GarrettCom Magnum 10KG Installation And User Manual

www GarrettCom com
..
Magnum 10KG
Managed Switch
with Timing
Hardware
Installation and User Guide
Magnum 10KG Managed Switch Installation and User Guid e 07/12
i
www GarrettCom com
..
Magnum10KG
Managed Switch
Hardware
Installation and User Guide
Part #: 84-00192Z (Rev. A)
Trademarks GarrettCom is a registered trademark and Magnum, Dymec, DynaStar, Personal Switch, Link-Loss-Learn, S-Ring, Convenient Switch and Converter Switch
are trademarks of GarrettCom, Inc. Ethernet is a trademark of Xerox Corporation NEBS is a trademark of Telcordia Technologies UL is a registered trademark of Underwriters Laboratories
Important: The Magnum 10KG Managed Switch contains no user-serviceable parts. Attempted service by unauthorized personnel may render all warranties null and void. If problems are experienced with Magnum 10KG Switch products, consult Section 6, Troubleshooting.
Copyright © 2012 GarrettCom, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission from GarrettCom, Inc. Printed in the United States of America
GarrettCom, Inc. reserves the right to change specifications, performance characteristics and/or model offerings without notice.
Warranty:
Refer to current Belden Americas Terms & Conditions for warranty information.
Contacting GarrettCom, Inc Please use the mailing address, phone and fax numbers and email address listed below:
GarrettCom, Inc.
47823 Westinghouse Dr.
Fremont, CA 94539-7437
Phone (510) 438-9071
Fax (510) 438-9072
Website: http://www.GarrettCom.com
Email: support@garrettcom.com
Magnum 10KG Managed Switch Installation and User Guid e 07/12
ii
www GarrettCom com
..
Complies with FDA radiation performance standards, 21CFR Subchapter J.
Federal Communications Commission
Radio Frequency Interference Statement
This equipment generates uses and can radiate frequency energy and if not installed and used properly in strict accordance with the manufacturer's instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user, at their own expense, will be required to take whatever measures may be required to correct the interference.
Canadian Emissions Statement This Class A digital apparatus meets all requirements of the Canadian
Interference-Causing Equipment Regulations.
Cet appareil respecte toutes les exigences du Réglement sur le matériel du Canada. Cet appareil est Classe A.
Electrical Safety requirements:
1. This product is to be installed Only in Restricted Access Areas (Dedicated Equipment Rooms, Electrical Closets, or the like).
2. All products shall be installed with a readily accessible disconnect device in the building installation supply circuit to the product.
3. This product shall be provided with a maximum 10A DC Listed fuse or circuit breaker in the supply circuit when connected to a 48V centralized source.
4. The external power supply for DC units shall be Listed, Direct Plug In power unit, marked Class 2, or listed ITE Power Supply, marked LPS, which has suitably rated output voltage (i.e. 24VDC or 48VDC) and suitable rated output current.
5. Product does not contain user replaceable fuses. Any internal fuses can ONLY be replaced by GarrettCom personnel through the RMA process.
6. The chassis main earthing screw shall be connected to the supply protective earthing conductor.
This equipment has the ordering option of being supplied to the purchaser without a Fiber Optic Class 1 Laser transceiver included. In this case, it is the responsibility of the purchasing party to apply the proper labeling required to the product, in accordance with US 21CFR Subchapter J Part 1040, if a transceiver is installed by the purchaser. (See label example below)
Magnum 10KG Managed Switch Installation and User Guid e 07/12
iii
www GarrettCom com
..
