Garador GaraMatic 9 Instructions For Fitting, Operating And Maintenance

TR10A148-F RE / 04.2017
EN
Instructions for Fitting, Operating and Maintenance
Garage door operator
4 mm
T 30
Ø 10 mm
Ø 5 mm
A
B
2
TR10A148-F RE / 04.2017
Contents
A Articles supplied ..................................................... 2
B Tools needed for fitting .......................................... 2
ENGLISH
1 About these instructions ........................................ 4
1.1 Further applicable documents .................................. 4
1.2 Warnings used .......................................................... 4
1.3 Definitions used ........................................................ 4
1.4 Symbols used ........................................................... 4
1.5 Abbreviations used ................................................... 5
2
2.1 Intended use ............................................................. 5
2.2 Non-intended use ..................................................... 5
2.3 Fitter qualification ..................................................... 5
2.4 Safety instructions for fitting, maintenance,
2.5 Safety instructions for fitting ..................................... 5
2.6 Safety instructions for initial start-up and for
2.7 Safety instructions for using the hand transmitter .... 6
2.8 Approved safety equipment...................................... 6
3 Fitting ....................................................................... 7
3.1 Inspect door / door system ....................................... 7
3.2 Clearance required.................................................... 7
3.3 Fitting the garage door operator ............................... 7
3.4 Fitting the boom ...................................................... 16
3.5 Determining the end-of-travel positions ................. 21
3.6 Emergency release.................................................. 23
3.7 Fixing the warning sign ........................................... 23
4 Electrical connection ............................................ 24
4.1 Connecting terminals .............................................. 24
4.2 Connecting additional components / accessories .... 24
5 Setting DIL switches ............................................. 28
5.1 Close limit switch reporting .................................... 28
5.2 Pre-warning time .................................................... 28
5.3 External light ........................................................... 28
5.4 Automatic timer ...................................................... 28
5.5 Door type (soft stop) ............................................... 28
5.6 Static current circuit / stop with self-testing ............ 28
5.7 Maintenance display ............................................... 28
5.8 DIL switch functions ............................................... 29
6 Initial start-up ........................................................ 30
6.1 Teaching in the operator ......................................... 30
6.2 Adjusting the forces ................................................ 31
6.3 Forces ..................................................................... 32
7 Hand transmitter HSE4BiSecur ......................... 32
7.1 Description of the hand transmitter ........................ 33
7.2 Inserting / changing the battery ............................... 33
7.3 Hand transmitter operation ..................................... 33
7.4 Inheriting / transmitting a radio code ....................... 33
7.5 Hand transmitter reset ............................................ 33
Safety instructions ........................................... 5
repairs and disassembly of the door system ............ 5
operation ................................................................... 6
7.6 LED display ............................................................. 33
7.7 Cleaning the hand transmitter ................................ 33
7.8 Disposal .................................................................. 33
7.9 Technical data ......................................................... 34
7.10 EU declaration of conformity for the hand
transmitter ............................................................... 34
8 Radio receiver ....................................................... 34
8.1 Integrated radio module ......................................... 34
8.2 External receiver ..................................................... 35
8.3 EU Declaration of Conformity for Receivers ........... 35
9 Operation ............................................................... 35
9.1 Instructing users ..................................................... 36
9.2 Function check ....................................................... 36
9.3 Normal operation .................................................... 36
9.4 Behaviour during a power failure
(without an emergency battery) .............................. 37
9.5 Behaviour after the power returns
(without emergency battery) ................................... 37
10 Inspection and maintenance ............................... 37
10.1 Tension of the toothed belt ..................................... 37
10.2 Checking safety reversal / reversing ........................ 37
10.3 Replacement bulb ................................................... 38
11 Deleting door data ................................................ 38
12 Deleting all radio codes ........................................ 38
13 Optional accessories ............................................ 39
14 Dismantling and disposal ..................................... 39
15 Warranty conditions ............................................. 39
16 EC / EU Declaration of Conformity /
Declaration of Incorporation ................................ 39
17 Technical data ....................................................... 40
18 Display of messages and errors .......................... 40
18.1 Operator light messages......................................... 40
18.2 Display of errors / warnings / information ................ 41
19 Overview of DIL switch functions........................ 42
Dissemination as well as duplication of this document and the use and communication of its content are prohibited unless explicitly permitted. Noncompliance will result in damage compensation obligations. All rights reserved in the event of patent, utility model or design model registration. Subject to changes.
TR10A148-F RE / 04.2017
3
ENGLISH
Dear Customer, We are delighted that you have chosen a quality product from
our company.

1 About these instructions

These instructions are original operating instructions as outlined in the EC Directive2006/42/EC. Read through all of the instructions carefully, as they contain important information about the product. Pay attention to and follow the instructions provided, particularly the safety instructions and warnings.
Please keep these instructions in a safe place and make sure that they are available to all users at all times.

1.1 Further applicable documents

The following documents for safe handling and maintenance of the door system must be placed at the disposal of the end user:
• These instructions
• The enclosed test manual
• The garage door operating instructions

1.2 Warnings used

The general warning symbol indicates a danger that
can lead to injury or death. In the text, the general warning symbol will be used in connection with the caution levels described below. In the illustrated section, an additional instruction refers back to the explanation in the text.
DANGER
Indicates a danger that can immediately lead to death or serious injuries.
Learning runs
Door runs in which the travel and the forces needed for moving the door are taught in.
Normal operation
Door travel with the taught-in travel distances and forces.
Reference run
Door cycle towards the OPEN end-of-travel position in order to set the home position.
Reversal limit
If a safety device is activated, the door moves into the opposite direction (safety reversal) up to the reversal limit shortly before the Close end-of-travel position. If this limit is passed, no reversal occurs to ensure that the door reaches the end-of-travel position without disrupting travel.
Safety reversal / reversing
Door travel in the opposite direction when the safety device or power limit is activated.
Travel
The distance the door takes to move from the Open end-of-travel position to the Close end-of-travel position.
Pre-warning time
The time between the travel command (impulse) and the start of travel.

1.4 Symbols used

The illustrated section shows how to fit the operator on a sectional door. Deviations for fitting with an up-and-over door are also shown. For this purpose, the following letters are assigned to the figures:
WARNING
Indicates a danger that can lead to death or serious injuries.
CAUTION
Indicates a danger that can lead to minor or moderate injuries.
ATTENTION
Indicates a danger that can lead to damage or destruction of the product.
1.3 Definitions used
Hold-open phase
Waiting phase at the Open end-of-travel position before the door closes with an automatic timer
Automatic timer
Automatic closing of the door after a set time has elapsed and after reaching the Open end-of-travel position.
DIL switches
Switches on the control circuit board for setting the control.
Impulse sequence control
With each push of the button, the door is started against the previous direction of travel or the motion of the door is stopped.
4
a = Sectional door b = Up-and-over door
All specified dimensions in the illustrated section are in [mm].
Symbols:
See text section
2.2
In the example, 2.2 means: Seetextsection, section2.2
Important advice to prevent injury to persons and damage to property
High exertion of force
TR10A148-F RE / 04.2017
ENGLISH
Check for smooth running
Use protective gloves
Factory setting
Slow flashing
Fast flashing

1.5 Abbreviations used

Colour code for cables, single conductors and components
The abbreviations of the colours for identifying the cables, conductors and components comply with the international colour code according to IEC757:
WH White BN Brown GN Green YE Yellow
Article designations
HE3BiSecur 3-channel receiver IT1 Internal push button with impulse button IT 1b Internal push button with illuminated
impulse button EL101 One-way photocell EL301 One-way photocells STK Wicket door contact PR1 Option relay HSE4BiSecur 4-button hand transmitter HNA 18 Emergency battery
2 Safety instructions
ATTENTION:
IMPORTANT SAFETY INSTRUCTIONS. FOR THE SAFETY OF PERSONS, IT IS IMPORTANT TO
COMPLY WITH THE FOLLOWING INSTRUCTIONS. THESE INSTRUCTIONS MUST BE KEPT.

