ATTENTION: This equipment contains components that can be damaged by electrosta c discharge. Ensure both you and the equipment are earthed before beginning any servicing.
The Gallagher T11 Reader
The Mifare reader reads: Mifare DESFire EV1, Mifare Plus and Mifare Classic cards. The Mul Tech reader reads: Mifare DESFire EV1, Mifare Plus, Mifare Classic and 125 kHz cards.
The reader sends informa on to the Gallagher Controller and acts upon informa on sent from the Gallagher Controller. The reader itself does not make any access decisions.
The Gallagher T11 Reader uses the “Cardax IV Reader” communica ons protocol to communicate with the Gallagher Controller.
Note: A French transla on of this document can be downloaded from the Gallagher Support Site: hƩ p://support.gallagher.co
IMPORTANT: Gallagher T11 MulƟ Tech readers only:
Using dual technology 125/Mifare cards with Gallagher T11 Mul Tech readers may cause both card technologies to be read, resul ng in double card badges and unusual reader feedback. Gallagher strongly recommends against using dual technology 125/Mifare cards with Gallagher Mul Tech readers for sites running pre-Command Centre v7.00 so ware (due for release 2nd half, 2011). From Command Centre v7.00, a site may specify which technology a Mul Tech reader should read off a dual technology card.
InstallaƟ on Note
Gallagher T11 Reader
Page 2
Gallagher T11 Reader
Edi on 10 | Part Number: 3E2513
November 2012
Installa on Note
Before you begin
Shipment Contents
Check the shipment contains the following items:
1 x Gallagher T11 Reader facia assembly
1 x Gallagher T11 Reader base
1 x M3 Torx Post Security screw
2 x 6-32 UNC Phillips drive fi xing screws
4 x 25 mm No.6 self tapping, pan head, Phillips drive fi xing screws
4 x 40 mm No.6 self tapping, pan head, Phillips drive fi xing screws
Power Supply
The Gallagher T11 Reader is designed to operate over a supply voltage range of 9 - 16 Vdc measured at the reader terminals. The opera ng current draw is dependant on the supply voltage at the reader. For the Mifare reader at 12 Vdc the current draw is 90 mA (standby). During card read, beeper and LED ac vity, the current will momentarily reach 125 mA (peak). For the Mul Tech reader at 12 Vdc the current draw is 90 mA (standby) and will momentarily reach 140 mA (peak).
The power source should be linear or a good quality switched-mode power supply. The performance of the reader may be aff ected by a low quality, noisy power supply.
Cabling
The Gallagher T11 Reader requires a minimum cable size of 4 core 24 AWG (0.2 mm
2
) stranded security cable. This cable allows the transmission of data (2 wires) and power (2 wires). When using a single cable to carry both power supply and data, both the power supply voltage drop and data requirements must be considered. Although the reader is specifi ed to operate at 9 Vdc, for good engineering design it is recommended that the voltage at the reader should be approximately 12 Vdc.
Examples of approved cables for connec ng a single Gallagher T11 Reader to a Controller and power supply, showing maximum cable lengths for each type of cable and the associated circuits are:
Manufacturer
reference Cable format*
Combined power and data in a single cable
Data only in a
single cable
CAT5E 4 twisted pair
Each 2 x 0.2 mm2 (24 AWG)
100 m (330  ) 300 m (1000  )
SEC472 4 x 0.2 mm
2
Not twisted pairs (24 AWG)
100 m (330  ) 250 m (800  )
SEC4142 4 x 0.4 mm
2
Not twisted pairs (21 AWG)
150 m (500  ) 150 m (500  )
BELDEN 8723 2 twisted pair
Each 2 x 0.4 mm
2
(22 AWG)
100 m (330  ) 150 m (500  )
BELDEN 9842 2 twisted pair
Each 2 x 0.2 mm2 (24 AWG)
100 m (330  ) 200 m (650  )
Page 3
Gallagher T11 Reader
Installa on Note
Part Number: 3E2513 | Edi on 10 November 2012
* The matching of wire sizes to equivalent wire gauges are only approximate.
Grounding shielded cable may reduce the obtainable cable length by 25% to 30%.
Distance between Proximity Readers
The distance separa ng any two proximity readers must not be less than 200 mm (8 inches) in all direc ons.
200 mm
When moun ng a proximity reader on an internal wall, check that any reader fi xed to the other side of the wall is not less than 200 mm (8 inches) away.
200 mm
InstallaƟ on
The Gallagher T11 Reader is designed to be mounted on ver cally orientated electrical fl ush (gang) boxes, or any solid fl at surface. However installa on on metal surfaces, par cularly those with a large surface area will reduce read range. The extent to which the range is reduced will depend upon the type of metal used.
The recommended moun ng height for the reader is 1.1 m (3.6  ) from the fl oor level to the centre of the reader device. However this may vary in some countries and you should check local regula ons for varia ons to this height.
1. Ensure the building cable has been run out through the fl ush box.
If you are not moun ng to a fl ush box, use the drill template at the back of this installa on note as a guide, to drill all fi ve holes. Drill the 13 mm (1/2 inch) diameter centre hole (this is the centre hole for which the building cable will exit the moun ng surface) and the four fi xing holes.
