information -
Auto-negotiation per-port for 802.3u-compliant switches occurs when:
-- the devices at both ends of the cable are capable of operation at either 10
Mb or 100Mb speed and/or in full- or half-duplex mode, and can
send/receive auto-negotiation pulses, and . . .
-- the second of the two connected devices is powered up*, i.e., when
LINK is established for a port, or
-- the LINK is re-established on a port after being lost temporarily.
 NOTE – Some NIC cards only auto-negotiate when the computer system
that they are in is powered up. These are exceptions to the “negotiate at
LINK – enabled” rule above, but may be occasionally encountered.
When operating in 100Mb half-duplex mode, cable distances and hop-counts
may be limited within that collision domain. The Path Delay Value (PDV) bit-times must
account for all devices and cable lengths within that domain. For Magnum 6K8-Series
Fast Ethernet switched ports operating at 100Mb half-duplex, the bit time delay is 50BT.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
43
www GarrettCom com
..
4.4 Flow-control, IEEE 802.3x Standard
Magnum 6K8-Series Switches incorporate a flow-control mechanism for Full-
Duplex mode. The purpose of flow-control is to reduce the risk of data loss if a long
burst of activity causes the switch to save frames until its buffer memory is full. This is
most likely to occur when data is moving from a 100Mb port to a 10 Mb port and the
10Mb port is unable to keep up. It can also occur when multiple 100Mb ports are
attempting to transmit to one 100Mb port, and in other protracted heavy traffic situations.
Magnum 6K8-Series Switches implement the 802.3x flow control (non-
blocking) on Full-Duplex ports, which provides for a “PAUSE” packet to be transmitted
to the sender when the packet buffer is nearly filled and there is danger of lost packets.
The transmitting device is commanded to stop transmitting into the 6K8-Series Switch
port for sufficient time to let the Switch reduce the buffer space used. When the available
free-buffer queue increases, the Switch will send a “RESUME" packet to tell the
transmitter to start sending the packets. Of course, the transmitting device must also
support the 802.3x flow control standard in order to communicate properly during
normal operation.
Note: When in Half-Duplex mode, the 6K8-Series Switch implements a back-pressure
algorithm on 10/100 Mb ports for flow control. That is, the switch prevents frames from
entering the device by forcing a collision indication on the half-duplex ports that are
receiving. This temporary “collision” delay allows the available buffer space to improve
as the switch catches up with the traffic flow. The flow control option may
(enable/disable) through setport command of MSN-6K software as per the requirement of network. By default the Flow control is disabled.
4.5 Power Budget Calculations for Magnum 6K8-Series PM’s with Fiber Media
Receiver Sensitivity and Transmitter Power are the parameters necessary to
compute the power budget. To calculate the power budget of different fiber media
installations using Magnum products, the following equations should be used:
OPB (Optical Power Budget) = P
T
(min) - PR(min)
where P
T
= Transmitter Output Power, and PR = Receiver Sensitivity Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss) Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km] where the “Cable Loss” for 62.5/125 and 50/125
m
(Mm) is 2.8 dB/km, and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km, and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km
and the “Cable Loss” for 9/125 (Single-mode) is 0.4 dB/km (LXSC25) and the “Cable Loss” for 9/125 (Single-mode) is 0.25 dB/km(LXSC40) and the “Cable Loss” for 9/125 (Single-mode) is 0.2 dB/km (LXSC70)
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
44
www GarrettCom com
..
The following data has been collected from component manufacturer’s (Agilent’s and
Lucent’s) web sites and catalogs to provide guidance to network designers and installers.
Fiber
Port
Module
Speed,
Std.
Mode
Std.
km fdx
(hdx)
Wave
-
length
nm
Cable
Size
m
X’mitr
Output
P
T ,
dB
R’cvr
Sens.
P
R ,
dB
Worst
OPB,
dB
Worst* distance Km, fdx
typical
OPB,
dB
typical* distance Km, fdx
6KP4V-
F10ST
10Mb
FL
Multi-
Mode
2
(2)
850
62.5/125
100/140
50/125
-15.0
-9.5
-19.5
-31
-31
-31
14
19.5
19.5
5
5.9
3.4
17
23.5
13.5
6 7
4.8
6KPV-
MST, MSC
100Mb
FX
Multi-
mode
2
(0.4)
1300
62.5/125
50/125
-20
-23.5
-31
-31
9.0
5.5
3.0
2.0
14
12
5 4
6KPV-SSC
100Mb
FX
Single-
mode
18+
(0.4)
1300 9/125 -15 -31 14
28
17.5
35
6KPV-
SSCL
100Mb
FX
Single-
mode
40
(0.4)
1300 9/125 -5 -34 29
58
32.5
65
6KPV-
MTRJ
100Mb
FX
Multi-
mode
2
(0.4)
1300
62.5/125
50/125
-20
-23.5
-31
-31
9.0
5.5
3.0
2.0
15.8
12.2
5.5
4.0
6KPV-
MLC
100Mb
FX
Multi-
mode
2
(0.4)
1300 62.5/125 -19 -31 12
4
16
5.7
6KPV-SLC
100Mb
FX
Single-
Mode
15+
(0.4)
1310 9/125 -15 -28 11
22
-
-
GBIC-
SXSC
1000Mb Multi-
mode
0.55
850 62.5/125
50/125
-9.5 -17 5.5
2
12.5
4
GBIC-
LXSC10
1000Mb Single-
mode
10
1300 9/125 -9.5 -20 8.5
17
10.5
21
GBIC-
LXSC25
1000Mb Single-
mode
25
1550 9/125 -4.0 -21 15
37.5 17.5
43
GBIC-
ZXSC40
1000Mb Single-
mode
40
1550 9/125 -4.0 -21 15
60 17.5
70
GBIC-
ZXSC70
1000Mb Single-
mode
70
1550 9/125 -3.0 -23 18
90 20.5
102
* Note: The use of either multi-mode or single-mode fiber to operate at 100Mbps speed over long distances (i.e., in excess of approx. 400 meters) can be achieved
only
if the
following factors are both applied:
 The 100Mb fiber segment must operate in full-duplex (FDX) mode, i.e. the
full-duplex (factory default) setting for 100Mbps fiber ports must be used, and
 The worst-case OPB of the fiber link must be greater than the fiber cable’s
passive Attenuation.