Table of Contents Page
1.0 SPECIFICATIONS ................................................................................... 1
1.1 Technical Specifications ......................................................................... 1
1.2 Ordering Information .............................................................................. 4
2.0 INTRODUCTION ................................................................................... 11
2.1 Inspecting the Package and Product ...................................................... 11
2.2 Product Description - Magnum 10KG Managed Switch ....................... 12
2.3 Managed Network Software for Magnum 10KG .................................. 13
2.4 Features and Benefits ............................................................................ 14
3.0 INSTALLATION ................................................................................... 16
3.1 Locating Magnum 10KG Switches ....................................................... 16
3.2 Connecting Ethernet Media ................................................................... 17
3.2.1 Connecting Twisted Pair (CAT3, CAT5, UTP or STP) ................... 17
3.2.2 Connecting Twisted Pair (CAT5e or better, UTP or STP) ............... 18
3.2.3 Connecting Singlemode Fiber Optic ................................................ 18
3.2.4 SFP (Small Form-factor Pluggable) Transceivers ............................ 19
3.2.5 Connecting Fiber Optic Cable to SFP Transceivers ......................... 19
3.3 Table-Top or Shelf Mounting................................................................ 20
3.3.1 Rack-mounting options .................................................................... 20
3.3.2 Rack-mounting, Reverse mount option ............................................ 20
3.4 Powering the Magnum 10KG Managed Switch .................................... 23
3.4.1 Power Input connection .................................................................... 23
3.5 Alarm Contacts for monitoring internal power and Software Traps ..... 24
3.6 Connecting the Console Terminal to Magnum 10KG ........................... 26
3.6.1 RJ45 Console port (Serial port) pin assignments ............................. 26
4.0 OPERATION........................................................................................... 27
4.1 Switching Functionality ........................................................................ 27
4.2 Auto-Cross (MDIX) and Auto-negotiation, for RJ-45 ports ................. 28
4.3 Flow-control, IEEE 802.3x standard ..................................................... 29
4.4 Packet Prioritization, 802.1p QOS ........................................................ 30
4.5 Frame Buffering .................................................................................... 30
4.6 Power Budget Calculations for 10KG Modules with Fiber Media ....... 31
5.0 MAGNUM 10KG MANAGED SWITCH PORT MODULES ............ 31
5.1 10KG Modules ...................................................................................... 31
5.1.1 10KG Module LED designations ..................................................... 32
5.1.2 10K4-RJ45, four 10/100Mb RJ45 ports (use in Slots E-H) .............. 33
5.1.3 10K4PX-RJ45, four 10/100Mb PoE+ RJ45 ports (use in Slots E-H)34
5.1.4 10K4-MLC, four Multimode LC (use in Slots E-H) ........................ 35
5.1.5 10K4-SLC, 10K4-SLCL, four Singlemode LC (use in Slots E-H) .. 35
5.1.6 10K4-MTRJ, four Multimode MTRJ (use in Slots E-H) ................. 36
5.1.7 10K2-MSC, 10K2-MST (use in Slots E-H) ..................................... 37
5.1.8 10K2-SSC, 10K2-SSCL, 10K2-SST (use in Slots E-H) .................. 38
5.1.9 10K4-FXSFP, four open 100Mb SFP slots (use in Slots E-H) ......... 38
5.1.1010K2-F10ST, Two 10Mb ST Multimode (use in Slots E-H) ........... 39
Magnum 10KG Managed Switch Installation and User Guid e 07/12
iv
www GarrettCom com
..
5.1.1110-2RJSFP, Two Gigabit RJ-45 or Two SFP (use in Slots A-D) ..... 39
6.0 TROUBLESHOOTING.......................................................................... 40
6.1 Before Calling for Assistance................................................................ 40
6.2 When Calling for Assistance ................................................................. 41
6.3 Return Material Authorization (RMA) Procedure ................................. 41
6.4 Shipping and Packaging Information .................................................... 42
APPENDIX A: DC Power Input ........................................................................ 43
APPENDIX B: Removal / Installation of the Hot-Swap power supply .......... 46
Revisions: Rev. A 07/12: Initial Release
Magnum 10KG Managed Switch Installation and User Guid e 07/12
1
www GarrettCom com
..
