Garrett MT 5500, 1167700 MT 5500, 1167720 MT 5500 International User Manual

USER MANUAL
MT 5500
Model 11677xx
USA
Garrett Metal Detectors Security Division 1881 W. State Street Garland, Texas 75042-6797 USA
International
Garrett Metal Detectors International Security Division 1881 W. State Street Garland, Texas 75042-6797 USA
MANUFACTURER CAUTION
Read Thoroughly Before Operating
CAUTION! Use of this equipment in a manner not specified by the manufacturer may result in damage to property or injury to persons.
Electrical: 100 – 240 V~ +10% – -15%
1.0-.5A
50/60 Hz Installation Category: II Pollution Degree: 2 Maximum Relative Humidity: 95% non-condensing Operating Temperature: -4ºF (-20ºC) to +158ºF (70ºC) Maximum Altitude: 3000 meters
CAUTION! To reduce the risk of injury to persons or property damage due to accidental knock down, the Stabilizer Base (PN 1603900, not included) must be installed.
Warning! Battery Safety: The optional Battery Backup Module and the CMA Interface module contain rechargeable batteries that may contain small amounts of harmful substances.
• Caution: Do not short circuit. Serious burns may result
• Caution: Do not dispose of batteries in a fire. They may explode
• Caution: Do not open or mutilate batteries. They may contain an electrolyte which is toxic and harmful to the skin and eyes.
• Caution: Replace batteries with the same type and number of batteries as originally installed in the equipment.
• Caution: Do not put the batteries in trash that is disposed of in landfills. When disposing of the battery, comply with local ordinances or regulations and your company’s safety standards.
• Recycling centers and retailers with recycling programs may be found at www.rbrc.org.
SYMBOLS:
Garrett Metal Detectors and garrett.com are trademarks and registered trademarks of Garrett Electronics, Inc. If further assistance is required, please contact the factory using the contact information on the front cover.
Alternating
current
Protective conductor
terminal
CAUTION!
Risk of electric
shock
CAUTION!
Refer to accompanying documentation
Recycle
MT 5500
User Manual
©2006 GARRETT METAL DETECTORS 3 PN 1530200 REV F
MEDICAL SAFETY
Garrett Metal Detectors makes every effort to ensure its products are safe for use. Extensive research by Garrett has produced no information which would indicate that its products have any adverse effects on medical implants, pregnancy, recording media or magnetic strips. Garrett cooperates with medical device manufactur­ers and agencies such as the United States Food and Drug Administration and Health Canada as a means of assuring product safety. The electromagnetic fields produced by Garrett products are similar to those encoun­tered in the daily environment and meet U.S. and International standards for electromagnetic emissions.
Garrett recognizes that certain medical devices may have additional requirements which may require special care. Any recommendations or directives issued by personal physicians or medical device manufacturers should be followed. If, for any reason, (e.g. doctors orders, etc.), a patron objects to being scanned with a metal detector, it is recommended that alternative procedures be used.
The following should be considered when developing a security checkpoint screening plan:
Traffic Flow - Traffic flow should remain unobstructed as a means of minimizing the time a per-
son remains within the archway of a walk-through metal detector.
Alternative Screening - Alternative screening methods such as scanning with a hand held
metal detector, hand searching or denial of access should be clearly defined in checkpoint screening procedures as approved alternatives to screening with the walk-through metal detec­tor.
Personnel Training - Security screening personnel should be instructed in the care of persons
with special medical needs and use of alternative screening methods that meet the requirements of medical practitioners or medical device manufacturers.
MT 5500
User Manual
© 2006 GARRETT METAL DETECTORS 4 PN 1530200.F.0506
TABLE OF CONTENTS
1. GENERAL DESCRIPTION 6
2. CONTROLS & MODULES 8
2.1 DISPLAY PANEL 8
2.2 TOUCHPADS 9
2.3 INTERNAL MODULES 10
3. INSTALLATION INSTRUCTIONS 12
3.1 SITE SELECTION 12
3.2 ASSEMBLY 12
4. SELF-DIAGNOSTIC TESTS 15
5. INSTALLATION ADJUSTMENTS 17
6. SUPERVISOR ADJUSTMENTS 19
7. SUPERVISOR RESPONSIBILITIES 21
8. TECHNICAL SPECIFICATIONS 23
9. MAINTENANCE & REPAIR 26
9.1 PERIODIC MAINTENANCE 26
9.2 REPAIR 26
9.3 MODULE REPLACEMENT 26
9.4 REPLACEMENT PARTS 29
9.5 WARRANTY 30
10. OPERATING INSTRUCTIONS 31
11. ADDITIONAL INFORMATION 37
11.1 OPERATIONS WORKSHEET 37
11.2 PROGRAMS 38
11.3 MULTIPLE UNIT OPERATION 40
11.4 AC & DC CONTROL 41
11.5 REMOTE CONSOLES 42
11.6 BATTERY BACK-UP MODULE 43
11.7 STABILIZER BASE 44
11.8 ELECTRICAL WIRING 45
MT 5500
User Manual
©2006 GARRETT METAL DETECTORS 5 PN 1530200.F.0506
1. MT 5500 GENERAL DESCRIPTION
The Garrett MT 5500 Walk-Through Metal Detector features multi-dimensional, microprocessor-controlled cir-
cuitry and LCD presentation of all calibrating and operating information. It is capable of remote operation and
monitoring, when required, and is designed to be easily portable. The unit can be operated on battery power
alone through use of an optional battery pack, which further enhances its portability.
The detector is manufactured by Garrett Metal Detectors in Garland, Texas.
The MT 5500 uses microprocessors in both its detection and control circuitry. These integrated circuits contain
the necessary elements of a small digital computer and are preprogrammed to provide discrimination capabili-
ties that enable the MT 5500 to optimally detect weapons and other devices made of metal. At the same time,
multi-dimensional detecting informs the operator whether a target being detected is on the left, right or
center/balance of the detector. Multi-dimensional detecting increases throughput dramatically by minimizing
false alarms and the “down-times” that results from them.
The microprocessors permit the MT 5500 to be considerably more sophisticated in its programming and pro-
vide greater flexibility in the selectivity of the metals it detects. The detector also features excellent sensitivity,
stability and noise rejection. All electronics are built into an overhead panel of the unit to eliminate problems of
logistics and reliability often associated with a cable-connected console.
The LCD display on the face of the detector's overhead panel, backlit for easy viewing, reports information con-
cerning the unit’s calibration and operation. This includes program data, sensitivity settings, operator settings
and fault indication. Two bright LED bar graphs, easily visible from a distance, give an indication of the strength
of the alarm and report whether its is on the left or right side of the unit or in the middle. The audible alarm has
three distinct tones to reflect this positional detecting. Separate lights indicate ready and alarm conditions. All
regulation and control functions are “self-prompting” with necessary commands shown automatically on the
LCD. The unit also reports a traffic count on its LCD.
The system offers highly flexible capabilities with a continuously variable range of programs, including sever-
al that have been designed for specific purposes. Programs are regulated by state of the art touchpads and
reported visually on the LCD. Improved security of the unit’s detection settings comes from an advanced sys-
tem of access codes. Two levels of codes eliminate the need for bothersome keys for locked doors or other
protective devices, while the MT 5500 circuitry provides precise accuracy of calibration. Access Code #1 is
used by supervisors for selecting programs and sensitivity with Access Code #2 designed for initial set up and
overall control. All settings are encoded by touchpads and remembered in any resettable memory. Security of
the unit’s calibration settings is further protected by a non-resettable sequence code that allows supervisors to
MT 5500
User Manual
© 2006 GARRETT METAL DETECTORS 6 PN 1530200.F.0506
keep a log of all changes that are ever made as well as any unsuccessful attempts to change them. In addi-
tion, a tamper indication reports any unauthorized or incorrect attempts at access.
A complete and automatic self-diagnostic program is carried out by the MT 5500 each time the Operate touch-
pad is pressed. In addition, the detector utilizes self-testing circuitry that continuously monitors the critical func-
tions of the detector, reporting automatically the failure of any element that would affect operation of the unit.
MT 5500
User Manual
©2006 GARRETT METAL DETECTORS 7 PN 1530200.F.0506
2. CONTROLS & MODULES
2.1 DISPLAY PANEL
2.1.1 LED BAR GRAPHS
The two LED displays located on the Control Panel indicate the detection intensity which is based on the amount and composition of metallic objects passing through the unit.
2.1.2 READY LIGHT
This green light appears when power is turned on and the unit is ready to operate. The light will also indicate when an individual inspection has been completed by the unit and it is ready to accept the next person. Operators should make certain the green light is visible before any individual is permit­ted to pass through the detector.
2.1.3 LCD PANEL
Large alpha/numeric LCD, backlit for easy viewing, reports all operating, setup and diagnostic infor­mation of the unit. Because the unit is designed to be “user-friendly”, all regulation and control func­tions are self-prompting with necessary commands shown on the LCD display.
