Ganz GWK1 Quick Start Guide

Page 1
QUICK START GUIDE
INDUSTRIAL OUTDOOR 802.11A/N WIRELESS ETHERNET
This manual serves the following GANZ Model Numbers:
GWK1
Thank you for purchasing the GWave wireless kit from GANZ. This quick start guide is designed to walk you through installation.
This guide applies to the following models:
GWK1: Industrial Point to Point Kit, FCC Version (Includes GWK1_AP and GWK1_CL)
An easy to read LED array displays unit operational status along with received signal strength ensuring optimal installation and operation. See Figure 2 on Page 2 for LED Indicator explanations.
See Figures 3 through 5 beginning on Page 3 for mounting instructions.
INS_GWK1_QS_REV– 07/7/15 PAGE 1
Page 2
QUICK START USER GUIDE GWK1
FIGURE 1 – INDUSTRIAL WIRELESS ETHERNET LINK
PORT 1 PORT 2
BOTTOM
FIGURE 2 – STATUS INDICATING LEDS
LED VISUAL CUE INDICATION
RSSI1POWER
RSSI2LAN
RSSI3
RSSI4
POWER
LAN
RSSI1 SOLID RED Weak Connection
RSSI2 SOLID ORANGE Moderate Connection
RSSI3 SOLID GREEN Solid Connection
RSSI4 SOLID GREEN
PORT 1PORT 2
BACKFRONT
IMPORTANT: Only plug PoE power to Port 1.
Connecting a PoE power source to the PSE Port (#2) will cause a major device malfunction and void the warranty.
SOLID GREEN Power is supplied to the unit
OFF No power is supplied to the unit, or the unit is in reset.
SOLID GREEN LAN Connected
OFF No Connectivity
Excellent Connection
(Advisable to check Status Page to confirm RSSI is > -55)
SIGNAL STRENGTH:
WEAK SIGNAL EXCELLENT SIGNAL
INS_GWK1_QS_REV– 07/7/15 PAGE 2
Page 3
QUICK START USER GUIDE GWK1
FIGURE 3 – INSTALLATION INSTRUCTIONS
Step 1.
Unpack the mounting hardware from the box. Determine if this will be a pole or wall mount application. The included Mounting kit is designed to support poles up to 2 in (5.8 cm) in diameter. If surface or wall-mounting, additional hardware will be required.
Step 2.
A. Route the RJ45 connectorized Ethernet cable through the
weather tight gland connection as shown at left.
Note: The slit rubber washer allows a pre-terminated
Ethernet cable to be used.
Once the cable has been routed through the weather
connection as shown above, push the split rubber gasket into place and loosely screw the cap that goes over the rubber washer.
A
B
B. Snap the RJ-45 connector in place as shown
A
Ethernet Network
B C
P1
A
B
C
D
Step 3.
Slide the weather proof assembly over the cable so it can be screwed into the enclosure gland. Make sure the rubber sealing ring is in place as shown in step 3A.
Tighten the weather proof assembly into the enclosure and also tighten the cap that squeezes the rubber washer over the Ethernet cable as shown.
Step 4.
A. Connect one end of an RJ-45 Ethernet cable to the OUT
port of the Power Injection Module (PIM) and the other end to LAN of the access point.
Network
Edge Device
P2
D
D
Maximum length of the RJ-45 CAT5 cable is 100 meters.*
B. Connect the RJ-45 Ethernet cable attached to the PIM to a
network device, such as to a switch or to the PC you will use to configure the access point.
C. Connect the power adaptor to the main electrical supply
and the power plug into the socket of the PIM.
PoE power input: Passive PoE (range 36 to 48 VDC). The GW1 can also be powered by a suitable IEEE 802.3af/at PSE device such as a PoE switch or injector.
D. A Drip Loop is recommended as additional precaution
against moisture entering the Access Point housing.
* Up to 200mW radio. For higher power radio upgrade to higher rating
power adapter.
INS_GWK1_QS_REV– 07/7/15 PAGE 3
Page 4
QUICK START USER GUIDE GWK1
FIGURE 4 – POLE MOUNT INSTRUCTIONS
Included Hardware
Vertical Mount in -45º Position Vertical Mount in +45º Position
INS_GWK1_QS_REV– 07/7/15 PAGE 4
Page 5
QUICK START USER GUIDE GWK1
INSTALLATION REQUIREMENTS
Shielded outdoor CAT 5 or better should be used for all out of plant Ethernet connection and should be properly grounded through the PoE AC ground. Industrial grade shielded Ethernet cable is recommended to help prevent ESD damage commonly experienced with outdoor installations.
