Garland G56PB User Manual

Models:
G56PB G56PT G56PT/B
Item: ______________________________
Quantity: __________________________
Project: ____________________________
Approval: __________________________
Date: ______________________________
Air Deck Gas Deck Ovens
Model G56PT
Standard Features:
• Stainless Steel Front, Sides, Top, and Legs
• Porcelainized Control Panel
• Full Deck Width, Balanced Spring‑Loaded Door
• Stainless Steel Perforated Deck
• Adjustable Legs
• Electronic Ignition
• Snap Action Thermostat (550° F Max.)
• Heat Control Damper System
• Forced Air Combustion Burner; 80,000 BTU
• Single Speed Fan with ¾ HP Motor
• 55.5”W x 35.75"D Deck Surface
• 63"W x 45"D Floor Space
• 53"W’ x 7½"H Door Opening
• One Year Limited Parts and Labor Warranty (USA & Canada only)
Optional Features:
Stainless Steel Back Direct Connect Vent ‑ No
charge
Specifications:
Unique energy delivery system driven by controlled hot air flow designed for high volume operation. Offers minimum preheat time; no recovery time; consistent selected temperatures; high quality pro‑ duction, and menu versatility. Available in natural or propane gas.
®
Garland Commercial Ranges Ltd 1177 Kamato Road, Mississauga, Ontario L4W 1X4 CANADA
General Inquires 1-905-624-0260 USA Sales, Parts and Service 1-800-424-2411 Canadian Sales 1-888-442-7526 Canada or USA Parts/Service 1-800-427-6668
Model G56PT/B
Air Deck Gas Deck Ovens
MODEL
INPUT
(BTU)
G56PB 80,000 35.75(908) 55.5(1410) (6) 18” G56PT 80,000 35.75(908) 55.5(1410) (6) 18” 95 1000 /455
G56PT/B
160,000
DECK : In (mm)
WIDTH DEPTH
PIZZA
CAPACITY
MOTOR Cu Ft
120V, 1PH, 60Hz
95 1000 /455
15 Amps
2@35.75(908) 2 @55.5(1410) (12) 18” 190 2000 /910
(1 per deck)
Gas input ratings shown here are for installations tip to 2,000 feet (610mm) above sea level. BTU input ratings must be derated for high altitude installations.
MANIFOLD OPERATING
PRESSURE
Installation to Combustible Wall Entry
MINIMUM CLEARANCES
Nat Pro Sides Rear Base Crated Uncrated
3.5” WC 10.0” WC 6” (152mm) 6” (152mm) 8” (203mm) 45” (1143mm) 35‑1/2” (902mm)
3-3/8"
[86mm]
[1816mm]
42"
[1067mm]
DECK
71-1/2"
94-1/2"
[2400mm]
4-1/2"
[114mm]
9"
[229mm]
45-1/4"
[1149mm]
10-3/4"
[273mm]
4-1/2"
[114mm]
65-1/4"
[1657mm]
Deck with top power module and Direct Connect Venting
14"
[356mm]
18-1/2"
[470mm]
36-1/4"
[921mm]
6" DIA
[152 mm]
3/4" NPT REAR GAS INLET
Ship WT.
lb/Kg
63"
[1600mm]
6" DIA
[152 mm]
3/4" NPT
14"
[356mm]
18-1/2"
[470mm]
18-1/2"
[470mm]
24-1/4"
[616mm]
Garland Commercial Ranges Ltd 1177 Kamato Road, Mississauga, Ontario L4W 1X4 CANADA
REAR GAS INLET
63"
[1600mm]
3-3/8"
[86mm]
4-1/2"
[114mm]
101"
[2565mm]
78"
[1981mm]
48-1/2"
[1232mm]
DECK
30"
[762mm]
DECK
General Inquires 1-905-624-0260 USA Sales, Parts and Service 1-800-424-2411 Canadian Sales 1-888-442-7526 Canada or USA Parts/Service 1-800-427-6668
9"
[229mm]
7-1/2"
[191mm]
[1149mm]
45-1/4"
13-3/4"
[349mm]
10-3/4"
[273mm]
4-1/2"
[114mm]
71-3/4"
[1822mm]
Deck (1) top power module (1) bottom power module and Di‑ rect Connect Venting
Form# G56 (07/22/11)