Gardner Bender JetLine B4500K, JetLine B60, JetLine Blo-Vac BV208DA Instruction Sheet

1.0 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.0 Safety Symbol Definitions . . . . . . . . . . . . . . . . . .2
3.0 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
4.0 Grounding Instructions . . . . . . . . . . . . . . . . . . . . .3
5.0 Technical Specifications . . . . . . . . . . . . . . . . . . .3
6.0 Product Description . . . . . . . . . . . . . . . . . . . . . . .3
7.0 Use and Operation . . . . . . . . . . . . . . . . . . . . . . . .4
7.1 Blowing Line in Conduit . . . . . . . . . . . . . . . . .4
7.3 Selecting the Pull Lines . . . . . . . . . . . . . . . . .4
B3000 Blower for B60
B4500K Blower Kit
RPS-0106 01/02
Instruction Sheet
B4500K, B60, BV208DA
IMPORTANT RECEIVING INSTRUCTIONS
Visually inspect all components for shipping damage. If shipping damage is found, notify carrier at once. Shipping damage is NOT covered by warranty. The carrier is responsible for all repair and replacement costs resulting from damage in shipment.
SAFETY ISSUES
IMPORTANT – USER SAFETY AND PROTECTION: In setting up systems to fit your operations, care must be taken to select the proper components and design to insure appropriate that all safety measures have been taken to avoid the risk of personal injury and property damage from your application or system.
GARDNER BENDER IS NOT RESPONSIBLE FOR DAMAGE OR INJURY CAUSED BY UNSAFE USE, MAINTENANCE OR THE APPLICATION OF ITS PRODUCTS. Please contact Gardner Bender for guidance when you are in doubt as to the proper safety precautions to be taken in designing and setting up your particular application.
7.4 Power Saver™ Line Packages . . . . . . . . . . .5
7.5 Tag-Along™ Line Packages . . . . . . . . . . . . .5
7.6 PL Series Pull Line . . . . . . . . . . . . . . . . . . . .5
7.7 Seal-Offs . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
7.8 Line Carriers . . . . . . . . . . . . . . . . . . . . . . . . .7
7.9 Blowing or Vacuuming Thru Conduit . . . . . . .8
8.0 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . .10
9.0 Jetline
®
Systems . . . . . . . . . . . . . . . . . . . . . . . .10
9.1 B4500K Line Shooter™ Blowing System . .11
9.2 B60 Super Blower™ System . . . . . . . . . . . .12
BV208DA Blo-Vac
2
1.0 DESCRIPTION
The GB/JetLine®Blower and Blo-Vac™ Systems are low pressure tools that deliver high volume air stream, which is used to place pull line in most conduit from 1⁄2" to 6" diameter.
Blow-Vac™ systems are intended for commercial use only. The systems are convenient to use in new and existing construction. They require a 120 V, 60 Hz grounded power source. See 5.0 Technical Specifications, GB/JetLine
®
Blowers Table and GB/JetLine®Blo-Vac™ Table. The Blower or Blo-Vac™ System consists of four basic
components:
• The Power Unit – a high volume air or vacuum source.
• Hose and Seal-Off – to channel the air into the conduit and form a seal at the conduit entrance.
• A Line Carrier – to serve as a movable object that supplies the pulling force to install pull line in conduit.
• Pull Line – for pulling wire through the conduit, to pull rope or cable for large or difficult runs.
A thorough understanding of all components and their functions and operating precautions is essential for safe and efficient use of the system.
Read and understand all the instructions before attempting to use the system or blow line into conduit.
2.0 SAFETY SYMBOL DEFINITIONS
The symbol below is used to call your attention to instructions concerning your personal safety. Watch for these symbols. They point out important safety precautions. They mean
“ATTENTION! Become alert. Your personal safety is involved.” Read the message that follows and be alert to the
possibility of personal injury or death.
DANGER: Indicates a high probability that death,
severe bodily injury or major property damage could result.
WARNING: Is serious but less inevitable. There is some probability that death, severe bodily injury or major property damage could result.
CAUTION: Is less serious but still demands attention. Indicates a hazard which may result in minor injury or property damage.
3.0 WARNINGS
This section contains information for your protection, safety and quick reference. When using an electrical appliance basic precautions should always be followed, including the following.
Read all Instructions before using the Blo-Vac
System.
CAUTION: Do not leave the Blo-Vac™ when plugged in. Unplug from outlet when not in use and before servicing.
CAUTION: To reduce the risk of electrical shock: Do not expose to rain. Store indoors.
CAUTION: Use only as described in this manual. Use only manufacturer’s recommended attachments.
WARNING: Do not use with damaged cord or plug. If the Blo-Vac™ is not working as it should, has been dropped, damaged, or dropped in water, return it to a service center.
CAUTION: Do not pull or carry by cord, use cord as a handle, close a door on cord, or pull around sharp edges or corners. Do not run the Blo-Vac
over cord.