2.1.4 ALARM LIGHTS
These red lights appear when the unit detects a targeted amount of metal on an individual, accord­ing to specifications of the Program and Sensitivity levels that have been selected. If only one light appears, it will indicate which side (left or right) of the passageway the largest target can be found. When both lights appear, the target(s) are centered, or balanced, within the archway. The lights will appear even when Audio volume has been turned OFF. Operators should be instructed to respond to all alarms. For any detector to be effective in a security system it is absolutely necessary that the cause of EVERY ALARM be determined.
MT 5500
User Manual
© 2006 GARRETT METAL DETECTORS 8 PN 1530200.F.0506
2.2 TOUCHPADS
Eight touchpads on the overhead Control Panel perform all control functions:
2.2.1 ON / OPERATE / TEST
Whenever this touchpad is pressed, the MT 5500 activates all circuits, initiates a self-diagnosis pro­gram and places the unit in the Operate Mode. This diagnostic program for instant fault detection can be activated at any time by touching the OPERATE touchpad. If any faults are ever found, they will be immediately reported on the LCD display. (See Section 4).
2.2.2 OFF
When this touchpad is pressed, the unit is turned OFF. All information and settings are stored in memory and the unit is ready to be returned to full operation instantly when the OPERATE touch­pad is pressed.
2.2.3 COUNTER
When this touchpad is pressed, the traffic count is displayed on the LCD display. Pressing and hold­ing this touchpad for ten (10) seconds causes the counter to return to zero (0). Whenever the LCD is displaying information other than the current traffic count, pressing this touchpad will cause the count to appear along with the Sequence Number of changes that have been made to Program/Sensitivity settings. CT (Number) and SEQ (Number) will appear. Each time the Program/Sensitivity Mode (ACCESS touchpad) is accessed, the Sequence Code that appears on the LCD will be advanced one number. It is recommended that a written notation be made on the Operations Worksheet (see Section 11.1) whenever this code is accessed, explaining reasons for the access. If the ACCESS touchpad has been pressed and an improper access code has been entered, a * will appear before the sequence number (SEQ *37). This indicates that an unsuccess­ful (unauthorized) attempt has been made to gain access to the Program/Sensitivity setting.
2.2.4 VOLUME
When this touchpad is pressed, the volume level of the unit’s audible alarm will be shown on the LCD display and the actual volume of the alarm will be heard. The + and - touchpads can be used by operators to raise or lower the volume. Press OPERATE to return to the operate mode.
2.2.5 + AND -
These touchpads will be used to increase or decrease various numerical settings and for certain ON / OFF functions.
MT 5500
User Manual
©2006 GARRETT METAL DETECTORS 9 PN 1530200.F.0506
2.2.6 PROGRAM
When this touchpad is pressed, the settings for Program and Sensitivity will appear on the LCD dis­play.
SPECIAL NOTE: The above touchpad functions will be available to operators of the detector at all times. Additional functions such as program and sensitivity settings and other adjustments neces­sary only at installation time may be selected by pressing the ACCESS touchpad and entering a security code.
2.2.7 ACCESS
The ACCESS touchpad will be used only by supervisory management personnel. It permits chang­ing the Program and Sensitivity codes and also is used to control such functions as synchronization of multiple units, pulse frequency, tone, etc. (See Section 5.3). The unit further protects security of control settings by maintaining a non-resettable sequence code that indicates any attempt at seek­ing access to the settings. When this touchpad is pressed, audio of the system will “chirp” and ENTER CODE will be displayed on the LCD, prompting the operator to enter an access code. If no attempt is made to enter a code, the unit will continue chirping for ten (10) seconds and return to Operate Mode. If the operator enters an incorrect code, audio will sound a Tamper Alarm and ACCESS DENIED will appear on the LCD for five (5) seconds. An asterisk (*) will appear on the Sequence Counter indicating that an unsuccessful attempt has been made to access the Installation or Program/Sensitivity Modes of the unit.
Operator’s should never touch this control. If an operator should inadvertently press the ACCESS touchpad, no further action should be taken and the unit will return automatically to the Operate Mode in about ten (10) seconds.
2.3 INTERNAL MODULES
2.3.1 CONTROLLER MODULE
This module (in the center) contains all circuit boards necessary for operation of the detector. Two cables (A and B) that connect this module to the side panels are to be plugged into the connectors at the top of each panel. The cover of the Controller Module never needs to be removed except for:
Connecting wires to remote alarm relays or synchronization circuitry (See Section 11.3);
Connecting a remote console (See Section 11.5);
Attaching the optional battery back up (See Section 11.6);
Resetting to factory default Access Code (See Section 5.9).
Shown on the following page is a view of the detection unit after the access door has been opened. Three metal covers protect (from left) the POWER SUPPLY Module, CONTROLLER Module and the
BATTERY PACK Module (Optional).
2.3.2 POWER SUPPLY MODULE
This module contains all circuitry that relates to the power required for operation of the detector. The Power Cord should be plugged into the Power Supply Module at the connector on the lower left side.
MT 5500
User Manual
© 2006 GARRETT METAL DETECTORS 10 PN 1530200.F.0506
2.3.3 BATTERY PACK MODULE (OPTIONAL)
This module, which includes batteries and charging circuitry that comprise the optional battery pack, can provide 16 to 20 hours of continuous operation. The pack has a battery-monitoring circuit, which will allow the battery to be charged within 12 hours and will then switch to trickle charge to maintain a fully charged condition without damaging the batteries.
MT 5500
User Manual
©2006 GARRETT METAL DETECTORS 11 PN 1530200.F.0506
3. INSTALLATION INSTRUCTIONS
3.1 SITE SELECTION
The Garrett MT 5500 should be located on a level, stable floor with no large metal items within three (3) feet. Any nearby large metallic object can interfere with operation of the detector. Moving metal­lic objects, such as an escalator or revolving door, close to the detector can cause false alarms. Such alarms can also be caused by electrical interference from radio telephones, television monitors, pow­erful electronic motors and transformers, power cables and control circuits. A stabilizer base (PN 1603900 - not included) is required to stabilize the detector and help prevent the unit from being pushed over. Be sure to follow installation directions carefully. (See Section 11.7).
Garrett’s special built-in circuitry is designed to suppress much of this electronic noise, especially X­ray monitor horizontal synchronization signals and closed circuit television. Multiple frequencies per­mit several MT 5500 units to operate simultaneously, in close proximity.
For information concerning the operation of multiple units, see Section 11.3.
The site for a MT 5500 should be selected with requirements for its pedestrian traffic and use in mind; i.e. space for waiting lines, operators and areas for hand-scanning. Locate the archway where it will not be subject to rain, mist or condensation. Protect the power cable from pedestrian as well as vehicular traffic.
3.2 ASSEMBLY NOTE: COMPLIANCE WITH REGULATORY STANDARDS REQUIRES THAT A CORD SET BE USED FOR INSTALLATION.
3.2.1 Lay out the major pieces of the MT 5500, as shown at the right. Make certain all other attachment
devices are included. These should include:
• Detection Panel A
Detection Panel B
Detection Unit
Crosspiece
Power Cord
1/4-20x3” Screws (8)
Finishing Washers (8)
User’s Manual
Operator’s Manual
Access Code Card
Instruction Video
• Cord Set
MT 5500
User Manual
© 2006 GARRETT METAL DETECTORS 12 PN 1530200.F.0506
3.2.2 Install the Power Cord completely through one of the channels at the top of either of the Panels
as shown below. A channel can be found in each of the four corners. Select the corner that will be convenient in relation to site selection. For overhead power connection, do not insert the cable through a channel but leave it free at the top.
If using cord set, it can only be routed through the channel closest to the Power Module (as shown) and out of the bottom of the panel. The standard power cord is then plugged into the Cord Set.
3.2.3 Place the styrofoam packing material on floor as shown and lay the Detection Unit on it with the
touchpad panel facing down. Use four (4) of the Screws and Finishing Washers to connect the Detection Unit to Panels A and B. Do not tighten.
3.2.4 Open door of the Detection Unit and, first, connect Power Cord. Then, connect Cable A and
Cable B to the Panels as shown.
MT 5500
User Manual
©2006 GARRETT METAL DETECTORS 13 PN 1530200.F.0506
3.2.5 Use the remaining screws and washers to attach the Crosspiece to the two panels, as shown.
3.2.6 Tighten all eight screws securely with a slotted screwdriver.
3.2.7 With two or more people lift to a vertical position and move to location.
3.3.8 Check for stability of unit, which is important for proper operation and safety. If the floor proves
to be uneven, either shim a corner or slightly loosen the screws connecting the Detection Unit and Overhead Crosspiece to the Side Panels and adjust as necessary.
3.3.9 Connect to the power line, and proceed with Installation Adjustments (See Section 5.)
MT 5500
User Manual
© 2006 GARRETT METAL DETECTORS 14 PN 1530200.F.0506
4. SELF-DIAGNOSTIC TESTS
The Garrett MT 5500 LCD panel provides valuable information concerning the operation of this unit and the self-diagnostic program of which it is capable.
4.1 OPERATING INFORMATION
When the unit is placed into operation from the OFF Mode, the following information is reported:
1. Garrett Security Systems
2. Self-test
3. Battery % (if battery option is in use.)
4. Operate
When the OPERATE touchpad is pressed again, the following information is reported:
1. Serial Number of the unit will be displayed.
2. Software Version of the unit will be displayed.
3. 50 Hz or 60 Hz will be displayed.