2.1 Intended use

The garage door operator is intended exclusively for impulse operation of spring-compensated sectional and up-and-over doors in the private / non-commercial sector.
Note the manufacturer's specifications regarding the door and operator combination. Potential hazards as outlined in DINEN13241-1 are avoided by construction and fitting according to our guidelines. Door systems that are located in a public area and which only have one protective device, such as a power limit, may only be operated under supervision.
The garage door operator is designed for operation in dry areas.

2.2 Non-intended use

Use in the commercial sector is prohibited. The operator must not be used for doors without a safety
catch.
2.3 Fitter qualification
Only correct fitting and maintenance in compliance with the instructions by a competent / specialist company or a competent / qualified person ensures safe and flawless operation of the system. According to EN12635, a specialist is a person with suitable training, specialist knowledge and practical experience sufficient to correctly and safely fit, test, and maintain a door system.
2.4 Safety instructions for fitting, maintenance, repairs and disassembly of the door system
DANGER
Compensating springs are under high tension
See warning in section3.1
WARNING
Danger of injury due to unexpected door travel
See warning in section10
Fitting, maintenance, repairs and disassembly of the door system and garage door operator must be performed by a specialist.
In the event of a failure of the garage door operator, a specialist must be commissioned immediately to perform an inspection or carry out repairs.
2.5 Safety instructions for fitting
The specialist carrying out the work must ensure that installation is conducted in compliance with the prevailing national job safety rules and regulations and those governing the operation of electrical equipment. In the process, the relevant national guidelines must be observed. Potential hazards as outlined in DINEN13241-1 are avoided by construction and fitting according to our guidelines.
The garage ceiling must guarantee secure fastening of the operator. For ceilings which are too high or too light, the operator must be fastened with additional struts.
TR10A148-F RE / 04.2017
5
ENGLISH
WARNING
Unsuitable fixing material
See warning in section3.3
Danger to life from the pull rope
See warning in section3.3
Danger of injury due to unwanted door travel
See warning in section3.3

2.6 Safety instructions for initial start-up and for operation

DANGER
Mains voltage
Contact with the mains voltage presents the danger of a deadly electric shock.
For that reason, observe the following warnings under all circumstances:
Electrical connections may only be made by a qualified electrician.
The on-site electrical installation must conform to the applicable protective regulations (230 / 240VAC, 50 / 60Hz)!
If the mains connection cable is damaged, itmustbe exchanged by a qualified electrician toavoiddanger.
Disconnect the mains plug and the plug of the emergency battery whenever performing work on the door system.
Safeguard the door system against being switched on again without authorisation.
WARNING
Danger of injury during door travel
See warning in section9
Danger of injury by fast-closing door
See warning in section9.2.1
ATTENTION
External voltage at the connecting terminals
External voltage on the connecting terminals of the control will destroy the electronics.
Do not apply any mains voltage (230 / 240VAC) to the connecting terminals of the control.

2.7 Safety instructions for using the hand transmitter

WARNING
Danger of injury during door travel
See warning in section7
CAUTION
Danger of injuries due to unintended door travel
See warning in section7
CAUTION
Danger of burns from the hand transmitter
See warning in section7

2.8 Approved safety equipment

The following functions or components, where available,meet cat. 2, PL “c” in accordance with ENISO13849-1:2008 and were constructed and testedaccordingly:
• Internal power limit
• Tested safety equipment
If such properties are needed for other functions orcomponents, this must be tested individually.
WARNING
Danger of injuries due to faulty safety equipment
See warning in section6
CAUTION
Danger of crushing in the boom
See warning in section9
Danger of injury from the cord knob
See warning in section9
Danger of injuries due to the hot lamp
See warning in section9
Danger of injury due to the force value being set too high
See warning in section6.3
Danger of injury resulting from uncontrolled door movement in the Close direction if one of the counterbalance springs breaks and the slide carriage is released.
See warning in section9
6
TR10A148-F RE / 04.2017
ENGLISH

3 Fitting

ATTENTION:
IMPORTANT INSTRUCTIONS FOR SAFE FITTING. OBSERVE ALL INSTRUCTIONS, INCORRECT FITTING COULD RESULT IN SERIOUS INJURIES.

3.1 Inspect door / door system

DANGER
Compensating springs are under high tension
Serious injuries may occur while adjusting or loosening the compensating springs!
For your own safety, only have a specialist conduct work on the door compensating springs and, if necessary, maintenance and repair work!
Never try to replace, adjust, repair or reposition the compensating springs for the counterbalance of the door or the spring mountings yourself.
In addition, check the entire door system (joints, door bearings, cables, springs and fastenings) for wear and possible damage.
Check for the presence of rust, corrosion, and cracks.
A malfunction in the door system or an incorrectly aligned door can cause serious injuries!
Do not use the door system if repair or adjustment work must be conducted!
The construction of the operator is not designed for operation with sluggish doors, i.e. doors that can hardly or not at all be opened or closed manually.
The door must be in a flawless mechanical condition, as well as correctly balanced, so that it can be easily operated by hand (EN12604).
Lift the door by approx. one metre and let it go. The door should stay in this position and neither move downward nor upward. If the door does move in either direction, there is a danger that the compensating springs / weights are not properly adjusted or are defective. In this case, increased wear and malfunctioning of the door system can be expected.
Check whether the door can be opened and closed correctly.

3.2 Clearance required

The clearance between the highest point of door travel and the ceiling (even when opening the door) must be at least 30mm. For doors under thermal loads, the operator is to be fitted 40mm higher if applicable.
If the clearance is smaller, the operator can also be mounted behind the opened door if enough space is available. In this case, an extended fitting bracket (ordered separately) must be used.
The garage door operator can be arranged up to max. 500mm off-centre.
The electrical outlet should be fitted approx. 500mm from the operator head.
Check these dimensions!