1.0 SPECIFICATIONS
1.1 Technical Specifications
Performance
Filtering / Forwarding Rate: Ethernet (10Mb): 14,880 pps Fast Ethernet (100Mb): 148,800 pps Gigabit Ethernet (1000Mb): 1,488,000 pps
Switching Processing Type: Store and Forward with IEEE 802.3x full-
duplex flow control, non-blocking
Data Rate: 10Mbps, 100Mbps and 1000Mbps
Address Table Capacity: 8K node, self-learning with address aging Packet buffer size: 512KB for 10/100Mb, 128KB for Gb Latency: 6μs + packet time max. (TX-TX, TX-FX, FX-FX, TX-G, G-G) System aggregate forward and filter rate: 11.9 Mpps
Network Standards and Compliance, hardware
Ethernet V1.0/V2.0 IEEE 802.3: 10BASE-T, IEEE 802.3u: 100Base-TX, 100BASE-FX IEEE 802.3z: 1000BASE-X Ethernet (Auto-negotiation) IEEE 802.3ab: 1000BASE-X Ethernet IEEE 802.1p: Priority protocol IEEE 802.1d: Spanning Tree protocol IEEE 802.1w: Rapid Spanning Tree protocol IEEE 802.1q: VLAN Tagging IEEE 802.3x: Flow Control IEEE 802.3ad: Link Aggregation (Trunking) IEEE 802.1x: Port-based network access control IEEE 802.3af: Power over Ethernet (PoE) IEEE 802.3at: Power over Ethernet (PoE+) IEEE 1588v2 Timing compliance IPv6 Compliance
Maximum 10 Mbps Ethernet Segment Lengths Unshielded twisted pair - 100 m (328 ft) Shielded twisted pair - 150 m (492 ft) 10BASE-FL multimode fiber optic - 2 km (6562 ft)
Maximum Standard Fast Ethernet Segment Lengths: 10BASE-T (CAT 3, 4, 5 UTP) - 100 m (328 ft)
100BASE-TX (CAT 5 UTP) - 100 m (328 ft) Shielded twisted pair - 150 m (492 ft) 100BASE-FX, half-duplex, multimode - 412 m (1350 ft) 100BASE-FX, full-duplex, multimode - 2.0 km (6562 ft) 100BASE-FX, half-duplex, singlemode - 412 m (1350 ft) 100BASE-FX, full-duplex, singlemode - 20.0 km (66K ft) 100BASE-FX, full-duplex, Long Reach - 40.0 km (122K ft)
Maximum Standard Gigabit Ethernet Segment Lengths: 1000BASE-T (CAT5e or higher is recommended) - 100m (328 ft)
1000BASE-SX, full-duplex, multimode (62.5μm cable) - 220m (722 ft) 1000BASE-SX, full-duplex, multimode (50μm cable) - 550m (1804 ft)
Magnum 10KG Managed Switch Installation and User Guid e 07/12
2
www GarrettCom com
..
1000BASE-LX, full-duplex, multimode (50, 62.5μm cable) - 550m (1804 ft) 1000BASE-LX, full-duplex, singlemode (9μm cable) - 5km (16.4K ft) 1000BASE-ZX, full duplex, singlemode (9μm cable) - >70km (229.6K ft)
Fiber Multimode connector types supported: Fiber Port, LC-type (plug-in): SFF fiber multimode 100BASE-FX
Fiber Port, MTRJ-type (plug-in): SFF fiber multimode 100BASE-FX Fiber Port, SC-type (plug-in), multimode 100BASE-FX Fiber Port, ST-type (twist-lock), multimode 100BASE-FX Fiber Port, 1000BASE-SX, SFP modules
Fi ber Singlemode connector types:
Fiber Port, LC-type, Fiber SFF singlemode, 100BASE-FX Fiber Port, SC-type, singlemode, 100BASE-FX Fiber Port, 1000BASE-LX, SFP modules
LEDs: Per Port (see section 5.1.1 for detailed LED configurations)
Operating Environment
Ambient Temperature:
-40° to 140° F (-40° to 60°C) for UL 60950 and Component Parts rating
-40° to 185° F (-40° to 85°C) for IEC 60068 Type Test short term rating Storage Temperature: -40° to 185°F (-40°to 85°C) Ambient Relative Humidity: 5% to 95% (non-condensing) Altitude: -200 to 13,000 ft. (-60 to 4000m) Conformal Coating (humidity protection) optional: Request quote
Alarm Relay Contacts Form C, One NC hardware controllable, One NC software controllable
10KGP (PoE chassis): One Form C, NC/NO software controllable
Mechanical (Thermal fin version)
Enclosure: High strength steel, 1.5U rack-mounting or stand-alone Dimensions: 2.63 in H x 17.5 in W x 12.0 in D
(6.7 cm H x 44.5 cm W x 30.5 cm D)
Cooling method: Convection, special (patent pending) thermal techniques or Fan cooling
Weight: 14.2 lbs. (6.5 kg)
Mechanical (non-Thermal fin version)
Enclosure: High strength steel, 1U rack-mounting or stand-alone Dimensions: 1.74 in H x 17.5 in W x 12.0 in D
(4.4 cm H x 44.5 cm W x 30.5 cm D)
Cooling method: Convection, special (patent pending) thermal techniques or Fan cooling
Weight: 9.7 lbs. (4.4 kg)
Magnum 10KG Managed Switch Installation and User Guid e 07/12
3
www GarrettCom com
..