4. SYNC MASTER or SLAVE will be displayed, indicating current status.
5. CHANNEL designation will be displayed, indicating current status.
6. Program and Sensitivity levels (PROG D SENS 165 will be displayed initially), indicating current status.
7. Self-test
8. Battery % (when Battery Option is in use.)
9. Operate
NOTE: Serial number will be displayed as long as the OPERATE touchpad is pressed.
4.1.1 SELF-TEST INFORMATION
After the sequence listed above is completed, as well as any time the OPERATE SELF-TEST touch- pad is pressed, a system self-test procedure will be performed. The following information will be dis­played on the Display Panel, as necessary. SELF-TEST will be displayed as the unit tests itself automatically. If any of the following six errors are detected, they will be displayed as shown below:
Example: SELF-TEST...3..4 (Indicates that both Error 3 and Error 4 are occurring.)
4.1.2 CORRECTIVE ACTIONS
4.1.2.1 Error 1: Power failure
Check line voltage and externally connected devices.
4.1.2.2 Error 2: IR Emitter failure
Check connector to Panel A.
4.1.2.3 Error 3: IR Receiver failure
Check connector to Panel B; check for blockage of IR beam at waist level of unit.
4.1.2.4 Error 4: Receiver Balance problem
Check for large metal objects near panels.
4.1.2.5 Error 5: Transmit Energy out of range
MT 5500
User Manual
©2006 GARRETT METAL DETECTORS 15 PN 1530200.F.0506
Check all connectors; check for very large object near Panel A.
4.1.2.6 Error 6: No Line Sync
If unit is in Slave Mode, check synchronization cable; otherwise, verify that the unit is set to Master. If an error occurs, follow the procedures noted above and press OPERATE to retest. You will be prompted SELF-TEST OK when all functions are correct. If problems continue to occur, consult with your supervisor or factory representative.
The self-diagnostic/reporting cycle described above will be carried out automatically by the unit any time the OPERATE touchpad is pressed.
4.1.3 FATAL ERRORS
The system continuously performs several of the tests described above. Errors 1,4 and 5 severely limit or prohibit acceptable performance of the MT 5500 and are considered Fatal Errors.
If a fatal error is encountered because of component failure, broken wire, etc., the audible alarm will sound and the LED display will begin to flash. To remedy the situation, press the OPERATE touch- pad, which will initiate the self-diagnostic routine. Note the error(s) that will appear on the LED and follow instructions stated above. If a solution is not obvious, it will be necessary to follow the repair procedure described in Section 9.2.
4.1.4 NON-FATAL ERRORS
Errors 2, 3, and 6 may also occur. These failures do not limit the system’s detection capabilities and the unit will continue to operate. Although the equipment is usable, it is important to identify and cor­rect all problems as soon as possible in order to maintain full performance capabilities.
Another error indication is that of a warbling audio when a person is in the archway (or, for an extend­ed time if the IR Analysis is switched off). This sound indicates that a large metallic object, such as a wheelchair, stroller, or very large hand-carried object, has “overloaded” the equipment to a degree that it cannot function accurately. If this sound is heard, the operator should see that the problem object is moved away, and the person being inspected should be required to pass through the arch­way again after the green READY light appears.
MT 5500
User Manual
© 2006 GARRETT METAL DETECTORS 16 PN 1530200.F.0506
5. INSTALLATION ADJUSTMENTS
The Installation Adjustment Mode, which can be accessed only through use of a four-digit code (Access Code #2), permits the MT 5500 to be set up properly for best performance in a given oper­ational environment. Various options permit setting the unit for proper operation in conjunction with other walk-through units or for dealing with typical operation problems.
Default settings, preset at the factory, are indicated below for each of the functions in this mode. Use the + or - touchpads to regulate any of the functions.
To access the Installation Adjustment Mode for the first time, press the ACCESS touchpad and enter the factory preset code of 5678. Functions to be set will be displayed in the following sequence: Pressing ACCESS will scroll through these selections:
5.1 RECEIVER BALANCE
RX BALANCE will be displayed, indicating the balance of the receiving antenna. A number less than 50 is acceptable. If the number is greater, check the areas around the detector for large metal objects. If such objects are found, either move the object(s) or move the detector to eliminate a potential problem.
Press ACCESS for next adjustment or OPERATE to return to normal operation.
5.2 TONE
The alarm tone is initially set at a median level. Through use of the + and - touchpads the tone level can be raised or lowered. A corresponding number (1 to 9 ) will be displayed on the LCD panel and the tone that has been selected will be heard. Each tone level number contains tones of two differ­ent pitches, low and high. The pitch of the desired tone is used to indicate left side or right side direction. When the desired tone is reached, press ACCESS to select the next adjustment or press
OPERATE to return to normal operation.
5.3 SYNCHRONIZATION
Preset factory option is MASTER. See Multiple Unit Operation in Section 11.3 for directions on prop­er use of this option when it is necessary.
MASTER enables the unit to operate on its own internally generated synchronization from the power line.
SLAVE synchronizes the unit to the signal received from another MT 5500 on the Sync terminal (on the lower center of the Controller Circuit Board).
Press ACCESS for next adjustment or OPERATE to return to normal operation.
5.4 CHANNEL
This feature will allow multiple units to operate in close proximity. It is recommended that when two (2) MT 5500 units are operated in close proximity that Channels 1 and 2 are used. If three (3) or more MT 5500 units are operated in close proximity, use Channels 1, 2 and 3. (Section 11.3). Press
ACCESS for next adjustment or OPERATE to return to normal operation.
5.5 VIDEO FILTER
This filter permits the unit to function effectively in proximity with video terminals of all types, com­puter, broadcast, closed circuit, etc. This filter may not apply to certain non-synchronous noise
MT 5500
User Manual
©2006 GARRETT METAL DETECTORS 17 PN 1530200.F.0506
sources. Settings from 1 to 63 are possible through the use of + and - touchpads. If noise is observed at your desired operating sensitivity, increment the Video Filter settings to locate the set­ting with least interference as observed by fluctuation of the Bar Graph.
Press ACCESS for the next adjustment or OPERATE to return to normal operation.
5.6 RELAY
This feature allows the AC and DC relay circuits to be changed easily to Normally Open (N/O) or Normally Closed (N/C) to meet installation requirements. Use + and - touchpads to select RELAY N/C or RELAY N/O (See Section 11.4). Press ACCESS for next adjustment or OPERATE to return to normal operation.
5.7 ALTER ACCESS CODE #1
This Supervisor Adjustments Code has been preset at the factory at 1234. To change this code:
1. Press the + touchpad.
2. Enter a new four-digit code.
3. The LCD display will prompt REPEAT CODE. 4 . Enter the same four digits of the new code and it will be set and CODE ENTERED OK will be
displayed. (If different digits are entered, the display will indicate INVALID ENTRY, and steps 2, 3 and 4 must be repeated.)
Press ACCESS for next adjustment or OPERATE to return to normal operation.
5.8 ALTER ACCESS CODE #2
This Installation Access Code has been preset at the factory at 5678. To change this code:
1. Press the + touchpad.
2. Enter a new four-digit code.
3. The LCD display will prompt REPEAT CODE.
4. Enter the same four digits of the new code and it will be set and CODE ENTERED OK will be displayed. (If different digits are entered, the display will indicate INVALID ENTRY, and steps 2, 3 and 4 must be repeated.)
5. Press OPERATE to exit the Adjustment Mode and enable the detector to be operated normally. If ACCESS is pressed, this Installation Adjustment cycle will be repeated, beginning with Receiver Balance.
5.9 RESETTING FACTORY DEFAULT ACCESS CODES
If a code number is ever lost or forgotten, codes may be reset to factory default settings through the following procedure:
Open the main cover of the Detection Unit;
Remove the three (3) screws that hold the Controller Circuit Board cover;
With power connected and the unit in its Operate Mode press the Access Code Reset button in
the upper center of the circuit board.
ACCESS CODE #1 will again be 1234 and ACCESS CODE #2 will be 5678.
SPECIAL NOTE: For maximum security it is recommended that both Access Code numbers be
changes from the factory default settings and that the numbers be known only to those who use them. Record the new code numbers on the Access Settings card that accompanied this Owner’s Manual. It is also suggested that codes be changed periodically, especially when any changes are made in personnel with access to the codes.
MT 5500
User Manual
© 2006 GARRETT METAL DETECTORS 18 PN 1530200.F.0506
6. SUPERVISOR ADJUSTMENTS
Several adjustments may be made at the Supervisor’s Level (Access Code #1). These are primari­ly program/sensitivity settings and the operation of the IR Sensor. These supervisor’s adjustments can be accessed only through use of a four-digit code (See instructions for altering Access Code #1 under Installation Adjustments, Section 5.7)
To access the Supervisor Adjustment Mode for the first time, press the ACCESS touchpad and the factory preset code of 1234. The factory default settings of PROG D SENS 160 will be displayed on the LCD with the program designation blinking. Pressing the ACCESS touchpad will permit scroll­ing through these selections.
