Gardena 3000/4 eco, 1753 Operating Instructions Manual

3000/4 eco Art. 1753
D Betriebsanleitung
Hauswasserwerk
GB Operating Instructions
Pressure Tank Unit
F Mode d’emploi
Groupe de surpression
Hydrofoorpomp
S Bruksanvisning
Hydroforpump
DK Brugsanvisning
Husvandværk
FI Käyttöohje
Painevesiyksikkö
N Bruksanvisning
Trykktank
I Istruzioni per l’uso
Autoclave
E Instrucciones de empleo
Estación de Bombeo con Calderín
P Manual de instruções
Bomba doméstica
PL Instrukcja obsługi
Zestaw hydroforowy
H Használati utasítás
Házi vízellátó
CZ Návod k obsluze
Domácí vodárna
SK Návod na obsluhu
Domáca vodáreň
GR Οδηγίες χρήσης
Πιεστικό με βαρέλι
RUS Инструкция по эксплуатации
Станция бытового водоснабжения автоматическая
SLO Navodilo za uporabo
Hišna vodna črpalka
HR Upute za uporabu
Kućni hidroforska pumpa
SRB Uputstvo za rad BIH Kućna hidroforska pumpa
UA Інструкція з експлуатації
Домова водопровідна станція
RO Instrucţiuni de utilizare
Hidrofor cu rezervor
TR Kullanma Kılavuzu
Konut Suyu Tertibatı
BG Инструкция за експлоатация
Хидрофорна уредба с разширителен съд
AL Manual përdorimi
Impiant uji për shtëpi
EST Kasutusjuhend
Hüdrofooriga veeautomaat
LT Eksploatavimo instrukcija
Siurblys su slėgio rezervuaru
LV Lietošanas instrukcija
Spiedtvertnes ierīce
LV LT EST AL BG TR RO UA
SRB
BIH
HR SLO
RUS
GR SK CZ H PL P E I N FI DK S NL F GB D
GARDENA Pressure Tank Unit 3000/4 eco
Translation of the original German operating instructions.
Please read the operating instructions carefully and observe the notes given. Use these operating instructions to familiarise yourself with the product, the proper use and the safety instructions.
Never operate the product when you are tired, ill or under the influence of alcohol, drugs or medicine.
This product may be used under supervision, or if instruction regarding the safe use of the product has been provided and the resulting dangers have been understood, by children aged 8 and above, as well as by persons with physical, sensory or mental disabilities or a lack of experience and knowledge. Children must not be allowed to play with the product. Cleaning and user maintenance must not be performed by children without supervision. The use of this product by young people under the age of 16 is not recommended.
v Keep these operating instructions in a safe place.
Contents: 1. Area of application of your GARDENA Pressure Tank Unit. . 12
2. Safety Instructions .................................13
3. Initial Operation ....................................14
4. Operation ........................................16
5. Storage ..........................................17
6. Maintenance ......................................17
7. Trouble-Shooting ..................................18
8. Available accessories ...............................20
9. Technical Data ....................................20
10. Service / Warranty ..................................21
1. Area of application of your GARDENA Pressure Tank Unit
Correct use: The GARDENA Pressure Tank Unit is intended for private use in the
house and garden; it is not intended for operation of watering equipment and accessories in public gardens.
Liquids pumped: The GARDENA Pressure Tank Unit can be used to deliver
rainwater, tap water and chlorinated swimming pool water.
Please note:
The GARDENA Pressure Tank Unit is not suitable for con­tinuous operation (e.g. industrial use, continuous circulation operations). Corrosive, easily combustible, aggressive or explosive liquids (such as gasoline, petroleum or nitro thinner), saltwater and food must not be pumped. The temperature of the liquid must not exceed 35 °C.
12
GB
2. Safety Instructions
Electrical safety
DANGER! Electric shock!
Risk of injury due to electric shock!
v Always unplug your Pressure Tank Unit
before filling, after operation, when trou­bleshooting and before carrying out any maintenance work.