DC P ower Supply (Internal, floating ground) DC Power Connector: Terminal block
(L) 24/48VDC Power Input (range 22 to 60VDC) (H) AC/DC Power Input (range 90-250V AC or DC) Standard 3-screw Terminal block: “ -, +, GND ”
for PoE applications: PoE+ 802.3at: (L) 48VDC Power Input (range 52 to 56VDC)
Standard 2-screw Terminal block: “+, -“
Power Consumption:
55 watts Max. (for a fully-loaded model w/ 8Gb ports, 16 100Mb fiber ports)
AC Power Supply (Internal) AC Power Connector: IEC-320/C14 type, male recessed
100-240VAC Power Input, 47 to 63 Hz (auto-ranging)
Power Consumption:
30 watts typical with 32 fully-loaded copper ports
Manage me nt Console Conne c tor
RJ45, see details at Section 3.6
10KG Mounting:
Rack-mounting , standard method. Unit supplied with rack-mounting brackets for mounting in a 19” rack.
Agency Approvals and Standards Compliance: ANSI/UL 60950-1, Issued: 2007/03/27 Ed:2 UL Standard for Safety for
Information Technology Equipment Safety Part 1: General Requirements’ CSA C22.2 No. 60950-1, Issued: 2007/03/01 Ed:2 Standard for Safety for Information Technology Equipment Safety Part 1: General Requirements’ Emissions meet FCC Part 15 Class A IEEE 1613 Class 2 Environmental Standard for Electric Power Substations See also Note for P ower Substations in Section 3.2.1 and 5.1.2 IEC 61850-3 EMC and Operating Conditions Class C for Power Substations
NEMA TS-2 for Traffic Control EN50155 for Railways
Warranty: Refer to current Belden Americas Terms & Conditions for warranty information
Email
info@GarrettCom.com for additional information.
Magnum 10KG Managed Switch Installation and User Guid e 07/12
4
www GarrettCom com
..
1.2 Ordering Information
Hot-Swap Power supply models, w/Thermal Fins MODEL
DESCRIPTION
10KG-HSPHH-TF: Magnum 10KG Managed Switch, front-mount, with two PS
slots for two H Hot-Swap Power Supplies. May be factory-configured with a variety of fiber and copper port modules selected designed specifically for the 10KG-series. Configure up to 24 ports in a mix of Gb and 100Mb. Heavy-duty case with thermal fins for maximum convection cooling efficiency in a rack-mount setting.
10KGR-HSPHH-TF: Same as Model 10KG-HSPHH-TF except chassis is a Reverse Mount unit. (All signal and power cables are in the rear)
10KG-HSPHL-TF: Magnum 10KG Managed Switch, front-mount, with two PS slots for one H and one L Hot-Swap Power Supply. May be factory-configured with a variety of fiber and copper port modules selected designed specifically for the 10KG-series. Configure up to 24 ports in a mix of Gb and 100Mb. Heavy-duty case with thermal fins for maximum convection cooling efficiency in a rack-mount setting.
