Ganz ZA-NVE40K Hardware Manual

ZA-NVE40K Hardware Manual
2010/2-1 D 2
Table of Contents
Safety and Regulatory Information.....................................................................................................3
2.1. Specifications............................................................................................................................6
2.2. Power Consumption..................................................................................................................6
2.2. Unit view ..................................................................................................................................7
2.3. Mechanical characteristics........................................................................................................9
3.1. Specifications..........................................................................................................................10
3.2. Unit view ................................................................................................................................10
3.3. Mechanical characteristics......................................................................................................11
3.4. Ejecting and inserting blades..................................................................................................11
Ejecting a blade...................................................................................................................... 11
Inserting a blade.....................................................................................................................12
3.5. Factory Default Settings.........................................................................................................12
3.6. Rebooting................................................................................................................................13
4.1. Specifications..........................................................................................................................14
4.2. Unit view ................................................................................................................................14
4.3. Electrical characteristics.........................................................................................................15
4.4. Environmental characteristics.................................................................................................16
4.5. Mechanical characteristics......................................................................................................16
4.6. Pin Description .......................................................................................................................17
4.7. Ejecting and inserting PSU.....................................................................................................18
Ejecting a PSU .......................................................................................................................18
Inserting a PSU......................................................................................................................18
5.1. Description..............................................................................................................................19
5.2. Unit view ................................................................................................................................19
5.3. Electrical characteristics.........................................................................................................20
5.4. Environmental characteristics.................................................................................................20
5.5. Mechanical characteristics......................................................................................................20
ZA-NVE40K Hardware Manual
2010/2-1 D 3
Safety and Regulatory Information
WARNING: TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. THE APPARATUS MUST NOT BE EXPOSED TO DRIPPING OR SPLASHING AND NO OBJECTS FILLED WITH LIQUIDS, SUCH AS VASES, SHOULD BE PLACED ON THE APPARATUS.
CAUTION: TO PREVENT ELECTRICAL SHOCK, IF THE UNIT IS PROVIDED WITH A POLARIZED PLUG, DO NOT CONNECT THE PLUG INTO AN EXTENSION CORD, RECEPTACLE, OR OTHER OUTLET UNLESS THE PLUG CAN BE FULLY INSERTED WITH NO PART OF THE BLADES EXPOSED.
CAUTION: TO ENSURE REGULATORY AND SAFETY COMPLIANCE, USE ONLY THE PROVIDED POWER AND INTERFACE CABLES.
CAUTION: DO NOT OPEN THE UNIT. DO NOT PERFORM ANY SERVICING OTHER THAN THAT CONTAINED IN THE INSTALLATION AND TROUBLESHOOTING INSTRUCTIONS. REFER ALL SERVICING TO QUALIFIED SERVICE PERSONNEL.
CAUTION: FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE AND RATING OF FUSE.
CAUTION: RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS.
RACK MOUNT INSTRUCTIONS
A) Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer.
B) Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised.
C) Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading.
D) Circuit Overloading - Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
E) Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit (e.g. use of power strips)."
FCC COMPLIANCE
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
ZA-NVE40K Hardware Manual
2010/2-1 D 4
CE COMPLIANCE
This is A class product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
ZA-NVE40K Hardware Manual
2010/2-1 D 5
1. Introduction
ZA-NVE40K compress video/audio data and transmit the compressed video/audio data through the network in real time. GANZ encoder provides a high quality video image with a limited bandwidth and storage capacity. These products are ideally suited for a wide range of surveillance and remote monitoring applications. Main features are highlighted below.
ZA-NVE40K
Main features
19” / 4U Aluminum Sub-Rack
Support up to 10 units of 4 ch GANZ Encoder Blades (Total 40 channels @ D1)
Hot-swappable GANZ Encoder Blade, fan unit and power unit
Identification of each Sub-Rack and each blade unit ( for easy and quick maintenance)
Temperature Sensor included
Detect power supplier unit operation ( Self-diagnosing)
Detect fan unit operation (Self-diagnosing)
Applied device: ZN-RS4000 series (It is the blade version of ZN-S4000 series)
ZN-RS4000 series
Main features
High Quality Compression in real time streaming
ZN-RS4000 provides high quality MPEG-4 and MJPEG encoding at D1 in real time.
Network
RTP/RTSP and unicast/multicast are supported.
Streaming
support dual streaming mode such as different codec/resolution/bit rate and so on.
support de-interlacing by hardware.
Video/Audio
Support quad view in external monitor.
Support two ways audio (ZN-S100AE supports only audio input)
Transmits to client - G.711 by software Receives from client - one digital audio
Additional Features
RS-485 serial port for Pan/Tilt/Zoom. (Except ZN-S100AE )
RS-232C serial port for some devices like a POS terminal. (Except ZN-S100AE )
Motion detection by hardware.
On Screen Display (OSD) by hardware.
SDK
Four types (RTSP, UDA5, ActiveX, HTTP-API) are provided for application development.
ZA-NVE40K Hardware Manual
2010/2-1 D 6
2. Subrack
2.1. Specifications
ZA-NVE40K and ZN-RS4000AE series specification is shown as following
Construction Aluminum, 19” / 4U Sub-Rack
Applied Device ZN-RS4000AE series
Available Slots 10 ea (Hot Swappable Blades)
Input 85 ~ 264 VAC, 47~63Hz, 2A Power
Type Dual Power Supply Video Input 4 ch (BNC Type) Audio Input 4 ch (2.5 mm Pitch Terminal Block, Pluggable)
Audio Output 1 ch (2.5 mm Pitch Terminal Block, Pluggable)
Digital Input/Output 4 / 2 ch (2.5 mm Pitch Terminal Block, Pluggable)
RS-232C/RS-485 1 / 1 ea
Connector
(Each slot)
Network 10/100 Base-T
Fan Unit 1,800 rpm x 3ea
Temperature 0 oC ~ 60 oC (32 oF ~ 140 oF)
Humidity Upto 85% RH
Dimension 482.6(W) x 177(H) x 322(D) mm
Weight 7,420 g (Power Cable included) +
1,300 g (ZN-RS4000AE series x 10ea)
Table 1. Specification for ZA-NVE40K
2.2. Power Consumption
Minimum – Including 1 x ZN-RS4040AE (V1.42) and no fan unit
Input Voltage 12 V
Current 812 mA
Consumption 9.74 W
Maximum – Including 10 x ZN-RS4040AE (V1.42) and 3 fan units
Input Voltage 12 V
Current 10382 mA
Consumption 124.58 W
Rack case & fan unit (Without ZN-RS4040AE)
Rack case 32 mA
Fan unit(1ea) 850 mA
ZA-NVE40K Hardware Manual
2010/2-1 D 7
2.3. Unit view
Figure 1. GANZ encoder subrack
Loading...