Copyright 2002 GarrettCom, Inc. All rights reserved. No part
of this publication may be reproduced without prior written permission from
GarrettCom, Inc.
Printed in the United States of America.
www GarrettCom com
..
Magnum 8000X Mixed-Media Fiber Hubs Installation and User Guide (05/02)
Contacting GarrettCom, Inc
Please use the mailing address, phone and fax numbers and email address listed
below:
GarrettCom, Inc.
47823 WestinghouseDrive
Fremont, CA 94539
Phone (510) 438-9071
Fax (510) 438-9072
Website: http://www.GarrettCom.com
email support@garrettcom.com
Federal Communications Commission
Radio Frequency Interference Statement
This equipment generates, uses and can radiate frequency energy and if not
installed and used properly, that is in strict accordance with the manufacturer's
instructions, may cause interference to radio communication. It has been tested and
found to comply with the limits for a Class A computing device in accordance with the
specifications in Subpart J of Part 15 of FCC rules, which are designed to provide
reasonable protection against such interference when operated in a commercial
environment. Operation of this equipment in a residential area is likely to cause
interference, in which case the user at his own expense will be required to take
whatever measures may be required to correct the interference.
www GarrettCom com
..
Magnum DS80 Dual-Speed Personal Hub Installation and User Guide (05/ 02)
The Magnum Line
ETHERNET CONNECTIVITY PRODUCTS
"DESIGNED AND MANUFACTURED IN THE USA"
OVERVIEW
GarrettCom, Inc.offers the premium-quality Magnum line of Ethernet LAN
connectivity products with industry-standard functionality and built-in fiber
configurability. Magnum products are designed for use in demanding Carrier Class,
Industrial Grade and OEM applications where reliability is a primary consideration.
6K25 Managed Fiber Switches, Gigabit, 100 and 10 Mbps, fiber and copper ports,
mix-and match. Features SFF fiber for up to 25 fiber ports in a 1U unit.
4K-Series Switches, 100 and 10 Mbps, copper ports with optional fiber port, with
6.1 Before Calling for Assistance....................................................................... 48
6.2 When Calling for Assistance........................................................................ 49
6.3 Return Material Authorization (RMA) Procedure........................................ 49
6.4 Shipping and Packaging Information ......................................................... 50
APPENDIX A: WARRANTY INFORMATION ………........................................... 50
APPENDIX B: OPTIONAL 48VDC POWER SUPPLY * ............................................……51
APPENDIX C : INTERNAL DC DUAL-SOURCE POWER OPTION ............................……53
www GarrettCom com
..
Magnum 8000X Mixed-Media Fiber Hubs Installation and User Guide (05/ 02)
Revisions
Rev D 05/02 : Updated the Rack Mounting and Appendix B & C with 24VDC &
125VDC Power Supply option
Rev C 05/01 : Change the company name to GarrettCom, Inc. (Formerly it was Garrett
Communications). There are no changes to the content of the material at this time
Rev B 01/01 : Added or changed 100Mbps collision domain diameter, cable
distances and PDV; Port Module (PM) Installation; Installing PM Cards in the
Magnum 8000X; Preparation for Installing and Removing SPMs; Installing
SPM module in Magnum 8000X; Removing SPM module; Power Budget
Calculations for Fiber Media;
Source DC power; Optional Dual Power Supply, AC Power; Optional Dual Power
Supply, 48VDC Power.
Rev A 03/99 : This revision is the initial release of the Magnum 8000X Mixed-Media
Fiber Hub user manual.
Optional 48VDC power supply; Optional 48V Dual-
www GarrettCom com
..
Magnum 8000X Mixed-Media Fiber Hubs Installation and User Guide (05/ 02)
1.0 Technical Specifications
Performance (hub supports both 10 and 100Mb domains, ports individually selected)When a port is operating at 100Mbps
Data Rate: 100Mbps
PDV (Path Delay Value): 80BT, exceeds Class II
When a port is operating at 10 Mbps :
Data Rate: 10 Mbps
Partitioning: Enforced after 63 consecutive collisions
Auto-reconnect: Occurs after one packet of error-free reception
RJ-45 ports are auto-sensing for speed: IEEE 802.3u
Packet-Processing Between Domains (internal 10/100 switch or bridge)
Filtering and Forwarding Rate from 100Mbps ports : 148,800 pps max
Filtering and Forwarding Rate from 10 Mbps ports : 14,880 pps max.
