Gallagher Group C30020X Users Manual

Installation Note | Gallagher T10 Mifare Reader
Installation Note
Gallagher T10 Mifare Reader
This equipment contains components that can be damaged by electrostatic discharge. Ensure both you and the equipment are earthed before beginning any servicing.
The Gallagher T10 Mifare Reader
The Gallagher T10 Mifare reader is a smart card proximity reader. It can be installed as either an entry reader or exit reader.
The reader can read Mifare DESFire EV1, Mifare Plus and Mifare Classic cards.
The reader sends information to the Cardax FT Controller and acts upon information sent from the Cardax FT Controller. The reader itself does not make any access decisions.
The Gallagher T10 Mifare reader uses the “Cardax IV Reader” communications protocol to communicate with the Cardax FT Controller.
Part Number: 3E2453 R1 | 1
Installation Note | Gallagher T10 Mifare Reader
Before you begin
Shipment Contents
Check the shipment contains the following items:
1 x Gallagher T10 Mifare reader facia assembly• 1 x Gallagher T10 Mifare reader base• 1 x Gallagher T10 Mifare reader installation note• 1 x M3 Torx Post Security screw• 2 x self tapping pan head pozi fixing screws•
Power Supply
The Gallagher T10 Mifare reader receives power from the device to which it is connected. The reader is designed to operate over a supply voltage range of 9 - 16Vdc measured at the reader terminals. The operating current will be approximately 40mA (at 16Vdc) and 70mA (at 9Vdc). The operating current will increase to approximately 120mA (at 12Vdc) momentarily during a card read, beeper and LED activity.
Cabling
The power source should be linear or a good quality switched-mode power supply. The performance of the reader may be affected by a low quality, noisy power supply.
The Gallagher T10 Mifare reader requires a minimum cable size of 4 core 24 AWG (0.2mm2) stranded security cable. This cable allows the transmission of data (2 wires) and power (2 wires). When using a single cable to carry both power supply and data, both the power supply voltage drop and data requirements must be considered. For good engineering design, it is recommended that the voltage at the reader should be approximately 12Vdc.
The critical specifications for the cable are:
Data: The capacitance between any two wires or between
a wire and any shielding should be less than 24nF
Power supply: The voltage at the reader must be at least 9Vdc
Examples of approved cables for connecting a single Gallagher T10 Mifare reader to a Controller and power supply, showing maximum cable lengths for each type of cable and the associated circuits are:
2 | Part Number: 3E2453 R1
Cable type Combined power and data
CAT5e 100m (320ft)
2
SEC472 (4 x 0.2mm
SEC4142 (4 x 0.4mm
) 100m (320ft)
2
) 100m (320ft) BELDEN 8723 (22 AWG) 152m (500ft) BELDEN 9842 (24 AWG) 152m (500ft)
Distance between Proximity Readers
The distance separating any two proximity readers must not be less than 200mm (8 inches) in all directions.
Installation Note | Gallagher T10 Mifare Reader
in a single cable
When mounting a proximity reader on an internal wall, check that any reader fixed to the other side of the wall is not less than 200mm (8 inches) away.
Installation
The Gallagher T10 Mifare reader is designed to be mounted on any solid flat surface. However installation on metal surfaces, particularly those with a large surface area will reduce read range. The extent to which the range is reduced will depend upon the type of metal used.
200mm
200mm
Wall thickness
less than 200mm
The recommended mounting height for the reader is 1.1m (3.6ft) from the floor level to the centre of the reader device. However this may vary in some countries and you should check local regulations for variations to this height.
Part Number: 3E2453 R1 | 3
Installation Note | Gallagher T10 Mifare Reader
Using the drill template at the back of this installation note as a 1. guide, drill all three holes. Drill the 13mm (1/2 inch) diameter centre hole (this is the centre hole for which the building cable will exit the mounting surface) and the two fixing holes.
Run the building cabling out through the centre hole and through the 2. reader base.
Secure the base to the mounting surface using the two fixing screws 3. provided. It is important the base of the reader is flush with and tight against the mounting surface.
Note: Ensure the centre hole allows the cable to run freely out through the mounting surface, so that the reader facia can clip into the base.
Base
6 Gauge screw
Building cable
6 Gauge screw
Connect the reader tail extending from the facia assembly to the 4. building cable. Connect the wires shown below.
Note: Do not cut the ‘Reserved’ wires, they may be required later.
Positive Red Negative Black Reserved Orange Reserved Green Reserved Brown CDXIV TX White
Cardax IV Reader
CDXIV RX Blue
Fit the facia assembly into the base by clipping the small lip, into the 5. top of the base and holding the top, press the bottom of the facia assembly down into the base.