10KGR-HSPHL-TF: Same as Model 10KG-HSPHL-TF except chassis is a Reverse Mount unit. (All signal and power cables are in the rear)
10KG-HSPLL-TF: Magnum 10KG Managed Switch, front-mount, with two PS slots for two L Hot-Swap Power Supplies. May be factory-configured with a variety of fiber and copper port modules selected designed specifically for the 10KG-series. Configure up to 24 ports in a mix of Gb and 100Mb. Heavy-duty case with thermal fins for maximum convection cooling efficiency in a rack-mount setting.
10KGR-HSPLL-TF: Same as Model 10KG-HSPLL-TF except chassis is a Reverse Mount unit. (All signal and power cables are in the rear)
Hot-Swap Power supply models, wo/Thermal Fins MODEL
DESCRIPTION
10KG-HSPHH: Magnum 10KG Managed Switch, front-mount, with two PS
slots for two H Hot-Swap Power Supplies. May be factory-configured with a variety of fiber and copper port modules selected designed specifically for the 10KG-series. Configure up to 24 ports in a mix of Gb and 100Mb.
10KGR-HSPHH: Same as Model 10KG-HSPHH except chassis is a Reverse Mount unit. (All signal and power cables are in the rear).
10KG-HSPHL: Magnum 10KG Managed Switch, front-mount, with two PS slots for one H and one L Hot-Swap Power Supply. May be factory-configured with a variety of fiber and copper port modules selected designed specifically for the 10KG-series. Configure up to 24 ports in a mix of Gb and 100Mb.
10KGR-HSPHL: Same as Model 10KG-HSPHL except chassis is a Reverse Mount unit. (All signal and power cables are in the rear).
10KG-HSPLL: Magnum 10KG Managed Switch, front-mount, with two PS slots for two L Hot-Swap Power Supplies. May be factory-configured with a variety of fiber and copper port modules selected designed specifically for the 10KG-series. Configure up to 24 ports in a mix of Gb and 100Mb.
10KGR-HSPLL: Same as Model 10KG-HSPLL except chassis is a Reverse Mount unit. (All signal and power cables are in the rear)
Magnum 10KG Managed Switch Installation and User Guid e 07/12
5
www GarrettCom com
..
Fixed Power supply models w/Thermal Fins MODEL DESCRIPTION
10KG-H-TF: Magnum 10KG Managed Switch, front-mount, with integral 90-
250V AC/DC Power Supply. May be factory-configured with a variety of fiber and copper port modules selected designed specifically for the 10KG-series. Configure up to 24 ports in a mix of Gb and 100Mb. Heavy-duty case with thermal fins for maximum convection cooling efficiency in a rack-mount setting.
10KGR-H-TF: Same as Model 10KG-H-TF except chassis is a Reverse Mount unit. (All signal and power cables are in the rear)
10KG-HH-TF: Magnum 10KG Managed Switch, front-mount, with two integral 90­ 250V AC/DC Power Supply. May be factory-configured with a variety of fiber and copper port modules selected designed specifically for the 10KG-series. Configure up to 24 ports in a mix of Gb and 100Mb. Heavy-duty case with thermal fins for maximum convection cooling efficiency in a rack-mount setting.
10KGR-HH-TF: Same as Model 10KG-HH-TF except chassis is a Reverse Mount unit. (All signal and power cables are in the rear)
10KG-L-TF: Same as Model 10KG-H-TF except the integral power supply is L 24/48VDC.
10KGR-L-TF:
Same as Model 10KG-L-TF except chassis is a Reverse Mount unit.
(All signal and power cables are in the rear) 10KG-LL-TF: Same as Model 10KG-HH-TF except the integral power supplies are
L 24/48VDC. 10KGR-LL-TF: Same as Model 10KG-LL-TF except chassis is a Reverse Mount unit.
(All signal and power cables are in the rear) 10KG-HL-TF: Same as Model 10KG-HH-TF except the integral power supplies are
one H 90-250V AC/DC and one L 24/48VDC. 10KGR-HL-TF: Same as Model 10KG-HL-TF except chassis is a Reverse Mount unit.
(All signal and power cables are in the rear) 10KG-AC-TF: Same as Model 10KG-H-TF except the power supply is an auto-sensing
worldwide AC power type (100-240V AC) using a UL-registered recessed-male IEC 320 plug.
