Magnum 6KQ Managed Field Switch Installation & User Guide 04/07)
Magnum
6KQ
Managed Field Switch
Hardware
Installation and User Guide
Part #: 84-00180Z (Rev. A)
Trademarks
Ethernet is a trademark of Xerox Corporation
NEBS is a trademark of Telcordia Technologies
UL is a registered trademark of Underwriters Laboratories
GarrettCom, Magnum and Personal Switch are trademarks and Personal Hub is a
registered trademark of GarrettCom, Inc.
Important: The Magnum 6KQ Managed Field Switch contains no user
serviceable parts. Attempted service by unauthorized personnel shall render all
warranties null and void. If problems are experienced with Magnum 6KQ
Switch products, consult Section 6, Troubleshooting, of this User Guide.
Copyright 2007 GarrettCom, Inc. All rights reserved. No part
of this publication may be reproduced without prior written permission from
GarrettCom, Inc.
Printed in the United States of America.
www GarrettCom com
..
i
Magnum 6KQ Managed Field Switch Installation & User Guide 04/07)
Contacting GarrettCom, Inc
Please use the mailing address, phone and fax numbers and email address listed below:
GarrettCom, Inc.
47823 Westinghouse Dr.
Fremont, CA 94539-7437
Phone (510) 438-9071
Fax (510) 438-9072
Website: http://www.GarrettCom.com
email support@garrettcom.com
Federal Communications Commission
Radio Frequency Interference Statement
Radio Frequency Interference Statement
This equipment generates, uses and can radiate frequency energy and if not
installed and used properly, that is in strict accordance with the manufacturer's
instructions, may cause interference to radio communication. It has been tested and
found to comply with the limits for a Class A computing device in accordance with the
specifications in Subpart J of Part 15 of FCC rules, which are designed to provide
reasonable protection against such interference when operated in a commercial
environment. Operation of this equipment in a residential area is likely to cause
interference, in which case the user at his own expense will be required to take whatever
measures may be required to correct the interference.
Canadian Emission
This Class A digital apparatus meets all requirements of the Canadian
Interference-Causing Equipment Regulations.
Cet appareil respecte toutes les exigences du Réglement sur le matériel du
Canada. Cet appareil est Classe A..
www GarrettCom com
..
ii
Magnum 6KQ Managed Field Switch Installation & User Guide 04/07)
Table of Contents.............................................................................. Page
APPENDIX B : DC Power Input.................................................................... 46
APPENDIX C: Internal DC Dual-Source Power Input Option.................. 48
Revisions
04/07: Release as Rev A, first printing
................ 41
www GarrettCom com
..
iv
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07)
THE MAGNUM LINE
Industrial networking products
"Designed and Manufactured in the USA"
Overview
GARRETTCOM, INC. OFFERS THE PREMIUM-QUALITY MAGNUM LINE
OF INDUSTRIAL CONECTIVITY PRODUCTS WITH INDUSTRY-STANDARD
FUNCTIONALITY AND BUILT-IN FIBER CONFIGURABILITY. MAGNUM
PRODUCTS ARE DESIGNED FOR USE IN DEMANDING INDUSTRIAL GRADE,
CARRIER CLASS, POWER UTILITY AND OEM APPLICATIONS WHERE
RELIABILITY IS A PRIMARY CONSIDERATION.
6K-SERIES MANAGED FIELD SWITCHES, GIGABIT, 100 AND 10 MBPS, FIBER AND COPPER
PORTS, MIX-AND MATCH. FEATURES SFF FIBER AND DC POWER IN 1U UNITS.
DX-SERIES SERIAL DEVICE ROUTERS, ETHERNET AND SERIAL
4K-SERIES SWITCHES, 100 AND 10 MBPS, COPPER PORTS WITH OPTIONAL FIBER PORT, WITH
AUTO-NEGOTIATING FULL SWITCHING PERFORMANCE.
QUAD-SERIES FIBER SWITCHES, 100 & 10MBPS, FIBER AND COPPER PORTS, MIXED-SPEED AND
MIXED-MEDIA TYPES, FULL SWITCHING PERFORMANCE.