Caution: Pursuant to DIN VDE 0100-702, the use of the pump is only permissible if the pump is operated via a residual-current device (FI switch).
The pump must be located on solid, even ground, protected from flooding. Take care that the pump cannot fall into water.
As an additional safety device an authorised safety switch can be used.
v Please ask your electrician for his advice. Data indicated on the type plate must match
the technical data of the mains supply. Pursuant to DIN VDE 0620 the power cable
as well as any extension cable must not have a smaller diameter than rubber sheathed cables described with letter symbols H05RN-F.
Protect the power cable from heat, oil and sharp edges.
Do not use the power cable for carrying the pump or for unplugging.
v If the supply cord is damaged, it must be
replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
In Austria
In Austria the electrical connection must satisfy the ÖVE-EM 42, T2 (2000)/1979 § 22 to § 2022.1. This requires that pumps used for swimming pools and garden ponds may only be powered through an isolating trans­former.
v Please ask your electrician for his advice.
In Switzerland
In Switzerland portable devices that are used outdoors must be connected through an earth leakage circuit breaker. Mobile appliances that are used outdoors must be connected via aresidual-current device.
General Information
Risk of injury due to hot water!
If the pressure switch is defective or if the water supply on the intake side of the pump fails, any water remaining in the pump may heat up, generating a risk of injuries caused by hot water on leakage.
The pump is equipped with a temperature fuse, which switches off the pump at high water temperatures (approx. 65 °C).
v After temperature-related cut-out,
disconnect the pump from the mains via the main circuit breaker, let the water cool (approx. 10 – 15 min.) and secure the water supply on the intake side before putting into operation again.
v Before operating the pressure tank unit, first
make a visual check to ensure there is no damage to the pressure tank unit (especially regarding power cable and plug).
A damaged pressure tank unit must not be used.
v In case of damage, please have the
pressure tank unit checked by our GARDENA Service Centre or by an authorised electrician.
Protect the pump from rain. Do not use the pressure tank unit in a wet or moist area.
In order to avoid dry-running of the pressure tank unit, take care that the end of the suction hose is always submerged into the liquid.
The pressure tank unit must not be run dry nor with the stopcock in the suction pipework closed.
v Before each operation, fill the pressure tank
unit to overflowing with approx. 2 to 3 l of the liquid to be pumped!
Sand and other abrasive substances in the liquid cause increased wear and reduce the pump’s output.
When using the pump for domestic water supply, please adhere to the local water and sewerage regulations. In addition observe the regulations of DIN 1988.
v
If necessary contact your local water authority.
13
GB
3. Initial Operation
Installing the Pressure Tank Unit:
The installation position must be firm and dry, and permit a secure mounting for the pressure tank unit.
v Install the Pressure Tank Unit at a safe distance from the
pumping medium.
The pump must be installed in a location with low air humidity and sufficient ventilation in the area of the ventilation slots. It must be at a distance of at least 5 cm from the walls. No dirt contamination (e. g. sand or earth) may be sucked in through the ventilation slots.
Fixed installation of the Pressure Tank Unit:
3
1
2
v The Pressure Tank Unit can be screwed with all 4 feet 2 onto
asolid surface
1
.
Alternatively, spring mounted feet (Art. 1753-00.901.00) for low vibration and quiet running are available as accessories via the GARDENA Service.
Install the pressure tank unit so that there is room to place a suitably sized drainage tray under the drain screw
3
to allow
the unit or system to be drained. If possible, install the unit higher than the surface of the water to
be pumped. If this is not possible, install a vacuum-resistant valve between the unit and the suction hose, for example for cleaning the integrated filter.
If the pump is permanently installed indoors for domestic water supply, the Pressure Tank Unit should not be connected to the domestic water pipework with rigid pipes but with flexible tubing, to reduce noise and to avoid damage to the pump caused by pressure blows.
If the system is being installed permanently, please fit suitable valves on both the intake and delivery sides. This is important e. g. for maintenance and cleaning work or if the system is being shut down.
The connection pieces on the intake and delivery sides may only be tightened by hand.
