12
GB
Intended use
Liquids to be pumped
Please note
GARDENA Submersible Pump 10000 SL Inox Dirty Water Pump 18000 SP Inox
Welcome to the garden of GARDENA ...
Please read these operating instructions carefully and observe the notes given. Use the instructions to familiarise yourself with the pump, its correct use, and the notes on safety.
For safety reasons, children under 16 as well as persons not familiar with these operating instructions should not use this pump.
v Keep these operating instructions in a safe place.
1. Applications Range of Your GARDENA Pump
. . . . . . . . . . . . . . . . 12
2. For Your Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3. Initial Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
4. Operation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
5. Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
6. Trouble-Shooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
7. Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
8. Technical Data
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
9. Service
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
1. Applications Range of Your GARDENA Pump
GARDENA Pumps have been designed for private use around your house and garden. They are predominantly destinated for drainage after flooding, transfer of liquids, draining containers, tak­ing water from wells and shafts, draining boats and yachts as well as for water aeration and circulation for a limited period of time.
Liquids which can be handled by the GARDENA Pump are the fol­lowing: clean and contaminated water (max. particle size 10000 SL Inox = 5 mm / 18000 SP Inox = 38 mm), swimming pool water (prerequisite is the recommended dosage of additives) and soapy water.
The pumps are fully submersible (waterproof sealed) and can be immersed in the liquid down to a depth of 9 m.
The GARDENA Pumps are not designed for continuous operation (e.g. continuous circulating operation) in a pond. Your pump’s life will be shortened correspondingly by such operation. Corrosive, easily combustible or explosive substances (e.g. gasoline, petroleum, nitro thinner), fats, oils, salt-water and waste water of toilets and urinals must not be pumped. The temperature of the liquid handled should not exceed 35 °C.
Contents
Page 3
13
GB
2. For Your Safety
According to DIN VDE (German Electrical Engineers’ Associa­tion) 0100, submersible pumps and dirty water pumps may only be used in swimming pools, garden ponds, and fountains if the pump is operated via a residual-current device with a residual­current rating of 30 mA. The pump must not be operated when there are persons in the swimming pool or garden pond.
For safety reasons we recommend that you always operate the pump via a residual-current device (DIN VDE 0100-702 and 0100-738).
v Please contact your electrician. In Austria, according to ÖVE B/EN 60 555 part 1 to 3, pumps
which are used in swimming pools and garden ponds, and equipped with firm power cable should be fed via an ÖVE approved isolating transformer – rated voltage must not exceed 230 V.
In Switzerland mobile appliances which are used outdoors, must be connected via a residual-current device.
According to DIN VDE (German Electrical Engineers’ Associa­tion) 0620, mains power cables must not have a smaller cross­section than the rubber-sheathed cables of the designation H05 RNF (model 10000 SL Inox) or H07 RNF (model 18000 SP Inox). The cable length must be at least 10 m.
Data indicated on the type plate must match technical data of the mains supply.
v Take care that the electrical connections are made within
dry area, protected from flooding. Protect plug and power cable from heat, oil and sharp edges. v Don’t use the power cable for plugging off. The power cable or the float switch must not be used for mount-
ing or relocating the pump. For submerging or lifting/ securing the pump, fix a rope to the pump’s carrying handle.
Extension cables must meet the requirements of DIN VDE 0620.
v Before operating the pump, first make a visual check, if there
is any damage of the pump (esp. regarding power cable and
plug). v Observe the minimum water level and the max. delivery
height (see 8. Technical Data). A damaged pump must not be used. v In case of damage, please have the pump checked by our
GARDENA Service Centre.
During manual operation, the pump must be switched off as soon as all the liquid has been pumped away.
v Observe the pump at all times during manual operation.
Dry-running operation causes increased wear and is to be avoided. Therefore, in manual operation the pump must be immediately unplugged when water fails to flow.
Avoid running of the pump for more than 10 min. against closed delivery side of the pump.
Residual-current device
In Austria
In Switzerland
Mains power
Visual check
Manual operation
Notes on use
Page 4
14
GB
Sand and other abrasive substances cause increased wear and reduce the pump’s output.