MP62 AND P62F “OUTDOOR” ETHERNET SWITCHES, FOR TEMPERATURE UNCONTROLLED
LOCATIONS, 6 10/100 AND 2 100MB FIBER PORTS, CAN BE CONNECTED IN STRINGS
MIXED-MEDIA FIBER HUB, 16-PORT, 10/100 AUTO-SENSING
DUAL SPEED 8-PORT AND 16-PORT, 10/100 AUTO-SENSING HUBS
PERSONAL SWITCHES, 10/100MB
8 PORT DUAL-SPEED, AUTO-NEGOTIABLE WITH FIBER OPTION
PERSONAL HUBS, 100MB OR 10/100MB 8-PORT, WITH 2 SWITCHED PORTS (1 FIBER BUILT IN)
PERSONAL HUBS, 10MB SERIES 8-PORT + AUI, STACKABLE TO 5 HIGH, + OPTIONAL BNC OF
FIBER PORT 8 OR 9-PORT AND 4 OR 5-PORT PERSONAL HUBS, W/ MAN. UP-LINK SW.
MEDIA CONVERTERS, 10MB AND 100MB SERIES, ALL MEDIA COMBINATIONS, INCL. FIBER ST,
SC, MM., SINGLE MODE
THE “X-LINE” OF CONFIGURABLE MIXED MEDIA PRODUCTS:
STACKABLE CONCENTRATORS, SNMP OPTIONAL, 13-PORTS
MINI-CONCENTRATORS, 7 PORTS, REPEATERS, 2-PORTS
REPEATER PORT MODULES (RPMS), 6 TYPES FOR ETHERNET MEDIA
COAX TRANSCEIVERS, 10MB SERIES
APR, 07
www GarrettCom com
..
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07)
Switching Processing Type: Store and Forward with IEEE 802.3x full-
duplex flow -control, non-blocking
Data Rate: 10Mbps,100Mbps and 1000Mbps
Address Table Capacity: 4K node, self-learning with address aging
Packet buffer size : 240KB for 10/100 and 120KB for 1000Mb
Latency: 5 s + packet time (100 to 100Mbps)
15 s + packet time (10 to 10 Mbps, and 10 to 100Mbps)
Throughput with 12 10/100 and 2Glink max.- 4.76M pps (Transmit)
Back plane- 2.66Gb/s per slot
IEEE 802.3x: Flow Control
IEEE 802.3ad: Link Aggregation (Trunking)
IEEE 802.1x: Port based Network access control
IEEE802.3af: Power over Ethernet
Maximum 10 Mbps Ethernet Segment Lengths
Unshielded twisted pair - 100 m (328 ft)
Shielded twisted pair - 150 m (492 ft)
10BASE-FL multi-mode fiber optic - 2 km (6,562 ft)
10BASE-FL single-mode fiber optic - 10 km (32,810 ft)
Maximum Standard Fast Ethernet Segment Lengths:
10BASE-T (CAT 3, 4, 5 UTP) - 100 m (328 ft)
100BASE-TX (CAT 5 UTP) - 100 m (328 ft)
Shielded twisted pair - 150 m (492 ft)
100BASE-FX, half-duplex, multi-mode - 412 m (1350 ft)
100BASE-FX, full-duplex, multi-mode - 2.0 km (6,562 ft)
100BASE-FX, half-duplex, single-mode - 412 m (1350 ft)
100BASE-FX, full-duplex, single-mode - 20.0 km (66KQ ft)
100BASE-FX, full-duplex, Long Reach - 40.0 km (122K ft)
Maximum Standard Gigabit Ethernet Segment Lengths:1000BASE-T (CAT5e or higher is recommended) - 100 m (328 ft)
1000BASE-SX, full-duplex, multi-mode(62.5m cable) - 220m
www GarrettCom com
..