(Attenuation = Cable loss + LED aging loss + Insertion loss + safety factor)
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
45
www GarrettCom com
..
5.0 Introduction - Magnum 6K8 Industrial Field Switch Port Modules
This chapter describes each Port Module (PM), including appearance,
functionality, and status displays.
5.1 Inspecting the Package and Product
This section applies only to PMs shipped as separate items, i.e., if 6K8 PMs not
factory installed in a Magnum 6K8 PM slot.
Examine the shipping container for obvious damage prior to
installing a 6K8 PM; notify the carrier of any damage you believe occurred
during shipment or delivery. Inspect the contents of this package for any signs
of damage and ensure that the items listed below are included.
This package should contain:
1 6K8-Series (6K8- series KPMVs)
Installation instructions, with illustrations
Remove the 6K8-Series PM(s) from the shipping container. Be sure
to keep the shipping container should you need to ship any of the PMs
separately at a later date. In the event there are items missing or damaged,
contact your supplier. If you need to return the unit, use the original shipping
container if possible. Refer to Chapter 5 for specific return procedures.
5.2 6KPMV Module Description
An important feature of the Magnum 6K8-Series is the use of Port Modules for
flexible mixed-media connectivity to RJ-45 and fiber media. Since the Magnum
6K8-Series Switches have dual-speed capability for copper ports, the 2, 4, 6 or
8-port interfaces are designed to support all standard Ethernet media types at 10
or 100 or 1000Mps speed. Each 6K8-Series PM provides a wide selection of
connecting Ethernet media segments with all similar or combo connector type.
Note: The 6K8V Port modules are exactly similar in the functions, size and price,
compared to 6K8- but addressed as e.g 6KP8V-RJ45 . For a correct list of 6K8 Port Module types, refer to Section 1.2
Each 6K8-Series PM is individually described in the following sections.
NOTE:
The 10/100 RJ-45 ports on all the modules, either all RJ-45 ports or used for COMBO module are featured with Auto-negotiation and Auto-Cross (MDIX).
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
46
www GarrettCom com
..
5.2.1 6KP6-RJMST, 4@10/100Mbps RJ-45 and 2@100Mb multi-mode FX-ST “twist lock” Combo Module
The Magnum 6KP6-RJMST is a combo 6 port module of four RJ-45’s at
10/100Mbps and two fiber optic ports at 100MB. The Combo module is equipped with
dual-mode ST-type connectors
and dual speed copper ports.
The ST-connector functions as
a fiber optic transceiver to
support 100BASE-FX network
segments. When installed in a
Magnum 6K8-Series Managed
Switch, the copper port
supports the standard distance
100m on each port and the fiber
port supports fiber optic cable distances up the IEEE-standard 100Mbps distance limits,
i.e., typically 2km at full-duplex and 412m at half-duplex.
Each port has an Activity (ACT) LED indicating packets being received, a
Link (LK) LED that indicates proper connectivity with the remote device when lit, and
FDX/HDX LED to indicate full-duplex mode when lit (or half-duplex when off). The
10/100 LED indicates the speed, if the LED is ON 100Mbps if it is OFF 10Mbps.
5.2.1a 6KP6-RJ10ST, 4@10/100Mbps RJ-45 and 2@10Mb multi-mode FX-ST “twist lock” Combo Module
The 6KP6-RJ10ST is a six port combo module that looks similar to the 100Mb combo module with the exception of 10Mb speed at the ST fiber module. The ST-connector functions as a fiber optic transceiver to support 10BASE-FX network segments. When installed in a Magnum 6K8-Series Managed Switch, the copper port supports the standard distance 100m on each port and the fiber port supports fiber optic cable distances up the IEEE-standard 10Mbps distance limits, i.e., typically 2km at full­duplex and half-duplex.
Each port has an Activity (ACT) LED indicating packets being received, a Link (LK) LED that indicates proper connectivity with the remote device when lit, and FDX/HDX LED to indicate full-duplex mode when lit (or half-duplex when off). The 10/100 LED indicates the speed, if the LED is ON, 100Mbps if it is OFF, 10Mbps.
4
FULL/HALF
1
ACTIVITY
LINK
2
4
3
3
10/100
1 3 5 7
2 6TX RX
TX LK RX
LK
ACT F/H
ACT F/H
10/100
LK
F/H
ACT
2
1
6KP6-RJMST,
4 Port@ 10/100Mbps and 2 @100 Mb ST Fiber Port
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
47
www GarrettCom com
..
6KP4-RJ10MST,
4 Port@ 10Mb ST Fiber Port
2 6
T
LK RX
ACT F/H
TX RX
LK
ACT F/H
TX RXLK
ACT F/H
TX RXLK
ACT F/H
1 5
3
2
1
FULL/HALF
1
ACTIVITY
LINK
2
3
6KP4-RJ10MST,
4 Port@ 10Mb ST Fiber Port
2 6
T
LK RX
ACT F/H
TX RX
LK
ACT F/H
TX RXLK
ACT F/H
TX RXLK
ACT F/H
1 5
3
2
1
FULL/HALF
1
ACTIVITY
LINK
2
3
5.2.1b 6KP4-F10ST, 4@10Mb multi-mode FX-ST “twist lock” Module
The Magnum 6KP4-F10ST
is a 10Mb multi-mode
fiber module with 4 ST-
Fiber ports. All four fiber
ports are ST connectors
and configured as 10Mb
Half-duplex by default.
The 10Mb ST-fiber ports
allow the user to connect
their legacy 10Mb network
to the Magnum 6K8-Series
switch. They also provide a convenient way for the half duplex
hub to connect to the switch through 10Mb fiber ports. It supports distances according to
the 10Base-FL standard i.e, 2Km distance for multi-mode fiber. (Single-mode for 10Km
distance may be available as a special order).
