Thank you for your purchase of this product. Before operating the product,
please read this instruction manual carefully to ensure proper use of the
product. Please store this instruction manual in a safe place for future
reference.
CONTENTS
PRODUCT FEATURES ............................................................................ EG-2
SAFETY PRECAUTIONS ......................................................................... EG-2
PARTS DESCRIPTION ............................................................................ EG-3
INSTALLATION AND ADJUSTMENT ...................................................... EG-4
SPECIFICATIONS .................................................................................. EG-11
PRODUCT FEATURES
High resolution surveillance camera with a built-in 1/3-type CCD.
Integrated varifocal lens allows for versatile application and easy installation.
D D/N (Digital Day/Night) function provides a bright picture even in low light
conditions.
Surface or embedded installation.
Manual pan/tilt/rotation mechanism.
Accept either 12V DC or 24V AC power input. (Automatic switching)
SAFETY PRECAUTIONS
The installation should be made by a qualified service person and should conform to all
local codes.
This symbol indicates that there is a possibility of death or damage to operator
or others.
To prevent fire or electric shock, do not expose this product to rain or moisture.
This symbol indicates that there is a possibility of injury or damage to
equipment.
(1) Use only 24V AC power supply marked class 2 or +12V DC regulated power
supply marked class 2.
(2) To prevent fire or electrical shock, UL listed class 2 wiring should be used for the
12V DC or 24V AC input terminal.
(3) Be sure to connect each lead to the appropriate terminal. Wrong connection may
cause malfunction and / or damage to the video camera.
(4) Do not attempt to aim the camera at the sun or other extremely bright objects that
cause smear to appear irrespective of whether the camera is operating or not. This
can damage the CCD (Charge Coupled Device).
(5) Do not place the camera in the following locations.
Locations subject to extremely high or low temperatures.
(Operating temperature range: -10°C to +50°C {14°F to 122°F})
(Storage temperature range: -20°C to +60°C {-4°F to 140°F})
Locations subject to high levels of humidity and dust.
(Operating humidity range: max 85% {No condensation})
(Storage humidity range: max 95% {No condensation})
Locations where there are large amounts of water vapor and steam.
(6) Ensure the location selected is sufficiently strong enough to support the weight of
the camera and is free from vibration.
(7) When this camera is installed near equipment that emits a strong electromagnetic
field, some irregularity such as noise on the monitor screen may happen.
(8) Be sure to use screws suitable for the type of material to which the camera is
being mounted.
(9) Do not allow the camera to be subjected to strong impacts or shocks. The camera
could be damaged by improper handling or storage.
(10) Never attempt to disassemble or modify the camera.
(11) If an abnormality should occur, immediately turn off the power and consult your
dealer.
This device complies with Part 15 of the FCC Rules. Operation is subject to following
two conditions:
(1) This device may not cause harmful interference.
(2)
This device must accept any interference received, including interference that may
cause undesired operation.
EG-2
PARTS DESCRIPTION
Exterior
Surface mount cover
Coaxial video cable
Body cover
Camera body
Inner cover
Dome cover
Accessories
Service monitor cable Adapter ring
Removing and attaching the cover
Dome cover
To remove : Pull the cover away.
To attach : Insert the cover and push it gently until you hear a click.
Body cover
To remove :
To attach : Align the corrugations on the camera body and body cover,
Insert a flat-bladed screwdriver into the groove between the
camera body and the body cover, then twist the screwdriver.
then push until you hear a click.
M4 x 20 2 pcs.
Self-tapping screws
Camera body interior
Positioning of the lens body
angle/focus lever varies depending
on the lens. The levers are marked
with the following guides. Please
refer to these marks for operation
when using the product.
N
: Focus adjustment lever
W T
: View angle adjustment lever
Mode setting switch
Power input terminal
EG-3
WSC switch (This switch is for use in servicing
the product. Do not use it.)
Lens
Line phase
adjustment volume
Video output
connector for
service monitor
cable
D D/N switch
Coaxial
video cable
DC iris
adjustment
volume
INSTALLATION AND ADJUSTMENT
Attaching the unit
You can use the following three methods to attach the unit. Please use the
method that best fits the conditions of the area in which you want to install
the unit.
Attaching to the surface of the ceiling or wall
Use this method to attach the
unit to the surface of the ceiling
or wall.
(page EG-5)
Embedding in the ceiling or wall
Use this method to attach the
unit by embedding it in the ceiling
or wall.
(page EG-6)
● Be sure to use the adapter ring to
attach the camera.
Attaching to a 4S junction box
Use this method to attach the
unit when a 4S junction box is
available.
(page EG-6)
● Be sure to use the adapter ring to
attach the camera.
Installation and adjustment process
Use the following steps to attach and adjust the unit.
Drilling holes in the ceiling/wall
Attaching the camera body
Connecting the cables (Page EG-7)
Setting the mode setting switch (Page EG-7)
Attaching the service monitor (Page EG-8)
Adjusting the camera direction (Page EG-8)
Adjusting the view angle, focus and iris (Page EG-9)
Adjusting the line phase
(When using an AC24V 60Hz power source
in the line lock mode)
Adjusting the DC iris level (Page EG-9)
Setting the D D/N switch
Installation and adjustment complete (Page EG-10)
EG-4
(Page EG-10)
(Depending on the
method of attachment,
page EG-5, EG-6)
(Page EG-9)