3.3 Fitting the garage door operator

WARNING
Unsuitable fixing material
Use of unsuitable fixing material may mean that the operator is insecurely attached and could come loose.
The fitter must check the suitability of the provided fixing material (plugs) for use in the intended fitting location; other fixing material must be used if the provided material is suitable for concrete (≥B15) but is not officially approved (see Figures1.6a / 1.8b / 2.4).
WARNING
Danger to life from the pull rope
A running rope may lead to strangulation.
Remove the rope while fitting the operator (seeFigure1.3a).
WARNING
Danger of injury due to unwanted door travel
Incorrect assembly or handling of the operator may trigger unwanted door travel that may result in persons or objects being trapped.
Follow all the instructions provided in this manual.
Incorrectly fitted control devices (e.g. buttons) may trigger unwanted door travel. Persons or objects may be jammed as a result.
Install control devices at a height of at least 1.5m (out of the reach of children).
Fit permanently installed control devices (such as buttons, etc.) within sight of the door, but away from moving parts.
ATTENTION
Damage caused by dirt
Drilling dust and chippings can lead to malfunctions.
Cover the operator during drilling work.
In order to fully comply with the TTZ break-in resistance guideline for garage doors, the cord knob on the slide carriage must be removed.
TR10A148-F RE / 04.2017
7
ENGLISH
8
TR10A148-F RE / 04.2017
≥ 30
≥ 70
Note section 3.2. –Clearance required
1. Completely disassemble the mechanical door locking.
2. With an off-centre reinforcement profile, fit the link bracket on the nearest reinforcement profile to the left or right (see Figure1a).
ENGLISH
TR10A148-F RE / 04.2017
9
ENGLISH
10
TR10A148-F RE / 04.2017
1/2 1/2
1.5a
Ø 5
B
B
B
B
3. For sectional doors with central
NOTE:
Not illustrated in Figure1.5a: use the 5 × 35 woodscrews from the door accessory pack (hole Ø 3mm) for timberdoors.
ENGLISH
door locking, fit the lintel joint and link bracket off-centre (max.500mm).
TR10A148-F RE / 04.2017
11
1
/
2
1
/
2
A
113-180
60
Ø 10
EPU/LTE/LPU/LTH 40
138-180
60
1.6a
A
55-76
60
EPU/LTE/LPU/LTH 40
60
50-80
A
40-80
60
EPU/LTE/LPU/LTH 40
ENGLISH
12
TR10A148-F RE / 04.2017
Note section 3.2. –Clearance required
1. Render the mechanical door lockings inoperable (seeFigure1.3b).
ENGLISH
TR10A148-F RE / 04.2017
13
ENGLISH
2. Render the mechanical door lockings inoperable (seeFigures1.4b / 1.5b). For door models not covered here, block the catches on site.
3. In a deviation from the Figures1.6b / 1.7b: The lintel joint and link bracket must be attached off-centre for up-and-over doors with ornamental iron door handles.
14
TR10A148-F RE / 04.2017
NOTE:
With N80 doors with timber infill, use the bottom holes on the lintel joint for fitting.
ENGLISH
TR10A148-F RE / 04.2017
15
ENGLISH

3.4 Fitting the boom

NOTE:
Only use the booms recommended byus for the garage door operators –depending on the respective application (see product information).
16
TR10A148-F RE / 04.2017
1. Press the green button and move
the slide carriage approx. 200mm towards the centre of the rail (seeFigure2.1). This is no longer possible once the end stops and operator have been fitted.
ENGLISH
TR10A148-F RE / 04.2017
17
ENGLISH
NOTE:
A second suspension is recommended with divided rails (available under accessories) (see Figure2.5).
18
TR10A148-F RE / 04.2017
NOTE:
Depending on the track application, the installation direction of the fitting bracket must be taken into account.
ENGLISH
TR10A148-F RE / 04.2017
19
ENGLISH
NOTE:
Depending on the door type, the installation direction of the fitting bracket must be taken into account.
20
TR10A148-F RE / 04.2017
To prepare for manual operation
Pull on the cord of the mechanical release (see Figure4).
3.5 Determining the
end-of-travel positions
If the door cannot be easily moved into the desired Open or Closed end-of-travel position.
Note section3.1!
3.5.1 Fitting the Open end stop
1. Loosely insert the end stop in the
boom between the slide carriage and operator.
2. Push the door into the Open
end-of-travel position by hand.
3. Fix the end stop.
NOTE:
In case the door does not reach the complete passage height in the end-of-travel position, the end stop can be removed so that the integrated end stop (on the operator head) is used.
ENGLISH
TR10A148-F RE / 04.2017
21
ENGLISH
3.5.2 Fitting the Close end stop
1. Loosely insert the end stop in the
boom between the slide carriage and door.
2. Push the door into the Close end-of-travel position by hand.
3. Move the end stop by approx. 10mm in the Close direction and fix the end stop.
To prepare for automatic operation
Push the green button on the slide carriage (see Figure6).
Move the door by hand until the slide carriage snaps into the belt lock.
Note the safety instructions in section9 –Danger of crushing in the boom
22
TR10A148-F RE / 04.2017
3.5.3 Fitting the operator head
Fix the operator head (see Figure7).
Note the safety instructions in section9 –ATTENTION

3.6 Emergency release

The cord knob for mechanical release may not be installed at a height greater than 1.8m from the garage floor. The cord may need to be extended on-site, depending on the height of the garage door.
When extending the cord, please make sure that the cord cannot become caught on a roof carrier system or any other vehicle protrusions.
An emergency mechanical release is required in garages without a second entrance in order to prevent users from locking themselves during a power failure; this must be ordered separately.
Check the emergency release for proper function every month.

3.7 Fixing the warning sign

Fix the crushing warning sign in a prominent, cleaned and degreased place, for example near to the permanently installed button for moving the operator.
ENGLISH
TR10A148-F RE / 04.2017
23
ENGLISH

4 Electrical connection

Note the safety instructions in section2.6 – Mains voltage External voltage at the connecting
terminals
To prevent malfunctions:
Duct the operator's connection cables (24VDC) in an installation system that is separate from other supply lines (230VAC).

4.1 Connecting terminals

All connecting terminals can have multiple assignments (see Figure10):
• Minimum thickness: 1 × 0.5mm
• Maximum thickness: 1 × 2.5mm
2
2
4.2 Connecting additional
components / accessories
NOTE:
Loading of the operator by all accessories: max. 100mA. See the figures for component power consumption.
24
TR10A148-F RE / 04.2017
ENGLISH
4.2.1 External radio receiver
See Figure11
and section8
*
Insert the plug of the receiver in the corresponding socket.
4.2.2 External impulse button*
See Figure12 / 13
One or more buttons with normally open contacts (volt-free), such as internal push buttons or key switches, can be connected in parallel.
* Accessory; not included in the standard
equipment!
TR10A148-F RE / 04.2017
25
ENGLISH
4.2.3 External impulse button for
partial opening*
See Figure14
One or more buttons with normally open contacts (volt-free), such as key switches, can be connected in parallel.
4.2.4 2-wire photocell* (dynamic)
See Figure15
NOTES:
• Follow the fitting instructions when mounting photocells.
• The photocell must be connected before the learning run.
• A new learning run is required if the photocell is removed.
4.2.5 Tested wicket door contact
Connect wicket door contacts that switch to ground (0V) as shown in Figure16.
NOTES:
• The wicket door contact must be connected before the learning run.
• A new learning run is required if the wicket door contact is removed.
Door cycles are immediately halted and permanently prevented when the wicket door contact is opened.
*
* Accessory; not included in the standard
equipment!
26
TR10A148-F RE / 04.2017
19
18
25 mA
A
B C
+-
52120
24V
0V
.5
.6
.8
5
PR 1
U
17
PR 1
ENGLISH
4.2.6 Option relay PR1
See Figure17
Option relay PR1 is required to connect an external lamp or warning light.
4.2.7 Emergency battery HNA18*
See Figure18
To enable door movement in the event of a power failure, an optional emergency battery can be connected. The system automatically switches to battery operation. During battery operation, the operator light remains switched off.
Danger of injury due to unexpected door travel
Unexpected door travel may occur when the emergency battery is still connected despite the mains plug being pulled out.
4.2.8 Hand transmitter
1 LED, bi-colour 2 Hand transmitter buttons 3 Battery
After inserting the battery, the hand transmitter is ready for operation.
See Figure19
WARNING
Disconnect the mains plug and the plug of the emergency battery whenever performing work on the door system.
*
* Accessory; not included in the standard
equipment!
TR10A148-F RE / 04.2017
27
ENGLISH

