HIPAA
1-800-624-1903
4075-244P Manual, Operator HD-3WXL
4-10-2018
US
HD-3WXL SERIES Operation Manual
IMPORTANT SAFETY NOTES
No operator-serviceable parts inside unit. Maintenance to be done only by trained personnel.
High Voltage exists inside unit even when equipment is not under power. All trouble shooting and wiring checks must be performed by a qualified electrician or authorized plant personnel.
Unplug power cord from the wall to disconnect power to the system.
Disconnect main power and unplug unit from the wall before installing or removing device or servicing equipment.
PACE MAKER USERS
Due to stray magnetic fields, consult your physician before operating.
A non-shielded power cord may be used to connect AC power to the system. Use only power cords approved by Garner Products.
For continued protection against risk of fire, replace fuses with fuses of same types and ratings only.
Airflow is important. Do not cover chassis ventilation slots or block enclosure openings.
Check input voltage selection; if not compatible with wall voltage, have technician qualified by Garner Products modify wiring inside this system before connecting system plug to wall voltage.
CONTROLS AND INDICATORS
POWER Button (RED) The power button switches the power on and off.
LCD display The LCD display gives status, automatic count, total count, software version, field
strength, user instructions and fault messages.
Media Entrance Door The HD-3WXL media degausser operates automatically when media is
inserted into the media entrance door.
LCD DISPLAY DEGAUSSING INSTRUCTIONS
The following information appears on the LCD Display from power-up through one automatic degaussing cycle:
GARNER
PRODUCTS, INC.
Automatic Degaussing
Step 1: Press POWER button ON
Displays manufacturer.
Displays degausser model.
INITIATION
Introduction
The Garner HD-3WXL degausser is a conti nuous duty capacitive discharge degausser. The unit is designed to erase hard drives and tape cartridges that fit within the opening of the Media Entrance Door. The convenient media loading design accommodates many different types and sizes of media, without the need for adapters.
Each erase cycle is measured and verified by internal diagnostics thus eliminating the possibil ity of a non­erasure. For security purposes, if an insufficient field is detected, the HD-3WXL will not release the media.
Inspection
Inspect the degausser for shipping damage as soon as it is unpacked. If the degausser or any accessories are damaged or fail to operate correctly, notify carrier and contact your dealer immediately
INSTALLATION
Power Plug
Plug the IEC connector attached to the supplied power cord into the receptacle on the back of the unit.
Location
The degausser must be placed on a flat, hard surface. Keep at least a 15 cm (6 inch) distance from any object that may interfere with the coo ling fan exhaust located on the backside of the degausser. As a general rule, media not inten ding to be erased should be kept about 60 cm (2 ft) away.
Cooling
Forced air-cooling is used to maintain safe ope rating temperatures within the degausser. The air intake is located on the back panel and the exhaust is through the holes in the top panel. To ensure proper cooling, do not block the air-intake and maintain at least a 15 cm (6 in.) distance from the back of the degausser to any obstacle.
FIRMWARE VER
##
TOTAL
# −− ##
Insert Media
Session = 0
Erase Cycle
Initiated
Charging
>>>>>>>>>>>>>>>>
--------------===|==
Data Eliminated
Displays current firmware version.
Displays total erasing cycles. Number on left indicates number of times the counter reached 50,000.
Ready for media to be placed in the media entrance door. Counter for erase cycles completed since power up.
Indicates media entrance door is open – this is normal when inserting media to be erased.
Step 2: Insert media
Door has closed and the erase cycle has started.
Displays capacitor charging status.
Visual indicator of erasing field strength.
Indicates power and erasing field strength was verified good and data has been eliminated.
Step 3: Remove Media
Media gate has lowered and erased media will slide out.
DEGAUSSING INSTRUCTIONS FOR DLT MEDIA
Remove the plastic protective cases.
Although the data is completely degaussed in one operation, a second pass rotated at 90 degrees is required to smooth out any magnetic fluctuation.
Note: If the second pass is not completed, the tape drive may eject the tape from the tape drive and indicate that the tape needs cleaning. The second pass at 90 degrees will correct this condition. If you have any questions, please contact your dealer.
First Pass
Second Pass
1 of 5
US
LCD DISPLAY ERROR CODES
Charge Error
The LCD displays “Charge Error”. This error indicates that the degausser failed to charge to the determined power level necessary to successfully erase the media in the degaussing chamber.
Note: The media will stay in the degaussing chamber until a successful erase sequence has been completed.
Action: Turn off the degausser for one minute and restart. (Turning off the power to the degausser will clear the error.) To initiate the degauss cycle with media already in the degaussing chamber, push the Media Entrance Door open and let it close. The media in the degaussing chamber will be erased and only released with a successful degauss. If the error repeats, have the power mains checked and also check the degausser to make sure the power setting is set to match the power mains. If error persists, call customer support.
Gauss Error
The LCD displays “Gauss Error”. This error indicates the erasing field may not have been adequate to effectively erase the media in the degaussing chamber. Media will not be ejected.