1
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07)1000BASE-SX, full-duplex, multi-mode(50m cable) - 550m
LEDs: Per Port (one set at the port, one set on swivel top on right side)
LK: Steady ON when media link is operational
ACT: ON with receiver port activity
FDX/HDX: ON = Full-Duplex Mode
OFF = Half-Duplex Mode
100/10: ON = 100Mbps speed
OFF = 10 Mbps
Operating Environment
Ambient Temperature:
-40 to 140 F (-40 to 60C) for UL60950 and Component Parts rating
-60 to 195 F (-50 to 85C) for IEC 60068 Type Test short term rating
Storage Temperature: -60to 210F (-50to 100C) Ambient Relative Humidity: 5% to 95% (non-condensing)
Altitude: -200 to 13,000 ft. (-60 to 4000m)
Conformal Coating (humidity protection) option: Request quote
Alarm Relay Contacts
One NC indicating internal power, one NC software controllable
Packaging
Enclosure: High strength extruded aluminum
Dimensions: 6.85 in. H x 7.5 in. W x 2.0 in. D
17.4 cm H x 19.1 cm W x 5.08 cm D
Cooling method: Convection, fully-enclosed ribbed-surface aluminum case
used as a sink, designed for vertical mounting, no fans
Weight: 3 lbs. (1.3 kg)
Management Console connector
Serial RJ-45, see details at sec. 3.7
DC Power Supply (Internal, floating ground design)
24VDC Power Input nominal (18 to 36VDC range)
-48VDC Power Input nominal (36 to 60 VDC range)
125VDC Power Input nominal (88 to 150VDC range)
Std. Terminal Block : “ -, GND, + ”
Power Consumption:
www GarrettCom com
..
35 watts typical (for a fully loaded fiber model)
2
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07)12 watts typical (for a small 4 port copper-only model)
DC-DUAL POWER SOURCE (OPTIONAL)
For DC internal power supplies at –48VDC, 24VDC and 125VDC, with
the Dual-Source option (
Vertical mounting normal. Suitable for wall or DIN-Rail mounting (6KQ)
Agency Approvals and Standards Compliance:
UL listed (UL60950), cUL, CE, Emissions meet FCC Part 15 Class A
NEBS Level 3 and ETSI Compliant
IEEE 1613 Class 2 Environmental Standard for Electric Power Substations
See also Note for Power Substations in Section 3.2.4, 3.7, and 5.2.9 IEC 61850 EMC and Operating Conditions Class C for Power Substations
NEMA TS-2 and TEES for DC-powered and PoE-powered traffic control
equipment
Class1 Division 2 and ATEX for hazardous locations, pending
Warranty: Three years, per UL 60950 temperature rating
Made in USA
See the Configuration Guide on the GCI web site at
for continuity of operation when either of the DC input
, see Appendices B and C.
for additional information.
www GarrettCom com
..
3
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07)
1.2 Ordering Information
Magnum Managed Field Switch (16 ports max)
MODEL DESCRIPTION
Magnum 6KQ- 24VDC Magnum 6KQ Managed Field Switch, base unit with 24VDC
power supply and four 10/100 copper ports. May be configured with a selection of
10/100/1000 fiber and copper port connector types from a family of 6KQ port modules per
the 6KQ configuration guide, 16 total ports max. Heavy duty and environmentally
hardened, no fans. Dual LEDs for all-around status viewing. Wire speed filtering and
forwarding across all ports, 802.3x flow control, 802.1p priority packet processing, selflearning 4K-node address table, large 240KB packet buffers for 10/100 and 120KB for
1000Mb.
For licensed managed networks software (MNS-6K, RS-Ring and S-Ring) including
GUIs for ease-of-use and industry-leading security features, see separate data sheets.
Magnum 6KQ -48VDC: Same as 6KQ-24VDC except the power input is -48VDC
Magnum 6KQP-48VDC: Same as 6KQ-48VDC except the four 10/100 RJ-45 are PoE
Magnum 6KQ-125VDC: Same as 6KQ-24VDC except the power input is 125VDC
PSAC-24V60 : External Hardened Power Supply for AC to 24VDC, 60 watts, panel or
DIN-RAIL mount.
