GarrettCom magnum Installation And User Manual

www G a rre ttC o m co m
..
www G a rre ttC o m com
..
Corporate Headquarters
GarrettCom, Inc.
47823 Westinghouse Drive Fremont, CA 94539
Fax (510) 438-9072 Website: http://www.GarrettCom.com
email support@garrettcom.com
Magnum
Personal Hubs
Installation and User Guide
Magnum Personal Hubs I nst allation and User Guide (09/01)
i
www G a rre ttC o m com
..
Magnum
Personal Hub

Installation and User Guide
Part #: 84-00023 (Rev B)
Trademarks
Ethernet is a trademark of Xerox Corpor at ion NEBS is a trademark of Telcordia Technologies UL is a registered trademark of Underwriters Laboratories
GarrettCom, Magnum
and
Personal Switch
are trademarks and
Personal Hub
is
a registered trademark of GarrettCom, Inc.
Important:
Magnum Personal Hubs contain no user serviceable parts. Attempted service by unauthorized personnel shall render any and all warranties null and void. If problems are experienced with a Magnum Personal Hub, consult Section 5, troubleshooting, of this User Guide.
Copyright  2001 GarrettCom, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission from GarrettCom, Inc.
Printed in the United States of America.
Magnum Personal Hubs I nst allation and User Guide (09/01)
ii
www G a rre ttC o m com
..
Contacting GarrettCom, Inc
Please use the mailing address, phone and fax numbers and email address listed below:
GarrettCom, Inc.
213 Hammond Ave.
Fremont, CA 94539
Phone (510) 438-9071
Fax (510) 438-9072
Website: http://www.GarrettCom.com
email
support@garrettcom.com
Federal Communications Commission
Radio Frequency Interference Statement
This equipment generates, uses and can radiate frequency energy and if not installed and used properly, that is in strict accordance with the manufacturer's instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user at his own expense will be required to take whatever measures may be required to correct the interference.
Magnum Personal Hubs I nst allation and User Guide (09/01)
iii
www G a rre ttC o m com
..
TABLE OF CONTENTS Page
1.0 SPECIFICATIONS............................................................1
1.1. Technical Specifications.....................................................1
1.2 ORDERING INFORMATION............................................3
2.0 INTRODUCTION.............................................................4
2.1 Inspecting the Package and Product.................................... 4
2.2 Product Description............................................................5
2.3 Features and Benefits...........................................................7
2.4 Applications.........................................................................9
3.0 I
NSTALLATION
..................................................................10
3.1 Table-Top or Shelf Mounting...........................................10
3.2 Wall (or Vertical Surface) Mounting.................................11
3.3 Twisted Pair Connections..................................................12
3.4 AUI Connection (Models H40A and H80A only).............12
3.5 Switchable Up-Link Feature..............................................13
3.6 Cascading Personal Hubs with the Up-Link Port ..............14
4.0 OPERATION...................................................................15
4.1 Functional Operation, Use of LED Indicators...................15
5.0 TROUBLESHOOTING ..................................................16
5.1 Before Calling for Assistance............................................16
5.2 When Calling for Assistance.............................................17
5.3 Return Material Authorization (RMA) Procedure.............17
5.4 Shipping and Packaging Information................................. 18
APPENDIX A: W
ARRANTY INFORMATION
..........................18
Revisions
Rev C 04/01:
Change the company name to GarrettCom, Inc. (Formerly it was Garrett Communications). There are no changes to the content of the material at this time.
Rev A 04/97
: This revision is the initial release of the Magnum Personal Hub user manual.
Magnum Personal Hubs I nst allation and User Guide (09/01)
www G a rre ttC o m com
..
The Magnum Line
ETHERNET CONNECTIVITY PRODUCTS
"DESIGNED AND MANUFACTURED IN THE USA"
OVERVIEW
GarrettCom, Inc.offers the premium-quality Magnum line of Ethernet LAN connectivity products with industry-standard functionality and built-in fiber configurability. Magnum products are designed for use in demanding Carrier Class, Industrial Grade and OEM applications where reliability is a primary consideration.
4K-Series Switches,
100 & 10Mbps, copper ports with optional
fiber port, with auto-negotiating full switching performance
Quad-Series Fiber Switches,
100 & 10Mbps, fiber and copper ports, mixed-speed and mixed-media types, full switching performance
“Outdoor” Ethernet Switch,
for temperature uncontrolled locations 6 10/100 and 2 100Mb fiber ports, can be connected in strings
Mixed-Media Fiber Hub, 16-port Stackable,
10/100 auto-sensing
Dual Speed 8-port and 16-port Stackables,
10/100 auto-sensing
Stackable Hubs, SNMP Optional
10Mb series and 100Mb series, both w/ optional port modules
Personal Switches
, 10/100Mb
8 port dual speed, Auto-negotiable with fiber option
Personal Hubs
, 100Mb or 10/100Mb
8-port, with two switched ports (1 fiber built in)
Personal Hubs, 10Mb series
8-port + AUI, stackable to 5 high, + optional BNC of fiber port 8 or 9-port and 4 or 5-Port Personal Hubs, w/ man. up-link sw
.