2. Run the building cabling through the reader base.
3. Secure the base to the fl ush box using the two 6-32 UNC screws provided. It is important the base of the reader is fl ush with and  ght against the moun ng surface.
Page 4
Gallagher T11 Reader
Edi on 10 | Part Number: 3E2513
November 2012
Installa on Note
If you are not moun ng to a fl ush box, secure the base to the moun ng surface using the four fi xing screws provided.
Base
6-32 UNC screw
Building cable
6-32 UNC screw
4. Connect the reader tail extending from the facia assembly to the building cable. Connect the wires shown below.
Note: Do not cut the ‘Reserved’ wires, as these may be used for future func ons.
Posi ve Red Nega ve Black Reserved Orange Reserved Green Reserved Brown CDXIV TX White CDXIV RX Blue
Cardax IV Reader
5. Fit the facia assembly into the base by clipping the small lip, into the top of the base and holding the top, press the bo om of the facia assembly down into the base.
6. Insert the M3 Torx Post Security screw (using a T10 Torx Post Security screwdriver) through the hole at the bo om of the base to secure the facia assembly.
Note: The Torx security screw needs only to be lightly  ghtened. The recommended torque for the security screw is 0.7 Nm (0.5 lb/ ). It is important not to exceed the maximum torque of 1.5 Nm (1.1 lb/ ).
Page 5
Gallagher T11 Reader
Installa on Note
Part Number: 3E2513 | Edi on 10 November 2012
Fit screw to secure facia to base
Facia
Reader
tail
Connec on
7. Removal of the facia assembly is a simple reversal of these steps.
ConnecƟ ons
A Gallagher T11 Reader can connect to one of the following devices using the “Cardax IV Reader” communica ons protocol:
Gallagher Reader Module (for the Controller 6000)
Gallagher GBUS Universal Reader Interface (Gallagher GBUS URI)
Gallagher Controller 3000-4R or 3000-8R
Gallagher Universal Reader Interface (Gallagher URI)
Gallagher Reader I/O Interface
Page 6
Gallagher T11 Reader
Edi on 10 | Part Number: 3E2513
November 2012
Installa on Note
ConnecƟ ng to the Gallagher Reader Module (for the Controller 6000)
Connect the wires to the sockets as shown:
-
+
R1 Out
R1 In
C12
3
C45
6
R2 Out
R2 In
Gallagher Reader Module
Nega ve Black Posi ve Red Reserved Orange Reserved Green Reserved Brown CDXIV RX Blue CDXIV TX White
Cardax IV Reader 1
Nega ve Black Posi ve Red Reserved Orange Reserved Green Reserved Brown CDXIV RX Blue CDXIV TX White
Cardax IV Reader 2
ConnecƟ ng to the Gallagher GBUS Universal Reader Interface
Connect the wires to the sockets as shown in either of the following diagrams:
RLY 2 COM
RLY 2 NO
RLY 2 NC
DATA 0
DATA 1
OUT 1
OUT 2
COM A
COM B
TAMPER
GND
VOUT
GND
VIN
GND
Pin 15
Reader
Top Row
Pin 1
Gallagher GBUS URI
Posi ve Red
Nega ve Black
Reserved Orange
Reserved Green
Reserved Brown
CDXIV TX White
CDXIV RX Blue
Cardax IV Reader
RLY 2 COM
RLY 2 NO
RLY 2 NC
DATA 0
DATA 1
OUT 1
OUT 2
COM A
COM B
TAMPER
GND
VOUT
GND
VIN
GND
Pin 15
Reader
Top Row
Pin 1
Gallagher GBUS URI
Posi ve Red
Nega ve Black
Reserved Orange
Reserved Green
Reserved Brown
CDXIV TX White
CDXIV RX Blue
Cardax IV Reader
Page 7
Gallagher T11 Reader
Installa on Note
Part Number: 3E2513 | Edi on 10 November 2012
ConnecƟ ng to the Gallagher Controller 3000-4R or 3000-8R
The ports to which the Gallagher T11 Reader can connect are set up as groups, as follows:
Two groups (numbered 1 and 2) on the Controller 3000-4R, and
Four groups (numbered 1 to 4) on the Controller 3000-8R
Each group provides connec on for two Gallagher T11 Readers. Refer to the following diagram for the loca on of the ports on the Gallagher Controller 3000-8R.
