Garland X36-2G24R, SX-4-20 Installation Manual

INSTALLATION AND
OPERATION MANUAL
SUNFIRE SX SERIES GAS
RESTAURANT RANGES
FOR YOUR SAFETY:
DO NOT STORE OR USE GASOLINE
OR OTHER FLAMMABLE VAPORS OR
LIQUIDS IN THE VICINITY OF
THIS OR ANY OTHER
APPLIANCE
WARNING:
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE, INJURY,
OR DEATH. READ THE INSTALLATION,
OPERATING AND MAINTENANCE
INSTRUCTIONS THOROUGHLY
BEFORE INSTALLING OR
SERVICING THIS EQUIPMENT
AND RETAIN FOR FUTURE REFERENCE.
THIS PRODUCT HAS BEEN CERTIFIED AS COMMERCIAL COOKING EQUIPMENT AND MUST BE INSTALLED BY PROFESSIONAL
PERSONNEL AS SPECIFIED.
IN THE COMMONWEALTH OF MASSACHUSETTS
THIS PRODUCT MUST BE INSTALLED BY A
LICENSED PLUMBER OR GAS FITTER. APPROVAL NUMBER: G-1-07-05-28
For Your Safety: Post in a prominent location, instructions to be followed in the event the user smells gas. This information shall be obtained by consulting
your local gas supplier.
Users are cautioned that maintenance and repairs must be performed by a Garland authorized service agent
using genuine Garland replacement parts. Garland will have no obligation with respect to any product that has been
improperly installed, adjusted, operated or not maintained in accordance with national and local codes or installation
instructions provided with the product, or any product that has its serial number defaced, obliterated or removed,
or which has been modified or repaired using unauthorized parts or by unauthorized service agents.
For a list of authorized service agents, please refer to the Garland web site at http://www.garland-group.com.
The information contained herein, (including design and parts specifications), may be superseded and is subject
PLEASE READ ALL SECTIONS OF THIS MANUAL
GARLAND COMMERCIAL INDUSTRIES
185 East South Street Freeland, Pennsylvania 18224 Phone: (570) 636-1000 Fax: (570) 636-3903
Part # 4515146 (02/29/08) © 2005 Garland Commercial Industries, Inc.
Part # 4515146 (02/29/08) Page 1
GARLAND COMMERCIAL RANGES, LTD.
1177 Kamato Road, Mississauga, Ontario L4W 1X4 CANADA Phone: 905-624-0260 Fax: 905-624-5669
Enodis UK LTD.
Swallow eld Way, Hayes, Middlesex UB3 1DQ ENGLAND Telephone: 081-561-0433 Fax: 081-848-0041
IMPORTANT INFORMATION
WARNING: This product contains chemicals known to the state of California to cause cancer and/or birth defects or other reproductive harm. Installation and servicing of this product could expose you to airborne particles of glass wool/ceramic fibers. Inhalation of airborne particles of glass wool/ceramic fibers is known to the state of California to cause cancer. Operation of this product could expose you to carbon monoxide if not adjusted properly. Inhalation of carbon monoxide is known to the state of California to cause birth defects or other reproductive harm.
Keep appliance area free and clear of combustibles.