6.1 PROGRAM
The programs detailed in Section 11 have been developed for use by the Garrett MT 5500. These brief descriptions will give some indication of the intent of each program, but a final judgment on the setting of each individual unit should be determined by the intent of its installation. After the Program number is accessed through use of the four-digit code, + touchpad can be used to increase the num­ber, and the - touchpad to lower it. Press ACCESS for next adjustment or OPERATE to return to normal operation.
CAUTION - The MT 5500, as with all walk-through metal detectors, has several available programs. The user may find that a different application (weapons detection, loss prevention, high or low vol­ume, etc.) may be best served with one or more of these programs.
Garrett engineers have developed a special program (Program D) which minimizes the cancellation (masking) effect which can be experienced when certain materials of differing composition pass through the archway. It is recommended that this program be considered any time the system is employed for weapons detection.
6.2 SENSITIVITY
This option permits the unit to be adjusted (range of 1 to 200) to the proper level of sensitivity with­in a chosen program. Press ACCESS until the SENS and the number are displayed on the LCD. Use the + and - touchpads to adjust the number. Sensitivity of detection will be increased as the number is made larger, allowing alarm responses on smaller targets.
After the desired Sensitivity number has been selected, press ACCESS for next adjustment or
OPERATE to return to normal operation.
6.3 IR ANALYSIS
The Garrett MT 5500 utilizes an Infrared Sensor to enhance the operation of the unit in special sit­uations. IR Analysis — ON or OFF appears on the LCD to indicate whether or not the IR Analysis is being used. The + or - touchpad is used to turn the IR Analysis OFF and ON. Whenever this is done, it is necessary to press ACCESS for the next adjustment or OPERATE to return to normal operation.
Utilization of the Infrared Sensor is not required for operation of the MT 5500 and may be disabled if desired.
Several benefits of the sensor are:
1. The units can operate more effectively by correlating signal responses with actual physical movement. Because this sensor enables the MT 5500 to detect just those individuals and
MT 5500
User Manual
©2006 GARRETT METAL DETECTORS 19 PN 1530200.F.0506
objects while they are passing through the detector, it can minimize effects of noise and other influences.
2. By inhibiting the alarm when no one is in its archway, the IR Analysis greatly minimizes nuisance alarms. In instances where there is movement of large metal objects near the exterior of the unit, such as when luggage or supply carts pass by, or when lack of space requires the unit to be placed very near a conveyor belt of parcel X-ray equipment, the sensor will effectively inhibit alarms.
3. The IR Analysis provides a warning any time a person passes through the archway when the unit is in the Set-Up or Self-Test Mode.
4. The IR Analysis enables the detector to count the number of individuals passing through it.
6.4 ALARM LEVEL READING
Computerized circuitry of the Garrett MT 5500 permits the unit to report the minimum sensitivity level required to cause an alarm for the particular metallic target that is being passed through the arch- way. This information can then be used to regulate the unit.
Press the ACCESS touchpad until PLEASE WAIT appears on the LCD Display, followed by ALARM LEVEL and a number. The target in question should then be passed through the unit. Note the Alarm Reading number that then appears on the LCD. This is the Sensitivity level that will be necessary for the unit to sound an alarm on this target. Press the + touchpad to reset the indicator after each meas­urement. It is recommended that several measurements of each object in question be made at var­ious archway positions to obtain the optimum sensitivity level setting.
Press ACCESS for next adjustment or OPERATE to return to normal operation.
6.4.1 TYPES OF AUDIO ALARMS
Understanding the different audio alarms that the MT 5500 produces will enable both supervisors and operators to understand the detector better and help assure totally accurate screening. Each of three basic types of audio alarms is designed to call the operator’s attention to current circum-
stances.
6.4.1.1 SET UP ALARM
Produces two short beeps as a person is walking through the unit. This alarm indicates that the metal detector is in a set-up mode and is not ready for operation. Wait for the green READY light (press OPERATE, if necessary). Person(s) who triggered the Set-up alarm must pass through the unit again.
6.4.1.2 STANDARD ALARM
There are three (3) different standard alarms, with tonal differences to indicate whether the target is on the left side, right side or center / balanced within the archway. One of these alarms will sound when the red ALARM light appears and a target amount of metal is detected according to Program and Sensitivity levels.
6.4.1.3 WARBLE ALARM
Occurs when a large metal mass, such as a wheelchair, furniture or large metal container is moved through or near the MT 5500. The large amount of metal has saturated the detector's receiver circuits and the warble alarm is an indicator that the operator should correct the situation before allowing anyone to pass through the metal detector.
MT 5500
User Manual
© 2006 GARRETT METAL DETECTORS 20 PN 1530200.F.0506
7. SUPERVISOR RESPONSIBILITIES
7.1 CALIBRATION
Calibration settings of walk-through metal detectors are dependent upon individual security screen­ing requirements and, therefore, must be the responsibility of the screening installation. Program and Sensitivity settings should be established at a level that permits the detector to detect all forbidden objects that can be reasonably expected to appear at a particular screening station. Actual forbidden objects should be used as targets for initial calibration.
7.2 FAA TEST PIECE
Garrett manufactures an Operational Test Piece (OTP) made to the specifications of the U. S. Federal Aviation Administration (Garrett Accessory #1600600). This piece is intended to simulate a small firearm.
If the OTP does not represent a specific security requirement then a different test piece(s) should be considered.
7.3 TESTING
It is imperative that a standard test program be developed for walk-through metal detectors within a security system. The various tests should be made on a regular basis to ensure that each unit is properly calibrated and is detecting metal. The OTP has been designed to serve as a basic instru­ment for use in such a test program.
A test program should include passing the OTP and/or other objects through each metal detector at various specified heights and horizontal positions, with the OTP (objects) held in different orienta­tions. The number of repetitions required at each level with corresponding successful alarms should be established, and this testing system should be adhered to consistently.
Included in the test procedure should be the requirement that the tester be free of all metallic items, including shoe shanks, prior to arming himself with the OTP. A hand-held metal detector can be used to confirm that the tester is “clean” of extraneous metallic items.
7.4 ANKLE BOOST
The MT 5500 incorporates the ability to adjust the sensitivity at ankle level without increasing sen­sitivity throughout the passageway. The factory setting is with standard ankle boost to allow easier passage of shoes containing metal shanks. Two additional levels of boost are available for higher levels of security.
This adjustment should be used only when sensitivity at ankle level needs to be increased.
7.4.1 PROCEDURE:
Disconnect the unit from AC power source (switch off battery back-up module, if installed);
Open access door of detection unit;
Remove the three (3) screws that hold the controller cover:
• Move jumpers as shown in the diagram on Figure 7.4.1 to achieve the required level of boost (all jumpers must be set to the same level);
Replace cover and reconnect power;
Test unit to assure desired performance level.
MT 5500
User Manual
©2006 GARRETT METAL DETECTORS 21 PN 1530200.F.0506
7.4.2. APPLICATIONS:
• High: High sensitivity; low traffic volume
Medium: High Sensitivity; high traffic volume
Standard: Normal sensitivity; high traffic volume
NOTE: Ankle level sensitivity can be adjusted for any program / sensitivity selection.
MT 5500
User Manual
© 2006 GARRETT METAL DETECTORS 22 PN 1530200.F.0506
Figure 7.4.1
8. TECHNICAL SPECIFICATIONS
8.1 ELECTRONICS
Digital-controlled pulse induction metal detector with multi-dimensional detection; target location dis­cernible on left, right or center of detector; microprocessors utilized in both detection and control cir­cuitry. Electronics are modular and designed for easy plug-in and change.
8.2 DETECTION FIELD
The multiple coil design offers multi-dimensional detection field with total uniformity horizontally and vertically. This coil design plus a choice of 3 levels of ankle level boost eliminates traditional hot spots and weak signals. Target detection is precise, regardless of its location within the archway.
8.3 SELF DIAGNOSTIC
Whenever the unit is turned ON, a self-test of all systems is performed automatically with any fail­ures or problems reported (in words) on the LCD display.
8.4 PROGRAM
Levels: Ultimate versatility; 20 standard programs. Designed for tailoring detection response to ful­fill various security applications.
8.5 SENSITIVITY
1-200 per program for precise target selection.
8.6 MEMORY
All program selections and settings are maintained in electrically erasable non-volatile memory. The unit will maintain all settings even when disconnected from power. No battery is required for mem­ory retention.
8.7 OVERHEAD CONTROL UNIT
LCD Display, LED bar graph and control touchpads plus all wiring, connections and electronics are integrated in a single overhead compartment that eliminates exposed wires and an external control box.
8.8 CONTROL OUTPUTS
Solid state switches (low voltage AC or DC) for operating external alarms and control devices.
8.9 INDICATORS
READY light indicates unit is operational; ALARM lights and audible alarms with variable tones are activated when target amount of metal is detected; location of alarm lights on left and right side of display, combined with variable tone, indicates location of target on individual passing through unit, LED Bar Graphs indicate amplitude of detection response.
8.10 TRAFFIC COUNTER
Built-in and resettable with current reading easily available on LCD panel.
8.11 TAMPERPROOF
Dual-level access codes required to set or change all sensitivity settings and detection program; one level for use by supervisors in selecting programs and sensitivity and the other for initial set-up and overall control. Non-resettable sequence code logs all changes made whenever sensitivity codes are accessed. Audible alarm reports any unauthorized attempt at access.