PSAC-48V150 : External Hardened Power Supply for AC to 48VDC for PoE, 150 watts,
panel or DIN-RAIL mount.
Please use this URL: for the complete Configuration Guide for the Magnum 6KQ.
Configuration Options:
Each Magnum 6KQ base unit may be configured with a choice of 3 modular slots.
Following modules can be configured in Slot B and D (Slot C is 100Mb Fiber only)
Magnum 6KQ Port Modules
6KQ4-RJ45 TP Module, w/four 10/100Mbps copper ports,
P6KQ4-RJ45 PoE 6KQ module, four 10/100 copper ports with PoE on data pairs,
may be configured in slot B only
6KQ4-RJMLC “2+2” module, w/two RJ-45 ports and two 2km mm LC connectors
6KQ4-RJSLC “2+2” module, w/two RJ-45 ports and two 15km Sgl-m LC connectors
6KQ4-RJMT “2+2” module, w/two RJ-45 ports and two 2km mm MTRJ connectors
6KQ2-10ST Two 10Mb mm Fiber 2km FL ST’s
6KP4-MLC SFF mm Fiber module, w/ four 100Mb mm FX LC connectors
6KP4-MT SFF mm Fiber module, w/ four 100Mb mm FX MT-RJ connectors
6KQ2-MST Two 100Mb Fiber module, w/ four 100Mb 2km FX ST connectors
6KQ3-RJMSC “2+1” module, w/two RJ-45 ports and one 2km mm FX SC’s
6KQ2-MSC Two 100Mb Fiber module, w/ four 100Mb 2km FX SC connectors
6KQ2-SSC Two 100Mb Fiber module, SM w/ 100Mb 20km FX SC connectors
6KQ2-SSCL Two 100Mb Fiber module, SM w/ 100Mb 20km FX SC connectors
Fiber-only Slot C configuration choices
www GarrettCom com
..
4
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07)
6KQF-4MT “4 ports” module, w/four 100Mb mm 2km FX MTRJ’s fiber ports
6KQF-4MLC “4 ports” module, w/four 100Mb mm 2km FX LC’s fiber ports
6KQF-4SLC “4 ports” module, w/four 100Mb Sm, 15km FX LC’s fiber ports
6KQF-2MST “2 ports” module, w/two 100Mb mm, 2km FX ST’s fiber ports
6KQF-2MSC “2 ports” module, w/two 100Mb mm, 2km FX SC’s fiber ports
6KQF-2SSC “2 ports” module, w/two 100Mb Sm, 20km FX SC’s fiber ports
6KQF-2SSCL “2 ports” module, w/two 100Mb Sm, 40km FX SC’s fiber ports
6KQF-2MLC “2 ports” module, w/two 100Mb mm, 2km FX LC’s fiber ports
6KQF-2SLC “2 ports” module, w/two 100Mb Sm, 15km FX LC’s fiber ports
6KQF-2MT “2 ports” module, w/two 100Mb mm, 2km FX MTRJ’s fiber ports
6KQF-1MST “1 port” module, w/one 100Mb mm, 2km FX ST’s fiber ports
6KQF-1MSC “1 port” module, w/one 100Mb mm, 2km FX SC’s fiber ports
6KQF-2SSC “1 port” module, w/one 100Mb Sm, 20km FX SC’s fiber ports
6KQF-1SSCL “1 port” module, w/one 100Mb Sm, 40km FX SC’s fiber ports
6KQ-BLNK Blank cover for 1 un-used 6KQ module slot
Gigabit(1000Mb) module choices, slot D only
6KQ-2GSFP “SFP Gig” module, w/two SFP pluggable, open transceiver ports
6KQ-2GCU “Copper Gig” module, w/two10/100/1000 RJ-45 ports
6KQ-2GSFPCU “Copper Gig” module, w/ one SFP pluggable open transceiver port +
ring management. One S-Ring or RS-Ring key is for licensed use one 6K-managed self
healing Ring.
