IMPROPER INSTALLATION, ADJUSTMENT,
ALTERATION, SERVICE OR MAINTENANCE
CAN CAUSE PROPERTY DAMAGE, INJURY,
OR DEATH. READ THE INSTALLATION,
OPERATING AND MAINTENANCE
INSTRUCTIONS THOROUGHLY
BEFORE INSTALLING OR
SERVICING THIS EQUIPMENT
AND RETAIN FOR FUTURE REFERENCE.
THIS PRODUCT HAS BEEN CERTIFIED AS
COMMERCIAL COOKING EQUIPMENT AND
MUST BE INSTALLED BY PROFESSIONAL
PERSONNEL AS SPECIFIED.
INSTALLATION AND ELECTRICAL CONNECTION
MUST COMPLY WITH CURRENT CODES:
IN CANADA - THE CANADIAN ELECTRICAL
CODE PART 1 AND / OR LOCAL CODES.
IN USA – THE NATIONAL ELECTRICAL CODE
ANSI / NFPA – CURRENT EDITION.
ENSURE ELECTRICAL SUPPLY CONFORMS WITH
ELECTRICAL CHARACTERISTICS SHOWN ON
THE RATING PLATE.
Users are cautioned that maintenance and repairs must be performed by a Garland authorized service agent
using genuine Garland replacement parts. Garland will have no obligation with respect to any product that has been
improperly installed, adjusted, operated or not maintained in accordance with national and local codes or installation
instructions provided with the product, or any product that has its serial number defaced, obliterated or removed,
or which has been modified or repaired using unauthorized parts or by unauthorized service agents.
For a list of authorized service agents, please refer to the Garland web site at http://www.garland-group.com.
The information contained herein, (including design and parts specifications), may be superseded and is subject
to change without notice.
GARLAND COMMERCIAL INDUSTRIES
185 East South Street
Freeland, Pennsylvania 18224
Phone: (570) 636-1000
Fax: (570) 636-3903
The instructions in this manual are fundamentally important
and must be taken into account during assembly, operation
and maintenance. They must therefore be read very carefully
before installation and operation by the responsible
specialist sta and the operator(s). After installation keep in a
promenade position for consultation and reference.
Warning
Risk of fire or electric
shock
Do not open
Description Of Warning Signs
Identifies safety information
about dangers which may
cause serious personal injury
if equipment is not operated
properly.
Dangerous voltage warning
symbol, indicates a risk of
electric shock and hazards from
dangerous voltage.
Indicates a hazard or unsafe
CAUTION
practice which could result
in minor personal injury or
property damage.
To reduce the risk of fire or electric
shock, do not remove or open cover.
No user Serviceable parts inside.
Refer servicing to qualified personnel.
Warning signs mounted directly on the cooker must be
observed at all times and kept in a fully legible condition
Health Information
WARNING:
This product contains chemicals known
to the State of California to cause cancer.
Installation and servicing of this product
BH/IN10.24” x 10.24” (260mm x 260mm)12.20’ x 12.20” (310mm x 310mm)
SH/IN12.60” X 12.60” (320mm x 320 mm)15.12” x 15.12” (384mm x 384mm)
SH/WO/INø 11.81” (300mm)15.12” x 15.12” (384mm x 384mm)
Part # 4520898 (03/31/11)Page 6
GENERAL INFORMATION
Purpose Of Induction Cookers
The induction cookers are especially suitable as built-in
cookers in closed counters for the preparation of meals. The
cookers can be used for cooking, keeping warm, ambéing,
roasting, etc. of food. Only recommended types and sizes of
pans should be used. Do not use NO NAME pan material but
only pans appropriate for induction cooking!
Description Of Products
Components Supplied
1. Generator with built-in frame including glass top.
2. Operating unit.
Product Overview
Garland supplies several basic types of units with dierent
performances and measurements. Built with a robust
method of construction, they are compact and powerful with
a revolutionary technology in a complete case of CrNi-steel.
