Gallagher Group C30040X Users Manual

InstallaƟ on Note
Gallagher T10 Mifare Reader
ATTENTION: This equipment contains components that can be damaged
by electrosta c discharge. Ensure both you and the equipment are earthed before beginning any servicing.
The Gallagher T10 Mifare Reader
The Gallagher T10 Mifare Reader is a smart card proximity reader. It can be installed as either an entry reader or exit reader.
The reader can read: Mifare DESFire EV1, Mifare Plus and Mifare Classic cards.
The reader sends informa on to the Gallagher Controller and acts upon informa on sent from the Gallagher Controller. The reader itself does not make any access decisions.
The Gallagher T10 Mifare Reader uses the Cardax IV communica ons protocol to communicate with the Gallagher Controller.
Note: A French transla on of this document can be downloaded from the Gallagher Support Site: hƩ p://support.gallagher.co
Before you begin
Shipment Contents
Check the shipment contains the following items:
1 x Gallagher T10 Reader facia assembly
1 x Gallagher T10 Reader base
1 x M3 Torx Post (T10) Security screw
2 x 25 mm No.6 self tapping, pan head, Phillips drive fi xing screws
2 x 40 mm No.6 self tapping, pan head, Phillips drive fi xing screws
Part Number: 3E2453 | Edi on 8 November 2012
Page 1
Gallagher T10 Mifare Reader
Power Supply
The Gallagher T10 Mifare Reader is designed to operate over a supply voltage range of 9 - 16 Vdc measured at the reader terminals. The opera ng current draw is dependent on the supply voltage at the reader. At 12 Vdc the current draw is 82 mA (standby). During card read, beeper and LED ac vity, the current will momentarily reach 115 mA (peak).
The power source should be linear or a good quality switched-mode power supply. The performance of the reader may be aff ected by a low quality, noisy power supply.
Cabling
The Gallagher T10 Mifare Reader requires a minimum cable size of 4 core 24 AWG (0.2 mm data (2 wires) and power (2 wires). When using a single cable to carry both power supply and data, both the power supply voltage drop and data requirements must be considered. Although the reader is specifi ed to operate at 9 Vdc, for good engineering design it is recommended that the voltage at the reader should be approximately 12 Vdc.
Installa on Note
2
) stranded security cable. This cable allows the transmission of
Examples of approved cables for connec ng a single Gallagher T10 Mifare Reader to a Controller and power supply, showing maximum cable lengths for each type of cable and the associated circuits are:
Combined
Manufacturer
reference Cable format*
CAT5E 4 twisted pair
Each 2 x 0.2 mm2 (24 AWG)
SEC472 4 x 0.2 mm
Not twisted pairs (24 AWG)
SEC4142 4 x 0.4 mm
Not twisted pairs (21 AWG)
BELDEN 8723 2 twisted pair
Each 2 x 0.4 mm
BELDEN 9842 2 twisted pair
Each 2 x 0.2 mm
2
2
2
(22 AWG)
2
(24 AWG)
power and data
in a single cable
Data only in a
single cable
100 m (330  ) 300 m (1000  )
100 m (330  ) 250 m (800  )
150 m (500  ) 150 m (500  )
100 m (330  ) 150 m (500  )
100 m (330  ) 200 m (650  )
* The matching of wire sizes to equivalent wire gauges are only approximate.
Grounding shielded cable may reduce the obtainable cable length by 25% to 30%.
Page 2
Edi on 8 | Part Number: 3E2453
November 2012
Installa on Note
Distance between Proximity Readers
The distance separa ng any two proximity readers must not be less than 200 mm (8 inches) in all direc ons.
When moun ng a proximity reader on an internal wall, check that any reader fi xed to the other side of the wall is not less than 200 mm (8 inches) away.
Gallagher T10 Mifare Reader
200 mm
200 mm
InstallaƟ on
The Gallagher T10 Mifare Reader is designed to be mounted on any solid fl at surface. However installa on on metal surfaces, par cularly those with a large surface area will reduce read range. The extent to which the range is reduced will depend upon the type of metal surface.
The recommended moun ng height for the reader is 1.1 m (3.6  ) from the fl oor level to the centre of the reader device. However this may vary in some countries and you should check local regula ons for varia ons to this height.
1. Using the drill template at the back of this installa on note as a guide, drill all
2. Run the building cabling out through the centre hole and through the reader
3. Secure the base to the moun ng surface using the two fi xing screws provided.
three holes. Drill the 13 mm (1/2 inch) diameter centre hole (this is the centre hole for which the building cable will exit the moun ng surface) and the two xing holes.
base.
It is important the base of the reader is fl ush with and  ght against the moun ng surface.
Note: Ensure the centre hole allows the cable to run freely out through the moun ng surface, so that the reader facia can clip into the base.
Part Number: 3E2453 | Edi on 8 November 2012
Page 3
Gallagher T10 Mifare Reader
4. Connect the reader tail extending from the facia assembly to the building cable. Connect the wires shown below.
Installa on Note
Base
No. 6 pan head screw
Building cable
No. 6 pan head screw
Note: Do not cut the “Reserved” wires, as they may be used for future func ons.
Posi ve Red Nega ve Black Reserved Orange Reserved Green Reserved Brown CDXIV TX White
Cardax IV Reader
CDXIV RX Blue
5. Fit the facia assembly into the base by clipping the small lip, into the top of the base and holding the top, press the bo om of the facia assembly down into the base.
6. Insert the M3 Torx Post Security screw (using a T10 Torx Post Security screwdriver) through the hole at the bo om of the base to secure the facia assembly.
Note: The Torx Post Security screw needs only to be lightly  ghtened. The recommended torque for the security screw is 0.7 Nm (0.5 lb/ ). It is important not to exceed the maximum torque of 1.5 Nm (1.1 lb/ ).
Page 4