10KGR-AC-TF: Same as Model 10KG-AC-TF except chassis is a Reverse Mount unit. (All signal and power cables are in the rear)
Magnum 10KG Managed Switch Installation and User Guid e 07/12
6
www GarrettCom com
..
Fixed Power supply models, wo/Thermal Fins MODEL
DESCRIPTION
10KG-H: Magnum 10KG Managed Switch, front-mount, with integral 90-250V
AC/DC Power Supply. May be factory-configured with a variety of fiber and copper port modules selected designed specifically for the 10KG-series. Configure up to 24 ports in a mix of Gb and 100Mb.
10KGR-H: Same as Model 10KG-H except chassis is a Reverse Mount unit. (All signal and power cables are in the rear)
10KG-HH: Magnum 10KG Managed Switch, front-mount, with two integral 90-250V AC/DC Power Supply. May be factory-configured with a variety of fiber and copper port modules selected designed specifically for the 10KG-series. Configure up to 24 ports in a mix of Gb and 100Mb.
10KGR-HH: Same as Model 10KG-HH except chassis is a Reverse Mount unit. (All signal and power cables are in the rear)
10KG-L: Same as Model 10KG-H except the integral power supply is L 24/48VDC. 10KGR-L:
Same as Model 10KG-L except chassis is a Reverse Mount unit.
(All signal and power cables are in the rear) 10KG-LL: Same as Model 10KG-HH except the integral power supplies are
L 24/48VDC. 10KGR-LL: Same as Model 10KG-LL except chassis is a Reverse Mount unit.
(All signal and power cables are in the rear) 10KG-HL: Same as Model 10KG-HH except the integral power supplies are
one H 90-250V AC/DC and one L 24/48VDC. 10KGR-HL: Same as Model 10KG-HL except chassis is a Reverse Mount unit.
(All signal and power cables are in the rear) 10KG-AC: Same as Model 10KG-H except the power supply is an auto-sensing
worldwide AC power type (100-240V AC) using a UL-registered recessed-male IEC 320 plug.
10KGR-AC: Same as Model 10KG-AC except chassis is a Reverse Mount unit. (All signal and power cables are in the rear)
Magnum 10KG Managed Switch Installation and User Guid e 07/12
7
www GarrettCom com
..
PoE models MODEL
DESCRIPTION
10KGP-HSPLL-TF: Magnum 10KG Managed Switch, front-mount, with two PS
slots for two L Hot-Swap Power Supplies. Supports PoE – choose PoE module(s) separately. May be factory-configured with a variety of fiber and copper port modules selected designed specifically for the 10KG-series. Configure up to 24 ports in a mix of Gb and 100Mb. Heavy-duty case with thermal fins for maximum convection cooling efficiency in a rack-mount setting.
10KGPR-HSPLL-TF: Same as Mode l 10KGP-HSPL L-TF except chassis is a Reverse Mount unit. (All signal and power cables are in the rear)
10KGP-HSPLL: Magnum 10KG Managed Switch, front-mount, with two PS slots for two L Hot-Swap Power Supplies. Supports PoE – choose PoE module(s) separately. May be factory-configured with a variety of fiber and copper port modules selected designed specifically for the 10KG-series. Configure up to 24 ports in a mix of Gb and 100Mb.
10KGPR-HSPLL: Same as Model 10KGP-HSPLL except chassis is a Reverse Mount unit. (All signal and power cables are in the rear)
10KGP-L-TF: Magnum 10KG Managed Switch, front-mount, with integral 24/48VDC Power Supply. Supports PoE – choose PoE module(s) separately. May be factory­ configured with a variety of fiber and copper port modules selected designed specifically for the 10KG-series. Configure up to 24 ports in a mix of Gb and 100Mb. Heavy-duty case with thermal fins for maximum convection cooling efficiency in a rack-mount setting.
10KGPR-L-TF: Same as Model 10KGP-L-TF except chassis is a Reverse Mount unit. (All signal and power cables are in the rear)
10KGP-LL-TF: Magnum 10KG Managed Switch, front-mount, with two integral 24/48VDC Power Supply. Supports PoE – choose PoE module(s) separately. May be specifically for the 10KG-series. Configure up to 24 ports in a mix of Gb and 100Mb. Heavy-duty case with thermal fins for maximum convection cooling efficiency in a rack-mount setting.