CONSOLE- CBLQD Serial-RJ45 cable, DB9 RS-232 “ null-modem female connector
on one side and RJ-45 on the other side for the RJ-45 Management port (Console port).
CONSOLE- CBLQU USB -RJ45 cable, USB connector on one side and RJ-45 to the
other side for the RJ-45 Management port (Console port).
DIN-RAIL-6KQ Din-Rail holder for a secure vertical mount, with screws for 6KQ
KQ-CABLE-BKT Metal bracket for 6KQ, used for cable strain relief, for vertical
mount
CONFORM05 CRM conformal coating, heavy duty silicone at 5 mil thickness, for
interior PCBs, PS and modules
GarrettCom, Inc. reserves the right to change specifications, performance
characteristics and/or model offerings without notice.
www GarrettCom com
..
5
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07)
2.0 Introduction
2.1 Inspecting the Package and Product
Examine the shipping container for obvious damage prior to installing this
product; notify the carrier of any damage that you believe occurred during shipment or
delivery. Inspect the contents of this package for any signs of damage and ensure that
the items listed below are included.
This package should contain:
1 Magnum 6KQ Managed Field Switch, base unit
(configured with user-selected port module options installed)
1 Set of two metal vertical mounting brackets, with screws to the case
1 Installation and User Guide (this manual)
1 Product Registration Card
Remove the items from the shipping container. Be sure to keep the shipping
container should you need to re-ship the unit at a later date. To validate the product
warranty, please complete and return the enclosed Product Registration Card to
GarrettCom, Inc. as soon as possible.
In the event there are items missing or damaged, contact the party from whom
you purchased the product. If the unit needs to be returned, please use the original
shipping container if possible. Refer to Section 6, Troubleshooting, for specific return
procedures.
www GarrettCom com
..
6
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07)
2.2 Product Description - Magnum 6KQ Field Switch
their class. The fiber-rich 6KQ can be configured with up to 12 100Mb fiber ports and
two Gigabit ports. For 10/100 copper, regular or PoE-equipped 10/100 RJ-45 or
10/100/1000 copper ports may be configured to a maximum or 12 at 10/100 and 2 Gig
ports. Magnum 6KQ comes with the best-of-breed MNS-6K managed networks software
featuring GUI ease of use, Secure Web Management, SNMPv2,v3 management, 802.1p
QoS Prioritization, Tag-based VLANs, IGMP Snooping and IGMP-L2 multicast
management, port security, RADIUS and TACACS+ support, and a choice of
redundancy options including RSTP and GarrettCom’s rapid-ring-recovery S-Ring and
RS-Ring products. See the Managed Networks Software (MNS-6K) datasheet for more
information.
Magnum 6KQs are ideal for building a switched, hardened Ethernet network
infrastructure, connecting edge devices such as PLCs and IEDs with upstream switches
or routers. Designed for use in industrial applications such as factory floors and control
cabinets, industrial video surveillance systems with PoE, power utility substations,
tariffed carrier field facilities, or transportation and oil and gas, the rugged Magnum 6KQ
handles stressful workloads (mixes of bursty data traffic and priority streaming traffic) as
well as harsh environmental conditions.
Magnum 6KQ Managed Field Switches provide maximum configurability in
Advanced thermal design techniques with ribbed –surface Aluminum
cases for maximum heat
dissipation and a sealed
case design enables the unit
to operate in harsh
Industrial grade
environments efficiently.
Heavy duty Ethernet
Switch jobs are readily
accommodated with an extended temperature rating of -40˚C to 60˚C by the UL
Component Parts method, or -50˚C to 85˚C by the IEC 60068 Type-Test method. With
options such as several popular DC power input types (optional AC power) and DIN-Rail
mounting, the hardened Magnum 6KQ is a “multi-purpose” Industrial Ethernet Switch.
www GarrettCom com
..