Take care that the pump is located where the inlet openings at the suction base are obstructed neither completely nor partly.
Stand the pump on a brick if using in a pond.
When you purchase your pump the swivel feet are set to the flat suction position (1 mm).
v For normal operation, turn the feet 180° to 5 mm.
The pump is lifted 5 mm.
v Clear the outlet line before use.
The pump is automatically switched off on overheating by the built-in thermal motor protector. After having cooled down, the motor automatically switches on again (see 6. Trouble Shooting).
The automatic deaerating valve eliminates any air pockets in the pump. Air escapes by the vent bores
4
and air bubbles form under water. This is not a defect of your pump, but serves to deaerate the pump.
It may take several seconds for the air to escape when the pump is immersed for the first time.
Note on 10000 SL Inox
Thermal motor protector
Automatic deaerating valve
4
3. Initial Operation
13 mm (1/2 ”)
Hose diameter
15 mm(5/8) 25 mm (1) 38 mm (1 1/2”)
for 10000 SL Inox:
19 mm (3/4” )
Hose diameter for 18000 SP Inox:
38 mm (1 1/2) 50 mm (2” )
Hose connection of universal fitting
7
Hose connection Cut off topmost Do not cut off Cut off top two
nipple ata. any nipples. nipples at b.
The following connection kits are required for 13 mm to 19 mm connections:
13 mm (1/2 ): GARDENA Pump Connection Set, Art. No. 1750
or GARDENA Tap Connector, Art. No. (2)902,
and GARDENA Standard Hose Connector,
Art. No. (2)915
7
a b
For 10000 SL Inox :
Page 5
15
GB
15 mm (5/8 ): GARDENA Tap Connector, Art. No. (2)902,
and GARDENA Standard Hose Connector, Art. No. (2)916
19 mm (3/4): GARDENA Pump Connection Set, Art. No. 1752
or GARDENA Tap Connector, Art. No. 2802,
and GARDENA Standard Hose Connector,
Art. No. 2817.
Best results in delivery capacity are achieved when using 38 mm (1 1/2) hoses.
Best results in delivery capacity are achieved when using 50 mm (2) hoses.
The universal fitting
7
allows you to connect all the hoses listed
in the previous table.
1. Cut off nipples of the universal fitting 7, which are not needed,
to match the hose connection.
2. Screw the universal fitting
7
onto the pump.
3. Connect the hose to the universal fitting 7. We recommend that you secure 50 mm (2) and 38 mm (1 1/ 2” )
hoses additionally with a GARDENA Hose Clip Art. No. 7195 (for 50 mm) and Art. No. 7194 (for 38 mm).
Only for 10000 SL Inox:
For flat suction we recommend using a 13 mm (1/2) or 15 mm (5/8) hose.
Only for 13 mm (1/2” ) hose:
The universal fitting
7
can also be equipped with a GARDENA
Regulator Valve Art. No. 977 so that the contents of the out-
let line do not flow back through the pump after pumping. The Regulator Valve can be ordered from your GARDENA dealer.
4. Operation
The float switch 5turns the pump on automatically when the water level exceeds the cut-in height and the water is pumped out.
The float switch
5
turns the pump off again as soon as the water
level falls below the cut-out height.
1. Stand the pump on a firm surface
– or –
use a rope attached through the bore hole in the carrying handle 2to immerse the pump in a well or shaft.
During automatic operation, ensure that the float switch
5
can move freely.
2. Plug the power cable 1into a mains socket.
For 18000 SP Inox :
Connecting the hose:
7
1
2
5
3
Automatic operation:
Page 6
16
GB
Manual operation:
Only for 10000 SL Inox: Flat suction / Normal operation
Adjusting the Cut-in and Cut-out Height:
The maximum cut-in height and minimum cut-out height (see
8. Technical Data) can be adjusted. v Press the cable of the float switch
5
into an opening in the float
switch lock 3.
Do not select a cable length that is too long or short to ensure that the float switch can turn on and off properly.