Part # 4515146 (02/29/08)Page 2
Part # 4515146 (02/29/08) Page 3
TABLE OF CONTENTS
IMPORTANT INFORMATION.............2
DIMENSIONS AND SPECIFICATIONS.....4
Gas Pressures................................4
Individual Burner Input Rates.................4
Models Designations.........................4
Dimensions..................................5
INTRODUCTION........................5
INSTALLATION.........................6
Siting........................................6
Appliances Equipped with Casters ............6
Appliances Equipped with legs ...............6
Installing Shelf to Backguard .................6
Installing a Backguard or Shelf................7
Ventilation Air ...............................7
OPERATION............................9
Open Top burners ...........................9
Hot top Sections.............................9
Valve Controlled Griddles ....................9
Raised Broiler/Griddles.......................9
General.....................................10
Standard Ovens.............................10
Open Burners...............................11
Hot tops....................................11
Griddles....................................11
MAINTENANCE AND CLEANING........12
Stainless Steel ..............................12
Interior Cleaning of Standard Aluminized
Steel Interior Surfaces.......................12
Open Top Burners ..........................12
Statutory Regulations........................7
Gas Connection..............................7
Installation Notes:............................8
TESTING & ADJUSTMENT...............8
Testing......................................8
Griddle Seasoning ...........................9
Cast Iron Top & Ring Grates..................13
Griddle.....................................13
Hot Tops....................................13
DIMENSIONS AND SPECIFICATIONS
Gas Pressures
GAS MINIMUM SUPPLY GAS PRESSURE MANIFOLD OPERATING PRESSURE
Natural 7” WC 17.5 mbar 4.5” WC 11.25 mbar
Propane 11” WC 27.5 mbar 10.0”WC 25 mbar
Individual Burner Input Rates
BURNER
Open Burner 28,000 #39 28,000 1.5 mm
Hot Top, 20,000 #45 20,000 #54
12” Griddle, 20,000 #45 20,000 #54
Broiler/Griddle 14,000 #52 13,500 #57
26” Oven Burner Standard or RC 30,000 #36 30,000 #51
20” Oven Burner 25,000 #40 25,000 #54
INPUT
BTU/HR
NATURAL GAS PROPANE GAS
ORIFICE
SIZE DMS
INPUT
BTU/HR
ORIFICE
SIZE DMS
Models Designations
MODEL NO. DESCRIPTION
SX-4 (4) Open Burners, Storage Base
SX-4-20 (4) Open Burners, (1) 20” Oven
SX-6 (6) Open Burners, Storage Base
SX-6-26 (6) Open Burners, (1) 26” Oven
SX-6-24BG-2626 (6) Open Burners, (1) 24” Raised Broiler/Griddle, (2) 26” Ovens
SX-6-24BG-26 (6) Open Burners, (1) 24” Raised Broiler/Griddle, (1) 26” Oven (1) Storage Base
SX-10-2626 (10) Open Burners, (2) 26” Ovens
SX-10-26 (10) Open Burners, (1) 26” Oven (1) Storage Base
SX-1HT-4 (4) Open Burners, (1) 12” Hot Top, (1) Storage Base
SX-1HT-4-26 (4) Open Burners, (1) 12” Hot Top, (1) 26” Oven
SX-24G-2 (2) Open Burners, (1) 24” Griddle, (1) Storage Base
SX-24G-2-26 (2) Open Burners, (1) 24” Griddle, (1) 26” Oven
SX-24G-6-26 (6) Open Burners (1) 24” Griddle, (1) 26” Oven, (1) Storage Base
SX-24G-6-2626 (6) Open Burners (1) 24” Griddle, (2) 26” Ovens
Part # 4515146 (02/29/08)Page 4
Part # 4515146 (02/29/08) Page 5
DIMENSIONS AND SPECIFICATIONS Continued
Dimensions
MODEL NO. WIDTH DEPTH
SX-4 24” (610mm) 33-1/8” (841mm) 38-1/2” (978mm) 32-1/2” (343mm) 275/125
SX-4-20 24” (610mm) 33-1/8” (841mm) 38-1/2” (978mm) 32-1/2” (343mm) 350/159
SX-6 36” (914mm) 33-1/8” (841mm) 38-1/2” (978mm) 32-1/2” (343mm) 346/157
SX-6-26 36” (914mm) 33-1/8” (841mm) 38-1/2” (978mm) 32-1/2” (343mm) 446/202
SX-6-24BG-2626 60” (1524mm) 33-1/8” (841mm) 38-1/2” (978mm) 32-1/2” (343mm) 855/387
SX-6-24BG-26 60” (1524mm) 33-1/8” (841mm) 38-1/2” (978mm) 32-1/2” (343mm) 736/333
SX-10-2626 60” (1524mm) 33-1/8” (841mm) 38-1/2” (978mm) 32-1/2” (343mm) 756/343
SX-10-26 60” (1524mm) 33-1/8” (841mm) 38-1/2” (978mm) 32-1/2” (343mm) 710/322
SX-1HT-4 36” (914mm) 33-1/8” (841mm) 38-1/2” (978mm) 32-1/2” (343mm) 360/163
SX-1HT-4-26 36” (914mm) 33-1/8” (841mm) 38-1/2” (978mm) 32-1/2” (343mm) 460/209
SX-24G-2 36” (914mm) 33-1/8” (841mm) 38-1/2” (978mm) 32-1/2” (343mm) 380/172
SX-24G-2-26 36” (914mm) 33-1/8” (841mm) 38-1/2” (978mm) 32-1/2” (343mm) 480/218
SX-24G-6-26 60” (1524mm) 33-1/8” (841mm) 38-1/2” (978mm) 32-1/2” (343mm) 719/326
SX-24G-6-2626 60” (1524mm) 33-1/8” (841mm) 38-1/2” (978mm) 32-1/2” (343mm) 793/326
W/ LEGS W/O LEGS
HEIGHT
WEIGHT
LBS/KG
INTRODUCTION
1. Check crate for possible damage sustained during transit. Carefully remove unit from crate and again check for damage. Any damage to the appliance must be reported to the carrier immediately.