5 Setting DIL switches

5.1 Close limit switch reporting

See Figure20.1 and section5.8.1

5.2 Pre-warning time

See Figure20.2 and section5.8.2

5.3 External light

See Figure20.3 and section5.8.3

5.4 Automatic timer

See Figure20.4 and section5.8.4

5.5 Door type (soft stop)

See Figure20.5 and section5.8.5
5.6 Static current circuit / stop

5.7 Maintenance display

with self-testing
See Figure20.6 and section5.8.6
See Figure20.7 and section5.8.7
28
TR10A148-F RE / 04.2017
ENGLISH

5.8 DIL switch functions

Several of the operator's functions must be programmed using the DIL switches. Before initial start-up, the DIL switches are in factory settings, i.e. the switches are in the OFF position (see Figure9).
The following requirements must be met in order to change DIL switch settings.
• The operator is at rest.
• No radio control is being programmed.
A change to the DIL switches will have an immediate effect on the function.
Set the DIL switches as described below in accordance with the national regulations, the desired safety equipment and the on-site circumstances.
5.8.1 Close limit switch reporting
See Figure20.1
A
OFF
CLOSE limit switch reporting activated
B ON
Tab. 1: Function of the operator light and the option relay with activated CLOSE limit switch reporting
Operator light • Permanent light during the door run
• Illumination period after reaching
the Close end-of-travel position
Option relay Picks up when the Close end-of-travel
position is reached
5.8.2 Pre-warning phase
If the pre-warning phase is activated, it will always start before start of travel from any position.
If the automatic timer is set, the pre-warning phase will only start from the Open end-of-travel position.
See Figure20.2
A ON
Pre-warning phase activated
W
OFF
Tab. 2: Function of the operator light and the option relay with activated pre-warning phase
Operator light • Quick flashing during the
pre-warning phase
• Permanent light during the door run
Option relay Clocks during the pre-warning phase
and door travel (warning lamp function)
5.8.3 External light
See Figure20.3
A
OFF
B
OFF
External light activated
Tab. 3: Function of the operator light and the option relay with external illumination
Operator light • Permanent light during the door run
• Illumination period after reaching
the Close end-of-travel position
Option relay Same function as operator light
5.8.4 Automatic timer
With an automatic timer, the door is only opened with a travel command. The door closes automatically after the hold-open phase of approx. 30 seconds and the pre-warning phase have elapsed. After an impulse or after the photocell has been passed, the hold-open phase will be restarted automatically.
NOTE:
The automatic timer may only be activated within the scope of DINEN12453 if at least one additional safety device (photocell) is connected besides the standard power limit.
See Figure20.4
A ON
B ON
Automatic timer activated
Tab. 4: Function of the operator, the operator light and the option relay with activated automatic timer
Operator After hold-open phase and pre-warning
phase, automatic timer from the OPEN end-of-travel position
Operator light • Permanent light during the
hold-open phase and the door run
• Flashes during the pre-warning phase
Option relay • Permanent contact during the
hold-open phase (only from the Open end-of-travel position)
• Clocks during the pre-warning phase and door travel
5.8.5 Door type (soft stop)
See Figure20.5
C ON Up-and-over door, long soft stop
C
OFF
Sectional door, short soft stop
In a side sliding sectional door, the soft stop in the Close direction can be set using a combination of DIL switches C+D (depending on the track application of the side sliding sectional door).
If a long soft stop is set in the Close direction, the operator must start with a long soft start in the Open direction.
If a short soft stop is set in the Close direction, the operator will start normally in the Open direction.
C ON
D ON
Side sliding sectional door,
• Long soft stop in the Close direction
• Short soft stop in the Open direction
• Long soft start in the Open direction
TR10A148-F RE / 04.2017
29
ENGLISH
C
OFF
D ON
Side sliding sectional door,
• Short soft stop in the Close and Open direction
• Short soft start in the Open direction
With the side sliding sectional door setting, the power limit in the Open direction works as follows:
– The operator stops, briefly reverses in the Close
direction and takes the stress off the obstacle.
5.8.6 Static current circuit / stop with self-testing
A wicket door contact with self-testing is automatically detected and taught in during the learning run. After a successful learning run, the red LED in the transparent button flashes 7 ×.
A new learning run is required if the wicket door contact with self-testing is removed.
See Figure20.6
E ON Activated, for wicket door contact with
self-testing. The self-testing is checked before each door run (operation only possible with a wicket door contact that can be tested).
E
OFF
Safety equipment without self-testing
5.8.7 Door maintenance display
See Figure20.7
F ON Activated, exceeding the maintenance cycle
is signalled by the operator light flashing 3 × at the end of every door run.
F
OFF
Not activated, no signal after the maintenance cycle is exceeded.
The maintenance interval is reached when the operator has been in operation for more than 1year since the last teaching-in or the operator has reached or exceeded more than 2000door closing actions.
NOTE:
The maintenance data is reset by teaching in the operator again (see section6.1).

6 Initial start-up

Before initial start-up, read and follow the safety instructions in section2.6.
When teaching in (Figure21), the operator is adjusted to the door. The travel length, required force for opening and closing, and any connected safety devices are automatically taught in and saved in a power failure-proof manner. The data is only valid for this door.
Operator light:
The operator light is off if the operator has not been taught in. The operator light flashes during the learning runs or a
reference run. After the learning runs are finished, the operator light is continuously illuminated and goes out after approx. 2minutes.
WARNING
Danger of injuries due to faulty safety equipment
In the event of a malfunction, there is a danger of injuries due to faulty safety equipment.
After the learning runs, the person commissioning the system must check the function(s) of the safety equipment.
The system is ready for operation only after this.