Processing type : Store and Forward
Auto-learning : 8K address table, shared for both traffic domains
Packet buffers : 2MB,dynamically allocated & shared on both domains
Latency (not including packet time) : 100 to 10 Mbps : 5µs
10 to 100Mbps : 5µs
CPU Type : State Machine
Maximum Ethernet Segment (or Domain) Lengths
10BASE-T (CAT 3, 4, 5 UTP)- 100 m (328 ft)
100BASE-TX (CAT 5 UTP)- 100 m (328 ft)
Shielded twisted pair- 150 m (492 ft)
10BASE-FL multi-mode fiber optic - 2 km (6,562 ft)
10BASE-FL single-mode fiber optic- 10 km (32,810 ft)
100BASE-FX, half-duplex:(multi-mode) - 412 m (1350 ft)
100BASE-SX, short wavelength hdx (m.m.) - 300 m ( 935 ft)
100BASE-FX, full duplex:(multi-mode) - 2.0 km (6,562 ft)
100BASE-FX, half-duplex:(single-mode) - 412 m (1350 ft)
100BASE-FX, full duplex:(single-mode) - 15.0 km (49,215 ft)
Operating Environment
Ambient Temperature: 32ºF to 122ºF (0ºC to 70ºC)
Storage Temperature: -20ºC to 70ºC
Ambient Relative Humidity: 5% to 95% (non-condensing)
Power Supply, AC (Internal)
AC Power connector : IEC-type, male recessed, rear of chassis
Power Input Voltage : 90 to 260 VAC (auto ranging)
Power Input Frequency : 47-63 Hz
Magnum 8000X Mixed-Media Fiber Hubs Installation and User Guide (05/ 02)
DC Power Supply (Options)
-48VDC Power Input Voltage : 36 to 70 VDC
24VDC Power Input Voltage : 20 to 36VDC
125VDC Power Input Voltage : 120 to 160VDC
Std. Terminal Block : “ -, GND, + ”
Power Consumption: same as for AC models, see above
For Dual Source and Redundant DC for –48VDC, 24VDC Power & 125VDC
supply options (Optional), see Appendices
For optional 23” Telco rack-mount brackets, order Model # RMB-23W
Network Cable Types (Modular on a per-port basis)
Fiber ports at 100Mbps and/or at 10 Mbps:
Multi-mode (62.5/125 typical) and single-mode (9/125 typical)
100Mbps copper (RJ-45): Category 5 UTP/STP
10 Mbps copper: Cat 3, 4, 5 UTP (Note: auto-neg. doesn’t sense cable type)
Stacking Cable - stacking may be up to three units (48 ports) of mixed-media
8000X hubs and/or DS8016-A Dual-Speed hubs.
A stacking cable with 25 pin DB25 male connectors, shielded, 9 inches (23
cm) long, is included with each Magnum 8000X-A add-on unit.
Manual Switches
Up-link Switch: RJ-45U Port Module only (for crossover and cascading)
Auto/100 Switch: RJ-45 and RJ-45U port Module (for auto-negotiation or
fixed 100Mbps speed operation)
Packaging
Enclosure: High strength metal. 1U rack-mounting brackets included.
Suitable for wiring closet shelf, 19” rack or desktop mounting.
Dimensions: 1.75 in H x 17 in W x 9 in D ( 4.4cm x 43.2cm x 22.9cm)
Weight: 4.0 lb. ( 1.8 Kg)
Cooling method: Fan cooled, internal @ 9 cfm
LED Indicators
PWR : Steady On when power applied
BR : Steady On, unit has bridge module inside
COL 10 and 100 : Collision LEDs, one for each speed domain
ACT 10 and 100 : Activity LEDs, one for each speed domain
Agency Approvals
Safety :UL Listed (UL 1950), cUL, CE
Emissions: meets FCC Part 15, Class A
Warranty
Three years, return to factoryMade in USA
www GarrettCom com
..
2
Magnum 8000X Mixed-Media Fiber Hubs Installation and User Guide (05/ 02)
1.1 Specifications - Port Modules, for front ports of the Magnum 8000X
(For Power Budget data, see Section 4.5)
PM Model #IEEE Standard SpeedConnector type-Mode
FPM-MSTFX100Mbps ST “twist-lock” multi-
FPM-MSCFX100Mbps SC “snap-in” multi-
FPM-SSCFX100Mbps SC “snap-in” single-
FPM-MTRJFX100Mbps MT-RJ “plug-in” multi-
FPM-MV45FX100Mbps VF-45 “plug-in” multi-
FPM-SXMSTSX100Mbps ST “twist-lock” multi-
FPM-SXMSCSX100Mbps SC “snap-in” multi-
FPM10-MSTFL10Mbps ST “twist-lock” multiFPM10-MSCFL10MbpsSC “snap-in” multiFPM10-SSTFL10MbpsST “twist-lock” singleFPM10-SSCFL10MbpsSC “snap-in” singleFPM-MFCFL10Mbps FC “screw-on” multi-
PM-RJ45-T, TX 10/100 auto-neg.RJ-45twisted pair
PM-RJ45U-T, TX 10/100 auto-neg. RJ-45 with up-link sw. TP
PM-BLNKBlank cover for an unused port slot
Two LED indicators per fiber port, in each PM, are “L” for LINK is made, “A” for traffic Activity.