Action: Turn off the degausser for approximately one minute. Turning off the power to the degausser will clear the error. Turn the degausser back on. To initiate the degauss cycle with media already in the degaussing chamber, push the Media Entrance Door open and let it close. The media in the degaussing chamber will be erased and only released with a successful degauss. If error persists, call customer support.
HD-3WXL SERIES Operation Manual
Door Open Error
The LCD displays “Door Open”. This error indicates that the Media Entrance Door is not completely closed. The degausser checks to see if the Media Entrance Door is closed just before the media is to be erased.
Once the door is closed, the degausser will automatically continue the erase function.
Action: Check Media Entrance Door for obstructions.
Overheat Error
The LCD displays “Overheat”. This error indicates the internal temperature has risen to a level that may be harmful to the degausser.
Action: When the degausser indicates an overheat error, it will inhibit any further operation until the degausser returns to an acceptable temperature. Leave the degausser powered on as the chassis fan will help reduce the heat inside the degausser. When the temperature is low enough, the degausser will return to normal operation. If this error persists, call customer support.
EJECTING MEDIA AFTER AN ERROR
To retrieve media that has remained in the degaussing chamber due to an error:
Step 1: Press the POWER button to the off (|) position.
Step 2: Press the POWER button to the on (0) position.
Step 3: Manually open the door of the degaussing chamber.
Step 4: The HD-3WXL will complete a degauss cycle and release the media.
Step 5: If the media does not release, call Garner for technical support.
DISPOSAL
Disposing of the machine:
Dispose of the machine in an environmentally sound fashion at the end of its useful service life. Do not dispose of any of the parts included in the machine or its packaging with household trash.
SPECIFICATIONS
Part Numbers HD-3WXL Certifications/Listings CE • ANSI • FCC Power Supply 100~240VAC ±5%, 50/60 Hz- Factory configurable Power Consumption During standby: 36W
During charge: 300W (avg) At the time of erase: 36W
Media Hard drives and tapes up to 1.7 in. in height Throughput Up to 3600 (1.8 in.) hard drives per hour
Up to 1440 (2.5 in.) hard drives per hour
Up to 360 (3.5 in.) hard drives per hour Cycle Time 10 seconds per cycle Erasure Verification SCAN-1: Standard
IRONCLAD: Optional upgrade Degausser System Capacitive Discharge Operating Duty Cycle Continuous Magnetic Field 9,300 Gauss / .93 Tesla Slot Capacity 1.7 x 4.5 x 5.9 (in.) 43.2 x 114.3 x 148.6 (mm) Temperature 5°C - 40°C (41°F - 104°F) Humidity 10%H - 40%H (without condensation) Weight 66 lbs. (30 kg) Dimensions(HxWxD) 18.9 x 13.33 x 13 in. (480.06 x 338.58 x 328.9 mm)
with slide: 22.76 in. (578.1 mm) width Warranty 1 Year Factory Warranty Standard, Optional 3 Year Factory
Warranty available. Made In the U.S.A. By Garner Products, Inc.
2 of 5
HD-3WXL SERIES Operation Manual
3 of 5
HD-3WXL SERIES Operation Manual
GARNER PRODUCTS, INC. LIMITED WARRANTY
AND
WARRANTY RETURN POLICY
Garner Products, Inc. (“Garner”) warrants this Garner-branded product (“Product”) against defects in materials and workmanship for
a period of ONE (1) YEAR from the date of purchase by the original end-user (“end-user”) as evidenced by end-user’s packing slip or invoice (“Warranty Period”). No Product may be returned except upon prior written permission by Garner and shipment to factory with transportation charges prepaid.
If a valid claim is received within the Warranty Period, at its option, Garner will either: (1) repair the Product, (2) exchange the Product, or (3) request that end-user replace parts with new or refurbished user-installable parts that Garner provides in fulfillment of its warranty obligations. A replacement Product or Part, including a user-installable part that has been installed in accordance with instructions provided by Garner, assumes the remaining warranty of the original Product.
Garner is not responsible for damage arising from failure to follow instruction relating to the Product’s use. This warranty does not apply to: (a) cosmetic damage, including but not limited to scratches, dents and broken plastic; (b) freight damage; (c) consumable parts; (d) normal wear and tear or otherwise due to the normal aging of the Product; (e) damage caused by accident, abuse, inadequate wiring, power surge, rust, corrosion, neglect, misuse, liquid contact, fire, earthquake or other external causes; (f) damage caused by operating the Product outside the permitted or intended uses described by Garner; (g) damage caused by service performed by anyone who is not a representative of Garner or a Garner authorized service provider; (h) a Product or part that has been modified to alter functionality or capability without the written permission of Garner; or (i) if any Garner serial number has been removed or defaced.
No Garner dealer or reseller is authorized to make any modification, extension, or addition to this warranty.