2. The wires for retaining the burners and other packing material must be removed from units. Any protective material covering stainless steel parts must also be removed.
3. All equipment is shipped from the factory with legs tted, unless otherwise specied. Where the range is to be mounted on a dais or cove base, it is shipped without legs. Legs must be tted to the oven when it is installed on a combustible oor.
4. The type of gas and supply pressure that the equipment was set-up for at the factory is noted on the data plate and on the packaging. This type of gas supply must be used.
5. Do not remove permanently axed labels, warnings or data plates from the appliance, for this may invalidate the manufacturer’s warranty.
INSTALLATION
This product has been certied as commercial cooking equipment and must be installed by professional personal as specied. THIS APPLIANCE IS NOT RECOMMENDED FOR RESIDENTIAL INSTALLATION.
We suggest installation, maintenance and repairs should be preformed by your local Garland authorized service agency.
Siting
The oor on which the appliance is to be sited must be capable of adequately supporting the weight of the appliance and any ancillary equipment.
Units with ovens must be tted with legs if installed on a combustible oor.
Adequate clearance must be provided for servicing and proper operation.
Appliances Equipped with Casters
1. The installation shall be made with a connector that complies with the Standard for Connectors for Moveable Gas Appliances, ANSI Z21.69/CSA 6.16, Addenda Z21.69B­2006/CSA 6.16B-2006 (or latest edition), and a quick­disconnect device that complies with the Standard for Quick Disconnects for Use with Gas Fuel, ANSI Z21.41/ CSA 6.9, Addenda Z21.41A-2005/CSA 6.16A-2005 (or latest edition).
2. The front casters on the appliance are equipped with brakes to limit the movement of the appliance without placing any strain on the connector or quick disconnect device or its associated piping.
Appliances Equipped with legs
1. Raise the front of the appliance and block. Do not lay the appliance on its back.
2. Position a leg insert in leg retainer opening and tap upward until the insert seats at the collar ange.
3. Repeat leg insert installation for the other three legs and adjust all four legs to the same height.
4. Legs can be further adjusted to level the appliance and to compensate for uneven ooring.
Installing Shelf to Backguard
Note: Shelf may be installed before or after installing the backguard to the range.
1. Loosen 4 bolts on the front of the backguard approximately 1/4” (6mm).
2. Align the 4 holes on the back of the shelf with the 4 bolts on the backguard.
3. Slide the shelf downward until the 4 bolts are engaged in the slotted portion of the keyhole.
4. Tighten the 4 bolts to secure shelf.
5 On 60” units only, install a sheet metal screw though the
hole in the underside of the shelf into the backguard and tighten.
3. Please be aware; required restraint is attached to a bracket, (which is located on the rear of the caster closest to the gas connection), and if disconnection of the restraint is necessary, be sure to reconnect the device after the appliance has been returned to its original position.