Each port has an Activity (ACT) LED indicating packets being
received, a Link (LK) LED indicating proper connectivity with the remote device when
lit, and FDX/HDX LED indicating full-duplex mode when lit (or half-duplex if off).
5.2.1c 6KP4-FLSTFX, 2@10Mb & 2@100Mb multi-mode FX-ST “twist lock” Module
The Magnum 6KP4-
FLSTFX is a combo fiber
module with two 10Mb +
two 100Mb multi-mode
fiber module and in
combine 4 ST-Fiber ports.
All four fiber ports are ST
connectors and configured
as 10Mb Half-duplex by
default for 10Mb fiber and
100Mb Full duplex for the
100Mb fiber. The 10Mb ST-fiber ports allow the user to connect their legacy 10Mb
network to the Magnum 6K8-Series switch. They also provide a convenient way for the
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
48
www GarrettCom com
..
half duplex hub to connect to the switch through 10Mb fiber ports. Whereas the 100Mb
ST fiber module, allow to connect the 100Mb demand of Switch devices. It supports
distances according to the 10Base-FL standard i.e, 2Km distance for multi-mode fiber.
(Single-mode for 10Km distance may be available as a special order).
Each port has an Activity (ACT) LED indicating packets being
received, a Link (LK) LED indicating proper connectivity with the remote device when
lit, and FDX/HDX LED indicating full-duplex mode when lit (or half-duplex if off).
5.2.2. 6KP6-RJMSC 4@10/100Mbps RJ-45 and 2@100Mb multi-mode FX­SC “snap-in” Fiber connector
The Magnum 6KP6-
RJMSC is also a Combo 6 Port
module equipped with 4 10/100Mb
RJ-45 ports along with 2 multi-
mode 100Mbps fiber optic
transceivers all in one module. This
is similar to the 6K6-RJMST. It has
the same LEDs indicating port
activity (ACT), Link (LK), and
FDX / HDX and 10/100 operation, and the same face-plate lettering.
While the functionality of these two modules is essentially the same, the 6KP6-
RJMSC is equipped with an SC-type "snap-in" connector instead of an ST-type.
5.2.3 6KP6-RJSSC 4@ 10/100Mbps RJ-45 Ports and 2@100Mbps single-mode FX-SC­type, “snap-in” connector
The Magnum 6KP6-RJSSC
is also a Combo module
equipped with 4 dual speed
copper ports and 2 Single-
mode SC-type connectors. It
provides an advantage
through combining copper
and Fiber functions in one
module of the 6K8-Series Switch supporting four Copper and two single-mode fiber
6KP6-RJMSC,
4 Port@ 10/100Mbps and 2 @100 Mb SC Fiber Port
4
FULL/HALF
1
ACTIVITY
LINK
2
4
3
3
10/100
1 3 5 7
2 6TX RX
TX LK RX
LK
ACT F/H
ACT F/H
10/100
LK
F/H
ACT
2
1
6KP6-RJMSSC,
4 Port@ 10/100Mbps and 2 @100 Mb SSC Fiber Port
4
FULL/HALF
1
ACTIVITY
LINK
2
4
3
3
10/100
1 3 5 7
2 6TX RX
TX LK RX
LK
ACT F/H
ACT F/H
10/100
LK
F/H
ACT
2
1
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
49
www GarrettCom com
..
network segments.
The 6KP6-RJSSC, when installed in a Magnum 6K8-Series Switch operates on
copper at the 100m distance. The Fiber is single-mode and cable lengths can be as much
as 25+ Km (see Power Budget, Section 4.5)
Each port has an Activity (ACT) LED indicating packets being received, a
Link (LK) LED that indicates proper connectivity with the remote device when lit, and a
FDX/HDX LED to indicate full-duplex mode when lit (or half-duplex when off). The
10/100 LED indicates 100Mbps speed when lit and at 10Mbps speed when off. To
distinguish the single-mode 6 K6-RJSSC from the multi-mode 6K6-RJMSC, the label
“Sgl. M.” is at the top of the faceplate of the 6K6-RJSSC.
5.2.4 6KP6-RJSSCL 4 @ 10/100 Mb copper port and 2@100Mbps single-mode FX-SC-type, “snap-in” connector
The Magnum 6KP6-RJSSC is also a Combo module equipped with 4 dual speed copper
ports and 2 Single-mode (Long Reach) SC-type connectors. It provides a combination of
copper and Fiber functions in one module to the 6K8-Series Switches, supporting four
Copper and two single-mode (Long-Reach) fiber network segments.
The 6KP6-RJSSC, when installed in a Magnum 6K8-Series Switch has copper
supporting the 100m distance and Fiber supporting single-mode fiber cable lengths of as
much as 40+ Km (see Power Budget, Section 4.5)
Each port has an Activity (ACT) LED indicating packets being received, a
Link (LK) LED indicating proper connectivity with the remote device when lit, and a
FDX/HDX LED indicating full-duplex mode when lit (or half-duplex when off). The
10/100 LED indicates the speed for the copper port, which is 100Mbps when the LED is
ON and 10 Mb, when the LED is OFF.
5.2.4a 6KP6-RJ10ST 4 @ 10/100 Mb copper port and 2@10Mbps multi­mode FL-ST-type, “twist-lock” connector
The Magnum 6KP6-RJ10ST is also a Combo module equipped with 4 dual speed copper
ports and 2 multi-mode 10 Mb fiber ST-type connectors. It provides a combination of
copper and Fiber functions in one module to the 6K8-Series Switches, supporting four
Copper and two 10Mb of ST fiber network segments.
The 6KP6-RJ10ST, when installed in a Magnum 6K8-Series Switch has copper
supporting the 100m distance and Fiber supporting multi-mode fiber cable allow to
connect the legacy network of 10Mb requirement in the network. Each port has an
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
50
www GarrettCom com
..