CONFIGURING GWAVE
1. Connect an Ethernet cable from the port labelled as IN on the power Injection Module to either a laptop or a PC LAN port.
2. Connect the second Ethernet cable from the OUT port on the Power Injection Module to the GWave LAN port.
3. Apply 48 VDC to the Power Injection Module with the provided power supply. You should notice the green LED illuminate in the Power Injection Module and the power LED on the GWave unit.
4. Set the IP address of the laptop being used to configure GWave to static and the subnet to 192.168.10.x/24 subnet.
5. Point the Browser to 192.168.10.100 for the Access Point or 192.168.10.101 for the Client. These are the default addresses.
6. A login prompt will pop up. Enter: ID: admin Password: admin
7. Select the NETWORK » Interfaces tab, click on Edit in the LAN settings section to change the IP address of the device. and set the desired network settings.
• Hit Save & Apply NOTE: This will be the network address for the GWave web server. It is not necessary to set to the same subnet as the
operating network but it is recommended.
8. Select the NETWORK -> WIFI tab and set:
• Wireless mode – Set to AP or Client
• Output RF power – if RSSI is greater than -40, it is recommended to reduce RF TX power at the connected remote node.
• Set SSID – if changing from the default setting
• Channel Spectrum Width – May want to reduce to 20M from the default 20/40M if the 5GHz spectrum is crowded or connections across the link are unstable.
• Wireless Security – if changing from default settings
• Hit Save & Apply
INS_GWK1_QS_REV– 07/7/15 PAGE 5
Page 6
QUICK START USER GUIDE GWK1
CONFIGURING MAC LOCK FOR POINT TO POINT LINKS
MAC-Filter replaces MAC-Lock on the first generation GWave hardware.
MAC-Filter is only available on devices operating as an AP. By default, it is disabled.
You can locate MAC-Filter tab by going to Networking -> WIFI -> Enable.
To enable and lock to a client radio, Click on the drop down menu and select “Allow Listed Only”.
A new dialog box will appear. Click on the new bland dialog box and click on customer, enter the MAC address of the client
radio you would like to MAC lock to and hit “Save & Apply”.
UNDERSTANDING RSSI AND SIGNAL STRENGTH
The Received Signal Strength Indicator (RSSI) is intended to be used as an indicator of the quality of connection that exists between an Access Point and Client radio.
The RSSI value is determined by the Signal Strength.
Signal Strength is based on a number of factors, including the output power of the radios, antenna gain and the attenuation of the signal as it travels from the transmitter to the receiver.
Signal strength is expressed in dBm. dBm is a power ratio in decibels (dB) referenced to 1mW. Since most received signal levels are under 1mW, negative values are typically displayed. The more negative the number, the weaker the received signal.
The following can be used as a guideline to determine signal quality
RSSI Signal Quality
Less than -75 to -95 dBm No Signal or intermittent operation
-75 dBm and greater Moderate Connection
-65 dBm and greater Solid Connection
-55 to Zero dBm Excellent Connection
RESET TO FACTORY DEFAULT
Press and hold the reset button for 4-30 Seconds to reset the radio back to factory defaults.
Note: A simple press of the reset button will restart the radio. Holding the reset button for
longer than 30 seconds will not do anything. Whenever the reset button is pressed, the power LED will go dark.
RESET
DEFAULT CONFIGURATIONS
IP Address of Web Server 192.168.10.100 (GWK1_AP)
192.168.10.101 (GWK1_CL)
LAN Mode for Web Server Static Addressing
Web Server User ID admin
Web Server Password admin
SSID GWave-1
WPA Pre-shared Key 12345678
Channel-Frequency (AP) Auto
Channel Spectrum Width 20/40M
Long Range Parameters Enabled and defaulted to
1000m
NOTE: A Reset to defaults (performed on the ADMIN page or via the RESET button) will erase all user configurations.