6.1 Teaching in the operator

NOTES:
• The slide carriage must be engaged and there may not be any obstacles in the function range of the safety devices!
• Safety devices must be fitted and connected beforehand.
• If a connected wicket door contact with self-testing has
been successfully taught in, the red LED in the transparent button will flash 7 × after the learning run.
• If further safety devices are connected at a later point, a new learning run is required.
• All existing door data must be deleted if the operator is to be taught in again (see section11).
• When teaching in, the connected safety devices are not active.
30
TR10A148-F RE / 04.2017
To start the learning runs:
1. Plug in the mains plug.
The operator light will flash 2 ×.
2. Press the transparent button in the operator cover (or the circuit board button T if the operator cover has been removed).
– The door will open and briefly
stop in the Open end-of-travel position.
– To teach in the travel, the door
automatically closes, then
opens, closes again and opens again.
– The door closes and opens once
more and the required forces are
taught in. The operator light flashes during the learning runs.
– The door will stop in the Open
end-of-travel position. The
operator light remains
illuminated and goes out after
approx. 2minutes. – If a self-testing wicket door
contact has been successfully
taught in, the red LED in the
transparent button will flash 7 ×.
The operator has been taught in and is ready for operation.
To abort a learning run:
Press the transparent button or an external control element with impulse function. The door stops. The operator light is continuously illuminated.
Press the transparent button to start the entire teach-in process again.
NOTE:
If the operator stops with the operator light flashing or before reaching the end stop, the pre-set forces are too low and must be readjusted.
ENGLISH

6.2 Adjusting the forces

Also note section6.3
Reaching the potentiometer to set the forces:
Remove the operator cover.
P1 Set the force in the Open direction P2 Set the force in the Close direction
Increasing the forces:
Turn clockwise.
Reducing the forces:
Turn anticlockwise.
TR10A148-F RE / 04.2017
31
ENGLISH

6.3 Forces

CAUTION
Danger of injury due to the force value being set too high (potentiometers P1 / P2)
When the force value is set too high, the power limit is less sensitive. This could lead to injury or damage.
Do not set a force value that is too high.
The forces required for the learning in run are automatically adjusted during each door cycle. For safety reasons, it is necessary that the forces should not be readjusted indefinitely when the travel behaviour of the door becomes worse (e.g.the spring tension weakens). Otherwise risks to safety may arise with manual operation of the door (e.g. the door may fall down).
For this purpose, the maximum forces provided for opening and closing have a limited presetting in delivery condition (centre position of the potentiometers).
Proceed as follows if the Open end stop is not reached:
1. Turn P1 clockwise by one eighth of a rotation (seeFigure22).
2. Press the transparent button.
The door moves in the Close direction.
3. Press the transparent button again before the door reaches the Close end-of-travel position. The door stops.
4. Press the transparent button again. The door will move to the Open end-of-travel position.
If the Open end stop is not reached again, repeat steps1to4.
Proceed as follows if the Close end stop is not reached:
1. Turn P2 clockwise by one eighth of a rotation (seeFigure22).
2. Delete the door data (see section11).
3. Teach in the operator again (see section6.1).
If the Close end stop is not reached again, repeat steps1to3.
NOTE:
The forces actually needed are stored during the learning run. The maximum forces set on the potentiometer have little effect on the sensitivity of the power limit. The forces set at the factory can be used for operating standard doors.
7 Hand transmitter HSE4BiSecur
WARNING
Danger of injury during door travel
Persons may be injured by door travel if the hand transmitter is actuated.
Make sure that the hand transmitters are kept away from children and can only be used by people who have been instructed on how the remote­control door functions!
If the door has only one safety device, only operate the hand transmitter if you are within sight of the door!
Only drive or pass through remote control door systems if the door is in the Open end-of-travel position!
Never stay standing under the open door.
Please note that unwanted door travel may occur if a hand transmitter button is accidentally pressed (e.g. if stored in a pocket / handbag).
CAUTION
Danger of injuries due to unintended door travel
Unintended door travel may occur while teaching in the radio code.
Make sure no persons or objects are in the door's area of travel when teaching in the radio system.
CAUTION
Danger of burns from the hand transmitter
If exposed to direct sunlight or great heat, the hand transmitter may heat up so much that burns could occur during use.
Protect the hand transmitter from direct sunlight and great heat (e.g. by placing it in a stowage compartment in the dashboard).
ATTENTION
Malfunction due to environmental influences
Non-compliance with these instructions can impair function! Protect the hand transmitter from the following conditions:
• Direct sunlight (permissible ambient temperature:0 °Cto + 60 °C)
• Moisture
• Dust
NOTES:
• If there is no separate garage entrance, perform all programming changes and extensions of radio systems from inside the garage.
• After programming or extending the radio system, perform a function test.
• Only use original components when putting the radio system into service or extending it.
• Local conditions may affect the range of the radio system.
32
TR10A148-F RE / 04.2017
ENGLISH
• When used at the same time, GSM900 mobile phones can affect the range.

7.1 Description of the hand transmitter

See Figure19

7.2 Inserting / changing the battery

ATTENTION
Destruction of the hand transmitter by leaking batteries
Batteries can leak and destroy the hand transmitter.
Remove the battery from the hand transmitter if it is out of use for a long period of time.

7.3 Hand transmitter operation

A radio code is assigned to each hand transmitter button. Press the button of the hand transmitter whose radio code you want to transmit.
– The radio code is transmitted and the LED is
illuminated blue for 2 seconds.
NOTE:
If the battery is almost empty, the LED flashes red twice a. before transmitting the radio code.
The battery should be replaced soon.
b. and the radio code is not transmitted.
The battery must be replaced immediately.

7.4 Inheriting / transmitting a radio code

1. Press the button of the hand transmitter whose radio
code you want to inherit / transmit and keep it pressed. – The radio code is transmitted and the LED is
illuminated blue for 2 seconds then goes out.
– After 5 seconds, the LED alternates flashing in red
and blue; the radio code is transmitted.
2. If the radio code is transmitted and recognised, release the hand transmitter button.
– The LED goes out.
NOTE:
You have 15 seconds to inherit / transmit the code. The process must be repeated if the radio code is not successfully inherited / transmitted within this time.

7.5 Hand transmitter reset

Each hand transmitter button is assigned to a new radio code by means of the following steps.
1. Open the battery lid and remove the battery for 10seconds.
2. Press a circuit board button and keep it pressed.
3. Insert the battery.
– The LED slowly flashes in blue for 4 seconds. – The LED flashes rapidly in blue for 2 seconds. – The LED is illuminated blue for a long time.
4. Release the circuit board button. All radio codes are newly assigned.
5. Close the hand transmitter housing.
NOTE:
If the circuit board button is released prematurely, no new radio codes are assigned.

7.6 LED display

Blue (BU)
Condition Function
Illuminated for 2seconds A radio code is being transmitted Flashes slowly Hand transmitter is in the learn
mode
Flashes quickly after slow flashing
Flashes slowly for 4seconds
A valid radio code was discovered during the learning
Device reset is being performed
or completed Flashes quickly for 2seconds Illuminated long
Red (RD)
Condition Function
Flashes twice The battery is almost empty
Blue (BU) and Red (RD)
Condition Function
Flashing alternately Hand transmitter is in the
inherit / transmit mode

7.7 Cleaning the hand transmitter

ATTENTION
Damaging the hand transmitter by faulty cleaning
Cleaning the hand transmitter with unsuitable cleaning agents can damage the hand transmitter housing as well as the hand transmitter buttons.
Clean the hand transmitter with a clean, soft, damp cloth.
NOTE:
White hand transmitter buttons can change their colour when used regularly over an extended period of time, if they come in contact with cosmetic products (e.g. hand cream).