Keep cord away from heated surfaces.
WARNING: Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord.
CAUTION: Do not handle plug or Blo-Vac
with
wet hands.
CAUTION: Do not put any object into openings. Do not use with any opening blocked: keep free of dust, lint and anything that may reduce air flow.
WARNING: Keep hair, loose clothing, fingers and all parts of body away from openings and moving parts.
WARNING: Do not pick up anything that is burning or smoking, such as cigarettes, matches, or hot ashes.
CAUTION: When used for vacuum clean-up, do not use without filter bag in place.
CAUTION: Turn off switch before unplugging.
DANGER: Do not use to pick up flammable or combustible liquids such as gasoline. Do not use in areas where they are present.
WARNING: Use extra caution when working on a ladder, elevated platforms, stairs, etc.
WARNING: Do not use the power unit in a manhole — keep the power unit above ground.
DANGER: All GB/JetLine
®
conduit fishing Blo-Vac
systems are designed to force loose debris of all types out of the conduit by means of a pressurized force. Serious or critical injury may result to anyone struck by high velocity debris or the line carrier. Warn all personnel to stand clear of the conduit exit prior to pressurization procedures or blowing line into the conduit.
CAUTION: GB/JetLine
®
Blo-Vac™Systems have been designed specifically for fishing conduit. The system, under certain field conditions, may be used to remove debris or water from the conduit. The electric motor is protected from liquid entering the fan area by a float ball. If liquid is discharged, the float ball has been defeated. Immediately unplug unit from power source and check to make sure the float ball is functioning properly and the sealing area is free of foreign matter.
DANGER: Failure to observe these instructions or misuse of equipment could result in serious injury or possible death.
4.0. GROUNDING INSTRUCTIONS
The GB/JetLine®blowers and Blo-Vacsystems require a 120 V, 60 Hz, 15 A circuit; with the exception of the B3000 power unit which requires a 120 V, 60 Hz, 30 A circuit; and must be grounded. If the power unit should malfunction or breakdown, grounding provides a path of least resistance for the electrical current to reduce the risk of electrical shock. These power units are equipped with a cord that has a grounding conductor and grounding plug. The plug must be inserted into an outlet that is properly grounded in accordance with all codes and ordinances. See Figure 1.
CAUTION: Improper connection of the equipment grounding conductor can result in a risk of electrical shock. Check with a qualified electrician or service person if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with the Blo-Vac™. If it will not fit the outlet, have the correct outlet installed by a qualified electrician.
5.0 TECHNICAL SPECIFICATIONS
6.0 PRODUCT DESCRIPTION
GB/JetLine®Blowers and Blo-Vac™systems are designed to provide a convenient means of installing pull line in a sealed conduit. Sealed conduit for this purpose is considered EMT conduit with compression type couplings, rigid conduit with threaded joints, or PVC conduit with adhesive bonded joints.
Conduit with set screw type couplings does not effectively seal joints and substantial air or vacuum loss occurs making it difficult to maintain pressure or vacuum to place a line in the conduit.
Blower Systems
GB/JetLine
®
supplies two blower systems; the B4500K Line
Shooter(for fishing from
1
2" through 4" trade size conduit)
and the B60 Super Blowerfor heavy duty work in conduit from 21⁄2" through 6". See Figures 2 and 3.
B4500K Line Shooter
The B4500K Line Shooterconduit fishing kit is equipped with a light weight 1261 Power Unit, three foot hose, shoulder strap, power saver line packages, foam line carriers, inflatables and accessories for fishing conduit from 1⁄2" through 4". Bulk pull line is not included with the kit.
3
Grounding Pin
Grounded
Outlet Box
Adapter
Metal
Screw
Tab for
Grounding Screw
Grounding
Blade
Figure 1. Grounding Methods
125 V
30 A
NEMA
L5-30R
GB/JetLine®Blowers
B4500K B60
Power Unit 1261 B3000
Voltage 120 120
Frequency 60 Hz 60 Hz
AMPS 7.50 23
In. Water Lift (sealed) 85-92 85-92
P.S.I. 3.31 3.31
CFM 90 270
No. of Motors 1 3
Impeller Stages (Fans) 2 2
Thermal Overload Yes Yes
Motor Type (Cooling) Flow Through Flow Through
Handling Portable Portable
Weight 7.5 lb 35 lb
Hose Dia. (Inch) 11⁄2 21⁄2 Length (Feet) 3 25
GB/JetLine®Blo-Vac™
BV208DA
Power Unit 1523
Voltage 120
Frequency 60 Hz
AMPS 13.8
Inches Water Lift (sealed)* 130-135
P.S.I.* 4.86
CFM 92
No. of Motors 1
Impeller Stages (Fans) 3
Thermal Overload No
Motor Type (Cooling) By-Pass
Handling Cart
Recovery Cap. (Gals) 9**
Height with Cart (Inch) 41
Motor Brush Life (Hours) 750
Weight 50 lb
Hose Dia. (Inch) 11⁄2
Length (Feet) 8
* Will vary with voltage and atmospheric conditions. ** When using recovery compartment and tool storage
compartment together.
