IMPROPER INSTALLATION, ADJUSTMENT,
ALTERATION, SERVICE OR MAINTENANCE
CAN CAUSE PROPERTY DAMAGE, INJURY,
OR DEATH. READ THE INSTALLATION,
OPERATING AND MAINTENANCE
INSTRUCTIONS THOROUGHLY
BEFORE INSTALLING OR
SERVICING THIS EQUIPMENT
AND RETAIN FOR FUTURE REFERENCE.
THIS PRODUCT HAS BEEN CERTIFIED AS
COMMERCIAL COOKING EQUIPMENT AND
MUST BE INSTALLED BY PROFESSIONAL
PERSONNEL AS SPECIFIED.
IN THE COMMONWEALTH OF MASSACHUSETTS
THIS PRODUCT MUST BE INSTALLED BY A
LICENSED PLUMBER OR GAS FITTER. APPROVAL
NUMBER: G-1-07-05-28
For Your Safety:
Post in a prominent location, instructions to be
followed in the event the user smells gas. This
information shall be obtained by consulting
your local gas supplier.
Users are cautioned that maintenance and repairs must be performed by a Garland authorized service agent
using genuine Garland replacement parts. Garland will have no obligation with respect to any product that has been
improperly installed, adjusted, operated or not maintained in accordance with national and local codes or installation
instructions provided with the product, or any product that has its serial number defaced, obliterated or removed,
or which has been modified or repaired using unauthorized parts or by unauthorized service agents.
For a list of authorized service agents, please refer to the Garland web site at http://www.garland-group.com.
The information contained herein, (including design and parts specifications), may be superseded and is subject
to change without notice.
PLEASE READ ALL SECTIONS OF THIS MANUAL
GARLAND COMMERCIAL INDUSTRIES
185 East South Street
Freeland, Pennsylvania 18224
Phone: (570) 636-1000
Fax: (570) 636-3903
WARNING:
This product contains chemicals known to the state of california to cause cancer and/or birth defects
or other reproductive harm. Installation and servicing of this product could expose you to airborne
particles of glass wool/ceramic fibers. Inhalation of airborne particles of glass wool/ceramic fibers
is known to the state of california to cause cancer. Operation of this product could expose you to
carbon monoxide if not adjusted properly. Inhalation of carbon monoxide is known to the state of
california to cause birth defects or other reproductive harm.
Keep appliance area free and clear of combustibles.
G56PT/B160,00028.0 Sq. Ft.(12) 18”2@1000 lbs.910 kg
120V, 1Ø, 60Hz
15 Amps
(1 per deck)
1000 lbs.455 kg
Gas input ratings shown here are for installations tip to 2,000 feet (610mm) above sea level.
BTU input ratings must be derated for high altitude installations.
The model numbering system used indicates the input type,
deck size, intended application, and power module position
EXAMPLE:
G56PT
INPUT G = GAS MODEL
DECK WITH IN INCHES
TYPE OF OVEN; P = PIZZA
The model number on your oven is printed on the ratings
label, located on the side of the control panel housing.
NO LETTER = BAKE
POWER MODULE; T = TOP
B = BOTTOM
INTRODUCTION
Like any ne, precision built piece of equipment, your
appliance, should be given regular car and maintenance.
Periodic inspections by your local dealer or a qualied
service agent are recommended.
Rating Plate
When corresponding with the factory or your local
authorized factory service center regarding service problems
or replacement parts, be sure to refer to the particular unit
by the correct model number (including the prex and sux
letters and numbers) and the warranty serial number. The
rating plate located on the side of the control panel housing
contains this information.
INSTALLATION
The importance of proper installation of commercial
gas cooking equipment cannot be overstressed. Proper
performance of the equipment is dependent, in great part,
on the compliance of the installation with the manufacturer’s
specications. In addition compliance with the National
Fuel Gas code ANSI Z 223.1-1988/NFPA and/or Local Code is
required to assure safe and ecient operation.
In Canada, the installation and connection must comply with
CAN/CGA – B149 Installation codes and local codes where
applicable.
We suggest installation, maintenance and repairs should be
performed by your local authorized service agency listed in
your information manual pamphlet.
In the event you have any questions concerning the
installation, use, care or service of the product, write or call
our Product Service Department.