7.8 Disposal

Electrical and electronic devices, as well as batteries, may not be disposed of in household rubbish. They must be returned to the appropriate recycling facilities.
TR10A148-F RE / 04.2017
33
ENGLISH

7.9 Technical data

Type Hand transmitter HSE4BiSecur Frequency 868MHz Power supply 1 × 3V battery, type:CR2032 Perm. ambient temperature 0 °C to + 60 °C Protection category IP 20

8 Radio receiver

8.1 Integrated radio module

A maximum of 100 different hand transmitter buttons can be taught in and distributed to the Impulse (Open-Stop- Close-Stop) and partial opening functions. If more buttons are taught in, the one taught in first will be deleted.
The following requirements must be met in order to teach in hand transmitter buttons:
• The operator is at rest.
• The pre-warning or hold-open
phase is not active.
8.1.1 Teaching in the Impulse function
1. Briefly press the P button on the
operator cover. (Pressing it twice will immediately end the process). The red LED in the transparent button on the operator cover now flashes 1 ×.
2. Press the hand transmitter button
whose radio code you want to transmit and keep it pressed. (Please see section7.4 for more information on the hand transmitter). If a valid radio code is detected, the red LED in the transparent button on the operator cover will flash quickly.
3. Release the hand transmitter
button.
The hand transmitter button has been taught in and is now ready for operation.
The red LED in the transparent button flashes slowly and other hand transmitter buttons may be taught in.
4. Repeat steps 2 + 3 to teach in
further hand transmitter buttons.
If the same hand transmitter button is taught in on two different channels, it will be deleted on the first taught-in channel.
23

7.10 EU declaration of conformity for the hand transmitter

The manufacturer of this operator herewith declares that the provided hand transmitter complies with EU Directive Radio Equipment 2014/53/EU.
The complete declaration of conformity can be requested from the manufacturer.
34
TR10A148-F RE / 04.2017
ENGLISH
If no further hand transmitter buttons are to be taught in or to end the process:
Press the P button twice or wait for the timeout. The operator light is continuously illuminated.
Timeout
If no valid radio code is recognised within 20 seconds, the operator automatically switches to operation mode.
8.1.2 Teaching in the Partial opening function
A door position pre-set at the factory or any other door position can be programmed.
Approx. 260mm slide travel before the Close end-of-travel position.
Any At least 120 mm slide travel before each
end-of-travel position
To teach in the pre-set position:
1. Move the door into the Open or Close end-of-travel
position.
2. Briefly press the P button on the operator cover twice. (Pressing it three times will immediately end the process). The red LED in the transparent button on the operator cover now flashes twice.
3. Switch the hand transmitter whose code is to be inherited to Inheriting / Transmitting mode. If a valid radio code is detected, the red LED in the transparent button on the operator cover will flash quickly.
4. Release the hand transmitter button. The hand transmitter button has been taught in for the partial opening function.
The red LED in the transparent button flashes slowly and other hand transmitter buttons may be taught in.
5. Repeat steps 3 + 4 to teach in further hand transmitter buttons.
To teach in any position:
1. Move the door into the desired position (but at least
120mm before the end-of-travel position).
2. Briefly press the P button on the operator cover twice. (Pressing it three times will immediately end the process). The red LED in the transparent button on the operator cover now flashes twice.
3. Press the hand transmitter button you want to teach in until the red LED in the transparent button flashes quickly.
4. Release the hand transmitter button. The hand transmitter button has been taught in for the partial opening function. The red LED flashes and other hand transmitter buttons may be taught in.
5. Repeat steps 3 + 4 to teach in further hand transmitter buttons.
If the same hand transmitter button is taught in on two different channels, it will be deleted on the first taught-in channel.
If no further hand transmitter buttons are to be taught in or to end the process:
Press the P button once or wait for the timeout. The operator light is continuously illuminated.
Timeout
If no valid radio code is recognised within 20 seconds, the operator automatically switches to operation mode.

8.2 External receiver

*
If the range is limited, the functions impulse or partial opening can be controlled with an external radio receiver.
If an external radio receiver is retrofitted, the data in the integrated radio receiver must be deleted (see section12).
NOTE:
The antenna wire of external receivers should not come into contact with metal objects (nails, bracing, etc.). The best alignment to achieve an optimum range must be established by trial and error.
When used at the same time, GSM 900 mobile phones can affect the range.
8.2.1 Teaching in hand transmitter buttons
Teach in the hand transmitter button for the functions Impulse (channel1) and Partial opening (channel2) using the operating instructions for the external receiver.

8.3 EU Declaration of Conformity for Receivers

The manufacturer of this operator herewith declares that the integrated receiver complies with EU Directive Radio Equipment 2014/53/EU.
The complete declaration of conformity can be requested from the manufacturer.

9 Operation

WARNING
Danger of injury during door travel
If people or objects are in the area around the door while the door is in motion, this can lead to injuries or damage.
Children are not allowed to play near the door system.
Make sure that no persons or objects are in the door's area of travel.
If the door system has only one safety feature, only operate the garage door operator if you are within sight of the door's area of travel.
Monitor the door travel until the door has reached the end-of-travel position.
Only drive or pass through remote control door systems if the door is in the Open end-of-travel position!
Never stay standing under the open door.
CAUTION
Danger of crushing in the boom
Do not reach into the boom with your fingers during door travel, as this can cause crushing.
Do not reach into the boom during door travel
TR10A148-F RE / 04.2017
* Accessory; not included in the standard equipment!
35
ENGLISH
CAUTION
Danger of injury from the cord knob
If you hang on the cord knob, you may fall and injure yourself. The operator could break away and injure persons or damage objects that are located underneath, or the operator itself could be destroyed.
Do not hang on the cord knob with your body weight.
CAUTION
Danger of injury resulting from uncontrolled door movement in the Close direction if one of the counterbalance springs breaks and the slide carriage is released.
If a retrofit set is not installed, uncontrolled door movement in the Close direction may occur if the slide carriage is released while a counterbalance spring is broken, the door is improperly balanced or the door is not completely closed.
The responsible fitter must install a retrofit set on the slide carriage if the following applies:
– The standard DINEN13241-1 applies – The garage door operator is retrofitted to a
Hörmann sectional door without spring safety device (BR30) by a technical expert.
This set includes a screw that secures the slide carriage against uncontrolled unlocking as well as a new cord knob sign with images showing how the set and the slide carriage should be handled for the two operation modes of the operator boom.
NOTE:
The use of an emergency release or an emergency release lock is not possible in conjunction with the retrofit set.
CAUTION
Danger of injuries due to the hot lamp
Touching the lamp during or immediately following operation can lead to burns.
Do not touch the lamp if it is switched on or was recently switched on.
ATTENTION
Damage due to the cord of the mechanical release
If the cord of the mechanical release becomes caught on a roof carrier system or other parts of the vehicle or door, this can lead to damage.
Make sure that the cable cannot become caught.
Heat generation due to the illumination
As a result of heat being generated by the operator light, there is a risk of damage if the spacing is inadequate.
The smallest distance to easily inflammable materials or heat-sensitive surfaces must be at least 0.1m (seeFigure7).

9.1 Instructing users

All persons using the door system must be shown how to operate the garage door operator properly and safely.
Demonstrate and test the mechanical release as well as the safety reversal.