MOUNTING
BOLTS
BACKGUARD
SHELF
SHEETMETAL SCREW
Part # 4515146 (02/29/08)Page 6
Part # 4515146 (02/29/08) Page 7
INSTALLATION Continued
Installing a Backguard or Shelf
1. Rear of range must be easily accessible.
2. Place the backguard, high shelf, salamander, or cheesmelter on the rear of the range, slipping the support brackets into the openings in the burner box sides.
3. Securely fasten the support brackets to the burner box sides with (4) #14 x 5/8” Hex washer head, type B tapping screws. (Hardware package is supplied)
Upright
Burner Box Side
#14 x 5/8" Type "B" Hex Head Tapping Screw 4 Req'd
All gas burners and pilots need sucient air to operate. Large objects should not be placed in front of the appliance(s) that would obstruct the ow of air into the front.
Statutory Regulations
The installation of this appliance must be carried out by a competent person and in accordance with the relevant regulations, codes of practice and the related publications of the country and destination.
The installation must conform to the National Fuel Gas Code ANSI Z223.1-1998 or latest edition, NPFA No.54 - latest edition/or local code to assure safe and ecient operation. In Canada, the installation must comply with CSA B149.1 and local codes.
Gas Connection
The local gas authority should be consulted at the installation planning stage in order to establish the availability of an adequate supply of gas and to ensure that the meter is adequate for the required ow rate. The pipe work from the meter to the appliances must be of an appropriate size.
All xed (non-mobile) appliances MUST be tted with a manual gas-cock upstream of the appliance to provide a means of isolation for servicing or cleaning purposes. A union or similar means of disconnection must be provided between the gas-cock and the appliance.
A manually operable valve must be tted to the gas supply to the kitchen to enable it to be isolated in an emergency.
Ventilation Air
The following notes are intended to give general guidance. For detailed recommendations, refer to the applicable code(s) in the country of destination.
Proper ventilation is highly essential for optimum performance. The ideal method of ventilating open-top equipment is the use of a properly designed canopy that should extend six inches (152mm), beyond all sides of the appliance(s) and six feet, six inches (1981mm) above the oor.
A strong exhaust will create a vacuum in the room. For an exhaust vent to work properly, replacement air must enter the room. The amount of air that enters must be equal to the amount exhausted.
Wherever practical, this shall be located either outside the kitchen or near to an exit in a readily accessible position.
Where it is not practical to do this, an automatic isolation valve system shall be tted which can be operated from a readily accessible position near to the exit.
At locations where the manual isolation valve is tted or the automatic system can be reset a notice MUST be tted stating:
“ALL DOWNSTREAM BURNER AND PILOT VALVES MUST BE TURNED OFF PRIOR TO ATTEMPTING TO RESTORE THE SUPPLY. AFTER EXTENDED SHUT OFF, PURGE BEFORE RESTORING GAS.”
INSTALLATION Continued
Installation Notes:
Before assembly and connection check gas supply.
A. The type of gas for which the unit is equipped is stamped
on the data plate located behind the lower front panel. Connect a unit stamped “NAT” only to natural gas; connect one stamped “PRO” only to propane gas.
B. If it is a new installation have the gas authorities check
meter size and piping to assure that the unit is supplied with necessary amount of gas pressure required to operate the unit.
C. If it is additional or replacement equipment have the gas
authorities check pressure to make certain that existing meter and piping will supply fuel to the unit with no more than 0.15 Kpa pressure drop.
TESTING & ADJUSTMENT
D. Make certain new piping and connections have been
made in a clean manner and have been purged so that piping compound, chips, etc. will not clog pilots, valves or burners. Use pipe joint compound approved for natural and liqueed petroleum gases.
NOTE: Gas pressure should be checked when the unit is installed and all other equipment on the same line is on. The operating gas pressure must be the same as that specied on the rating plate. If necessary, pressure adjustment may be made at the pressure regulator supplied with the appliance.
The appliance and its individual shut-o valve must be disconnected from the gas supply piping system during any pressure testing of that system pressures in excess of 1/2 PSIG (3.45kPa.).