7
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07)The 6KQ managed switches also provide PoE options via power –
inside PoE modules on one of A, B or C slots and allows the users to select a wide option
of combo PoE modules to support 802.3af pd devices. See details for PoE modules in sec
5.2.10. The Power Sourcing Equipment (PSE) is fully compatible with Powered Devices
(PD)(e.g wireless access points, IP phones) that comply with the IEEE 802.3af PoE
standard. The PoE switch ports have an auto-sensing algorithm, so that they provide
power only to 802.3af, PoE end devices. PoE is managed by a multi-stage handshake to protect equipment from damage and to manage power budgets .The PoE ports
will discontinue supplying power when the PoE powered devices are disconnected. This
feature supports the 802.3af PoE PSE standard for over-current protection, under-current
detection, and fault protection.
High performance features include non-blocking unicast traffic speed on all ports and
802.1p QoS Traffic Prioritization. Magnum 6KQ switches are “plug-and-play” and are
designed for use in connecting edge devices such as PLCs, IEDs and PoE video cameras
with upstream switches and routers where a mix of bursty data traffic and priority
streaming traffic
for video
surveillance and
cell-tower
applications are
present. Magnum 6KQ Field Switches are provided with LAN management software
including SNMP, Tag- and Port-based VLANs, IGMP-L2 and IGMP Snooping, and Port
Security with control via GUI and command line interface (CLI). For high availability
LANs using ring topologies, Spanning Tree Protocol, RSTP, Link-Loss-Learn and SRing are available. Dual-Homing is a software configuration feature. See the Managed
Networks Software (MNS-6K) and S-Ring datasheets for additional details on the
comprehensive set of software programs and options.
Magnum 6KQ Managed Field Switches have heavy-duty aluminum
cases and are readily available with standard Industrial grade 24VDC power. Alternative
internal DC power options are available. DC power input types may be 24V, 48V, 125V,
and dual source DC input is optional on all 6KQ’s. (AC power is available via an
external power supply unit, see Section 3.4 for details).
www GarrettCom com
..
8
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07)
A
A
A
A
Alarm Relay contacts provided on each Magnum 6KQ Switch monitor the hardware and
software through traps, providing a record of any losses of power signals and other userdefined software events. See Section 3.5 for details.
The wide selections of Quad port (queen size) modules are key to the flexibility and
adaptability of Magnum 6KQs. Some of the popular 4 ports modules are described
below. For a list of all the modules and options, see Section 1.2
NOTE: The 6KQ modules can only be configured at the factory.
Fig.2.2.1 :
SFF Fiber Port Modules,
6KQ4-MTRJ (above) and
6KQ4MLC or -SLC (below)
1 2 3 4
CT
F/H
CT
LK LK
F/H
and connector type. Small Form Factor (SFF) Fiber Ports come in multi-mode forms
MT-RJ or LC-type connectors, and single-mode form LC-type connectors.
1 2 3 4
AC
F/H
ACT
F/H
LK LK LK LK
In a four-port SFF (Small Form Factor)
C
F/
fiber port module, all of the fiber ports
C
LK LK
F/
are of the same speed (100Mb), mode,
ACT
F/H
ACT
F/H
The 100Mb fiber four-port modules for the Magnum 6KQ’s normally are set
(factory default) to operate in full-duplex mode for best fiber distance and performance.
Using the 6K-MNS software, the user may select full- or half-duplex mode per-port
through set port command.
The set-up of the software
(See Magnum 6K-MNS
Software Manual) gives the
user flexibility to adapt to any
FDX or HDX type of Fast Ethernet devices).
There are three LED’s per fiber port. The Link (LK) LED indicates “ready for
operation” on that port when lit. The F/H LED indicates operation in full-duplex mode
when ON (half-duplex when OFF). The blinking ACT LED indicates receiving Activity
www GarrettCom com
..
9
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07)
on the port. A fiber cable must be connected into a SFF port a nd t he L i nk (L K) i ndi c a t or
for that port must be ON (indicating there is a powered-up device at the other end of the
cable) in order for a LK LED to provide valid indications of operating conditions on that
port.
