Game Ready 550550-03, 550550-03-RN, 550550-53 User Manual

GRPro™ 2.1 CONTROL UNIT
SUPERSEDED
MODEL NUMBERS
550550-03, 550550-03-RN, 550550-53
Brought to you by CoolSystems, Inc.
1800 Sutter Street, Suite 500
Concord, CA 94520
1.888.GameReady (1.888.426.3732)
+1.510.868.2100
www.gameready.com
Game Ready Control Unit User’s Manual PN 703758 Rev D
©2011 CoolSystems, Inc. All rights reserved.
This User’s Manual is also available online in
English, French, German, Italian, Japanese, and Spanish
at www.gameready.com under Products.
53
DESCRIPTION OF THE GRPRO 2.1 SYSTEM
SUPERSEDED
The following items are included in your GRPro 2.1 System:
TABLE OF CONTENTS
p
a Wr .
g
Av
.
p
m
Te
3
h
1 /
g
i
5 5
H d e
0
M
1
/ 0 5
w o L
ff
7
O
/
e
5
r
4
u s s
e r
P
5
/ 0 4
C º
/ F º
h
t a
B
e
c
.
I
p
m
Te
n u R
e
p
m
e
Ti
e l
S
e
m
Ti
GRPro 2.1 Control Unit
A Wrap (comprised of an inner ATX Series Heat Exchanger and an outer Sleeve) must be attached to the System to begin treatment. Each Wrap is sold separately and is not included in the System.
Power Indicator
Pressure Backlight
olume
V
Power Cord
AC Adapter
Pressure Indicator
Welcome Packet (containing the User’s Manual and other information about your System)
Connector Hose
™ Series Heat Exchanger
Wrap
(sold separately)
Sleeve
Actual Temperature
Detailed Instructions for Use ________________________________ 2
Modes of Operation _____________________________________ 2
Buttons ________________________________________________ 2
Adjusting Temperature __________________________________ 3
Display _________________________________________________ 3
Operating the System ___________________________________ 5
Storage ____________________________________________________ 8
Cleaning ___________________________________________________ 9
Maintenance _______________________________________________ 10
Accessories ________________________________________________ 11
Indications for Use __________________________________________ 11
Contraindications ___________________________________________ 12
General Warnings and Cautions ____________________________ 12
Specifications ______________________________________________ 13
UL Classification ___________________________________________ 14
Electromagnetic Compatibility _______________________________ 15
Troubleshooting ___________________________________________ 19
Warranty __________________________________________________ 22
Med
High
Coldest
Run
Wrap Temp.
Time
C/F
Actual Temperature
55/13
50/10
45/7
40/5
ºF/ºC
Target Temperature
(Celsius/Fahrenheit)
Temperature Knob
Target Temperature
Power
Program
Play/ Pause
Pressure
Sleep Time
Subtract Time
Low
Off
Add Time
(Manual Mode)
DETAILED INSTRUCTIONS FOR USE
SUPERSEDED
Do not use this device without your physician’s specific recommendations for the frequency and duration of your treatments.
The most common recommendation is to use cold therapy at least 4 times a day, for approximately 30 minutes each time, with at least a 30-minute break between treatments. While the temperature is adjustable, it is reported that the greatest benefit from cold therapy is in the 40- 60°F (4.5-15.5°C) are for “None” to “Low” pressure settings during the first 24-48 hours after surgery or injury, increasing to “Medium” or “High” only if it is comfortable after the first 48 hours. We recommend that “High” pressure is never applied if you are confined to bed.
Be sure to read further safety warnings on pages 12-13 of this User’s Manual.
Manual Mode: The System automatically starts in this mode, and allows the user to adjust treatment time and pressure settings. Program Mode: This mode allows the user to choose one of six treatment programs that provide therapy for a set time then sleep (no treatment) for a set time, continuously, at a specific pressure setting. Drain Mode: Allows a user to connect a Hose with a special Hose Adapter (purchased separately) to the unit, enter Drain Mode and have the unit empty the water out of the ice box through the Hose. Drain Mode can be accessed by pressing the program key and toggling through all six programs. To empty water in the System while in Drain Mode, press the program key until you reach Drain Mode, attach the Hose Adapter to the Connector Hose, place the Hose Adapter over a sink, and press the Play button. Drain Mode will run the Control Unit’s fluid pump for up to six minutes (long enough to fully empty the ice box). Drain Mode is indicated by the following icons:
Power: Use this button to turn the Control Unit on and off.