Media Converters, 10Mb and 100Mb series
All media combinations, incl. fiber ST, SC, mm., single mode
The “X-line” of configurable MiXed Media products:
Stackable Concentrators, SNMP optional,
13-Ports
Mini-Concentrators,
7 Ports,
Repeaters
, 2-Ports
Repeater Port Modules (RPMs),
6 types for Ethernet media
Bridge Port Modules (BPMs)
, 4 types, for segment isolation
Fan-Outs, 10Mb series
2, 4 and 8 Port Models
Transceivers, 10Mb and 100Mb series
10Mb Mini-Transceivers
and Coax Models, All Types -
Apr, 01
Magnum Personal Hubs I nst allation and User Guide (09/01)
1
www G a rre ttC o m co m
..
1.0 SPECIFICATIONS
1.1. Technical Specifications Performance:
Data Rate: 10 Mbps Partitioning: Enforced after 32 consecutive collisions. Reconnect: Occurs after 512 bits error-free transmission.
Maximum Ethernet Segment Lengths:
10BASE-T (Unshielded twisted pair) - 100 m (328 ft) 10BASE-T (Shielded twisted pair)- 150m (492 ft) AUI Drop Cable - 50 m (164 ft)
Network Standards:
Ethernet V1.0/2.0 IEEE 802.3: 10BASE-T, 10BASE5.
(Magnum Personal Hubs are physical layer standard Ethernet products, and
operate in networks independently of all software.)
Operating Environment:
Ambient Temperature: 32ºF to 122ºF (0ºC to 50ºC) Storage Temperature: -20ºC to 60ºC Ambient Relative Humidity: 10% - 95% (non-condensing)
Power Supply (External):
Power Input: 95 - 125 vac at 60 Hz for "-d" Models,
200 - 250 vac at 50 Hz for "-i" Models, which have
IEC power cable connector in the external power unit. Power Consumption: H40A, H50: 6 watts max.; H80A, H90: 10 watts max.
Connectors:
H40A: 4 front shielded RJ-45 (1 with up-link switch), 1 rear AUI, female with slide lock. H50: 4 front shielded, RJ-45, 1 rear shielded RJ-45 with up-link switch. H80A: 8 front shielded RJ-45 (1 with up-link switch), 1 rear AUI, female with slide lock. H90: 8 front shielded RJ-45, 1 rear shielded RJ-45 with up-link switch.
(Shielded 10BASE-T connectors accept either unshielded or shielded
wiring lugs for standard twisted pair media wiring.)
The regular RJ-45 ports support the standard for hubs-to-users twisted pair wiring: pin 1= receive+, 2 = receive-, 3 = transmit+, 6 = transmit-, other pins not used. The RJ-45 port with the MDI-X switch is normally the same, but when switched it supports the standard for up-links using twisted pair wiring, i.e., the transmit and the receive pairs are exchanged: pin 1 = transmit+, 2 = transmit-, 3 = receive+, 6 = receive- , other pins not used.
Magnum Personal Hubs I nst allation and User Guide (09/01)
2
www G a rre ttC o m co m
..
Switches:
Up-Link: MDI-X (Media Dependent Interface-Crossover)
manual slide switch, converts RJ-45 port from a regular (=) user segment port to a crossover (X) up-link port for on-off connection to a backbone or another cascaded hub.
Packaging:
Enclosure: Rugged, high strength steel enclosure.
Suitable for vertical or horizontal mounting.
Recessed LEDs to avoid damage.
Dimensions:
H40A: 4.4in x 2.9in x 0.75in (11.0cm x 7.4cm x 1.9cm)
H50: 4.8in x 3.3in x 0.75in (12.2cm x 8.4cm x 1.9cm )
H80A: 4.4in x 5.0in x 0.75in (11.2cm x 12.7cm x 1.9cm )
H90: 4.4in x 5.0in x 0.75in (11.2cm x 12.7cm x 1.9cm )
Weight:
H40A and H50:13oz (370gr); H80A and H90:1.0lbs (450gr);
Power Supply: 1.0lbs (455gr)
Cooling method:
Convection
Agency Approvals:
115v 60 Hz Power Supply is UL Listed, CSA certified.
230v 50 Hz Power Supply is same, also GS approved.
Emissions: Meets FCC Part 15 Class A and B, VDE Class B
Warranty:
Three years (see also Appendix A) Made in USA
Magnum Personal Hubs I nst allation and User Guide (09/01)
3
www G a rre ttC o m co m
..
1.2 Ordering Information
Magnum Personal Hubs
MODEL DESCRIPTION Magnum H40A-d
Personal Hub with four standard RJ- 45 ports,
one with up-link switch, plus one AUI port, external 115 vac
60 Hz power supply.
Magnum H40A-i
Same as H40A-d, but with external 230 vac
50 Hz power supply.
MagnumH50-d
Personal Hub with four standard RJ- 45 ports,
plus one switched RJ-45 up- link port, external 115 vac 60 Hz
power supply.
Magnum H50-i
Same as H50-d except with external 230 vac
50 Hz power supply.
Magnum H80A-d
Personal Hub with eight standard RJ- 45 ports,
one with up-link switch, plus one AUI port, external 115 vac
60 Hz power supply.
Magnum H80A-i
Same as H80A-d, but with external 230 vac
50 Hz power supply.
Magnum H90-d
Personal Hub with eight standard RJ- 45 ports,
plus one switched RJ-45 up-link port, external 115 vac 60 Hz
power supply.
Magnum H90-i
Same as H90-d except with external 230 vac
50 Hz power supply.
GarrettCom, Inc. reserves the right to change specifications, performance characteristics and/or model offerings without notice.