Activity (ACT) LED indicating packets being received, a Link (LK) LED indicating
proper connectivity with the remote device when lit, and a FDX/HDX LED indicating
full-duplex mode when lit (or half-duplex when off). The 10/100 LED indicates the
speed for the copper port, which is 10Mbps when the LED is ON and 10 Mb when the
LED is OFF.
5.2.5 6KP8-MTRJ, 8 @100Mb multi-mode FX , MTRJ Small-Form-factor
Magnum 6KP8-MTRJ is a multi-mode fiber optic 8-port module equipped with
a small-form-factor MTRJ-type
connector. It looks almost like
an RJ-45 port, but it is black in
color. The MT-RJ’s small size
and ease of connection make it
a good choice for 100Mbps
“fiber-to-the-desktop” Ethernet
connectivity. When installed in
a Magnum 6K8-Series Switch,
it supports fiber optic cable
distances up the IEEE-standard
100Mbps distance limits, i.e.,
typically 2km at full-duplex and 412m at half-duplex.
The functionality of this 100BASE-FX multi-mode 8 Port module is essentially
the same as the ST and SC-types. It has the same LEDs per port indicating port activity
(ACT), Link (LK), and FDX or HDX operation.
5.2.5a 6KP6-MT10ST, 4 @100Mb multi-mode FX , MTRJ Small-Form-
Factor and 2@ 10Mb Multi-mode ST-Fiber port
The 6KP6-RJ10ST is a combo module with two different kinds of fiber flavor
with two different speeds. The top four ports of MTRJ Small form factor fiber support at
100Mb full-duplex, whereas the bottom two ports multi-mode ST-Fiber support 10Mb
half-duplex. This combo module provides more flexibility to the user to connect their
legacy 10Mbfiber as well as 100Mb to the Magnum 6K8-Series Switch.
When installed in a Magnum 6K8-Series Switch, the 100Mb MTRJ connector
supports fiber optic cable distances up to the IEEE-standard 100Mbps distance limits,
i.e., typically 2km at full-duplex and 412m at half-duplex. The10Mb Multi-mode ST-
“small-form-factor”
FULL/HALF
1
ACTIVITY
LINK
2
2
3
3
1 3 5 7
2 4 6 8
LK LK LK LK
ACT F/H
ACT F/H
ACT F/H
1
ACT
F/H
LK LK LK LK
ACT
F/H ACT
F/H
ACT
F/H
ACT
F/H
6KP8-MTRJ, 8 Port@ 100Mbps Multi-Mode Fiber port
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
51
www GarrettCom com
..
Fiber connector supports the standard fiber optic distance limit of 2Km at Full and Half-
duplex both.
The functionality of this 100BASE-FX multi-mode 4 port module is
essentially the same as the ST and SC-types. It has the same LEDs per port
indicating port activity (ACT), Link (LK), and FDX or HDX operation
5.2.6 6KP8-45MT, 4@ 10/100Mbps RJ-45 and 4@100Mb multi-mode FX , MTRJ Small-Form-Factor
The Magnum 6KP8-45MT
Module is a combo module with
copper and fiber (Small Form Factor)
MTRJ type ports. The small size of
MTRJ connectors provides an
advantage of placing more ports on
one module. The 6KP8-45MT is
equipped with 4 10/100 RJ-45 ports
and 4 MTRJ fiber ports.
When installed in a Magnum 6K8-
Series Switch, it supports the
standard distances as mentioned on 5.2.3. and the LEDs also act similarly.
5.2.7 6KP8-MLC, 8 ports @ 100Mbps multi-mode LC connector Small-
Form Factor
Magnum 6KP8-MLC is a eight-
port multi-mode fiber LC connector
“small-form-factor” used primarily in
100Mbps fiber-to-the-desktop links.
When installed in a Magnum 6K8-Series
Switch, it supports fiber optic cable
distances up to the IEEE-standard
100Mbps distance limits, i.e., typically
2km at full-duplex and 412m at half-
duplex.
The compact size of the LC Connector reduces the size of wiring panels in
wiring closets while providing the advantage of “future-proof” fiber optic technology.
The cable end is a “plug-in” connector with both fiber strands terminated in
one housing that cannot be improperly inserted. Each port has an Activity (ACT) LED
4
3
2 4 6 8
LK LK LK LK
ACT F/H
ACT F/H
2
ACT
F/H
ACT
F/H
6KP8-45MT 4 Port@ 10/100Mbps & 4 port @ 100Mbps
Multi-Mode Fiber port
1 3 5 7
10/100
LK
1
F/H
ACT
4
FULL/HALF
1
ACTIVITY
LINK
2
3
10/100
FULL/HAL
1
ACTIVIT
LINK
2
3
3
2
1
8-Port@ 100Mbps multi-mode LC fiber port
2 4 6
LK LK LK
ACT F/
ACT F/
ACT
F/H
ACT
F/H
2 4 6
LK LK LK
ACT F/
ACT F/
ACT
F/H ACT
F/H
1 3 5
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
52
www GarrettCom com
..
indicating packets being received, a Link (LK) LED indicating proper connectivity with
the remote device when lit, and a FDX/HDX LED indicating full-duplex mode when lit
(or half-duplex when off).
5.2.8 6KP8-45LC, Combo 4@ 100Mbps multi-mode -LC small-form
factor
and 4@ 10/100 Mbps RJ-45 Connector
The Magnum 6KP8-
45LC Module is a combo
module with a combination of
copper and Fiber (Small Form
Factor) LC type ports. The
small size of LC connectors
allows an advantage of having
more ports on one module.
The 6KP8-45LC is equipped
with 4 10/100 RJ-45 ports and
4 LC ( Small form factor)
multi-mode fiber ports.
When installed in a Magnum 6K8-Series Switch, it supports the standard distances as per
mentioned on 5.2.8. and the LEDs also acts similarly as mentioned above.