Additional LED for RJ-45 ports are “S” for Speed, where flashing indicates auto-negotiation is
ready (or nothing is connected), steady ON indicates 100Mbps operation and OFF means
operation has been selected by the last auto-negotiation session.
10 Mbps
1.2 Specifications - Switching Port Modules (SPMs) for bonus port
* PDV (path delay value) of an SPM is the same as a user-node i.e. , 50 BT
SPM Type *SPM-TTXSPM-FDSC SPM-FDST SPM-FDSSC
Physical Signaling Type
Connector Type
LINK LED
Receive (RX) LED
Up-link switch
10/100Mb switch
100BASE-TX
& 10BASE-T
RJ-45Fiber-SCFiber-STFiber-SC
yesyesyesyes
yesyesyesyes
yesn.a.n.an.a.
yesn.a.n.a.n.a.
100BASE-FX
mm* f. duplex
100BASE-FX
mm* f. duplex
100BASE-FX
sgl.mode, fdx
(For power budget data, see Section 4.5)
www GarrettCom com
..
3
Magnum 8000X Mixed-Media Fiber Hubs Installation and User Guide (05/ 02)
1.3Ordering Information(see Appendices for DC power supply options)
Magnum 8000X Mixed-Media Fiber Hubs **
Magnum 8000XBase Chassis with 16 Port Module (PM) slots for 10/100
operation per port. Any mix of 100Mbps and 10 Mbps Fiber PMs (see list below) may be
factory or field configured. Includes a switch inside that bridges the two internal traffic
domains. Has a bonus port for an optional switched fiber or copper (SPM) backbone
connection. May be stacked with up to two DS8016-A or -E or 8000X-A add-on units for up
to 3 units (48 front ports for users) in a stack. Internal universal power supply.
Magnum 8000X-AAdd-on Chassis, 16 PM slots, no switch inside, use for stacking
8000X Front Port Modules (PMs):
FPM-MSTModule w/ 100Mbps mm* Fiber FX ST connector
FPM-MSCModule w/100Mbps mm* Fiber FX SC connector
FPM-SSCModule w/100Mbps sgl.m* Fiber FX SC connector
FPM-MTRJModule w/100Mbps mm* Fiber FX MT-RJ connector
FPM-MV45Module w/100Mbps mm* Fiber FX VF-45 connector
FPM-SXMSTModule w/100Mbps mm* Fiber SX ST connector (when available)
FPM-SXMSCModule w/100Mbps mm* Fiber SX SC connector (when available)
FPM10-MSTModule w/10Mbps mm* Fiber FL ST connector
FPM10-MSCModule w/10Mbps mm* Fiber FL SC connector
F PM10-SSTModule w/10Mbps sgl.m* Fiber FL ST connector
FPM10-SSCModule w/10Mbps sgl.m* Fiber FL SC connector
FPM-MFCModule w/10Mbps mm* Fiber FX FC “screw-on” connector
PM-RJ45Module w/ RJ-45 for TP copper, supports 10/100 auto-negotiation
PM-RJ45USame as PM-RJ45 except includes an up-link (crossover) switch
PM-BLNKBlank cover for an unused port.
Switch Port Modules (SPMs) for the Bonus Port:
SPM-FDSCSPM w/ full-duplex multi-mode fiber FX SC connector, includes
a separate switch with packet buffers and filter/forward operation
SPM-FDSTSame as -FDSC, but with ST connector
SPM-FDSSCSPM w/ full-duplex single-mode fiber FX SC connector, includes
a separate switch with packet buffers and filter/forward operation
SPM-TTXSPM with RJ-45, manually selected as 10Mb or 100Mb speed
* mm = multi-mode, sgl.m = single-mode
** To convey configuration information to the factory, order chassis units followed by the
PMs to be configured in it. For example, to order a Model 8000X Hub with a ten FPM10MST ports factory installed, call out “Qty 1 Model 8000X" and then in sequence “Qty 10
Model FPM10-MST” as separate line items. This signifies that the ten FPM-MST modules
are to be factory-configured in the 8000X unit. To order loose modules for field
configuration, order “Qty 10 Model FPM10-MST (do not configure)”, for example.
GarrettCom, Inc. reserves the right to change specifications, performance characteristics
and/or model offerings without notice.
www GarrettCom com
..
4
Magnum 8000X Mixed-Media Fiber Hubs Installation and User Guide (05/ 02)
2.0Introduction - Magnum 8000X Mixed-Media Fiber Hub
2.1Inspecting the Package and Product
Examine the shipping container for obvious damage prior to installing this
product; notify the carrier of any damage which you believe occurred during shipment
or delivery. Inspect the contents of this package for any signs of damage and ensure that
the items listed below are included.
This package should contain:
1 - Magnum 8000X Base Unit (may have PMs factory configured)
1 - AC Power Cord (U.S. and other 115 vac only)
1 - Set of metal "Ears" for optional 19” rack mounting