Program: Use this button to select one of the available Programs or to return to
Manual Mode. See page 8 in this manual for more information on Programs.
temperature range. Generally reported compression recommendations
MODES OF OPERATION
BUTTONS
ADJUSTING TEMPERATURE
To adjust the temperature being applied during treatment, simply turn the temperature knob towards 3 snowflakes for the maximum amount of cold, or towards 1 snowflake for the least amount of cold. Notice that as you adjust the knob, the “Target Temperature” on the display will change. The System will automatically adjust to match the temperature you have selected.
TIP: The maximum amount of cold is dictated by the amount of ice in the reservoir and the setting of the temperature adjustment knob. You may need to stir or replenish the ice to achieve coldest temperatures. Ice will melt faster in the acute phases of injury as the Game Ready System is removing greater amounts of heat from the treatment site.
DISPLAY
Status bar:
Other Icons:
Error
Sleep
Battery
Off (Mute)
On
Indicates selected mode.
Indicates unit is paused.
Indicates unit is running.
Indicates an error. See troubleshooting pages 15-17 for error codes.
Indicates sleep mode time.
Indicates remaining battery capacity.
EN- 2
Play/Pause: Use this button to start or pause a treatment.
Add Time: Use this button to add time in Manual Mode (does not work in Program
Mode). You can add up to 90 minutes. Treatment must be paused in order to add or subtract time.
Subtract Time: Use this button to reduce time in Manual Mode (does not work in Program Mode). You can subtract up to 90 minutes. Treatment must be paused in order to add or subtract time.
Pressure Selection: Use this button to select one of four pressure settings: No Pressure, Low Pressure (5-15 mmHg), Medium Pressure (5-50 mmHg), and High Pressure (5-75 mmHg). Pressure selection is not available in Program Mode. Treatment must be paused to change pressure settings.
Volume: Use this button to select the option of sound or no sound. Push to mute sound. Alarms will still sound even with Volume off.
C/F Button: Use this button to select either Celsius or Fahrenheit on the temperature display.
Backlight: Use this button to turn the backlight on or off.
Temperature:
Actual Temperature:
temperature of the water leaving the Control Unit.
Target Temperature:
temperature setting. The Control Unit will automatically match the Actual Temperature and Target Temperature as closely as possible.
Approximate
Indicates the target
EN-3
When the System
SUPERSEDED
is running in Program Mode:
When the System is running in Manual Mode:
When selecting a program:
Sleep time count-down bars.
Displays amount of time unit will sleep.
Displays the amount of run time remaining.
Run time count-down bars.
Displays the amount of sleep time remaining.
Displays the amount of run time remaining.
Displays pressure.
Pressure
Off
Sleep Time
Low
Med
High
Run
Target
Time
Temperature
Displays amount of time unit will run.
Actual Temperature
55/13
50/10
45/7
40/5
ºF/ºC
OPERATING THE SYSTEM
To operate your GRPro 2.1 System, you need:
Control Unit filled with ice and water as indicated by the fill line labels within the
reservoir. Optimal performance is achieved by first adding 1.5 liters of water, and then filling the reservoir to the top with ice.
Game Ready supplied power supply.
Connector Hose.
Wrap (includes a Heat Exchanger and Sleeve).
Notes:
The Wrap is comprised of an inner Heat Exchanger and an outer Sleeve. The combination
of Sleeve and Heat Exchanger is referred to throughout this manual as a “Wrap.” To ensure proper performance, be sure to use ATX Series Heat Exchangers.
The GRPro 2.1 Control Unit should be placed on a stable surface (such as the floor or a
table) during use.
Note that using the System in an environment with a high ambient temperature may
affect its ability to provide adequate cooling, or may limit the ice life.
If you will be using the System with a Game Ready optional battery pack (sold separately),
please consult the instructions for use that accompany that battery pack.
Warning:
Your GRPro 2.1 Control Unit should be plugged into a grounded electrical outlet prior to
operation.
Position the Control Unit to minimize the risk of tripping over the Control Unit, Connector
Hose, or power cord.
Precautions:
Failure to properly follow the instructions of this manual and those of your medical
provider may interfere with or prevent delivery of appropriate therapy.
To avoid risk of electrical shock unplug the Control Unit from the electrical outlet prior to
filling the Control Unit with ice and water.
1
Push the door release button to open the ice box door.
EN- 4
Low
Pressure:
Off
Off
Off
Off
Med
High
Low
Med
High
Low
Med
High
Low
Med
High
EN-5