9.2 Function check

To check the safety reversal:
1. Stop the door with both hands
while it is closing. The door system must stop and initiate the safety reversal.
2. Stop the door with both hands while it is opening. The door system must switch off.
3. Position a test object with a height of approx. 50mm in the centre of the opening and close the door. The door system must stop and initiate the safety reversal as soon as it reaches the obstacle.
In the event of a failure of the safety reversal, a specialist must be commissioned immediately for the inspection and repair work.
9.2.1 Cord knob mechanical release
The cord knob for mechanical release may not be installed at a height greater than 1.8m from the garage floor. The cord may need to be extended on-site, depending on the height of the garage door.
When extending the cord, please make sure that the cord cannot become caught on a roof carrier system or any other vehicle protrusions.
WARNING
Danger of injury by fast-closing door
If the cord knob is actuated while the door is open, there is a danger that the door will close rapidly if the springs are weak, broken or defective, or if the counterbalance is inadequate.
Only pull the cord knob when the door is closed.
Pull the cord knob when the door is closed. The door is now released and should be easy to open and close by hand.
9.2.2 Mechanical release by emergency release lock
(Only for garages without a second entrance)
When the door is closed, actuate the emergency release lock. The door is now released and should be easy to open and close by hand.

9.3 Normal operation

NOTE:
If the radio code for the taught-in hand transmitter was copied from another hand transmitter, the hand transmitter button must be pressed a second time during initial start-up.
36
TR10A148-F RE / 04.2017
ENGLISH
Impulse function (channel1)
In normal operation, the garage door operator works with the impulse sequence control.
The door behaves as follows if an external button (at terminal 20 / 21 or at the intercom clamp), a taught-in hand transmitter button for the impulse function (channel1) or the transparent button is pushed.
1st impulse: The door runs towards an end-of-travel
position. 2nd impulse: The door stops. 3rd impulse: The door runs in the opposite direction. 4th impulse: The door stops. 5th impulse: The door runs in the direction of the
end-of-travel position selected in the
1stimpulse. etc.
Partial opening function (channel2)
The door behaves as follows if an external button (at terminal 20 / 23) or a taught-in hand transmitter button for the partial opening function (channel2) is pushed.
From the Close end-of-travel position: 1st impulse: The door moves in the partial opening direction.
2nd impulse: The door stops. 3rd impulse: The door moves in the partial opening direction. etc.
From the Open end-of-travel position: 1st impulse: The door moves in the partial opening direction.
2nd impulse: The door stops. 3rd impulse: The door moves in the partial opening direction. etc.
From the partial opening position:
Impulse at
The door moves in the Open direction. terminal 20 / 21 Impulse at
The door moves in the Close direction. terminal 20 / 23
The operator light will light up during a door run and go out after approx.2minutes.
9.4 Behaviour during a power failure (without an
emergency battery)
To be able to open or close the garage door by hand during a power failure, it must be disengaged from the slide carriage while the door is closed.
See section9.2.1 / 9.2.2
9.5 Behaviour after the power returns (without
emergency battery)
After the power returns, the slide carriage for automatic operation must be re-engaged.
See Figure6
Due to safety reasons, if the power fails during operation, the first impulse command will always open the door.

10 Inspection and maintenance

The garage door operator is maintenance-free. In the interest of your own safety, we recommend having the
door system inspected and maintained by a qualified person in accordance with the manufacturer's specifications.
WARNING
Danger of injury due to unexpected door travel
Unexpected door travel may occur during inspection and maintenance work if the door system is inadvertently actuated by other persons.
Disconnect the mains plug and the plug of the emergency battery whenever performing work on the door system.
Safeguard the door system against being switched on again without authorisation.
Inspection and repairs may only be carried out by a qualified person. Contact your supplier for this purpose.
A visual inspection may be carried out by the operator.
Check all safety and protective functions monthly.
Check safety devices without self-testing every six months.
Any malfunctions and / or defects must be remedied
immediately.

10.1 Tension of the toothed belt

The toothed belt of the operator boom is tensioned optimally ex-factory.
During the start-up and slow-down phase, with larger doors it is possible that the belt will briefly hang out of the boom profile. However, this does not constitute a technical malfunction and does not negatively affect the function and service life of the operator.

10.2 Checking safety reversal / reversing

To check safety reversal / reversing:
1. Stop the door with both hands
while it is closing. The door system must stop and initiate the safety reversal.
2. Stop the door with both hands while it is opening. The door system must switch off.
3. Position a test object with a height of approx. 50mm in the centre of the opening and close the door. The door system must stop and initiate the safety reversal as soon as it reaches the obstacle.
In the event of a failure of the safety reversal, a specialist must be commissioned immediately for the inspection and repair work.
TR10A148-F RE / 04.2017
37
ENGLISH

10.3 Replacement bulb

Only use a bulb: – 24V / 1,0W B(a) 15s LED – 24V / 10W B(a) 15s
Exchange the light bulb only if the operator is voltage-free.

11 Deleting door data

The existing door data must be deleted before the operator can be taught in again.
See Figure25
To reset to the factory settings:
1. Disconnect the mains plug and, if
applicable, the plug of the emergency battery.
2. Press and hold the transparent button on the operator cover.
3. Reconnect the mains plug.
4. Release the transparent button
once the operator light flashes once. The door data has been deleted.
5. Teach in the operator again (seesection6.1).
NOTE:
The taught-in impulse radio codes are not changed.
12 Deleting all radio
codes
There is no option to delete the radio codes for individual hand transmitter buttons.
See Figure26
1. Press and holdthe Pbutton on the operator cover. The red LED in the transparent button of the operator cover flashes slowly, signalling the readiness for deletion. The red LED will start to flash quickly. The data of all the hand transmitters' learned radio codes is deleted.
2. Release the P button.
NOTE:
If the P button is released prematurely, the process will be aborted and the radio codes are not deleted.
38
TR10A148-F RE / 04.2017
ENGLISH

13 Optional accessories

Optional accessories are not included in the scope of delivery. Loading of the operator by all electrical accessories:
max.100mA. The following accessories can be connected to the operator:
• One-way photocell, self-testing dynamic photocell
• Emitter-reflector photocell
• External radio receiver
• External impulse buttons (e.g. key switches)
• Emergency battery for emergency power supply
• Wicket door contact (self-testing and non-self-testing)
• Warning light (in combination with the relay PR1)

14 Dismantling and disposal

NOTE:
When dismantling the door, observe the applicable regulations governing work safety.
Have a specialist dismantle the garage door operator in the reverse order of these instructions and dispose of it properly.

