RISER-WRAP®
Water Infiltration Sealing System

RISER-WRAP®
The Riser-Wrap® seal is a two-layer system designed
for corrosion and sealing protection on pipelines and
encapsulating manholes to seal joints against ground water
infiltration.
The first layer is a visco-elastic adhesive liquid sealant
covered by a heat shrink sleeve. The heat shrink is a thickwalled .098” (2.5mm),cross-linked, high density polyethylene
membrane.
APPLICATIONS
» Manhole Encapsulation/
Sealing
» Pipelines
» Step-down Joints
» Square/Rectangular Vaults
» Septic Tanks/Vaults
» Repair and Rehabilitation
RISERWRAP® SQUARE VAULT APPLICATION
FEATURES AND BENEFITS
Low Preheat Requirements
» Preheat required only to remove the moisture from the
surface and for fast/easy installation
Offers Permanent Heat Change Indicators
» Permanent Heat Indicator ensures that the correct
application of heat has been applied to the entire heat
shrink sleeve
» Installation is fully inspectable at any time after the
installation
High Modulus of Elasticity Backing
» Accommodates ground movement.
High Impact and Penetration Resistance
» Toughness to resist soil stress
High Shrink Force
» Optimizes flow and fill of visco-elastic adhesive sealant
» Seals against ground water infiltration
Impermeable
» Provides corrosion protection
» Extends structure life
No Special Tools
» Quick & easy installation
Sizing Calculation Program
» On-line at www.gptindustries.com
PROPERTIES
ASTM Test Test Results
ADHESIVE
Softening Point ASTM E-28
Lap Shear ASTM D-1002 12N/cm
BACKING
Tensile Strength ASTM D-638 22mPa 3,300psi
Elongation ASTM D-638 650%
Hardness, Shore D ASTM D-224 58 Shore D
Shrink Force ASTM D-638 26N/cm
Dielectric Strength ASTM D-149 20KV/mm 500KV/in.
SLEEVE
Peel Strength ASTM D-1000 20/N/cm 11lb/in.
Water Absorption ASTM D-570 0.05%
Low Temp. Flexibility ASTM D-2671
Penetration Resistance ASTM G-17 Pass
205°C 400°F
2
18psi
2
38psi
-40°C -40°F
TYPICAL SPECIFICATIONS
1.0 Scope
Apply RISERWRAP® heat shrinkable sleeve on exterior
concrete manholes or other structures at locations
indicated by the Engineer to protect manhole and reduce
infiltration or ingress of water and other contaminates.
The sleeve needs be applied over a cleaned, primed
surface.
2.0 Sleeve - High Density Polyethylene Membrane
The heat shrinkable sleeve consists of an 11” or 17”
wide wrap-around, 2.5mm thick, cross-linked high density
polyethylene membrane complete with a mastic. Peel
Strength is a minimum of 11 lb./in. per ASTM D 1000.
Tensile Strength is 3,300 psi minimum per ASTM D-638.
Mastic softening point should meet or exceed 400°F
in accordance with ASTM E-28. Sleeve will incorporate
permanent heat indicators, to assure proper heating.
3.0 Joiner-Strip
The material to close the sleeve consists of a high
density polyethylene fiber reinforced material to assure
sleeve pulls tight. Lap Shear on assembled system will
exceed 18psi per ASTM D-1002.
4.0 Primer
Primer is a Polyken 1027 or 1039. Primer needs be black
in color and applied at a rate of approximately 2 – 3 mills.
Must be able to dry with-in one hour.
RISERWRAP® VACUUM TEST