10KGPR-LL-TF: Same as Model 10KGP-LL-TF except chassis is a Reverse Mount unit. (All signal and power cables are in the rear)
10KGP-L: Magnum 10KG Managed Switch, front-mount, with integral 24/48VDC Power Supply. Supports PoE – choose PoE module(s) separately. May be factory­ configured with a variety of fiber and copper port modules selected designed specifically for the 10KG-series. Configure up to 24 ports in a mix of Gb and 100Mb.
10KGPR-L: Same as Model 10KGP-L except chassis is a Reverse Mount unit. (All signal and power cables are in the rear)
Please use this URL: for the complete Product bulletin for the Magnum 10KG.
http://www.garrettcom.com/techsupport/hardware/datasheets/10kg_dscs.pdf
Magnum 10KG Managed Switch Installation and User Guid e 07/12
8
www GarrettCom com
..
“HSP” Hot-Swap power supply options: (If “HSP” base unit is selected, choose up to two power supply modules. For “-HF” or “-LF” models below, Also choose the KT-RFAN option in the Options & Extras below)
HSPM-H: AC or DC power (90-250V) HSPM-L: 24/48V DC power (22-60V) HSPM-HF: AC or DC power (90-250V) w/Internal cooling fan HSPM-LF: 24/48V DC power (22-60V) w/Internal cooling fan 10K-PSBLNK: Blank cover for one hot-swap power supply slot
Following module can be configured in Slots A thru D only Magnum 10KG (Slots A thru D) Port Modules: 10-2RJSFP Module with two 10/100/1000 RJ-45 ports and SFP ports
Includes 1588 Timing capabilities
Gigabit SFP transceiver options for Slots A thru D: SFP-GTP Gb SFP transceiver, Copper 1000Base-T, 100m
SFP-SX Gb SFP transceiver, 1000Mb-SX, 850nm wavelength, 550m SFP-ESX Gb SFP transceiver, 1000Mb, 1310nm wavelength, 2km SFP-LX10 Gb SFP transceiver, 1000Mb-LX, 1310nm wavelength, 10km SFP-LX25 Gb SFP transceiver, 1000Mb-LX, 1310nm wavelength, 25km SFP-ZX40 Gb SFP transceiver, 1000Mb-ZX, 1550nm wavelength, 40km SFP-ZX70 Gb SFP transceiver, 1000Mb-ZX, 1550nm wavelength, 70km
100Mb SFP transceiver options for module 10-2RJSFP: SFP100P-FXMM2 100FX fiber SFP transceiver, multimode, 2km SFP100P-FXSM20 100FX fiber SFP transceiver, singlemode, 20km SFP100P-FXSM40 100FX fiber SFP transceiver, singlemode, 40km SFP100P-RJ45 10/100Mb, RJ45 SFP transceiver
Following modules can be configured in Slots E thru H only Magnum 10KG (Slots E thru H) Port Modules: 10K4-RJ45 Module w/four 10/100 RJ-45 ports 10K4T-RJ45 Module w/four 10/100 RJ-45 ports with 1588 timing 10K4PX-RJ45 Module w/four 10/100 RJ-45 PoE PLUS (802.3at) ports
Supports PoE (802.3af) or PoE Plus (802.3at) (PoE chassis and L power supply is required)
10K4-MLC Module w/four 100Mb multimode fiber LC ports 10K4T-MLC Module w/four 100Mb multimode fiber LC ports with 1588 timing 10K4-SLC Module w/four 100Mb singlemode fiber LC ports (20km) 10K4T-SLC Module w/four 100Mb singlemode fiber LC ports (20km)
with 1588 timing
Magnum 10KG Managed Switch Installation and User Guid e 07/12
9
www GarrettCom com
..