15 Warranty conditions

Warranty period
In addition to the statutory warranty provided by the dealer in the sales contract, we grant the following warranty for parts from the date of purchase:
• 5 years on operator technology, motor and motor control
• 2 years on radio equipment, accessories and special
systems
Claims made under the warranty do not extend the warranty period. For replacement parts and repairs the warranty period is six months or at least the remainder of the warranty period.
Prerequisites
The warranty claim only applies in the country where the equipment was purchased. The product must have been purchased through our authorised distribution channels.
A claim under this warranty exists only for damage to the object of the contract itself.
Services
For the duration of the warranty we shall eliminate any product defects that are proven to be attributable to a material or manufacturing fault. We pledge to replace free of charge and at our discretion the defective goods with non-defective goods, to carry out repairs, or to grant a price reduction. Replaced parts become our property.
Reimbursement of expenditure for dismantling and fitting, testing of parts as well as demands for lost profits and compensation for damages are excluded from the warranty.
Damage caused by the following is also excluded:
• Improper fitting and connection
• Improper initial start-up and operation
• External factors such as fire, water, abnormal
environmental conditions
• Mechanical damage caused by accidents, falls, impacts
• Negligent or intentional destruction
• Normal wear or deficient maintenance
• Repairs conducted by unqualified persons
• Use of non-original parts
• Removal or defacing of the data label
16 EC / EU Declaration of
Conformity / Declaration of Incorporation
fined in EC Machinery Directive 2006/42/EC according
(as de to annexII, part1A for the complete machine or part1B for incorporation of partly complete machinery)
Only a combination with specifically approved door types is permissible in order to fit this garage door operator by the end user. These door types can be found in the complete EC/EU Declaration of Conformity in the provided log book.
However, if this garage door operator is not combined with an approved door type, the fitter will then be considered a manufacturer of a complete machine.
In this case, fitting may only be done by a fitting company, as only they have knowledge of the relevant safety regulations, valid directives and standards, as well as the required testing and measuring devices.
The appropriate declaration of incorporation can also be found in the provided log book.
TR10A148-F RE / 04.2017
39
ENGLISH

17 Technical data

Mains voltage 230 / 240 V, 50 / 60Hz, Stand-by ≤7W Protection category Only for dry rooms
Temperature range – 20°C to + 60°C Replacement bulb • 24V / 1,0W B(a) 15s LED
Motor Direct current motor with hall
Transformer With thermal protection Connection No-screw connection technology
Remote control Operation with internal or external
Automatic cut-out Is automatically taught in for both
End-of-travel position cut-out / power limit
Guide rail Extremely flat (30mm)
Door travel speed Approx. 13cm per second
Rated load See data label Pull and push force See data label Short-term peak load See data label Special functions Operator light, 2-minute light
Mechanical release Actuated from inside with pull cord
Universal fittings For up-and-over doors and
Airborne sound emission of the garage door operator ≤ 70dB (A)
Use Exclusively for private garages
Door cycles See product information
• 24V / 10W B(a) 15s
sensor
for external equipment with 24VDC low safety voltage, such as internal and external buttons with impulse operation
radio receiver
directions separately. Self-learning, wear-free, as it has no mechanical switches.
Automatic safety cut-out, readjusting at every door run.
With integrated anti-lift kit With maintenance-free, patented toothed belt with automatic belt tensioner
(depending on door size and weight)
Photocell can be connected Option relay for warning lamp, additional external illumination can be connected Wicket door contact with testing
in the event of a power failure
sectional doors
Not intended for industrial / commercial use

18 Display of messages and errors

18.1 Operator light messages

If the mains plug is plugged in without the transparent button having been pushed (the circuit board buttonT when the operator cover has been removed), the operator light will flash two, three or four times.
2 × flashing
No door data is present or the door data has been deleted (delivery condition). The operator can be taught in immediately.
1 × flashing
Saved door data is present, but the last door position is not known. For this reason, the next run will be a OPEN reference run. Door travel in normal operation will follow.
4 × flashing
Saved door data is present and the last door position is sufficiently known, i.e. normal door runs that take the impulse sequence control (OPEN-STOP-CLOSE-STOP-OPEN, etc.) into account can proceed immediately (normal behaviour after a successful teach-in and power failure). For safety reasons, the door will always open upon the first impulse command after a power failure during a door run.
40
TR10A148-F RE / 04.2017
ENGLISH

18.2 Display of errors / warnings / information

The red diagnostic LED is visible through the transparent button even when the housing is closed. This LED helps to easily identify causes when operation does not go according to plan. This LED is continuously illuminated in normal operation.
NOTE:
If normal operation of the garage door operator with the radio module / receiver or the transparent button is otherwise possible, ashort circuit in the external button's connecting lead or in the button itself can be recognised through the behaviour describedhere.
Display Error / warning Possible cause Remedy
Safety equipment (photocells) No photocell is connected Connecting a photocell
The light beam is interrupted Adjust the photocell The photocell is defective Exchange the photocell
Power limit in the Close direction
The door is too sluggish or does not move smoothly
Correct the door travel
Obstacle in door area Remove the obstacle and teach in the operator
again, if necessary
Static current circuit open The wicket door is open Close the wicket door
The magnet has been fitted the wrong way
Fit the magnet correctly (see the instructions for the wicket door contact)
The testing result is not OK Exchange the wicket door contact
Power limit in the Open direction
The door is too sluggish or does not move smoothly
Correct the door travel
Obstacle in door area Remove the obstacle and teach in the operator
again, if necessary
System error Internal error Give a new travel command (impulse)1 and
move the door into the Open end-of-travel position
Restore the factory setting (see section11), teach in the operator again or exchange, if necessary
Travel time limit The belt is torn Exchange the belt
The operator is defective Exchange the operator
Wicket door contact with self-testing taught in
No error Only a confirmation that it has been successfully taughtin
The operator has not been taught in
The operator has not been taught in yet
Teach in the operator (see section6)
No reference point Power failure
The operator requires an Open reference run
1) with an external button, the radio module or the transparent button (circuit board button T when the operator cover is removed).
Give a new travel command (impulse)1 and move the door into the Open end-of-travel position
TR10A148-F RE / 04.2017
41
ENGLISH

19 Overview of DIL switch functions

DIL A DIL B Function Option relay function
OFF OFF External light activated Relay the same as operator light (external light function)
ON OFF Pre-warning phase activated Relay clocks during the pre-warning phase and the door
OFF ON CLOSE limit switch reporting activated The relay picks up in the Close end-of-travel position
ON ON Automatic timer activated, photocell
DIL C DIL D Door type (soft stop)
OFF OFF Sectional door Short soft stop
ON OFF Up-and-over door Long soft stop OFF ON Side sliding
ON ON Side sliding
DIL E Static current circuit / stop with self-testing
OFF Safety equipment without self-testing
ON Wicket door contact with self-testing activated. The self-testing is checked before each door run
(operationonly possible with a wicket door contact that can be tested)
DIL F Door maintenance display
OFF Not activated, no signal after the maintenance cycle is exceeded
ON Activated, exceeding the maintenance cycle is signalled by the operator light flashing at the end of every
door run.
must be installed
sectional doors
sectional doors
• Short soft stop in the Close and Open direction
• Short soft start in the Open direction
• Long soft stop in the Close direction
• Short soft in the Open direction
• Long soft start in the Open direction
run (warning lamp function).
(Close reporting function) Relay clocks during the pre-warning phase and the door
run, permanent contact during the hold-open phase (only from the Open end-of-travel position)
42
TR10A148-F RE / 04.2017
TR10A148-F RE / 04.2017
43
TR10A148-F RE / 04.2017
GaraMatic 9
Garador Ltd Bunford Lane Yeovil, Somerset www.garador.co.uk