− The Galvin Specialised CliniLever® product range is primarily used for hand washing applications in
hospitals, aged care facilities, schools and in-home care.
− CliniLever
− The dual levers for on/off, hot and cold temperature have a straight forward operation which simplifies
hand washing.
− Our highly sought after lever handle design can easily be operated with wrists or elbows.
− The main body is made of solid dezincification resistant (DR) brass rod, with a DR brass fixed outlet.
− Quick action SBA’s include brass jumper valve / ceramic cartridge components, with red and blue
indicator buttons on 80mm lever action handles.
®
products provide state of the art features to comply with the latest healthcare guidelines.
IMPORTANT: All CliniLever® healthcare taps are tested in accordance with AS/NZS 3718 and leave our
TECHNICAL DATA
Inlet G5/8 BSP- Male
Outlet
Working Pressure Range (kPa)
Working Temperature (°C)
Nominal Flow Rate (LPM) N/A
Finish Chrome
Galvin Specialised continually strive to improve their products. Specifications may change without notice.
Min 50
Max 500
Min 5
Max 85
N/A
PRE-INSTALLATION
− Wall body must be G5/8” FI and body should be between
0 and 13mm behind the finished wall surface.
TOOLS REQUIRED
Page 2
1. Fit spindle assembly
− Fasten securely using a spanner.
2. Fit wall flange
3. Fit handle
4. Fit water temperature indicator & testing
INSTALLATION
IMPORTANT: Galvin Specialised products must be installed in accordance wi th these installation instructions and
in accordance with AS/NZS 3500, the PCA and your local regulatory requirements. Water and/or electrical supply
conditions must also comply to the applicable national and/or state standards. Failing to comply with these
provisions shall void the product warranty and may affect the performance of the product.
−Remove handle and flange from spindle
assembly.
−Ensure jumper valve and fibre washer are fitted to
spindle assembly.
− Screw entire assembly into the wall body.
− Ensure o-ring is fitted to the bottom of the wall
flange, and then hand-tighten the wall flange
onto the threaded sleeve.
−Ensure the spindle is in the closed position and
firmly press the CliniLever
the spindle in the desired orientation.
−Check CliniLever
®
lever handles for operation. It
®
lever handle onto
should turn freely for a full ¼ turn.
−Secure the handle in position using the supplied
washer and stainless steel cap screw.
−Once CliniLever® lever handle is secure; fit the
appropriate water temperature indicator.
−Once temperature indicator is fitted, check the
operation of the unit and inspect for any leaks.
Page 3
TROUBLESHOOTING
PROBLEM CAUSE RECTIFICATION
Taps are dripping water Jumper valves are worn or damaged Replace jumper valve
Tap seat is damaged Refurbish tap seat using a reseating
tool.
Water is leaking from spindle O-ring on jumper valve spindle is
damaged or worn
Water is not flowing from tap Water is turned off Turn on water
Aerator or flow regulator is blocked by
debris
Spindle is difficult to turn
(jumper valve)
Handle is loose Screw has come loose Tighten handle screw
Flange does not screw down onto
wall surface
Build up of scale on spindle, spindle
worn or o-ring has been damaged
Wall bodi es are set too far out Re-position tap bodies
Replace o-ring
Remove aerator and/or flow
regulator from tap and remove
debris. Install an inline strainer.
Remove jumper valve, clean and
regrease. Replace o-ring. Complete
SBA may need to be replaced.
SERVICE AND MAINTENANCE
JUMPER VALVE TAPWARE
1. Turn off the water supply and turn on the tap handle to drain water from the bodies.
2. Remove the temperature indicator from the handle.
3. Remove the handle from the tap.
4. Unscrew the top assembly from the body.
5. Check the o-ring on the spindle and the jumper valve for wear and damage. Replace if required.
6. Clean the spindle and body of debris.
7.Place a new o-ring (if required) onto the spindle and re-grease with potable water approved grease.
8. Re-assemble top assembly. Follow the product installation guidelines for the relevant product
re-assembly method.
Page 4
WARRANTY
The warranty set forth herein is given expressly and is the only warranty given by the Galvin Engineering Pty Ltd.
With respect to the product, Galvin Engineering Pty Ltd makes no other warranties, express or implied. Galvin
Engineering Pty. Ltd. hereby specifically disclaims all other warranties, express or implied, including but not limited
to the implied warranties of merchantability and fitness for a particular purpose.
Galvin Engineering Pty Ltd products are covered under our manufacturer’s warranty available for download from
www.galvinengineering.com.au Galvin Engineering Pty Ltd expressly warrants that the product is free from
operational defects in workmanship and materials for the warranty period as shown on the schedule in the
manufacturer’s warranty. During the warranty period, Galvin Engineering will replace or repair any defective
products manufactured by Galvin Engineering without charge, so long as the terms of the Manufacturer’s warranty
are complied with.
The remedy described in the first paragraph of this warranty shall constitute the sole and exclusive remedy for
breach of warranty, and Galvin Engineering Pty Ltd shall not be responsible for any incidental, special or
consequential damages, including without limitation, lost profits or the cost of repairing or replacing other property
which is damaged if this product does not work properly, other costs resulting from labour charges, delays,
vandalism, negligence, fouling caused by foreign material, damage from adverse water conditions, chemical,
electrical or any other circumstances over which Galvin Engineering has no control. This warranty shall be
invalidated by any abuse, misuse, misapplication, improper installation or improper maintenance or alteration of the
product.