This product must be installed by professional personnel as
specied. Garland/U.S. Range products are not approved or
authorized for home or residential use, but are intended for
commercial applications only. Garland / U.S. Range will not
provide service, warranty, maintenance or support of any
kind other than in commercial applications.
Location of the Oven
Appliances shall be installed in a location in which the
facilities for ventilation permit satisfactory combustion of gas
and proper venting. Appliances shall be located so as not to
interfere with proper circulation of air within the conned
space. When buildings are so tight that normal inltration
does not provide the necessary air, outside air shall be
introduced.
Clearances
All burner adjustments and setting shall be made by a
qualied gas technician.
Delivery and Inspection
Upon delivery of your GARLAND Gas AIR DECK, inspect
the carton for external damage. Uncrate oven and check
for concealed damage. Any evidence of damage should be
noted on the delivery receipt which must be signed by the
driver.
Unit must be installed with no less than six inches (6”,
152mm) clearance from combustible construction at both
sides and rear.
Ventilation
Local codes and conditions vary greatly from one area
to another and must be complied with, following are
the minimum requirements for good ventilation. Please
remember these are general recommendations or
guidelines, you may have a special conditioner problem that
will require the services of a ventilation engineer or specialist.
Proper ventilation is the oven owner’s responsibility.
Improper ventilation can inhibit oven performance.
Part # 1382670 (12/07)Page 6
Part # 1382670 (12/07)Page 7
INSTALLATION Continued
Canopy Method
The ideal method of venting a gas oven is through the use of
a properly designed canopy which should extend six inches
beyond all sides of the appliance and six feet six inches
from the oor. A strong exhaust fan will create a vacuum
in the room, for an exhaust system vent to work properly,
replacement air must enter the room in which the vent is
located. The amount of air which enters must equal the
amount exhausted.
Direct Connection
An unrestricted vent pipe that provides exit air at the oven
of a minimum of 55 C.F.M. per oven must be provided for the
vent pipe at the top of the oven. The vent pipe should be a
minimum of 6” (152mm) in diameter. A direct connect kit can
be obtained through your dealer.
Do not Undersize Vent Pipe. This can cause resistance to ow
and impede good venting. If a horizontal run must be used
it should rise no less than 1/4” for each linear foot or run. The
ue should rise two feet to three feet above the roof line or
two feet to three feet above any portion of a building within
a horizontal distance of ten feet.
More than 10' (3 meters)
Direct Connection Instructions
The G56P-T/B (or double deck), may be direct vented to the
outside. In order to accomplish direct venting and maintain
proper oven operation, it is necessary to install a Direct
Venting Kit part #CK4529. This kit consists of a Heat Collector
(Part #1190100). The Heat Collector Box is mounted over the
ue at the rear of the oven and Draft Diverter is attached to
the top of the Heat collector as shown on next page.
The Heat Collector must be positioned over the rear ue and
as far forward as possible on top of oven. It is necessary to
mark and drill mounting holes on oven top to fasten Heat
Collector securely in place.
An unrestricted vent pipe that provides exit air at the oven
of a minimum of 55 C.F.M. per oven must be provided for the
vent pipe at the top of the oven. The vent pipe should be a
minimum of 6” (152mm) in diameter. A direct connect kit can
be obtained through your dealer.
6" Stove Pipe
15"
10"
Draft Diverter
Heat
Collector
16"
3' (90cm) Min.
Termination More than 10 feet (3 meters) from ridge
Less than 10 feet (3 meters)
2' (60cm)
Min.
Termination Less than 10 feet (3 meters) from ridge
3' (90cm) Min.
Oven
Flue
Gas
Pipe
Gas Connections
The 1” NPT inlet of the rear must be considered in piping
the gas supply for double deck units. Undersized gas supply
line(s) may restrict the gas supply and aect performance.
If other gas appliances are supplied by the same supply
line, the supply line must be sized to carry the combined
volume without causing more than 1/2” pressure drop at the
manifold of each appliance on the line at full rate.
INSTALLATION Continued
The appliance and its individual shuto valve must be
disconnected from the gas supply piping system during any
pressure testing of that system at pressures in excess of
1/2 PSIG (3.45 KP2).
The appliance must be isolated from the gas supply piping
system by closing its individual manual shuto valve during
any pressure testing of the gas supply piping system at test
pressures equal to or less then
1/2 PSIG (3.45 KP2).