The higher the opening of the float switch lock 3, the higher
the cut-in and cut-out height.
The shorter the length of cable between the float switch
5
and the float switch lock 3, the lower the cut-in height and the higher the cut-out height.
The cable length between the float switch 5and the float switch lock 3must always be at least 10 cm.
The pump remains in constant operation because the float switch is bypassed.
1. Push the float switch
5
onto the float switch lock 3with the
cable downward.
2. Stand the pump on a firm surface
– or –
use a rope attached through the bore hole in the carrying handle
2
to immerse the pump in a well or shaft.
3. Plug the power cable 1into a mains socket.
The residual water height (approx. 1 mm for 10000 SL Inox / 40 mm for 18000 SP Inox) is only reached during manual opera­tion since the float switch turns off the pump during automatic operation before this water level is reached.
V If the water height is lower than 3.5 cm, fill the pump
before operation over the universal fitting
7
with water.
Flat suction: Normal operation:
v
Turn the 3 swivel feet
8
v
Turn the 3 swivel feet
8
180°
to 1 mm.
180°
to 5 mm.
Flat suction up to 1 mm. Flat suction up to 5 mm.
The residual water level of approx. 1 mm is only reached during flat suction in the manual operation mode. If the water level is lower than 25 mm, you can accelerate flat suction by switching the pump off and on 2 to 3 times.
5
3
8
5
3
1
2
Page 7
17
GB
17
Flushing the Pump:
Cleaning the suction base and impeller:
5. Cleaning
The pumps are virtually maintenance-free. After having pumped chlorinated swimming pool water or other
liquids leaving residues, the pump should be rinsed with clear water.
Warning! Electric shock!
A Risk of injury due to electric shock.
V Disconnect the pump from the mains before clean-
ing the suction base and impeller.
1. Only for 10000 SL Inox: Unscrew the Phillips screw
A
and pull the suction base cover 0off the suction base 6.
2. Unscrew the 6 Phillips screws 8and pull the suction base
6
off the pump.
3. Clean suction base 6, impeller9and suction base cover
0
if necessary.
4. Reinstall the suction base
6
and screw in the Phillips screws 8.
5. Only for 10000 SL Inox: Insert the suction base cover 0into
the suction base 6and screw in the Phillips screwA.
Note for 10000 SL Inox:
It is often sufficient to simply remove the suction base cover
0
and clean the suction base cover 0and suction base 6.
For safety reasons a damaged impeller9can only be ex­changed by the GARDENA Service Centre.
6. Trouble-Shooting
Problem Probable cause Remedy
Pump is running, Air cannot escape, since v Open pressure line but doesn’t deliver. pressure line is closed. (e.g. kinked pressure pipe).
Air locks in the suction base. v Wait for max. 60 seconds
until the pump deaerates automatically over the vent valve. If necessary, switch off and start it again.
Impeller clogged. v Disconnect plug and clean
impeller (see 5. Cleaning).
When starting the pump, v Submerge pump deeper. water height falls below the min. water level.
Pump doesn’t start or Thermal overload switch has v Disconnect plug and clean suddenly stops during switched the pump off due impeller (see 5. Cleaning). operation. to overheating.
Observe max. media temper­ature of 35 °C.
9 6 0 A
8
9
6
8
Page 8
18
GB
Problem Probable cause Remedy
Pump doesn’t start or No power. v Check fuses and electric suddenly stops during connections. operation.
Dirt particles are jammed v Disconnect plug and clean in the suction base. suction base (see 5. Clean-
ing).
Pump runs, but output Suction base is clogged. v Disconnect plug and clean suddenly decreases. suction base (s. 5. Cleaning).
Only for 10000 SL Inox: Pump does not reach The suction base cover
0
v Disconnect the plug from
residual water height of is missing in the suction base. the mains and install the 1 mm during flat suction. suction base cover 0(see
5. Cleaning).
Attention!
Repairs on electrical parts should only be done by our GARDENA Service Centres.
If you have any problems with your Pump, please contact our Service.