INS_GWK1_QS_REV– 07/7/15 PAGE 6
Page 7
QUICK START USER GUIDE GWK1
TYPICAL POINT-TO-POINT CONFIGURATION
Cat5 Cable
10/100Mbps
PC NVR
Gigabit Managed
Switch with
30W PoE+
PoE
GW1
(Set to Access Point)
POINT-TO-POINT TOPOLOGY UTILIZING DUAL PORTS
GW1
(Client)
P1
P2
10/100 Mbps
GANZ Managed Switch with 30 W PoE Connected to Network
GW1
(Access Point)
Ethernet
PoE
Ethernet
PoE
GW1
(Set to Client)
PIM or other PSE device
Ethernet
PIM
or other
PSE device
Ethernet
IP
Camera
Power
IP Camera
IP Camera
Power
INS_GWK1_QS_REV– 07/7/15 PAGE 7
Page 8
QUICK START USER GUIDE GWK1
Scanto view mobile catalog
CBC reserves the right to modify product specifications without prior notice and assumes no responsibility for errors in this publication.
All products mentioned in this publication are acknowledged to be the property of their respective trademark owners.
©2015 CBC AMERICAS Corp. All rights reserved.
ganzsecurity.com
CBC AMERICAS Corp.
Corporate Headquarters, NY
West Coast Mexico City
Tel: +1-800-422-6707 Tel: +1-877-407-9555 Tel : +52 55 5280 4660
AGENCY COMPLIANCE
FCC
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
• This device may not cause harmful interference, and
• This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operations of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Industry Canada
This Class A digital apparatus complies with Canadian ICES-003. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (EIRP) is not more than that permitted for successful communication. This device complies with Industry Canada license-exempt RSS standard(s).
Operation is subject to the following two conditions:
• This device may not cause interference, and
• This device must accept any interference, including interference that may cause undesired operation of the device.
Cet appareil numérique de la classe A est confrome à la norme NMB-003 Canada. Pour réduire le risque d’interférence aux autres utilisateurs, le type d’antenne et son gain doivent être choisies de façon que la puissance isotrope rayonnée équivalente (PIRE) ne dépasse pas ce qui est nécessaire
pour une communication réussie. Cet appareil est conforme à la norme RSS Industrie Canada exempts de licence norme(s). Son fonctionnement est soumis aux deux conditions suivantes:
17 Compliance
• Cet appareil ne peut pas provoquer d’interférences et
• Cet appareil doit accepter toute interférence, y compris les interférences qui peuvent causer un mauvais fonctionnement du dispositif.
RF Exposure Warning
The antennas used for this transmitter must be installed to provide a separation distance of at least 2.52m from all persons and must not be located or operating in conjunction with any other antenna or transmitter.
Les antennes utilisées pour ce transmetteur doivent être installé en considérant une distance de séparation de toute personnes d’au moins 2.52m et ne doivent pas être localisé ou utilisé en conflit avec tout autre antenne ou transmetteur.
CE Marking
CE marking on this product represents the product is in compliance with all directives that are applicable to it.
This equipment may be operated in the following countries:
Austria, Belgium, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Latvia, Lithuania, Malta, Netherlands, Norway, Portugal, Romania, Czech Republic, Croatia, Slovakia, Slovenia, Sweden, UK
Installer Compliance Responsibility
Devices must be professionally installed and it is the professional installer’s responsibility to make sure the device is operated within local country regulatory requirements.
RoHS/WEEE Compliance Statement
European Directive 2002/96/EC requires that the equipment bearing this symbol on the product and/or its packaging must not be disposed of with unsorted municipal waste. The symbol indicates that this product should be disposed of separately from regular household waste streams. It is your responsibility to dispose of this and other electric and electronic equipment via designated collection facilities appointed by the government or local authorities. Correct disposal and recycling will help prevent potential negative consequences to the environment and human health. For more detailed information about the disposal of your old equipment, please contact your local authorities, waste disposal service, or the shop where you purchased the product.
INS_GWK1_QS_REV– 07/7/15 PAGE 8
Page 9
CBC AMERICAS Corp.
Corporate Headquarters, NY Tel: +1-800-422-6707 Tel: +1-877-407-9555 Tel : +52 55 5280 4660
West Coast Mexico City
ganzsecurity.com
Scanto view mobile catalog
CBC reserves the right to modify product specifications without prior notice and assumes no responsibility for errors in this publication.
All products mentioned in this publication are acknowledged to be the property of their respective trademark owners.
©2015 CBC AMERICAS Corp. All rights reserved.
Loading...