5.2.9 6KP8-RJ45 (Twisted Pair), 10/100Mb 8-Port
The 6KP8-RJ45 module supports Ethernet twisted pair segments of any
standard length. It is
equipped with an eight-port
RJ-45 connector, and offers
10/100 full / half-duplex
auto-negotiating capability
on each port. The RJ-45
connector is shielded to
minimize emissions and will
allow both unshielded
twisted pair (UTP) and
shielded twisted pair (STP)
cable connections. The 6KP8-RJ45 module is equipped with a Media Dependent Auto-
Crossover (MDI-X) switch, which controls all ports for cascaded connection. This
6KP8-RJ45,
8 Port@ 10/100Mb Copper ports
4
4
FULL/HALF
1
ACTIVITY
LINK
2
3
10/100
2
1 3 5 7
10/100
LK
1
3
F/H
ACT
10/100
LK
2 4 6 8
F/ H
ACT
4
3
2 4 6
LK LK LK
AC F/H
AC F/H
2
ACT
F/H
ACT
F/H
4 Port@ 10/100Mbps & 4 port @ 100Mbps Multi
-Mod LC Fiber port
1 3 5
10/10
LK
1
F/
ACT
4
FULL/HALF
1
ACTIVITY
LINK
2
3
10/10
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
53
www GarrettCom com
..
4
3
2 4 6
LK
2
ACT
F/H
ACT
F/H
6KP8V-6KP8-45-2MT
6 Port
@
10/10Mbps & 2 port @100Mb
Multi-Mode Fiber port
1 3 5
10/10
L
1
F/H
AC
4
FULL/HALF
1
ACTIVITY
LINK
2
3
10/100
10/100
F/H
feature eliminates the need for a special twisted pair crossover cable when connecting to
a hub or another switch.
Each port has an Activity (ACT) LED indicating packets being received, a
Link (LK) LED that indicates proper connectivity with the remote device when lit, a
FDX/HDX LED to indicate full-duplex mode when lit (or half-duplex when off), and a
“10/100” LED indicating 100Mb when lit (or 10 Mbps when off).
Important Note: The 10/100 RJ-45 ports are supported with Auto-negotiation and
Auto-crossover (MDIX), which allow the RJ-45 ports to automatically Link with any RJ­45 device and eliminate the use of cross-over cable.
5.2.10 6KP8-45-2MT, 6@ 10/100Mbps RJ-45 and 2@100Mb multi-mode FX , MTRJ Small-Form-Factor
The Magnum 6KP8-
45-2MT eight port Module is a
combo module with copper and
fiber (Small Form Factor)
MTRJ type ports. The small
sizes of MTRJ connectors give
an advantage of placing more
fiber ports on one module. The
6KP8-45-2MT is equipped with
six 10/100 RJ-45 ports and two
100Mb MTRJ fiber ports. When installed in a Magnum 6K8-Series Switch, it supports
the standard distances as mentioned on 5.2.3. and the LEDs also act similarly.
5.2.10a 6KP8-45-2LC, 6@ 10/100Mbps RJ-45 and 2@100Mb single-mode FX , LC Small-Form-Factor
The Magnum 6KP8-45SLC eight port Module is a combo module with copper
and fiber (Small Form Factor) LC type fiber ports.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
54
www GarrettCom com
..
The small sizes of LC connectors
provide an advantage of placing
more ports on one module. The
6KP8-45-2SLC is equipped with 6
10/100 RJ-45 ports and 2 Single-
mode fiber ports.
When installed in a Magnum 6K8-
Series Switch, it supports the
standard distances as mentioned on
5.2.4. and the LEDs also act
similarly.
5.2.11 GBIC-SXSC Gigabit fiber(1000Mb), multi-mode SC Connector
The Magnum GBIC-SXSC is a multi-mode Gigabit fiber connector
equipped with SC type connectors and can be easily snapped in and out. The Gigabit
fiber ports are most popular as server-to-switch and switch-to-switch applications. It
supports cable distances up to the IEEE 802.3z standard 1000Mbps distance limits, i.e.,
550m at full duplex.
1@ 1000Mb Fiber SC + 4@10/ 100Mb
The GBIC transceiver has been offered in the modular slot with multiple options as per
the user requirement. The two Giga port has been offered as GBPM-2OTX (fiber or RJ-
45), whereas the single Gigabit module comes in two different flavor of G+2 (100Mb
fiber ports) or G+4(10/100 RJ-45 ports) as shown in the above figure.
The GBIC transceiver is fastened using snap-in clips. Insert the transceiver
(take care to insert it the right way up, arrows on top) until it clicks in space. While
removing the transceiver, press the clips on either side of the transceiver at the same time
and pull the transceiver out.
Each port has an Activity (ACT) LED indicating packets being received and a
Link (LK) LED indicating proper connectivity with the remote device when lit.
1 3 5 7
10/100
L
F/
ACT
TX RXL
K
ACT F/
4
3
2 4 6
LK
2
ACT
F/H
ACT
F/H
6KP8V-
6 Port@ 10/100Mbps & 2 port @ 100Mbps
Single-Mode Fiber port (LC)
1 3 5
10/10
L
1
F/H
AC
4
FULL/HALF
1
ACTIVITY
LINK
2
3
10/100
10/100
F/H
6KP8-45-2SLC
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
55
www GarrettCom com
..
5.2.11a GBIC-LXSC Gigabit fiber (1000Mb), multi-mode SC Connector
The Magnum GBIC-LXSC is a single-mode Gigabit fiber connector equipped
with SC type connectors and can be easily snapped in and out. The Gigabit fiber ports are
most popular as server-to-switch and switch-to-switch applications. It supports cable
distances up to the IEEE 802.3z standard 1000Mbps distance limits, i.e., 10,25, 40 or
70Km at full duplex, and depend upon the Gigabit modules used.
1@ 1000Mb Fiber SC + 2@ 100Mb SC
The two Giga port has been offered as GBPM-2OTX (fiber or RJ-45), whereas the single
Gigabit module comes in flavor of G+4(10/100 RJ-45 ports) or G+2 (100Mb fiber ports)
as shown below in the above figure.