7. Storing Your Pump
Store the pump away from frost before the first frost sets in.
The product must not be added to normal household waste. It must be disposed of in line with local environmental regulations.
8. Technical Data
Submersible Pump Dirty Water Pump
Type 10000 SL Inox (Art. 1784) 18000 SP Inox (Art. 1798) Rated power 380 W 1000 W Max. delivery capacity 10.000 l /h 18.000 l /h Max. pressure 0.7 bar 1.0 bar Max. delivery height 7 m 10 m Max. submersion depth 9 m 9 m Residual water level 1 mm 40 mm Contaminated water with
particle size of max. 5 mm 38 mm Power cable 10 m H05 RNF 10 m H07 RNF Pump connection 38 mm (1 1/2 )- / 25 mm (1)- 50 mm (2)- / 38 mm (1 1/2” )-
graduated nipple, option graduated nipple GARDENA Water hose Plug-in-system
Min. water level for operation 35 mm 100 mm Weight approx. 4.4 kg 7.1 kg
Frost-free storage
Disposal:
(in accordance with RL2002/ 96/ EC)
Page 9
19
GB
Performance characteristics
Submersible Pump Dirty Water Pump
Type 10000 SL Inox (Art. 1784) 18000 SP Inox (Art. 1798) Max. media temperature 35 °C 35 °C Mains voltage/
mains frequency 230 V / 50 Hz 230 V / 50 Hz Min. cut-in height 235 mm 340 mm Min./ max. cut-out height 30 mm / 135 mm 50 mm / 225 mm Noise level L
WA
1)
48 dB(A) 55 dB(A)
1) Measuring method according to EN 60335-1
The cut-in and cut-out height varies.
Only for 10000 SL Inox:
The residual water height (flat suction down to approx. 1 mm) is only reached during manual operation with the swivel feet
8
Cut-in / Cut-out height
m
10
8
6
4
2
0
0 5000 10000 15000 20000 l/h
bar
1,0
0,8
0,6
0,4
0,2
10000 SL Inox
18000 SP Inox
Warranty
9. Service
GARDENA guarantees this product for 2 years (from date of purchase). This guarantee covers all serious defects of the unit that can be proved to be material or manufacturing faults. Under warranty we will either replace the unit or repair it free of charge if the following conditions apply:
The unit must have been handled properly and in keeping
with the requirements of the operating instructions.
Neither the purchaser or a non-authorised third party have
attempted to repair the unit.
The impeller is a wearing part and is not covered by the guaran­tee.
This manufacturer’s guarantee does not affect the user’s existing warranty claims against the dealer/seller.
If you have any problems with your pump, please contact our Customer Service or return the defective unit together with a short description of the problem directly to one of the GARDENA Service Centres listed on the back of this leaflet.
Page 10
20
GB
EU Certificate of Conformity
The undersigned GARDENA Manufacturing · Hans-Lorenser-Str. 40 · D-89079 Ulm hereby certifies that, when leaving our factory, the units indicated below are in accordance with the
harmonised EU guidelines, EU standards of safety and product specific standards. This certificate becomes void if the units are modified without our approval.
Description of the units: Submersible Pump / Dirty Water Pump Types: 10000 SL Inox / 18000 SP Inox Art. No.: 1784 / 1798 EU directives: Machinery Directive 98/ 37/ EC
Electromagnetic Compatibility 89/ 336/EC Low Voltage Directive 73 /23/EC Directive 93/68/EC
Harmonised European standards: EN 292-1 Ulm, 04.06.2002
EN 292- 2 EN 60335-1 EN 60335-2-41
Year of CE marking : 2002 Thomas Heinl
Technical Dept. Manager
Product Liability
We expressly point out that, in accordance with the product liability law, we are not liable for any damage caused by our units if it is due to improper repair or if parts exchanged are not original GARDENA parts or parts approved by us, and, if the repairs were not carried out by a GARDENA Service Centre or an authorised specialist. The same applies to spare parts and accessories.