2.2.2 Four-Port Copper Module, 6KQ4-RJ45
The 6KQ’s 4-port Copper module, model 6K4-RJ45, provides four 10/100Mb switched
RJ-45 ports. The 10/100Mb
switched ports normally (as a
default setting) are independently
10/10
F/
N-way auto-negotiating and autocrossover (MDIX) for operation at 10 or 100Mb speed in full- or half-duplex mode. (i.e.,
each independently selects a mode and speed to match the device at the other end of the
twisted pair cable).
(See Section 4.3 for auto-negotiation and MDIX details).
On the model 6KQ-RJ45 module, there are four LEDs for each port, two
integrated into the connector, and two below the connector. The LK (Link) LED
indicates “ready for operation” on that port when lit. The blinking ACT (Activity) LED
indicates receiving Activity on that port when lit. The 10/100 LED indicates operation at
100Mb speed when ON and at 10 Mb speed when OFF (when auto-negotiation is not
disabled). The FDX/HDX LED is ON to indicate full-duplex operation and OFF to
indicate the half-duplex mode. A twisted pair cable must be connected into an RJ-45 port
and the Link (LK) indicator for that port must be ON (indicating there is a powered-up
device at the other end of the cable) in order for a LK LED to provide valid indications
of operating conditions on that port.
1 2 3 4
L
AC
Using the 6KQ (MNS-6K) management software, the user may disable autonegotiation and fix the desired operation of each RJ-45 port. The user may select 10Mb
or 100Mb speed and full- or half-duplex mode per-port as per user requirements. (See
Magnum MNS-6K Software Manual for details info.).
2.2.3 PoE (power pass-through), model P6KQ4-RJ45 (MDIX), 10/100Mb 4-port
The PoE (Power-over-Ethernet) RJ-45 ports are similar to regular RJ-45 ports,
except they have the capability of providing power on each port to power up the PD
devices, per the IEEE802.3af PoE standard. The power-pass-through PoE modules are
www GarrettCom com
..
10
Magnum 6KQ Managed Field Switch Installation and User Guide (04/07)
K
4
K
dependent upon the -48VDC input power to supply the PD power for these RJ-45
(10/100) ports. Each port supplies up to 15watts to power the PoE PD devices. A
maximum of 8 PoE ports can be configured in the A and B slots of a 6KQ switch with 48vdc power input. The PoE modules are also available with mix–n-match fiber modules
configured in other 6KQ slots. Please check the Configuration Guide and the ordering
information Sec.1.2 for all the various P6K PoE module options.
The LEDs
on
4 Port@ 10/100Mb PoE Copper ports
10/10
F/
P6KQ4-RJ45
1 2 3 4
AC
2
L
1
1
/
ACT
LK
3
PoE
2
10/100
FULL/HALF
4
3
P6KQ4-RJ45- PoE modules are slightly different compared to regular (non-PoE) RJ-45
modules as shown in Fig 2. When the PoE port is in use, the PoE LED is ON when
connected properly to an 803.af compliant PD device on that port. When non-PoE
devices are connected, the PoE LED is OFF. The operation of Ethernet data traffic is not
affected by PoE.
LINK and ACTIVITY LEDS are combined on the PoE modules into one LED that is
marked as LINK/ACT, as shown in the diagram.
2.2.4 Two-Port Fiber Modules, 2@ 100Mb fiber
The two-port modules are available as two 100Mb fiber ports. ST or SC connector
styles are available utilizing multi-mode or single-mode fiber optics. These fiber
modules may be factory configured with a choice of them in slot B and D only.
The fiber port’s LEDs indicate status the same as the SFF fiber modules in Section 2.2.2
above. Color-coding on the panel of the module shows which LEDs belong to which
port.
F/
ACT
F/
TX RX
L
ACT
F/
TX LK RX
2@ 100 Mb SC 2@ 100 Mb ST
ACT
ACT
F/
TX RX
L
ACT
F/
TX LK RX
www GarrettCom com
..
11
Loading...
+ 39 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.