Each port has an Activity (ACT) LED indicating packets being received and a link (LK)
LED indicating proper connectivity with the remote device when lit.
TX RXL
ACT F/
TX LK RX
ACT F/
TX RXL
K
ACT F/
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
56
www GarrettCom com
..
6.0 TROUBLESHOOTING
All Magnum Ethernet products are designed to provide reliability and
consistently high performance in all network environments. The installation of a
Magnum 6K8-Series Switch is a straightforward procedure (see INSTALLATION,
Section 2.6); the operation is also straightforward and is discussed in Section 4.
Should problems develop during installation or operation, this section is
intended to help locate, identify and correct these types of problems. Please follow the
suggestions listed below prior to contacting your supplier. However, if you are unsure of
the procedures described in this section or if the Magnum 6K8-Series Switch is not
performing as expected, do not attempt to repair the unit; instead contact your supplier
for assistance or contact GarrettCom Customer Support.
6.1 Before Calling for Assistance
1. If difficulty is encountered when installing or operating the unit, refer back to
the Installation Section of the applicable chapter of this manual. Also check
to make sure that the various components of the network are interoperable.
2. Check the cables and connectors to ensure that they have been properly
connected and the cables/wires have not been crimped or in some way
impaired during installation. (About 90% of network downtime can be
attributed to wiring and connector problems.)
3. Make sure that an AC power cord is properly attached to each Magnum 6K8-
Series Switch unit. Be certain that each AC power cord is plugged into a
functioning electrical outlet. Use the PWR LEDs to verify each unit is
receiving power.
4. If the problem is isolated to a network device other than the Magnum 6K8-
Series Switch product, it is recommended that the problem device be replaced
with a known good device. Verify whether or not the problem is corrected. If
not, go to Step 5 below. If the problem is corrected, the Magnum 6K8-Series
Switch and its associated cables are functioning properly.
5. If the problem continues after completing Step 4 above, contact your supplier
of the Magnum 6K8-Series Switch unit or if unknown, contact GarrettCom,
Inc. by fax, phone or email (support@garrettcom.com) for assistance.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
57
www GarrettCom com
..
6.2 When Calling for Assistance
Please be prepared to provide the following information.
1. A complete description of the problem, including the following points:
a. The nature and duration of the problem;
b. Situations when the problem occurs;
c. The components involved in the problem;
d. Any particular application that, when used, appears to create the problem;
2. An accurate list of GarrettCom product model(s) involved, with serial
number(s). Include the date(s) that you purchased the products from your
supplier.
3. It is useful to include other network equipment models and related hardware,
including personal computers, workstations, terminals and printers; plus, the
various network media types being used.
4. A record of changes that have been made to your network configuration prior
to occurrence of the problem. Any changes to system administration
procedures should all be noted in this record.
6.3 Return Material Authorization (RMA) Procedure
All returns for repair must be accompanied by a Return Material Authorization (RMA) number. To obtain an RMA number, please use this URL -
https://rma.garrettcom.com/rma/rma_request_noaccount.php
to fill out the form.
Please have the following information readily available:
Name and phone number of your contact person. Name of your company / institution Your shipping address Product name Serial Number (or Invoice Number) Packing List Number (or Sales Order Number) Date of installation Failure symptoms, including a full description of the problem.
GarrettCom will carefully test and evaluate all returned products, will repair products that are under warranty at no charge, and will return the warranty-repaired units to the sender with shipping charges prepaid (see Warranty Information, Appendix A, for complete details). However, if the problem or condition causing the return cannot be duplicated by GarrettCom, the unit will be returned as:
No Problem Found.
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
58
www GarrettCom com
..
GarrettCom reserves the right to charge for the testing of non-defective units under warranty. Testing and repair of product that is not under warranty will
result in a customer (user) charge.
6.4 Shipping and Packaging Information
Should you need to ship the unit back to GarrettCom, please follow these instructions:
1. Package the unit carefully. It is recommended that you use the original container if available. Units should be wrapped in a "bubble-wrap" plastic sheet or bag for shipping protection. ( You may retain all connectors and this Installation Guide.)
CAUTION
:
Do not pack the unit in Styrofoam "popcorn" type packing
material. This material may cause electro-static shock damage to the unit.
2. Clearly mark the Return Material Authorization (RMA) number on the outside of the shipping container.
3. GarrettCom is not responsible for your return shipping charges.
4. Ship the package to:
GarrettCom, Inc. 47823 Westinghouse Dr. Fremont, CA 94539-7437
Attn.: Customer Service
APPENDIX A: WARRANTY INFORMATION
GarrettCom, Inc. warrants its products to be free from defects in materials and workmanship for a period of three (3) years from the date of shipment by GarrettCom.
During this warranty period, GarrettCom will repair or, at its option, replace components in the products that prove to be defective at no charge other than shipping and handling, provided that the product is returned pre-paid to GarrettCom.
This warranty will not be effective if, in the opinion of GarrettCom, the product has been damaged by misuse, misapplication, or as a result of service or modification other than by GarrettCom.
GarrettCom reserves the right to make a charge for handling and inspecting any product returned for warranty repair which turns out not to be faulty.
Please complete the warranty card as this acts as a product registration, and mail it to GarrettCom within two weeks of your purchase.
APPENDIX B : Internal DC Power Supply Options
B1.0 SPECIFICATIONS FOR MAGNUM 6K8-SERIES SWITCHES, DC POWER
Magnum 6K8-Series models, for –48V and 24V DC & 125VDC Power input Each Magnum Model 6K8-Series Managed Switch (DC option) requires a DC
power source, for 24VDC, -48VDC and 125VDC option power input. The wide range of
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
59
www GarrettCom com
..
power input qualifies this product for use in 24VDC, -48VDC as well as 125VDC environments. The 24VDC, -48VDC or 125VDC power input provides an Ethernet networking product utilizing a special type of power supply with a proven high­reliability record to fulfill the DC requirement.