Testing
All ttings and pipe connections must be tested for leaks. Use approved gas leak detectors, soap solution or equivalent, checking over and around all the ttings and pipe connections. DO NOT USE A FLAME! Accessibility to all gas lines and ttings require that valve panel(s) lower front panel(s), and/or oven rack(s) be removed. It may be necessary to remove, or at least raise and securely prop griddle(s), hot top(s), and/or top grate(s). All parts removed, (including fasteners), should be stored safely for re-installation.
1. Be sure that all valves and thermostats are in the “OFF” position.
2. Turn on the main gas supply valve. Light all top section pilots.
3. Leak test all valves and ttings as described at the beginning of this section. Correct any leaks as required and recheck.
4. Light the oven pilot.
5. If the range is equipped with an oven on/o valve separate from the thermostat, turn this valve on. If the oven thermostat dial has an “OFF” position, the thermostat is its own on/o valve.
6. In either case, now set the thermostat to 500°F, (260°C). Leak test all valves and ttings as described at the beginning of this section. Correct any leaks as required and recheck.
7. Shut o all valves and set thermostat dials to “OFF” or lowest position.
All units are tested and adjusted at the factory, however, burners and pilots should be checked upon installation and adjusted if necessary.
CAUTION: Gas will ow to the top section burners even if top section pilots are not lit. Gas will not be interrupted. It is the responsibility of the operator to conrm the proper ignition of each burner as it is turned on. Should ignition fail to occur 5 seconds after turning a burner on, turn the burner o, wait 5 minutes, and try again.
Part # 4515146 (02/29/08)Page 8
Part # 4515146 (02/29/08) Page 9
TESTING & ADJUSTMENT Continued
Griddle Seasoning
1. Remove all factory applied protective material by washing with hot water, mild detergent or soap solution.
2. Apply a thin coat of cooking oil to the griddle surface, about one ounce per square foot of griddle surface. Spread over the entire griddle surface with a cloth to create a thin lm. Wipe o any excess oil with a cloth.
3. Light all burners, set a lowest possible setting. Some discoloration will occur when heat is applied to steel.
4. Heat the griddle slowly for 15 to 20 minutes. Then wipe away oil. Repeat the procedure 2 to 3 times until the griddle has a slick, mirror like nish. Do this until you have reached the desired cooking temperature.
OPERATION
Important: Do not attain high (on valve control) or 450° (on thermostat control) during “break-in” period.
NOTE: Steel griddle surface will tone (blue discoloration) from heat. This toning will not diminish function or operation and is not a defect.
The griddle will not require reseasoning if it is used properly. If the griddle is over heated and product begins to stick to the surface it may be necessary to repeat the seasoning process again. If the griddle is cleaned with soap and water it will be necessary to reseason the griddle surface.
Open Top burners
Lighting:
1. Light pilots located in the center of each burner.
2. Turn valve completely on. Burner ame should be 1/2-inch, (13mm), stable blue ame, and should impinge on the bottom of a pot placed on the ring great.
Shut Down:
1. Turn all valves to the “OFF” position.
2. If the unit is to be shut down for an extended period of time, close the in-line gas valve.
CAUTION: Should burner ignition fail within 5 seconds, turn the burner valve o and repeat steps 1 through 5. If ignition continues to fail, consult your factory authorized service agency.
Hot top Sections
1. Raise or remove hot top sections. Each burner has one pilot located at the front right side of the burner.
2. Light pilots. The pilot burner should be adjusted to provide for rapid ignition of the burner.
3. Turn the burner valve on. A sharp blue ame should be approximately 1/4-inch, (6mm) high.
4. Replace Hot top Sections.
Valve Controlled Griddles
See the section on griddle seasoning before initial use.
1. Raise griddle at front and securely block.
2. Light pilots located at the front right side of each burner.
3. Turn burner valves completely on. Burners should have 1/2-inch to 5/8-inch (13mm to 16mm), stable blue ame.
4. Lower griddle carefully into position.
Raised Broiler/Griddles
See the section on griddle seasoning before initial use.
1. Light the pilots located in the broiler section.