Figure 2. 1261 Blower
B60 Super Blower™
The B60 Super Blowerwas designed for use in long underground single bore conduit from 2
1
2" through 6". The
B3000 Power Unit must remain above ground for safety reasons, and the 21⁄2" diameter x 25' long hose and seal-off are used in the manhole. The portable triple motor power unit provides a high volume of air to blow a line in large bore conduit whether above ground or below ground.
Blo-Vac™ Systems
GB/JetLine
®
Blo-VacSystems: BV208DA Super-Ultra Blo-Vacprovides blowing or vacuuming capabilities for conduit fishing of
1
2" through 6". These systems provide a
higher output pressure for more difficult runs. The water lift capabilities of the Blo-Vacis the same for blowing or vacuuming. See 5.0 Technical Specifications, GB/JetLine
®
Blo-Vac™Table.
Each Blo-Vacsystem is cart mounted for easy transporting around the job site. Each Blo-Vacunit has three compartments which are easily separated. The top section is the power unit, the center section is the recovery compartment, and the bottom section is storage for accessories. See Figure 4. The power unit and the recovery compartment may be unlatched from the tool storage compartment and used as a portable blower vacuum system. All Blo-Vacsystems are equipped with a 1
1
2" diameter x 8'
long hose and seal-offs to fit
1
2" through 6" conduit.
The BV208DA Super Ultra Blo-Vachas a powerful three­stage motor fan section. The recovery capacity is 41⁄
2 gallons
expandable to 9 gallons by using the tool storage compartment above the recovery compartment after removing the false bottom. Housings are made of high impact polypropylene.
7.0 USE AND OPERATION
The primary purpose of the GB/JetLine®Conduit Fishing System is to place a pull line in the conduit by the quickest and easiest means available. The GB/JetLine®Blower and Blo-Vacsystems are low pressure, high volume machines that are easy and convenient to use.
7.1 Blowing Line in the Conduit
The GB/JetLine®Blower and Blo-Vacsystems are designed to blow line in a sealed conduit such as EMT conduit with compression type couplings, rigid conduit with threaded joints, or PVC conduit with adhesive bonded joints. These types of conduit require very little effort to install a pull line with the Blower or Blo-Vacsystem.
There are some conduit runs that will be difficult or impossible to blow a line in, such as:
Conduit containing hard packed sand, silt, debris or concrete.
Conduit containing water with a head greater than the maximum water lift of the Blower or Blo-Vacsystem.
Conduit with leaking or separated joints.
Conduit with two sizes of duct connected by a reducer.
Conduit with unsealed set screw couplings.
Small diameter conduit of several hundred feet with
multiple bends.
Let Gravity Help
When blowing line in conduit of tall buildings or underground duct, start at the highest elevation of the conduit entrance. In underground duct; water may have accumulated in low points of the run, and the blower may not be able to force it out. Start at the highest point.
7.2 Preparation
It is helpful to know the purpose for which the line is to be used once it has been blown into the conduit.This will aid the user in selecting the appropriate line for the job.
Knowing the approximate length of the conduit run will prevent selecting a line too short for the run. For example, if lightweight pull line is being placed in
3
4" conduit with a
estimated length of 195' to 200', select a 300'. Power Saver line package for the run. An alternate solution would be to use a
3
4" foam line carrier pulling bulk nylon line. Either
selection would insure an adequate length of line.
7.3 Selecting the Pull Line
It is not possible to foresee all conduit situations that may be encountered, therefore, the following is presented as a guide in selecting pull line. Determine which best fits the situation; whether the line is to be used for conduit identification, pulling in a larger line or rope, pulling in wire or for wire pulls at a later date.
1. Identification of a conduit termination where multiple
conduit runs originate from a single location. Recommended line: Power SaverLine Packages or Bulk Nylon Line.
2. Placing a line in the conduit for use at a later date.
Recommended line: Small conduit
1
2", 3⁄4" and 1" — Power SaverLine Packages, Bulk Nylon Line or PL232 Pull Line. Larger conduit 11⁄4" through 6" — Tag-Along™ Line Packages, PL232 or PL235.
3. Pulling in larger line, rope or steel winch cable. Recommended line: Small conduit same as above. Larger conduit PL232, PL235 or Poly Rope.
4. Pulling wire in conduit. Recommended line: PL232, PL235 or Poly Rope.
4
Blower Outlet
Power Unit
Vacuum Inlet
Recovery Compartment
Tool Storage Compartment
Figure 4. Blo-Vac™
Figure 3. B3000 Super Blower
Loading...