10K4-SLCL Module w/four 100Mb “long-haul” singlemode fiber LC ports (40km) 10K4T-SLCL Module w/four 100Mb “long haul” singlemode fiber LC ports (40km)
with 1588 timing
10K4-MTRJ Module w/four 100Mb multimode fiber MTRJ ports 10K4T-MTRJ Module w/four 100Mb multimode fiber MTRJ ports with 1588 timing 10K2-MST Module w/two multimode ST fiber ports 10K2T-MST Module w/two multimode ST fiber ports with 1588 timing 10K2-SST Module w/two singlemode ST fiber ports 10K2T-SST Module w/two singlemode ST fiber ports with 1588 timing 10K2-F10ST Module w/two multimode 10Mb ST fiber ports 10K2-MSC Module w/two multimode SC fiber ports 10K2T-MSC Module w/two multimode SC fiber ports with 1588 timing 10K2-SSC Module w/two singlemode SC fiber ports 10K2T-SSC Module w/two singlemode SC fiber ports with 1588 timing 10K2-SSCL Module w/two “long-haul” singlemode SC fiber ports 10K4-FXSFP Module w/four open 100Mb SFP ports
100Mb SFP transceiver options for module 10K4-FXSFP: SFP100P-FXMM2 100FX fiber SFP transceiver, multimode, 2km SFP100P-FXSM20 100FX fiber SFP transceiver, singlemode, 20km SFP100P-FXSM40 100FX fiber SFP transceiver, singlemode, 40km SFP100P-RJ45 10/100Mb, RJ45 SFP transceiver
NOTE: 1588 timing modules must be configured in vertical slot pairs only.
(For example, if slot E, on the top, has a timing module, then slot F, below it, must also have a timing module or be unpopulated.)
10KG Slot locations:
Magnum 10KG Managed Switch Installation and User Guid e 07/12
10
www GarrettCom com
..
Options & Extras: KT-RFAN: Removable Fan for extra fiber ports and cooling;
Optional for up to 16 fiber ports. Required for 18 to 36 fiber ports. CONSOLE-CBLQD: Console attachment cable. Serial null modem (aka X-modem)
cable with RJ45 connector for the 10KG on one end and a DB-9 connector on other end.
CONSOLE-CBLQU: Same as above, but with USB connector MNS-6K-SECURE: Optional, licensed software per switch for extra security S-RING-Key: S-Ring Redundancy Manager licensed software for redundant ring
management. One S-Ring key is for licensed use one 10KG-managed self healing ring. CONFORM05-RMOD: Conformal coating, heavy duty silicone at 5 mil thickness, for
interior PCBs, PS and modules (for moisture protection) CONFORM08-RMOD: Conformal coating, heavy duty silicone at 8 mil thickness, for
interior PCBs, PS and modules (for corrosion in paper, mining, and oil & gas industries)
DUAL-SRC-L: Provides two separate 24/48VDC power inputs (the unit will operate from either or both) to accommodate redundant 24/48V installations for increased availability and ease of DC power source maintenance. Includes internal diode protection to prevent feedback. Order this option as a line item, for factory configuration. The unit will have its model number changed to append "-DSRC". ONLY available on "L", "LL" or "HSPLL" chassis options. Note - not needed for "LL" PoE chassis which are inherently dual-source.
Hot-Swap power supply locations:
Magnum 10KG Managed Switch Installation and User Guid e 07/12
11
www GarrettCom com
..
2.0 INTRODUCTION
2.1 Inspecting the Package and Product
Examine the shipping container for obvious damage prior to installing this product; notify the carrier of any damage that you believe occurred during shipment or delivery. Inspect the contents of this package for any signs of damage and ensure that the items listed below are included.
This package should contain:
1 Magnum 10KG Managed Switch, base unit (configured with user-selected port module options installed, and factory-
loaded MNS-6K or MNS-6K-SECURE software installed) 1 Set of two metal 19” rack-mounting brackets, with screws to mount to
10KG case
Remove the items from the shipping container. Be sure to keep the shipping container should you need to re-ship the unit at a later date.
In the event there are items missing or damaged, contact the party from whom you purchased the product. If the unit needs to be returned, please use the original shipping container if possible. Refer to Section 6, Troubleshooting, for specific return procedures.
Loading...
+ 35 hidden pages