Equipped with continuous control, allowing for ecient
cooking and have the following features:
• Simple operation with rotary switch with integrated
mains switch.
• Compact module in a frame design with an induction
generator, controller, coil, ventilator, glass ceramic
cooking zone with power rotary knob and LED-indicator
xed on a CNS plate.
Control knob
The number that points to the operation indicator marks the
actual position of the control knob.
OFF-POSITION
0 Points to the operation indicator
ON-POSITION
Any position when a number other than
0 points to the operation indicator
• Electronic limitation of the connected load.
• Compact powerful electronics enable tight construction
and safe operation.
• A maximum of safety thanks to multiple functions of
protection and checking.
• Short cooking time.
• Compact measurement – light weight.
• Fullls the latest standards: VDE EN 60335-1; -2/36;
CE-conforming UL 197; CAN/CSA/C 22.2 No. 109.
Built In Units At A Glance
Before carrying out function checks, the operator must know
how to operate the cooker.
Part # 4520898 (03/31/11)Page 7
INSTALLATION
The generator is delivered with rmly xed built-in frame
including glass top and separate operating unit.
Please note that the unit is
not completely assembled.
CAUTION
Pay close attention to the
requirements for
installation section.
Requirements For Installation
The induction appliance has to be built into a clean and even
surface (table, counter, stove) at a denite place.
Make sure that all installation requirements and instructions
are followed.
Built In appliances must only be installed in closed
counters
The rear side of the induction unit below the fan has to be
absolutely free from obstruction and air intake. Optimal air
intake must not be reduced by the installation. If necessary,
an optional air supply has to be achieved by adding a exible
air duct including a shackle (available as accessory). Be sure
that the air inlet and air outlet openings have a clearance of
at least 1 3/16” (30 mm) from obstructions like walls or oors.
Also ensure that the air of air inlet and air outlet do not mix.
Garland recommends guaranteeing a supply of fresh air by
xing an air duct including shackle or by air openings. The air
exit must not to be hindered by any obstructions.
Electrical Supply
Please observe the following rules:
1. Check and ensure that the supply voltage and the line
current matches the specications given on the rating
plate.
2 This induction appliance is equipped with mains cable
and plug which can be connected to the socket. The
connector must be easily accessible to disconnect the
unit from the electrical supply.
3. When residual current circuit breakers are used, they
must be rated for a breaking current of 30mA or more.
Ventilation
Please read carefully and comply with the following rules.
1. This induction unit is equipped with an internal air
cooling system. Be sure that the air supply and air exhaust
are not blocked (wall, fabric etc.).
2. Ensure that the induction unit does not take in hot
ambient air (concerns units standing side by side, or one
behind the other, or standing near a frying pan or an
oven), otherwise an air duct including shackle has to be
added.
3. The induction unit must not be placed next to an oven or
another heat producing unit.
4. The air intake temperature must be under 104°F (40°C).
5. The operating sta has to make sure that installation,
support and inspection is done by qualied personnel.
Part # 4520898 (03/31/11)Page 8
INSTALLATION continued
Cut Out For Model BH/IN 2500
The size of the cut out in the built-in area must be,
11.41” x 11.41” (290 x 290mm), the depth 7.87” (200mm) and
the base at least 13.39” x 11.75” (340 x 273mm).
0.06"
[1.5mm]
Side View of the right
Front view
air exitair exit
6.73"
[171mm]
12.20"
[310mm]
Ventilator
Mains
Cable
11.02"
[280mm]
10.23"
[260mm]
Ceran-surface
air supply
4.06"
[103mm]
10.23"
[260mm]
5.04"
[128mm]
Mounting height
min. 7.87"
[200mm]
Connection
clutch for
operation device
3.07"
[84mm]
11.02"
[280mm]
Required cut-out of the work top
min. 11.42" x 11.42" [290mm x 290mm]
Plug-in clutch for
operation device
7.32"
[186mm]
air supply
12.20"
[310mm]
Part # 4520898 (03/31/11)Page 9
Loading...
+ 19 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.