NOTE: During installation there will be air in the gas line. This
air will have to be bled o before ignition can be established.
The electrical ignition system has a four second lock-out as a
safety device.
Electrical Connections
A 15 AMP service must be provided for each oven. For 115
Volt usage a cord and plug is provided but connection to
the electrical service must comply with local codes or in
the absence of local codes with the National electrical code
ANSI/NFPA No. 70-1987 (or latest edition).
Each oven is electrically equipped with a cord set with a
three prong plug which ts all standard 115 Volt three prong
grounded receptacle. A wiring diagram is attached to the
rear of the unit.
POWER FAILURE: In the event of a power failure, no
attempt should be made to operate this oven. This unit is
gas operated but has electrical features, motors, controls
and burner systems.
Electrical Grounding Instructions
WARNING: All ovens, when installed, must be electrically
grounded in accordance with local codes, or in the absence
of local codes with the Nation Electrical code ANSI/NFPA 701987 (or latest edition).
This appliance is equipped with a three prong (grounding)
plug for your protection against shock hazard and should be
plugged directly into a properly grounded three pronged
receptacle. Do not cut or remove the grounding prong
from this plug.
Unit Assembly
1. Before assembly and connection check gas supply and
electrical service. It is recommended that a separate
electrical circuit be provided for the Air Deck. A single
unit will require 15 AMPS and a double will require a
20 AMP circuit.
2. Gas conditions for this unit are listed on the rating
plate, located just forward of the Louvered Panel of the
Power Module. If this is a new installation, have the gas
authorities check meter size and piping to assure that
existing meter and piping will supply fuel at the oven
with 3.5” W/C (for Natural Gas) or 10.0” W/C (for L.P. Gas)
and not more than 1/2” water column pressure drop.
NOTE: When checking pressure, be sure that all other
equipment on the same gas line is on. A gas pressure
regulator is built into the combination control valve and no
adjustment is needed.
Leg Installation – All Models
1. Oven is crated and shipped on its base. When uncrating,
the bottom of unit is exposed to facilitate leg installation.
Position the legs inside front and rear corners from frame.
Start each bolt, threading them into the weld nuts on
the base frame. Four (4) bolts with washers must be used
to secure each leg in place. Tighten the bolts evenly and
securely. The legs are interchangeable front to back, for
models “B” – longer legs for left side – shorter legs for
mounting to Power Module section: See line drawing.
Assembly of Double Unit
1. Install legs on bottom unit. Then place in position desired.
2. Place 2 x 4’s on top of the lower section about six inches
from each side, running front to rear.
3. Raise the top section and position it on the 2 x 4’s so that
the front, rear and sides of top section with the lower
oven section. Carefully remove the 2 x 4’s lowering the
upper oven into place. It is not necessary to bolt the
sections together.
Part # 1382670 (12/07)Page 8
Part # 1382670 (12/07)Page 9
CONCEPT OF AIR IMPINGEMENT COOKING
The “AIR DECK” Oven produced by GARLAND COMMERCIAL
INDUSTRIES INC., utilizes a revolutionary cooking concept,
called “AIR IMPINGEMENT”. It provides exceptional baked
food product quality in far less time than conventional
devices on the market. The “AIR IMPINGEMENT” system
directs a high velocity stream of heated air at the food
product being baked.
This blast eect penetrates the boundary layer of air
encircling the product and heats the food more eciently,
because the air concentrates heat on the food product.
Greater heat transfer rates, results in products baking two to
four times faster than conventional means, are possible with
“AIR IMPINGEMENT”.
OPERATION
The “AIR IMPINGEMENT” process develops the high velocity
air stream with a specially designed fan that draws superheated air from a heat source (either gas or electric). This
air is directed through a plenum chamber to patented “JET
PLATES” which have hundreds of focused jet ports that
“impinge” the heated air onto the food product surface. The
heated air is re-cycled to the heat source after striking the
food product, thus reducing energy consumption.
The “AIR IMPINGEMENT” process is tolerant enough for
sensitive food products and eects proper crisping and even
browning of such products as they pass through the oven,
because air is the medium which heats the food product. The
adjustable air controls for top and bottom jet plates allow
further enhancement of cooking.
Once the equipment has been installed and tested by
qualied professional personnel, the oven is ready for
operation.