Warning! This unit makes an electromagnetic field while it operates. This field may under some con ditions interfere with active or pas­sive medical implants. To decrease the risk of conditions that can possibly injure or kill, we recommend persons with medical implants to speak with their physician and the medical implant manufacturer before operating.
Warning! Keep toddlers away when you assemble the unit. Small parts can be easily swallowed. There is also a risk that the poly­bag can suffocate toddlers.
14
GB
Connect the hose to the suction side:
Art. 1723 / Art. 1724
4
5
6
A vacuum-tight suction hose must be used e. g.: – GARDENA Suction Unit Art. no. 1411 / 1418 / 1412 or – GARDENA Bore Hole Suction Hose Art. no. 1729.
Do not use any water hose snap connection system components on the intake side!
v Connect the suction hose
5
with the intake side
connection 6 of the pump.
Connect the suction hoses
5
without a threaded connector via
a connection piece (e.g. Art. no. 1723/1724) 4 with the intake side connection and screw in place so that they are airtight.
To reduce the pump repriming time, we recommend using a suction hose with backflow preventer, which prevents the suction hose emptying automatically when the Pressure Tank Unit is switched off.
For suction heights exceeding 4 m also secure the suction hose
5
(e. g. by fastening it to a wooden post) to relieve the pump of the weight of the suction hose.
If very fine dirt is present in the pumping medium, we recommend the use of a GARDENA Pump Preliminary Filter Art. no. 1730 / 1731.
Connect hose to the output side:
8
7
Note:
Use pressure-tight GARDENA hoses, 19 mm (3/4") in diameter, in connection with the GARDENA Quick-Release Threaded Connector with 33.3 mm (G1) internal thread, Art. no. 7109, and the GARDENA Suction and High Pressure Connector, Art. no. 7120, for 19 mm (3/4") hoses and a GARDENA Hose Clip, Art. no. 7192.
Under no circumstances use these hoses on the suction side.
v Connect delivery hose 7 to the delivery side connection 8. v Tip: If permanent pipes are installed, they must be laid at an
ascending angle in order to allow the water to flow back into the pump on the pressure side.
15
GB
4. Operation
Starting the Pressure Tank Unit:
FILL
RUN
q
0
e
q
w
FILL
RUN
q
DANGER! Electric shock! v Before filling the pump, unplug the equipment from
the mains. WARNING! Pump running dry! v Fill the pump to the overflow (approx. 2 to 3 l) with
water each time before the pump is switched on,
soit does not run dry.
1. Unscrew the cover
0
of the filter chamber by hand.
2. Turn the rotary switch
q
to FILL.
The integrated non-return valve will open.
3. Open the air bleed
w
.
4. Open any valves in the delivery line (watering accessories, water stop, etc.) and drain off any residual water in the delivery hose so that the air can escape during filling and priming.
5. Slowly pour pumping medium (approx. 2 to 3 l) through the filler neck
e
until water emerges from the air bleed w.
6. Screw the filter chamber cover
0
closed again, turning by hand
until it stops.
7. Close venting
w
and turn rotary switch q to RUN.
8. Insert the mains plug into a 230 V mains socket. CAUTION! The pump will start immediately!
Once the maximum pressure is reached the pump will switch off automatically. When the pressure falls below the minimum value due to water being drawn off, the pump will switch on again automatically.
The maximum self-priming head of 8 m is only achieved if the pump is filled until it overflows from the filler connection
e
and the delivery hose is held high enough during self-priming so that no water can escape from the pump via the delivery hose. It is not necessary to hold up the delivery hose if filled suction hoses with backflow preventer are used.
ECO switch:
EC
O MAX
r
In order to save energy (up to 15 %), the cut-out pressure on the pump can, depending on the individual application, be regulated between ECO and MAX (the pressure difference between ECO and MAX totals approx. 1 bar).
v Turn the ECO rotary switch
r
to the required position.
Note on the use of sprinklers: Depending on the flow rate of the sprinkler, an uneven watering