MT 5500
User Manual
©2006 GARRETT METAL DETECTORS 23 PN 1530200.F.0506
8.12 CONSTRUCTION
Attractive scratch- and mar-resistant laminate with resilient end caps; control panel and crosspieces of heavy duty aluminum.
8.13 REGULATORY STANDARDS
See 8.2.7
8.14 INFRARED SENSOR
Improves analysis of detection signal; increases throughput; helps eliminate “false alarms”; also pro­vides accurate traffic counter.
8.15 INTERFERENCE REJECTION
100% sensor coil Faraday shielding. Unique Garrett built-in circuitry for noise suppression and ignor­ing x-ray monitor horizontal sync. Physical interference minimized by coil and design and circuitry. RFI-EMI filters provide attenuation from 10 MHz to 1000 MHz.
8.16 MASKING
Microprocessor programming designed to minimize the potential problem of detection signals from two or more targets canceling each other.
8.17 SYNCHRONIZATION
Multiple frequencies permit several MT 5500 units to operate simultaneously, in close proximity.
8.18 ELECTRICAL
Fully automatic 100 to 240 VAC, 50/60 Hertz, 55 watts; no rewiring, switching or adjustments required. Power supply meets UL, CSA, TUV and VDE standards. Also complies with IEC standards for Safety Requirements for Electronic Measuring Apparatus and meets the Federal Communications Commission Class B standards for noise emission from commercial electrical equipment.
8.19 OPERATING TEMPERATURES
-4°F (-20°C) to + 158°F (70°C)
8.20 HUMIDITY
To 95 % noncondensing
8.21 THROUGHPUT RATE
Continuous detection means throughput is not limited by electronics; more than 60 detections per minute is reasonable; overal througput is maximized by minimum false alarms and alarm display that assists in locating targets.
8.22 OPTIONAL FEATURES
2225770 - Dual battery back up allows 16-20 hours use with quick recharge (within 12 hours) capability.
2225500 - Remote Control Console allows remote operation up to 50 feet operating capability.
1168000 - Magna Dolly wheel assembly for easy portability.
1603900 - Anti-tilt brackets help prevent tipping and can be used to anchor unit.
MT 5500
User Manual
© 2006 GARRETT METAL DETECTORS 24 PN 1530200.F.0506
8.23 WEIGHT
Approximately 115 pounds (52.1kg)
8.24 WARRANTY
24 months, parts and labor
8.25 MODEL
1167700 MT 5500
1167720 MT 5500 International
8.26 DIMENSIONS
Passageway interior: Width: 30” (0.76m) / Height: 80” (2 m) / Depth: 20” (0.57m)
Overall exterior: Width: 35” (0.9m) / Height: 87” (2.2m) / Depth: 23” (0.57m)
Shipping: Width: 33.5” (.85m) / Height: 91.5” (2.3m) / Depth: 6.25”
(15.9cm) / Weight: 139 lbs. (63kg)
8.27 REGULATORY INFORMATION
The Garrett MT 5500 meets or exceeds detection requirements of the National Institute of Law Enforcement and Criminal Justice Standards #0601.00, levels 1-5, and Federal Aviation Administration airport application specifications. Programs have been designed specifically to meet he three-gun test of the FAA and the requirements of the Undetectable Firearm Act of 1991.
The unit also complies with IEC standards for Safety Requirements for Electronic Measuring Apparatus and meets the Federal Communications Commission Class B standards for noise emis­sion from commercial electrical equipment.
MT 5500
User Manual
©2006 GARRETT METAL DETECTORS 25 PN 1530200.F.0506
9. MAINTENANCE & REPAIR
9.1 PERIODIC MAINTENANCE
Periodic maintenance of the equipment requires only inspection for loose or damaged parts and cleaning of the exterior surfaces.
Open the access door of the Detection Unit and check that all connectors are snapped securely
and that all screws and nuts are in place.
Inspect the windows of the IR Sensor to make certain they are not blocked in any way.
Check to make certain that the eight (8) screws that attach the Crosspiece and Detection Unit to
the Panels are in place and tight.
Check to make certain that the archway sits flat on the floor and does not sway or rock.
If the power cord or cable to remote devices are at floor level, check for frayed or broken wires.
Replace immediately.
Clean exterior surfaces with mild soap and water only. If a solvent is necessary for heavy clean-
ing, use only denatured alcohol.
• Test the detector daily, or whenever the environment changes.
9.2 REPAIR
There are no user-adjustable controls inside the unit.
Should the equipment ever fail to perform properly, contact the seller for the name of the nearest field service representative, or contact the factory.
Because the equipment is of modular design, repairs can often be made through replacement of these plug-in modules. An illustrated parts list follows for your convenience.
If problems are site-related, see Section 3.1 or contact the factory for assistance. Many times these problems may be resolved through the adjustment of the equipment or through relocation of the equipment or surrounding objects.
9.3 MODULE REPLACEMENT
The system is built as a series of modules, each of which can be easily removed and replaced. These modules are tested and calibrated independently, and there is no need for adjustment of any other electronic assembly when a module is replaced.
It is necessary to test the system carefully to verify operation and the suitability of the product after any component replacement.
MT 5500
User Manual
© 2006 GARRETT METAL DETECTORS 26 PN 1530200.F.0506
MT 5500
User Manual
©2006 GARRETT METAL DETECTORS 27 PN 1530200.F.0506
21
15
8
7
14
12
9
13 22
5
12
6
POWER SUPPLY & BATTERY BACK-UP CONNECTORS
ACCESS CODE RESET
FRONT TOUCHPAD CONNECTOR (BOTTOM OF PC BOARD)
RIBBON CABLE CONNECTOR (BOTTOM OF PC BOARD CONNECTOR)
CABLE B CONNECTOR
CABLE A CONNECTOR
MT 5500
User Manual
© 2006 GARRETT METAL DETECTORS 28 PN 1530200.F.0506
16
17
19
10
18
20
11
4
9.4. REPLACEMENT PARTS
MT 5500
User Manual
©2006 GARRETT METAL DETECTORS 29 PN 1530200.F.0506
ITEM DESCRIPTION PART # QTY
1 Access Control Card 1562300 2
2 Operation’s Manual 1529670 1
3 VHS - Instructional Video 1671672 1
4 Detection Unit 2225502 1
5 Panel A 2228070 1
6 Panel B 2227971 1
7 Display Circuit Board Assembly 2335702 1
8 Controller Circuit Board Assembly 2335602 1
9 Power Supply Module 100-240 vac 2326370 1
10 IR Emitter Circuit Board Assembly 2333702 1
11 IR Detector Circuit Board Assembly 2333802 1
12 Cable Assembly, Detection Unit 2400070 2
13 Power Cord 110v 17’ 9411500 1
14 Touchpanel 9419900 1
15 Ribbon Cable-16 conductor, 6” 9504700 1
16 Screw 1/4-20x3” 9820400 8
17 Finishing Washer 9820500 8
18 Screw 4-40-3/8 flat head, light beige 9822980 4
19 Crosspiece 9968800 1
20 Cover with window 9969590 1
21 Controller Cover 9984500 1
22 Cord Set 9424900 1
9.5 WARRANTY
Garrett Electronics, Inc. (“Garrett”) warrants that this MT 5500 weapons/metal detector is protected by the following limited parts and labor warranty for a period of 24 (twenty-four) months (the “Warranty”).
During this 24-month period Garrett will inspect and evaluate all security equipment returned to its authorized repair station or factory to determine if the equipment meets performance specifications. Garrett will repair or replace at no charge to the owner all parts determined faulty. This Warranty does not cover batteries nor any and all failures caused by abuse, tampering, theft, failure due to weath­er, battery acid or other contaminants and equipment repairs made by an unauthorized party.
This warranty is expressly in lieu of all other warranties, expressed or implied, including the warranty of merchantability or fitness for a particular purpose.
The Buyer acknowledges that any oral statements about the merchandise described in this contract made by Seller’s representatives, if any such statements were made, do not constitute warranties, shall not be relied upon by the Buyer and are not a part of this contract for sale. The entire contract is embodied in this writing. This writing constitutes the final expression of the parties’ agreement and is a complete and exclusive statement of the terms of this agreement.
The parties agree that the sole and exclusive remedy against Seller shall be for the repair and replacement of defective parts. The Buyer agrees that no remedy (including, but not limited to, inci­dental or consequential damages for lost sales, lost profits, injury to person or property) shall be available to him.
MT 5500
User Manual
© 2006 GARRETT METAL DETECTORS 30 PN 1530200.F.0506
10. OPERATING INSTRUCTIONS
This Manual is designed to provide all necessary information required for operation of the Garrett MT 5500 walk-through metal detector. It contains four sections:
Description of the detector;
Description of all controls;
Operators’ responsibilities;
Basic operating instructions.
10.1 BASIC INSTRUCTIONS
In addition to following all operating procedures as directed by supervisors the operator of a MT 5500 detector has only these responsibilities:
Assure that the detector is always operating properly;
Select OFF and Operate / ON modes;
Regulate volume of the alarm;
Read and/or reset the counter;
Respond to all alarms.