DISCLAIMER
TO THE EXTENT PERMITTED BY LAW, THIS WARRANTY AND THE REMEDIES SET FORTH ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, REMEDIES AND CONDITIONS, WHETHER ORAL, WRITTEN, STATUTORY, EXPRESS OR IMPLIED. GARNER DISCLAIMS ALL STATUTORY AND IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND WARRANTIES AGAINST HIDDEN OR LATENT DEFECTS, TO THE EXTENT PERMITTED BY LAW. IN SO FAR AS SUCH WARRANTIES CANNOT BE DISCLAIMED, GARNER LIMITS THE DURATION AND REMEDIES OF SUCH WARRANTIES TO THE DURATION OF THE EXPRESS WARRANTY AND RETURN POLICY DESCRIBED HEREIN.
LIMITATION OF LIABILITY
EXCEPT AS PROVIDED IN THIS WARRANTY AND TO THE MAXIMUM EXTENT PERMITTED BY LAW, IN NO EVENT SHALL GARNER BE LIABLE TO ANY PARTY FOR ANY DIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM ANY BREACH OF WARRANTY OR CONDITION, OR UNDER ANY OTHER LEGAL THEORY, INCLUDING BUT NOT LIMITED TO LOSS OF USE; LOSS OF REVENUE; LOSS OF ACTUAL OR ANTICIPATED PROFITS; LOSS OF BUSINESS; LOSS OF GOODWILL; LOSS OF, DAMAGE TO, COMPROMISE OR CORRUPTION OF DATA; OR ANY INDIRECT OR CONSEQUENTIAL LOSS OR DAMAGE HOWSOEVER CAUSED. END-USER’S SOLE AND EXCLUSIVE REMEDY FOR ANY CAUSE OF ACTION, IS A CLAIM FOR DAMAGES WHICH IN NO EVENT WILL EXCEED THE PRICE OF THE SPECIFIC PRODUCT AS TO WHICH THE CLAIM IS MADE.
If a problem occurs with this Product, contact Garner directly by Email at Info@Garner-Products.com or by phone at (916) 784-0200 to obtain technical support and/or to get a Return Authorization Number (RA#).
All returns must be specifically authorized by Garner prior to shipment and returned to Garner FREIGHT PREPAID with the RA# marked prominently near the shipping label.
Garner recommends using the original shipping container to securely package the Product. It is end-user’s responsibility to ensure the Product is packaged properly to prevent damage during transit to Garner. Garner will provide product packaging to end-user at end­user’s request and expense.
Enclose proper documentation, including RA#, the return address, a name and phone number of the contact person, the serial number of the merchandise being returned and a description of the reason for the return. Omission of any of this information may delay service. Garner recommends end-user insure the shipment; otherwise end-user accepts the risk if Product is lost or damaged in shipment.
Garner will pay to ship the repaired or replacement Product to end-user’s shipping dock if end-user’s delivery address is in the United States (excluding Puerto Rico and U.S. possessions and territories); otherwise Garner will ship the Product to end-user freight collect. Garner will select method for return shipment. Alternate shipment methods may be made at end-user’s expense.
WARRANTY RETURN POLICY
4 of 5
Company:
Garner Products Inc.
10620 Industrial Avenue, Suite 100 Roseville, CA 95678 USA Tel: (800) 624-1903 or (916) 784-0200 Fax: (916) 784-1425Hours: Monday through Friday,
8:00 a.m. to 5:00 p.m. Pacic Time (GMT - 8 hours)
Email: info@garner-products.com
Distributors:
Datumstruct (s) Pte Ltd, Singapore
33 Changi South Ave 2, #03-00 Singapore 486445 Tel: (65) 6749 0206 Fax: (65) 6742 2827 Hours: Monday through Friday, 9:00 a.m. to 6:00 p.m. Singapore Standard Time (GMT + 8 hours)Email: Email: datumstruct@garner-products.com
Datalifecycle.com Pvt Ltd, India
No 55, 17th Cross Road, between 6th and 8th Main, Malleshwaram, Bangalore – 560 055, India. Tel: (91) 80 2344 4490 Hours: Monday through Friday, 9:00 a.m. to 6:00 p.m. India Standard Time (GMT + 5:30 hours) Email: datalifecycle@garner-products.com
HD-3WXL SERIES Operation Manual
Synnex Canada Limited, Canada
200 Ronson Drive Toronto, Ontario Canada M9W 5Z9 Contact: Lucy Sousa Tel: +1 (416) 240-2531 Hours: Monday through Friday, 9 a.m. to 6 p.m. Canada Standard Time (GMT – 4 hours) Email: synnex@garner-products.com
Varese Secure Ltd, United Kingdom
Lancaster Court 8 Barnes Wallis Road Fareham PO15 5TU Tel: +44(0) 1489 660196 Mobile: +44(0) 7740 725647 Hours: Monday through Friday, 9:00 a.m. to 5:00 p.m. Greenwich Mean Time (GMT) Email: varese-secure@garner-products.com
Stocking U.S. Dealer:
Data Devices International, Inc., USA
14431 Ventura Blvd., #434 Sherman Oaks, CA 91423 Tel: (626) 799-6545 Email: datadev@garner-products.com
Better Shredders 35 Trevor Road York, PA 17404 Tel: (717) 829-1894 Toll Free: (888) 350-2079 Email: bettershredders@garner-products.com
5 of 5
Loading...