DC Power Terminals: “+”, “
-”,
internally floating
GND: Terminal for “earth” or ground wire connection to the 6K8-Series chassis Input Voltage: 18 to 36 VDC (24VDC)
Input current: 0.6Amps max.(for all RJ-45 ports) Input current: 1.2Amps max.(for all Fiber ports)
Input Voltage: -36 to -70 VDC (-48VDC) Input current: 0.4Amps max.(for all RJ-45 ports) Input current: 0.7Amps max.(for all Fiber ports)
Input Voltage: 88 to 300 VDC (125VDC) Input current: 0.1Amps max.(for all RJ-45 ports)
Input current: 0.125Amps max.(for all Fiber ports) Power Consumption: 25 watts max., for fully loaded (fiber ports) (24V, -48V, 125V)DC 8 watts typical for all (RJ-45 Ports)
B2.0 -48VDC, 24VDC and 125VDC POWER, THEORY OF OPERATION
The -48VDC, 24VDC and
125VDC power options are designed
using diodes inside on each DC power
input line behind the two external power
connection terminals, so that the power
from an external source can only flow
into the switch. This allows the Switch to operate only whenever DC power is correctly
applied to the two inputs. It protects the Switch from incorrect DC input connections. An
incorrect polarity connection, for example, will neither affect the Switch, its internal
power supply, nor will it blow the fuse in the internal power supply.
The manual power “On-Off” Switch (optional) is used for powering the unit on
and off when it is placed into or taken out of service.
B3.0 APPLICATIONS FOR DC POWERED ETHERNET SWITCHES
Magnum 6K8-Series Switches are
easily installed in a variety of applications
where -48VDC, 24, or 125VDC or 5VDC
power is used as the primary power source.
The DC power configuration capability
A+
A-
GND
GND
CHASSIS
FUSE
+
-
SUPPLY
HUB
POWER SWITCH
DC terminal block
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
60
www GarrettCom com
..
provides
an Ethernet networking solution utilizing a special
power supply in switches with a proven track record.
Figure C5.0: -48VDC, wiring connections to the External Terminal Block on a Magnum 6K8 -48VDC
The –48VDC solution is particularly useful inthe telecommunication industry, where it is
common for facilities to operate on -48VDC power. Such companies include regular and
wireless telephone service providers, Internet Service Providers (ISPs) and other
communication companies. In addition, many high availability equipment services,
such as broadcasters, publishers, newspaper operations, brokerage firms and other
facilities often use a battery backup system to maintain operations in the event of a power
failure. It is also frequently used for computer system backup, management and
operations monitoring equipment.
The 24V and 125VDC options are particularly useful in the Industrial environment,
where it is common for facilities to operate on 24VDC or 125VDC power. The 125VDC
options are mainly used in power utilities, such as electrical substations, electrical
generating plants, etc. The 24VDC applications are mainly in the Industrial environment,
such as factory floor, HVAC equipment, military equipment, etc. The 5VDC options are
mainly used for military or Industrial factory floor applications.
B4.0 6K8-SERIES, -48V, 24, 125 OR 5VDC INSTALLATION
This section describes the proper connection of the -48VDC leads (or
24VDC/125VDC/5VDC leads) to the DC power terminal block on the Magnum 6K8-
Series Switch. The DC terminal block on the Magnum 6K8-Series Managed Switch is
located on the left front of the unit and is equipped with three (3) screw-down lead posts.
The power terminals are identified as positive (+) and negative (-), and they are floating
inside the unit so that either may be grounded by the user if desired. The chassis is
“earth” or ground (GND).
The connection procedure is straightforward. Simply insert the DC leads to the
Switch’s power terminals, positive (+) and negative (-) screws. The use of Ground
(GND) is optional; it connects to the Switch chassis. Ensure that each lead is securely
tightened.
NOTE: Always use a voltmeter
to measure the voltage of the incoming power supply and figure out the +ve potential lead or -ve potential lead. The more +ve potential lead will connect to the post labeled “+ve” and the rest to the “-ve”. The GND can be hooked up at the last.
When power is applied, the green PWR LED will illuminate.
Note: The GND should be hooked up first. The 6K8-Series unit has a floating ground,
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
61
www GarrettCom com
..
so the user may elect to Ground either + or = terminal to suit the customer’s use. Before connecting hot lines to the Terminal Block of –48VDC, 24VDC or 125VDC, always use a digital voltmeter to measure the output voltage of the power supply and determine the lead which is more “+ve potential”. The more “+ve” voltage lead from 48V or –48V supply must be connected to the post labeled “+”.
B4.1 UL Requirements for DC-powered units
1. Minimum 18AWG cable for connection to a Centralized DC power source.
2. Minimum 14AWG cable for connection to a earthing wiring.
3. Use only with Listed 10 A circuit breaker provided in building installation.
4. “Complies with FDA radiation performance standards, 21 CFR subchapter J.” or equivalent.
5. Fastening torque of the lugs on the terminal block: 9 inch-pound max.
6. Centralized DC Power Source cable securement, use at least four cable ties to secure the cable to the rac,k at least 4 inches apart, with the first one located within 6 inches of the terminal block.
B5.0 OPERATION Operation of Magnum 6K8-Series Switches with the optional -48VDC,
24VDC and 125VDC power supply is identical to that of the standard AC-powered
models.
Similarly to order the optional 24VDC or 125VDC industrial specific power
supply factory installed, add a suffix of “24VDC” or “125VDC” after the product ‘s
standard model #. Example: Magnum 6K8-Series- 24VDC, Magnum 6K8-Series-
125VDC.
B7.0 TROUBLESHOOTING Please refer to Section 6.0 for troubleshooting
APPENDIX C: Internal DC Dual-Source Power Option
C1.0 SPECIFICATIONS - FOR MAGNUM 6K8-SERIES FIBER SWITCH
Power Supply (Internal, -48VDC Dual-Source, model # Dual-Src-48V)
DC Power Connector: First Source: “A+”, “A
-“
, 2nd Source “B-“, “B+” GND: Terminal for “earth” or ground wire connection to the hub chassis Input: Two separate sources, each at 36 - 70 VDC
Power Supply (Internal, 24VDC Dual-Source, model # Dual-Src-24V)
DC Power Connector: First Source: “A+”, “A
-“
, 2nd Source “B-“, “B+” GND: Terminal for “earth” or ground wire connection to the hub chassis Input: Two separate sources, each at 18 - 36 VDC
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
62
www GarrettCom com
..