Page 11
Deutschland /Germany
GARDENA Manufacturing GmbH Service Center Hans-Lorenser-Straße 40 D-89079 Ulm Produktfragen: (+49) 731 490- 123 Reparaturen: (+49) 731 490- 290 service
@
gardena.com
Argentina
Argensem
®
S.A. Calle Colonia Japonesa s/n (1625) Loma Verde Escobar, Buenos Aires Phone: (+54) 34 88 4940 40 info
@
argensem.com.ar
Australia
Nylex Consumer Products 50-70 Stanley Drive Somerton, Victoria, 3062 Phone: (+61) 1800 658 276 spare.parts
@
nylex.com.au
Austria / Österreich
GARDENA Österreich Ges.m.b.H. Stettnerweg 11-15 2100 Korneuburg Tel.: (+ 43) 22 62 7 4545 36 kundendienst
@
gardena.at
Belgium
GARDENA Belgium NV/SA Sterrebeekstraat 163 1930 Zaventem Phone: (+32) 2 720 92 12 Mail: info
@
gardena.be
Brazil
Palash Comércio e Importação Ltda. Rua Américo Brasiliense, 2414 - Chácara Sto Antonio São Paulo - SP - Brasil ­CEP 04715-005 Phone: (+ 55) 11 5181-0909 eduardo
@
palash.com.br
Bulgaria
DENEX LTD. 2 Luis Ahalier Str.- 7th floor Sofia 1404 Phone: (+359) 2 95818 21 office
@
denex-bg.com
Canada
GARDENA Canada Ltd. 100 Summerlea Road Brampton, Ontario L6T 4X3 Phone: (+1) 905 79293 30 info
@
gardenacanada.com
Chile
Antonio Martinic y Cia Ltda. Cassillas 272 Centro de Cassillas Santiago de Chile Phone: (+56) 2 2010 708 garfar_cl
@
yahoo.com
Costa Rica
Compania Exim Euroiberoamericana S.A. Los Colegios, Moravia, 200 metros al Sur del Colegio Saint Francis - San José Phone: (+506) 297 6883 exim_euro
@
racsa.co.cr
Croatia
KLIS d.o.o. Stanciceva 79 10419 Vukovina Phone: (+ 385) 1 622777 0 gardena
@
klis-trgovina.hr
Cyprus
FARMOKIPIKI LTD P.O. Box 7098 74, Digeni Akrita Ave. 1641 Nicosia Phone: (+357) 22 75 4762 condam
@
spidernet.com.cy
Czech Republic
GARDENA spol. s r.o. Шнpskб 20a, и.p. 1153 627 00 Brno Phone: (+ 420) 800 100 425 gardena
@
gardenabrno.cz
Denmark
GARDENA Norden AB Salgsafdeling Danmark Box 9003 S-200 39 Malmö info
@
gardena.dk
Finland
Habitec Oy Martinkyläntie 52 01720 Vantaa
France
GARDENA PARIS NORD 2 69, rue de la Belle Etoile BP 57080 ROISSY EN FRANCE 95948 ROISSY CDG CEDEX Tél. (+33) 0826 101 455 service.consommateurs
@
gardena.fr
Great Britain
GARDENA UK Ltd. 27- 28 Brenkley Way Blezard Business Park Seaton Burn Newcastle upon Tyne NE13 6DS info
@
gardena.co.uk
Greece
Agrokip G. Psomadopoulos & Co. 33 A, Ifestou str. – Industrial Area 194 00 Koropi, Athens Phone: (+30) 210 66 20 225 service
@
agrokip.gr
www.agrokip.gr
Hungary
GARDENA Magyarország Kft. Késmárk utca 22 1158 Budapest Phone: (+36) 80 20 4033 gardena
@
gardena.hu
Iceland
Ó. Johnson & Kaaber Tunguhalsi 1 110 Reykjavik ooj
@
ojk.is
Ireland
Michael McLoughlin & Sons Hardware Limited Long Mile Road Dublin 12
Italy
