INSTALLATION AND
OPERATION MANUAL
GARLAND FONDANT
WARMER,
MODEL EFW800
FOR YOUR SAFETY:
DO NOT STORE OR USE GASOLINE
OR OTHER FLAMMABLE VAPORS OR
LIQUIDS IN THE VICINITY OF
THIS OR ANY OTHER
APPLIANCE
PLEASE READ ALL SECTIONS OF THIS MANUAL
AND RETAIN FOR FUTURE REFERENCE.
THIS PRODUCT HAS BEEN CERTIFIED AS
COMMERCIAL COOKING EQUIPMENT AND
MUST BE INSTALLED BY PROFESSIONAL
PERSONNEL AS SPECIFIED.
WARNING:
IMPROPER INSTALLATION, ADJUSTMENT,
ALTERATION, SERVICE OR MAINTENANCE
CAN CAUSE PROPERTY DAMAGE, INJURY,
OR DEATH. READ THE INSTALLATION,
OPERATING AND MAINTENANCE
INSTRUCTIONS THOROUGHLY
BEFORE INSTALLING OR
SERVICING THIS EQUIPMENT
INSTALLATION AND ELECTRICAL CONNECTION
MUST COMPLY WITH CURRENT CODES:
IN CANADA - THE CANADIAN ELECTRICAL
CODE PART 1 AND / OR LOCAL CODES.
IN USA – THE NATIONAL ELECTRICAL CODE
ANSI / NFPA – CURRENT EDITION.
ENSURE ELECTRICAL SUPPLY CONFORMS WITH
ELECTRICAL CHARACTERISTICS SHOWN ON
THE RATING PLATE.
Users are cautioned that maintenance and repairs must be performed by a Garland authorized service agent
using genuine Garland replacement parts. Garland will have no obligation with respect to any product that has been
improperly installed, adjusted, operated or not maintained in accordance with national and local codes or installation
instructions provided with the product, or any product that has its serial number defaced, obliterated or removed,
or which has been modified or repaired using unauthorized parts or by unauthorized service agents.
For a list of authorized service agents, please refer to the Garland web site at http://www.garland-group.com.
The information contained herein, (including design and parts specifications), may be superseded and is subject
to change without notice.
GARLAND COMMERCIAL INDUSTRIES
185 East South Street
Freeland, Pennsylvania 18224
Phone: (570) 636-1000
Fax: (570) 636-3903
GARLAND COMMERCIAL RANGES, LTD.
1177 Kamato Road, Mississauga, Ontario L4W 1X4
CANADA
Phone: 905-624-0260
Fax: 905-624-5669
Enodis UK LTD.
Swallow eld Way, Hayes, Middlesex UB3 1DQ ENGLAND
Telephone: 081-561-0433
Fax: 081-848-0041
Part # 4521055 (12/07) © 2006 Garland Commercial Industries, Inc.
GENERAL INFORMATION
Unpacking:
Carefully remove unit from carton. Remove all packing
materials, any protective material covering the stainless steel
should be removed immediately after the unit is installed.
Serial Plate Location:
Electrical rating is shown on the serial plate and is readily
visible on the rear of the unit next to the power supply cord
inlet.
Safety:
• A qualied person must make the installation in
accordance with the authority having jurisdiction and
local codes.
• This unit must only be operated by a qualied person. DO
NOT operate without reading this manual.
• DO NOT operate this appliance unless all service and
access panels are in place and fastened properly.
• DO NOT attempt to repair or replace any part of this
appliance unless all main power supplies have been
disconnected.
• DO NOT clean this appliance unless the power supply is
disconnected.
• DO NOT immerse appliance in water.
WARNING
To avoid serious personal injury:
• USE EXTREME CAUTION in setting up, operating and
cleaning these appliances to avoid coming in contact
with hot surfaces. Wear suitable protective clothing or use
proper utensils to prevent the risk of burns.
• NOTE all warning labels and markings on this appliance,
which call attention to further dangers and necessary
precautions.
Wall Clearances:
Sides: 0
Rear: 0
Part # 4521055 (12/07)Page 2
SPECIFICATIONS
20"
[508mm]
12"
[305mm]
8.34" MIN [219mm]
8.78" MAX [223mm]
7.42"
[189mm]
13.55"
[344mm]
24.75"
[629mm]
21.56"
[548mm]
24.11"
[612mm]
0.50"
[12.7mm]
4.02"
[102mm]
5.20"
[132mm]
Voltage Phase kW
120 1 .80 6.7
Nominal
Amperes
Connection Type
6' cord
w/NEMA 5-15P plug
Clearances
Part # 4521055 (12/07) Page 3
Installation Entry
Sides Rear Crated Uncrated
0” 0" 15.8" (401mm) 13.55" (344mm) 29 lb (13.2kg)
Shipping
Weight