Power Supply (Internal, 125VDC Dual-Source, model # Dual-Src-125V)
DC Power Connector: First Source: “A+”, “A
-“
, 2nd Source “B-“, “B+” GND: Terminal for “earth” or ground wire connection to the hub chassis Input: Two separate sources, each at 88 - 300 VDC
With the exception of the dual DC input power connections and the power
supply, all specifications and configuration options for the Magnum 6K8-Series -48VDC,
24VDC and 125VDC models with this Dual-Source option are identical to those listed in
the Magnum 6K8-Series Fiber Switches Installation and User Guide, including Appendix
B “Internal DC Power Supply Option”
C2.0 MAGNUM 6K8-SERIES, with -48VDC, 24VDC and 125VDC Dual-Source option (OPTIONAL)
The 6K8-Series-Switch models with the internal -48VDC, 24VDC and
125VDC Dual-Source power supply are designed for installations where a battery plant
is the power source, and where two separate power sources are utilized in order to
increase operational uptime and to simplify maintenance.
The functionality of the Magnum 6K8-Series Switch -48VDC, 24VDC and
125VDC Dual-Source Option units is identical to the standard AC-powered models.
Refer to the main sections of this Installation and User Guide for a detailed description
of the Magnum 6K8-Series Switches.
C3.0 DUAL-SOURCE OPTION, THEORY OF OPERATION
The Dual-Source DC power
option is designed using diodes inside
of the chassis on each DC power input
line. A diode is placed in each of the
four input lines (behind the four
external power connection terminals)
so that power from an external source
can only flow into the unit. This allows the unit to operate whenever DC power is
correctly applied to either or both of the two inputs
C4.0 FEATURES AND BENEFITS OF THE DUAL-SOURCE DESIGN
a) The Switch unit can receive power from either input, “A” or “B”. The hub will normally draw
its power from the DC source with the highest voltage at a given time.
b) The Switch unit will not allow power to flow from a higher voltage input to a lower voltage
input, i.e. the two DC power sources are not mixed together by the hub.
c) When one correct DC input is present, the Switch will receive power if the other DC input is
absent, or even if it is connected with reverse polarity or shorted or grounded.
d) Reverse polarity connections, if they should accidentally occur on either input, will not damage
the Switch or power supply internally (nor will it blow the fuse in the internal power supply)
GND
FUSE
+
-
SUPPLY
A+
A-
B-
B+
GND
CHASSIS
HUB
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
63
www GarrettCom com
..
because of the blocking action of the diodes. This is true even if one input connection is reversed while the Switch is operating from the other source.
e)
The Switch will not receive power (and will not work) when both inputs are simultaneously
absent or are both incorrectly connected.
C5.0 INSTALLATION
This section describes the proper connection of the -48VDC, 24VDC and
125VDC dual source leads to the -48VDC, 24VDC &
125VDC power terminal block on the Magnum 6Ks Switch
as shown in Fig.
The -48VDC terminal block on the Magnum 6K8-Series
Switch, as shown in Fig C5.0 is
located on the left front of the unit
and is equipped with five (5)
screw-down lead posts.
The primary terminals are identified as positive (A+),
negative (A-), and the secondary power terminals as negative (B-), positive(B+). The
chassis “earth” or ground (GND) is a threaded post with a #6 nut. The Dual Source
terminal block for the 24VDC and 125VDC are similar. Figure C5.0: -48VDC-Dual- Src, wiring connections to the External Terminal Block on a Magnum 6K8 -48VDC
Note: The GND should be hooked up first. The 6K8-Series unit has a floating ground, so the user may elect to Ground either + or = terminal to suit the customer’s use. Before connecting hot lines to the Terminal Block of –48VDC, 24VDC or 125VDC, always use a digital voltmeter to measure the output voltage of the power supply and determine the lead which is more “+ve potential”. The more “+ve” voltage lead from 48V or –48V supply must be connected to the post labeled “+”.
The connection procedure is straightforward. Simply connect the DC leads to
the Switch’s power terminals, positive (+) and negative (-) screws. The use of Ground
(GND) is optional; it connects to the Switch chassis. Ensure that each lead is securely
tightened.
The 24VDC & 125VDC terminal block on Magnum 6K8-Series’s is similar to
that described in the –48VDC information above.
C5.1 UL Requirements The following must be adhered to in order to conform to UL requirements:
1. Minimum 18 AWG cable for connection to a Centralized DC power source.
2. Minimum 14 AWG cable for connection to earthing wiring.
3. Use only with Listed 10 A circuit breaker provided in building installation.
4. “Complies with FDA radiation performance standards, 21 CFR subchapter J.”
or equivalent.
5. Fastening torque of the lugs on the terminal block: 9 inch pound max.
DC Terminal Block
(
Dual-Source
)
Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
64
www GarrettCom com
..
6. Centralized DC Power Source cable securement, use at least four cable ties to
secure the cable to the rack at least 4 inches apart with the first one located within 6 inches of the terminal block.
C6.0 ORDERING INFORMATION (Optional) To order the optional Dual-Source
-48VDC power supply factory installed,
order “Dual-Src48V” as a separate line item following the product model.
Example: Magnum 6K8 -48VDC Dual-Src-48V for the regular DS model Similarly, order the “Dual –source 24VDC” or “Dual-source 125VDC” as a
separate line item following the product model.
Example: Magnum 6K8 -24VDC
C7.0 OPERATION Operation of the Dual-Source Magnum 6Ks-48VDC, 24VDC and 125VDC
Switch models are identical to that of the standard models.
Loading...