A. 3 in 1 Machine Table
B. Racquet Clamp for Swing Weight Test
C. Balance Bar
D. Calibration Weight & Bar
E. LCD Cable
F. LCD Screen
G. 5 mm L-shaped Hex Wrench
H. 3 mm L-shaped Hex Wrench
I. Micro Screw Driver for Calibration
J. Power Supply Cord
K. Weight Scale Platform
- 2 -
Issue 1-031009
ASSEMBLY INSTRUCTIONS –
A.
A. Attach the balance beam to the machine table using the 5 mm L-shaped hex wrench.
B. Slide the weight onto the end of the calibration bar and place it in the hooks on the right side of the machine
C. D.E.
C. Check the bull’s eye level located in the racquet clamp and adjust the footpads until the bubble is centered in the sight glass.
D. Turn the footpads clockwise to lower the level of the base and counter clockwise to raise the level of the base.
E. Make sure the voltage switch is set to the correct setting and connect the power cord to the power outlet. After switching the machine on,
wait for 3 “beeps” and then the machine will be ready to use.
A. Fully extend the balance beam by sliding it out of its holder.
B. Place the racquet on the balance beam and rotate the beam to slide the
C. Observe the end of the racquet as it slides over the table and read the balance
Issue 1-031009
racquet to the right side of the table. (Note: The grip may tend to stick to the
table and cause the racquet to slip on the balance beam as the beam is turned.
If this occurs, it is best to place the racquet on the balance beam close to its
balance point from the start.)
point off the scale where the butt end of the racquet lifts off the table.
It is important to periodically check the accuracy of the Swing Weight me asurement of the GAMMA R TC from time to time and make calibration
adjustments when needed. The RTC includes a Calibration Bar and Calibration Weight for this purpose.
A. B.C.
The Swing Weight can be checked at: (A) - 100 kg/cm2 with the Calibration Bar alone, (B) - 200 kg/cm2 with the Calibration Weight locked on
the bar at the “200” mark, and (C) - 300 kg/cm2 with the Calibration Weight locked on the bar at the “300” mark. When placing the Calibration
Bar into the Racquet Clamp, the flat edge on the bar should be facing up and the end of the Calibration Bar should rest against the backside of
the Racquet Clamp. Measurement accuracy is +/- 2 kg/cm2.
If the swing weight displayed on the LCD screen does not match the value of the Calibration Bar
within +/- 2 kg/cm2, adjust the display to match the value stated on the Calibration Bar by turning the
adjustment screw labeled “Swing” located on the back side of the PCB using the micro screw driver
provided with the RTC as pictured in Step (D).
It is important to periodically check the accuracy of the W eight Scale measurement of the GAMMA RTC from time to time and make calibration
adjustments when needed. The RTC includes a Calibration Bar and Calibration Weight for this purpose.
A. B.
The Weight Scale can be checked at: (A) - 185 grams using the Calibration Weight alone and (B) - 270 grams using the Calibration Bar alone.
Measurement accuracy is +/- 1 gram.
If the weight displayed on the LCD screen does not match the value of the Calibration Weight
or Calibration Bar within 1 gram, adjust the display to match the value of the Calibration Weight
or Calibration Bar by turning the adjustment screw labeled “Weight” located on the back side of
the PCB using the micro screw driver provided with the RTC as pictured in Step (C).
When performing the Swing Weight Test, it is very important that the end of the racquet or Calibration Bar be positioned against the backside of
the Racquet Clamp as illustrated in Figure 1 below.
It is equally important that the machine table be level. If the table is tilted up at the front (Figure 2) the Swing Weight measurement will be higher
than the standard. If it is tilted down (Figure 3) the Swing Weight measurement will be less than the standard.
GAMMA SPORTS warrants to the original purchaser that the GAMMA 3-in-1 RTC ("EQUIPMENT") purchased is free from defects
in materials and workmanship for a period of five (5) years from the date of original purchase excluding electrical parts and the
racquet clamp, and for a period of one (1) year from the date of original purchase for all electrical parts and the racquet clamp.
Should any defects develop under normal use within the specified time periods, GAMMA will at its option, repair or replace the
defective EQUIPMENT provided it is returned to GAMMA prepaid at the purchaser's expense. This warranty does not apply to any
damage or defect caused by negligence, abuse, misuse, unauthorized alteration, shipping, handling or part wear and tear as a
result of normal use.
Any routine maintenance, adjustment, and cleaning required to ensure proper operation are the responsibility of the purchaser and
are not covered under the terms of this warranty.
GAMMA’s obligation under this warranty is limited to repair or replacement of defective EQUIPMENT, and no one is authorized to
promise any other liability. GAMMA shall in no event be liable for any incidental or consequential damages.
To return defective EQUIPMENT, a return authorization (RA#) must be obtained from a GAMMA customer service representative
by calling 1-800-333-0337 or 412-323-0335. The RA# must be marked on the outside of the shipping carton being returned. All
returns must be shipped prepaid by the customer to GAMMA. Please retain the original shipping carton and packing materials for
any future shipments. GAMMA will not be responsible for machines that are not sent in the original undamaged packaging.