10.2 LCD REPORTS INFORMATION
The LCD, on an overhead panel of the detector, reports information concerning the unit’s calibration and operation. This includes program data, sensitivity settings, operator settings and fault indication. A bright LED bar graph, easily visible from a distance, reports detection levels and separate lights indicate ready and alarm conditions. All regulation and control functions are “self-prompting” with necessary commands shown automatically on the LCD. The unit also features the capability to report a traffic count on its LCD.
Exact control of the unit’s sensitivity is assured by a system with 200 precise and repeatable steps for each program level, regulated by state-of-the-art touchpads and reported visu­ally on the LCD. Improved security of the unit’s detection settings comes from a totally new system of access codes. Two levels of codes eliminate the need for bothersome keys for locked doors or other protective devices, while the MT 5500’s circuitry provides precise accuracy of calibration never before achieved. Access Code #1 is used by supervisors for selecting programs and sensitivity, with Access Code #2 designed for initial set-up and overall control. All settings are encoded by touch­pads and stored in a resettable memory.
Security of the unit’s calibration settings is further protected by a non-resettable sequence code that allows supervisors to keep a log of all changes that are ever made to the program, sensitivity or set up, as well as any unsuccessful attempt at changing them. In addition, a tamper indication reports any unauthorized attempts at access.
A complete and automatic self-diagnostic program is carried out by the MT 5500 each time the OPERATE touchpad is pressed. In addition, the detector utilizes self-testing circuitry that enables it to identify and report automatically the failure of elements that would affect operation of the unit.
10.3 CONTROLS / LCD DISPLAY
Large alpha/numeric display on the Control Panel, backlit for easy viewing, reports (in words) all reg­ulating, controlling and self-prompting functions of the unit. Because the unit is designed to be “user­friendly,” all regulation and control functions are self-prompting with necessary commands shown on the LCD display. Operators should follow instructions of supervisors concerning responses to these commands.
MT 5500
User Manual
©2006 GARRETT METAL DETECTORS 31 PN 1530200.F.0506
10.4 READY LIGHT
This green light appears when full power has been turned on and the unit is ready to detect. The light will also indicate when an individual inspection has been completed by the unit and it is ready to accept the next person. Operators should make certain the green light is visible before any individ­ual is permitted to pass through the detector.
10.5 ALARM LIGHT
These red lights appear when the unit detects a targeted amount of metal on an individual, accord­ing to specifications of the Program and Sensitivity levels that have been selected. If only one light appear, it will indicate which side (left or right) of the passageway the largest target can be found. When both lights appear, the target(s) are centered or balanced within the archway. The lights will appear even when Audio volume has been turned OFF. Operators should be instructed to respond to all alarms. For any detector to be effective in a security system it is absolutely necessary that the cause of EVERY ALARM be determined.
10.6 TYPES OF AUDIO ALARMS
The MT 5500 has three types of alarms. Each of these unique alarms is designed to call the opera­tor’s attention to current circumstances:
10.6.1 SET-UP ALARM
Produces two short beeps as a person is walking through the unit. This alarm indicates that the metal detector is in a set-up mode and is not ready for operation. Wait for green READY light (press OPER- ATE touchpad, if necessary). Person(s) who triggered the Set-up Alarm must pass through the unit again.
10.6.2 STANDARD ALARM
There are three different standard alarm tones. These tones indicate whether the target is on the left side, right side or center / balanced within the archway. One of these alarms will sound when a red ALARM light appears and a targeted amount of metal is detected according to Program and Sensitivity levels.
10.6.3 WARBLE ALARM
Occurs when a large metal mass (a wheelchair) moves through or near the MT 5500. When a large amount of metal saturates the detector’s receiver circuits the warble alarm indicates that the situa­tion should be corrected before anyone passes through the detector.
10.7 BAR GRAPH
The two LED displays located on the Control Panel indicate the detection intensity which is based on the amount and composition of metallic objects passing through the unit.
10.8 TOUCHPADS
Eight touchpads on the overhead Control Panel perform all control functions.
10.8.1 OFF
When this touchpad is pressed, the unit is turned OFF. All information and settings are stored in memory and the unit is ready to be returned to full operation when the OPERATE touchpad is pressed. Operators should use all touchpads only as instructed by supervisors.
10.8.2 OPERATE
When this touchpad is pressed, the MT 5500 activates all circuits, initiates a self-diagnostic program and places the unit in the Operate Mode within 10 seconds. This diagnostic program for instant fault
MT 5500
User Manual
© 2006 GARRETT METAL DETECTORS 32 PN 1530200.F.0506
detection can be activated at any time by touching this OPERATE pad. If any faults are ever found, they will be immediately reported on the LCD display. (See Section 4.1.1)
10.8.3 COUNTER
Since the current traffic count of the MT 5500 is usually displayed, this touchpad will be needed only for resetting the counter. Pressing and holding this touchpad for ten (10) seconds causes the count­er to return to zero (0). Whenever the LCD displays information other than the current traffic count, pressing this touchpad will cause the count to appear.
10.8.4 VOLUME
When this touchpad is pressed, the volume level of the unit’s audible alarm will be displayed on the LCD display. By using the + and - touchpads, operators can raise or lower the volume.
10.8.5 + AND -
These touchpads will be used to increase or decrease various numerical settings and for certain ON / OFF functions.
10.8.6 PROGRAM
When this touchpad is pressed, the settings for Program and Sensitivity will appear on the LCD dis­play.
All of the preceding touchpad functions will be available to operators of the detector at all times. The
ACCESS touchpad will be used only by supervisors.
10.9 ACCESS TOUCHPAD
Operators never need to use this touchpad. This touchpad will be used only by supervisory man­agement personnel. It permits changing the Program and Sensitivity codes and also is used to con­trol such functions as synchronization of multiple units, pulse frequency and tone. The unit further protects security of control settings by maintaining a non-resettable sequence code that indicates any attempt at seeking access to the settings. A Tamper Alarm sounds within 10 seconds after the ACCESS touchpad is pressed unless a proper access code is entered. Follow supervisors’ instruc­tions concerning response to this Tamper Alarm.
10.10 OPERATORS’ RESPONSIBILITIES
The primary responsibility of any operator is to follow all instructions of supervisors.
These directives will govern the response of operators to alarms and other situations that will be
encountered. The basic continuing responsibility of the operator will be to ensure that the MT 5500 operates properly at all times as indicated by its LCD panel and that ALL alarms are investigated.
Remember that the cause of every alarm MUST be determined.
10.11 OPERATORS’ INSTRUCTIONS
All personnel who are associated with the detector should watch a video presentation on the MT 5500 in addition to studying this User Manual. Carefully following the instructions in the Manual will help ensure the security of any facility this walk-through detector is expected to protect.
As described in the CONTROLS section of this manual, MT 5500 controls are located in the top sec­tion of the archway. If the green READY light is not visible on the control panel, press the OPER-
ATE touchpad. Operators can also adjust volume of the alarm and can reset the traffic counter.
MT 5500
User Manual
©2006 GARRETT METAL DETECTORS 33 PN 1530200.F.0506
10.12 READY LIGHT
The green READY light, located at the top center of the Control Panel indicates that the MT 5500 is operating. When the green light is showing, power has been turned on and the unit is prepared to detect metal.
The green READY light must always be on before anyone is permitted to enter the archway for inspection.
The green light will “wink” whenever anyone breaks the IR beam across the archway or whenever there is a noise “spike.” If the green READY light should ever go off and remain off, however, the operator should immediately press the OPERATE touchpad. The detector will then institute a self- test program with results reported on the LCD display. All traffic through the unit must be halted until the green READY light again appears and remains constant.
10.13 DIAGNOSTIC PROBLEMS
Operators should follow instructions of supervisors concerning their response to any faults ever dis­covered by the MT 5500 in its self-diagnostic program. Two situations that can be immediately reme­died by operators will be indicated by Error 3 and Error 4 on the LCD Panel.
• IR Fail (Error 3): Some obstruction within the unit may be blocking the optical sensor that projects
across the archway. Operator should make certain that the openings for the optical sensor on each side of the archway, approximately 30 inches from the floor, have not been blocked in any way.
• Receiver Balance (Error 4): This problem could be caused by the presence of a large metal
object that has been placed near the unit. Operators should look for such an object and move it.
Even though these actions may temporarily solve the problems discovered by the self diagnostic pro­gram, supervisors should be notified.
While the detector is operating, if a test ever shows a failure that severely limits or prohibits accept­able performance of the unit, the alarm will sound and the LED display will flash. This flashing will continue until power is removed or the cause of failure is corrected.
10.14 RESPONDING TO ALARMS
When an alarm sounds and the red ALARM light(s) go on, the person passing through the detector at that time must either be scanned immediately with a SuperScanner or SuperWand hand-held metal detector or asked to walk through the unit again after removing metal objects from body and clothing. The multi-dimensional natures of the MT 5500 will help locate the position of the metal causing the alarm. The audio and alarm light indicates the side (left, right, center/balanced) that the offending target is located. This allows the operator to search this area first. It is important that after the offending target is located, the operator completes the search of the individual to verify no other targets exist.