GARDENA Italia S.p.A. Via Donizetti 22 20020 Lainate (Mi) Phone: (+39) 02.93.94.79.1 info
@
gardenaitalia.it
Japan
KAKUICHI Co. Ltd. Sumitomo Realty & Development Kojimachi BLDG., 8F 5-1 Nibanncyo, Chiyoda-ku Tokyo 102-0084 Phone: (+81) 33 264 4721 m_ishihara
@
kaku-ichi.co.jp
Luxembourg
Magasins Jules Neuberg Grand Rue 30 Boîte postale 12 L-2010 Luxembourg Phone: (+352) 40 14 01 info
@
neuberg.lu
Netherlands
GARDENA Nederland B.V. Postbus 50176 1305 AD ALMERE Phone: (+31) 36 52100 00 info
@
gardena.nl
Neth. Antilles
Jonka Enterprises N.V. Sta. Rosa Weg 196 P.O. Box 8200 Curaçao Phone: (+599) 9 76766 55 pgm
@
jonka.com
New Zealand
NYLEX New Zealand Limited Building 2, 118 Savill Drive Mangere, Auckland Phone: (+64) 9 2701806 lena.chapman
@
nylex.com.au
Norway
GARDENA Norden AB Salgskontor Norge Karihaugveien 89 1086 Oslo info
@
gardena.no
Poland
GARDENA Polska Sp. z o.o. Szymanów 9 d 05- 532 Baniocha Phone: (+48) 22 727 5690 gardena
@
gardena.pl
Portugal
GARDENA Portugal Lda. Recta da Granja do Marquês Edif. GARDENA Algueirão 2725-596 Mem Martins Phone: (+351) 21 922 85 30 info
@
gardena.pt
Romania
MADEX INTERNATIONAL SRL Soseaua Odaii 117-123, Sector 1, Bucureєti, RO 013603 Phone: (+ 40) 21 352 76 03 madex
@
ines.ro
Russia / Россия
АО АМИДА ТТЦ ул. Моcфилмовcкая 66 117330 Моcква Phone: (+ 7) 095 956 99 00 amida
@
col.ru
Singapore
Hy - Ray PRIVATE LIMITED 40 Jalan Pemimpin #02-08 Tat Ann Building Singapore 577185 Phone: (+65) 6253 2277 hyray
@
singnet.com.sg
Slovak Republic
GARDENA Slovensko, s.r.o. Panónska cesta 17 851 04 Bratislava Phone: (+421) 263 453 722 info
@
gardena.sk
Slovenia
Silk d.o.o. Brodiљиe 15 1236 Trzin Phone: (+ 386) 1 58093 00 gardena
@
silk.si
South Africa
GARDENA South Africa (Pty.) Ltd. P.O. Box 11534 Vorna Valley 1686 Phone: (+27) 11 315 02 23 sales
@
gardena.co.za
Spain
GARDENA IBÉRICA S.L.U. C/ Basauri, nº 6 La Florida 28023 Madrid Phone: (+34) 91 70805 00 atencioncliente
@
gardena.es
Sweden
GARDENA Norden AB Försäljningskontor Sverige Box 9003 200 39 Malmö info
@
gardena.se
Switzerland / Schweiz
GARDENA (Schweiz) AG Bitziberg 1 8184 Bachenbülach Phone: (+41) 848 800 464 info
@
gardena.ch
Turkey
GARDENA / Dost Diþ Ticaret Mümessillik A.Þ. Sanayi Çad. Adil Sokak No.1 Kartal - Ýstanbul Phone: (+ 90) 216 38 93 939 info
@
gardena-dost.com.tr
Ukraine / Украина
ALTSEST JSC 4 Petropavlivska Street Petropavlivska Borschahivka Town Kyivo Svyatoshyn Region 08130, Ukraine Phone: (+380) 44 459 57 03 upyr
@
altsest.kiev.ua
USA
Melnor Inc. 3085 Shawnee Drive Winchester, VA 22604 Phone: (+1) 540 722-9080 service_us
@
melnor.com
1784- 20.960.03 /0606
©
GARDENA Manufacturing GmbH D- 89070 Ulm http: //www.gardena.com
84
Loading...