Many of the parts used in the oven have a thin protective
oil covering. The oil should be burned o before the oven is
used for the production of food products. It is normal for the
unit to smoke while burning o excess oil. Washing the deck
of the oven with a damp clean cloth and mild soap solution
will remove some of the protective oil coating.
To start the oven, switch the power to on. Set oven
temperature dial to 400 degrees and let oven heat and
operate at this temperature for at least one hour.
The “Air Deck” utilizes an automatic ignition and pilot
ame sensing system. During normal operation, the power
burner will cycle on and o as necessary to maintain oven
temperature. There is a short “time delay” built into the
circuitry, and you should not be alarmed when the oven
“calls for heat” and the power burner does not operate
immediately.
You will nd that cooking with the “Air Deck” oven will be
much faster than the standard Bake/Roast and Pizza Ovens.
You will have to experiment with your recipes to become
accustomed to this new method. For example the warmup time is shorter than standard ovens. The oven can be
warmed and ready for use in as little as twenty (20) minutes.
A large pizza can be ready to serve in as little as ve (5)
minutes. These are “ideal conditions” times and will vary with
ventilation and use.
Heat control vent shutters (2), are located on the right side of
the oven cavity. These shutters must be adjusted to provide
the air ow top and bottom that you desire for your cooking
needs. Adjusting these shutters will provide you with many
cooking variations.
If unit fails to operate, it is recommended that only qualied
service personnel perform the repairs on this unit. A
troubleshooting chart is provided in this manual to assist
qualied service personnel in repair of the unit. However,
before you call a service technician you may want to make a
few simple checks. Make sure electricity and gas are available
to the oven prior to calling a Service Technician.
CAUTION: Disconnect power supply before attempting to
clean or service.
OPERATION Continued
Air Shutter Adjustments
To adjust the dampers, loosen wing nut holding damper
position, with deck and damper tool provided, insert the
damper end of the tool into the receptacle on the damper,
and raise the damper to disengage the damper from the
notched position, slide the damper at a 45 degree angle to
engage the next position, retighten wing nut.
Upper Damper
Lower Damper
To increase Top air, adjust upper damper “down”. Position in
notch, and tighten thumb screw.
To increase Bottom Air, adjust lower damper “up”. Position
damper in notch, and tighten thumb screw.
Decrese Air
Increase Air
Increase Air
Decrese Air
Possible Settings
PIZZA PRODUCTTIMETEMP FTEMP CUPPERLOWER
Fresh Dough Cheese Pizza6:00-7:00450-575234-250Fully ClosedFully Open
Fresh Dough with Toppings7:30-8:30450-475234-2501/2 OpenFully Open
Pre-Baked Dough Cheese Pizza5:00-6:00450-475234-2501/2 OpenFully Open
Pre-Baked Dough with Toppings5:30-6:30450-475234-2501/2 OpenFully Closed
Pre-Cooked Black Porcelain Pan10:00-12:00475-500250-260Fully ClosedFully Open
Deep Pan Pizza8:30-9:30475-500250-260Fully ClosedFully Open
Pre-Baked Party Pizza16:00-20:00475-500250-260Fully ClosedFully Open
Part # 1382670 (12/07)Page 10
Part # 1382670 (12/07)Page 11
OPERATION Continued
Application Trouble Shooting
Dark Pizza Top1 Decrease top air by adjusting upper damper “up”
2 Decrease cooking time
3 Decrease temperature.
Pizza Top Too Light1 Increase top air by adjusting upper damper “down”.
2 Increase cooking time
3 Increase temperature.
Pizza Bottom too Dark1 Decrease bottom air by adjusting lower damper “down
2 Decrease cooking time
3 Decrease temperature
Pizza Bottom and Top Too Light1 Increase cooking time
2 Increase temperature
Pizza bottom and Top Too Dark1 Decrease cooking time
2 Decrease temperature
Pizza Bottom Too Dark and Top too Light1 Increase top air by adjusting top damper “down”
2 Decrease bottom air by adjusting bottom damper “down”
3 Lower cooking temperature and decrease bottom air by adjusting
bottom damper “down”
4 Lower cooking temperature and increase top air by adjusting top
damper “down”
Pizza Bottom Too Light and Top Too Dark1 Decrease top air by adjusting top damper “up”
2 Increase bottom air by adjusting bottom damper “up”
3 Increase cooking temperature and decrease top air by adjusting upper
damper “up”.
Loading...
+ 25 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.