If an alarm sounds after the person has removed metal objects, hand scanning is mandatory to find the source of metal sounding the alarm. This metal must always be found before a person can be allowed to proceed.
An operator should take nothing for granted. The source that causes any alarm must be discovered. If a concealed weapon is ever fond, the operator should follow instructions that have been given by supervisors.
MT 5500
User Manual
© 2006 GARRETT METAL DETECTORS 34 PN 1530200.F.0506
10.15 ADJUSTING VOLUME
To adjust the volume of the alarm, the operator should first press the VOLUME touchpad. Then use the + and - touchpads to regulate the volume. Finally, press the OPERATE touchpad to resume nor- mal operations.
10.16 NUISANCE ALARMS
Any metal detector will occasionally register what is called a “nuisance alarm,” triggered by electri­cal or mechanical noise from the environment. On most walk-through detectors such an alarm can sound when a person carrying no detectable metal is passing through the archway, or even when nobody is passing through. Audible nuisance alarms are minimized by the IR Sensor. This sensor requires that a person must be passing through the unit for any alarm to sound. Because the IR Sensor can be turned off by a supervisor, operators should always know whether it is functioning or not.
It is important to remember that after power has been turned on, the MT 5500 is operating at all times. Its IR Sensor capability inhibits the alarm only when there is no object or person within the archway.
No detector, however, is immune from nuisance alarms caused primarily by electrical disturbances from large motors, computers, fluorescent lighting or many other sources. An operator should not be overly concerned about nuisance alarms, but should accept that they can happen and be ready for them. Of course, it will be necessary to retest any person passing through the detector when a nuisance alarm is believed to have sounded.
Because of the high level of design quality represented by the MT 5500 and its IR Sensor, it can be expected to produce relatively few “nuisance alarms” when installed properly. Nevertheless, opera­tors should always follow instructions from supervisors about reporting them.
On rare occasions a nuisance source might trigger the alarm just as someone is passing through the detector. An operator should never try to guess about the source of such an alarm, and it should never be assumed that the alarm is a nuisance. There have been occasions when an individual would intentionally bump against a detector while passing through it and try to blame an alarm on the bump.
If an alarm sounds for any reason while a person is passing through the archway, that person must be asked to walk through the unit again and/or be examined for metallic objects with a hand-held detector.
There will be no exceptions.
10.17 TAMPER ALARM
Whenever the ACCESS touchpad is pressed, the detector will begin “beeping” for about ten (10) seconds or until a four-digit numerical access code is entered with the touchpads. During these ten (10) seconds, the detector will sound an alarm if any person or object passes through the archway. When less than four touchpads are pressed or if no attempt is made to enter a code within ten (10) seconds, the detector will return to normal operation. After the ACCESS touchpad is pressed, if an unauthorized four-touchpad code is entered, an audible Tamper Alarm will sound three loud “beeps.” The detector will then return to normal operation.
Any attempt at access to the detector’s controls will also be indicated by an increase in the SEQUENCE code as reported on the LCD display. Any unauthorized attempt at access that acti-
MT 5500
User Manual
©2006 GARRETT METAL DETECTORS 35 PN 1530200.F.0506
vates the Tamper Alarm will be indicated by this symbol (*) adjacent to the SEQUENCE code num­ber. If the Tamper Alarm ever sounds, an operator should follow supervisor’s instructions.
10.18 COUNTER
If the current traffic count is not being reported on the LCD display, press this touchpad to view it. Pressing and holding this touchpad for ten (10) seconds enables the operator to return the traffic counter to zero (0). Supervisors will issue instructions concerning this control and its use by individ­ual operators.
10.19 SUMMARY
It is important that all operators study the guidelines in this section carefully and remember their basic responsibilities for operating the MT 5500 as stated on the first page:
Make sure power is turned on;
Make certain the unit is operating properly;
Adjust volume of the alarm;
Read the counter;
Respond to all alarms.
Most important of all is the operator’s responsibility to make certain that every alarm be investigated and that the reason for that alarm be determined.
The MT 5500 is a fine walk-through metal detector. But, in the end, even an electronic device as sophisticated as this is only a tool. Ultimate success of its operation is dependent upon:
The training and diligence of the men and women who operate it;
The system of which it is a part.
MT 5500
User Manual
© 2006 GARRETT METAL DETECTORS 36 PN 1530200.F.0506
11 ADDITIONAL INFORMATION
11.1 OPERATIONS WORK SHEET
Location: ____________________
Serial Number: ____________________
Version: ____________________
Date Seq. Number Prog Sens Changes Made Initials
___________ _______ _____ _____ ________________________ ____
___________ _______ _____ _____ ________________________ ____
___________ _______ _____ _____ ________________________ ____
___________ _______ _____ _____ ________________________ ____
___________ _______ _____ _____ ________________________ ____
___________ _______ _____ _____ ________________________ ____
___________ _______ _____ _____ ________________________ ____
___________ _______ _____ _____ ________________________ ____
___________ _______ _____ _____ ________________________ ____
___________ _______ _____ _____ ________________________ ____
___________ _______ _____ _____ ________________________ ____
___________ _______ _____ _____ ________________________ ____
___________ _______ _____ _____ ________________________ ____
___________ _______ _____ _____ ________________________ ____
___________ _______ _____ _____ ________________________ ____
___________ _______ _____ _____ ________________________ ____
MT 5500
User Manual
©2006 GARRETT METAL DETECTORS 37 PN 1530200.F.0506
11.2 PROGRAMS Note: Although different settings are required for different applications, the manufacturer finds Program D most effective for high volume high security; Program A for low volume maximum security; and Program 9 in loss prevention situations and in cases where noise problems limit performance of custom programs. It is the responsibility of the user to select and implement that program which is best suited to a particular situation.
11.2.1 PROGRAMS 1-10
Standard programs designed to detect a broad range of objects.
Lower numbered programs are primarily for the detection of ferrous objects such as iron, most
stainless steel, etc.
High numbered programs are primarily for the detection of conductive objects such as those
made of aluminum, zinc, lead, etc.
Programs 7-9 provide a balanced response to ferrous and conductive objects.
Program 9 provides good discrimination against foils (cigarette packs, etc.).
Immunity to external noise is good, making these programs useful in noisy environments.
Overall discrimination is poor.
Recommended applications include loss prevention and installations where specific objects
need to be emphasized or ignored.
11.2.2 PROGRAMS 11-15
Standard programs designed to detect a broad range of objects.
Lower numbered programs are primarily for the detection of ferrous objects such as iron, most
stainless steel, etc.
Higher numbered programs are primarily for the detection of large conductive objects such as
those made of aluminum, zinc, lead, etc.
Programs 14 and 15 provide a balanced response to ferrous and conductive objects.
Immunity to external noise is poor, making these programs difficult to use in noisy environ-
ments.
Overall discrimination is moderate.
Recommended applications include loss prevention and installations where specific objects
need to be emphasized or ignored.
11.2.3 PROGRAM A
Custom program designed to detect the broadest range of objects.
Emphasis of detection is on conductive objects. This program provides the highest level of
security available in the MT 5500.
Immunity to external noise is moderate, making this program usable in most environments.
Discrimination is poor.
Recommended applications include prisons and other installations where volume require-
ments allow thorough inspection of each individual.
11.2.4 PROGRAM B
Custom program designed to detect ferrous and conductive objects equally.
Immunity to external noise is moderate, making this program usable in most environments.
Discrimination is moderate.
Recommended applications include general security.
11.2.5 PROGRAM C
Custom program designed to detect ferrous and conductive objects equally.
This program is optimized for the three-gun test of the Federal Aviation Administration (FAA).
MT 5500
User Manual
© 2006 GARRETT METAL DETECTORS 38 PN 1530200.F.0506
Immunity to external noise is moderate, making this program usable in most environments.
Discrimination is good, providing the highest throughput rate.
Recommended applications include airports, schools, courtrooms and other high volume installations.
11.2.6 PROGRAM D
Custom program designed to detect ferrous and conductive objects.
Emphasis of detection is on conductive objects; this program provides a level of security that exceeds FAA requirements.
Discrimination is moderate to good; prevents detection signals from two or more targets from canceling each other (masking).
Recommended applications include airports, special events, private businesses, government buildings, schools, courtrooms and other installations requiring the maximum possible security in high volume operation.
11.2.7 PROGRAM E
Custom program designed to detect ferrous and conductive objects.
Emphasis of detection is on conductive objects.
Immunity to external noise is moderate, making this program viable in most environments.
Discrimination is moderate to good.
Recommended applications include loss prevention.
11.2.8 RECOMMENDED PROGRAMS
NOTE: These are only recommended programs. It is the End User’s responsibility to test and verify that
the selected program meets their security plan objective.
MT 5500
User Manual
©2006 GARRETT METAL DETECTORS 39 PN 1530200.F.0506
When to Use Applications Program Metal Types Discrimination
High volume traffic
Airports, special
events, private busi-
nesses, gov’t buildings,
schools, courthouses,
hospitals, corporate
security
D
Detects FAA test guns, plus the multi-composi­tion subject to masking
alloy types, iron, alu-
minum, steel
Good to excellent pre-
vents masking
designed to ignore
common pocket items
(High throughput)
When maximum
throughput is required
Airports C
Specially tuned to
detect FAA 3 guns,
stainless steel, iron,
aluminum
Excellent - designed to ignore common pocket
items.
(High throughout)
Maximum security
screening
Correctional Facilities,
Loss prevention, law
enforcement
A
All metal, ferrous, non-
ferrous
None
(Low throughput)
Alternative when A, C, D cannot be used due
to extreme environ-
mental conditions
All applications 9
FAA 3 gun, ferrous,
non-ferrous
Mild
Low Throughput
11.3 MULTIPLE UNIT OPERATION
There are several options for installation of multiple units in close proximity. The following list of examples will be helpful in determining an appropriate method of connection.
For proper operation, each walk-through metal detector must be set to receive no interference from adjoining units. This can be determined by observing the bar graph indication of one unit while switching the remaining unit(s) from OFF to OPERATE. If the noise flicker increases on the BAR GRAPH of a unit, then it may be necessary to select another set-up.
11.3.1 CASE I Description:
Two (2) or more units which interfere with each other;
Both units plugged into same power line (same circuit breaker).
Procedure:
Set all units to MASTER ;
Set end unit to CHANNEL 1 ;
Set next unit to CHANNEL 2;
Repeat pattern of CHANNELS 1,2 and 3 for any additional units.
11.3.2 CASE II: Description:
Two (2) or more units that interfere with each other;
Units not plugged into the same power line or units with battery back-up option which may be
required to operate in the absence of AC power.
Procedure:
Disconnect units from power line
Open Access Door of Detection Unit
Remove three (3) screws thqat hold controller cover;
Use synchronization wire (18 to 24-gauge, 2 conductor) between units; connect as shown:
Set the end unit to MASTER CHANNEL 1 and make sure this unit is connected to either AC
power or battery power at all times;
With the exception of the first and last units, the SH-3 jumper must be removed. This jumper is
located on the Controller Board Assembly (See illustration for exact location);
Replace covers and reconnect power;
Set all other units to SLAVE;
Set the remaining units to CHANNEL 2 and 3;
Repeat pattern of CHANNELS 1, 2 and 3 for any additional units.
MT 5500
User Manual
© 2006 GARRETT METAL DETECTORS 40 PN 1530200.F.0506
11.3.3 CASE III: Description:
MT 5500 unit(s) which interfere with CS 5000 unit(s).
Channels A, B, C and D allow the MT 5500 to operate with the CS 5000.
Procedure:
Use CHANNELS A, B, C and D;
Refer to CS 5000 manual for proper channel selection and connection.
11.4 AC & DC CONTROL
11.4.1 AC CONTROL
Connection of an external alarm, locking device or other component may be made as shown below. The optically-isolated triac output will conduct only during the time that the Red ALARM light is illuminated. It is recommended that the control not exceed 48Vrms and 100mA. The output is electrically isolated from ground.
Procedure:
Disconnect from AC power;
Open the Access Door of the detection unit;
Remove the three (3) screws that hold the controller cover;
Connect the relay or device to control;
Replace cover and reconnect power.
11.4.2 DC CONTROL
The three drawings that follow illustrate alternate methods of connecting an external device which has requirements of low voltage direct current. The output is an open collector configuration capa­ble of switching 15V at 100mA or less, which includes connections to computing devices and other equipment requiring low level DC.
MT 5500
User Manual
©2006 GARRETT METAL DETECTORS 41 PN 1530200.F.0506
11.4.2.1 Case I: Use internal power
Disconnect from AC power;
Open Access Door of detection unit;
Remove three (3) screws that hold controller cover;
Connect the relay or device to control, as shown at right;
Replace cover and reconnect power.
11.4.2.2 Case II: Use external power
Disconnect from AC power;
Open Access Door of detection unit;
Remove three (3) screws that hold controller cover;
Connect the relay or device to control,
• Replace cover and reconnect power.
11.4.2.3 Case III: External logic control
Disconnect from AC power;
Open Access Door of detection unit;
Remove three (3) screws that hold controller cover;
Connect the relay or device to control, as shown at right.
Replace cover and reconnect power.
11.5 REMOTE CONTROL (OPTIONAL)
A complete remote console with all control functions that are available on the overhead panel is available for monitoring and controlling functions of the Magnascanner MT 5500 from a location apart from the archway.
This remote console is connected to the overhead unit with telephone-type cable and RJ 45 connectors which can be easily concealed behind overhead panels or in 1/2-inch conduit. The remote control receives its power from the main detector unit.
Pressing a touchpad on the remote console achieves the same result as pressing the same touchpad on the overhead panel, except for the VOLUME and TONE adjustment.
Regulating alarm volume and tone must be done separately at the remote console and at each unit it controls. This enables the audio to be set separately at the required levels for the console and archway. A 50-foot cable is standard, but custom lengths are available.
MT 5500
User Manual
© 2006 GARRETT METAL DETECTORS 42 PN 1530200.F.0506
11.5.1 INSTALLATION
• With power disconnected locate archway and console in their desired locations;
Locate connecting wire and protect from tampering or vandalism, as necessary;
Plug the wire into the rear of the console;
Open the Access Door of the detection unit;
Remove three (3) screws that hold the controller cover;
• Plug the wire into the Circuit Board connector as shown on Page 27;
Replace covers and connect to power.
11.6 BATTERY BACK-UP MODULE (OPTIONAL)
This optional module is a field-installable assembly that provides power to operate the MT 5500 for up to twenty (20) hours on a fully charged battery. System software includes an alarm feature that alerts the operator to a low-battery condition. This ensures that the unit continues to operate at its peak performance level.
This module includes two 12v batteries and charging circuitry that comprise the Optional Battery Pack. This module has a battery-monitoring circuit which will charge the battery within 12 hours and will switch to trickle-charge to maintain a fully charged condition without damaging the batter­ies.
11.6.1 INSTALLATION
1. Open the access door of the detection unit;
2. Disconnect the AC power plug from the Power Supply Module;
3. Remove the three (3) screws that hold the Controller Module Cover;
4. Remove the four (4) acorn nuts that are attached to the Battery Pack Module mounting studs;
5. Install the Battery Pack Module and replace the acorn nuts;
6. Disconnect the Power Supply Module connector on the upper left of the Controller Circuit Board;
MT 5500
User Manual
©2006 GARRETT METAL DETECTORS 43 PN 1530200.F.0506
7. Reconnect the Power Supply Module and Battery Pack Module as shown;
8. Reassemble the system and test.
11.7 STABILIZER BASE INSTALLATION
TOOLS REQUIRED PARTS LIST
•1/4” Electric Drill Motor •2-Mounting Plate
•1/4” (6mm) Nut Driver or Hex Socket •4-Screw #8x2” Self-Tapping 1/4”
•Tape Measure •1-Drill Bit 3/32”
•Liquid Soap •1-Instruction Sheet
•#2 Phillips Screwdriver
Procedure (NOTE: Install mounting plates before
assembling the archway)
11.7.1 Examine the location and determine the best routing for the power cord.
11.7.2 For each panel, remove and discard the two (2) rubber bumpers located on the bottom of the pan-
els. these holes will be used for attaching mounting plates to panels. These holes will be sued for attaching mounting plates to panel.s. Discard rubber bumpers and screws.
11.7.3 Using the supplied 3/32” (2.3mm) drill bit, extend the depth of the mounting holes to 2” (50mm) deep.
11.7.4 Attach the plates (with the edges pointing away from the panel) using the supplied 2” long screws.
NOTE:
A small amount of liquid soap will make the installation easier.
CAUTION:
The power cord must be installed in the correct Panel location (see section 3.2) before the plate
can be secured. DO NOT PINCH the cord between the panel and the plate. Ensure that the head of
the screw is tight against the plate to prevent the panels from sliding.
11.7.5 Assemble the unit.
MT 5500
User Manual
© 2006 GARRETT METAL DETECTORS 44 PN 1530200.F.0506
11.7.6 Place unit in upright position at selected operating location.
CAUTION:
Adjust the width of the unit at the bottom of the panels to 30” (762mm) BEFORE making the holes
in the next step.
11.7.7 Secure the unit to the floor using 1/4” (6mm) mounting screws (not supplied). The mounting holes in
the plates may be used as a drill guide.
11.8 ELECTRICAL WIRING REQUIREMENTS
Magnascanner MT 5500 # 1167700
Comes with a standard American ground power cord. If the plug must be replaced or removed to hard wire an AC junction box, use the following wiring list:
Green To Ground Black To Line Hot White To Line Neutral
Magnascanner CS 5000 # 1167420 (International)
Comes with a European power cord. If the plug must be replaced or removed to hardwire to an AC junction box, use the following wiring list:
Green/Yellow To Ground Brown To Line Hot Blue To Line Neutral
MT 5500
User Manual
©2006 GARRETT METAL DETECTORS 45 PN 1530200.F.0506
MT 5500
User Manual
© 2006 GARRETT METAL DETECTORS 46 PN 1530200.F.0506
©2006 GARRETT METAL DETECTORS - The Global Leader of Metal Detection Products and Training - 1530200.F