81
OPEN
COMM
NCNO
COIL
COMM
NCNO
COIL
COMM
NCNO
COIL
COMM
NCNO
COIL
COMM
NCNO
COIL
COMM
NCNO
COIL
COMM
NCNO
COIL
COMM
NCNO
COIL
96
51
P4
HAMILTON, NEW ZEALAND
GGL ASSY 2A0203
GGL PCB 2M8170-0
CDX PCB 22920 V0
(c)2002 CARDAX (INTERNATIONAL) LTD
P3
P1
COMA
P2
SW
P4
PF4
PF3
PF2
PE4
PE3
PE2
COM
COM
CO
M
COM
NO NO NO NO
NC NC NC NC
COM
CO
M
COM
COM
NO NO NO NO
NC
NC
NC
NC
PF1 PE1
P1
0V
VIN
COMB
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
1
1
2
DETECTOR
LED
RS485
POWER
IN
J4
J3
J2
J1
0V
0V
0V
0V
VOUT
VOUT VOUT VOUT
PA4
PA3
PA2
PA1
2
1
2
1
2
1
2
1
PA4
POWER
OUT
PA3
POWER
OUT
PA2
POWER
OUT
PA1
POWER
OUT
COMB
OUT2
COMA
OUT1
DATA1 DATA1 DATA1 DATA1
DATA0 DATA0 DATA0 DATA0
PB4
PB3
PB2
PB1
2
3
1
4
2
3
1
4
2
3
1
4
2
3
1
4
COMA
OUT1
COMA
OUT1
COMA
OUT1
COMB
OUT2
COMB
OUT2
COMB
OUT2
2
3
1
IN2 IN2 IN2 IN2
GND
IN1 IN1 IN1 IN1
PC4
PC3
PC2
PC1
2
3
1
2
3
1
2
3
1
GND
GND
GND
IN4 IN4 IN4 IN4
GND
IN1 IN1 IN1 IN1
PD4
PD3
PD2
PD1
2
3
1
2
3
1
2
3
1
GN
D
GND
GND
PC1
PC2
PC3
PC4PD4
PD3
PD2
PD1
PA1 to PA4 Power Out
pin 1 = power out pin 2 = 0 V
Group 4
Group 3
Group 2
Group 1
PB1 to PB4
2 x Cardax IV Readers per connector
Reader 1 = pins 1 & 3 Reader 2 = pins 2 & 4
Pin 1 = Reader 1 transmit Pin 2 = Reader 2 transmit Pin 3 = Reader 1 receive Pin 4 = Reader 2 receive
J1 to J4
RS485
terminating resistors
PC1 to PC4 Inputs
pin 1 = Input 1 pin 2 = Ground pin 3 = Input 2
Page 8
Gallagher T11 Reader
Edi on 10 | Part Number: 3E2513
November 2012
Installa on Note
Make the connec ons from the Gallagher T11 Reader to either the Gallagher Controller 3000-4R or 3000-8R as shown:
PB1 and PA1... to... PB2 and PA2 (3000-4R) PB4 and PA4 (3000-8R)
Gallagher Controller 3000-4R or 3000-8R
Group
1 V OUT
2 0 V
1 DATA 0
2 DATA 1
3 OUT 1
4 OUT 2
PB
PA
Posi ve Red
Nega ve Black
Reserved Orange
Reserved Green
Reserved Brown
CDXIV TX White
CDXIV RX Blue
Cardax IV Reader
Posi ve Red
Nega ve Black
Reserved Orange
Reserved Green
Reserved Brown
CDXIV TX White
CDXIV RX Blue
Cardax IV Reader
Note: Within each group, you cannot mix Cardax IV Readers with Wiegand Readers. This is because connec ng one Wiegand Reader requires all four pins on plug PB. For example, if you connect a Cardax IV Reader to Port 1 of Group 1, Port 2 of Group 1 can only connect to another Cardax IV Reader.
Page 9
Gallagher T11 Reader
Installa on Note
Part Number: 3E2513 | Edi on 10 November 2012
Technical Specifi caƟ ons
Technical Specifi caƟ ons
Rou ne maintenance: Not applicable for this reader.
Cleaning: This reader should only be cleaned with a clean, lint free,
damp cloth.
Power required: Voltage: 9 Vdc - 16 Vdc
Current (at 12 Vdc): 90 mA (standby) Mifare reader 125 mA (peak) Mifare reader
90 mA (standby) Mul Tech reader 140 mA (peak) Mul Tech reader
Environmental: Temperature Range: -35 °C to +70 °C
Note: Direct sunlight may increase the internal reader temperature above the ambient temperature level.
Humidity: 95% non-condensing
Environmental Protec on: IP68
Impact Ra ng: IK07
Approvals and Standards
This product complies with the environmental regula ons for the Restric on of Hazardous Substances in electrical and electronic equipment (RoHS). The RoHS direc ve prohibits the use of electronic equipment containing certain hazardous substances in the European Union.
This symbol on the product or its packaging indicates that this product must not be disposed of with other waste. Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collec on point for the recycling of waste electrical and electronic equipment. The separate collec on and recycling of your waste equipment at the  me of disposal will help conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more informa on about where you can drop off your waste equipment for recycling, please contact your local city recycling offi ce or the dealer from whom you purchased the product.
ACN 002 132 943
Page 10
Gallagher T11 Reader
Edi on 10 | Part Number: 3E2513
November 2012
Installa on Note
FCC
This device complies with part 15 of the FCC Rules. Opera on is subject to the following two condi ons: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired opera on.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protec on against harmful interference in a residen al installa on. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruc ons, may cause harmful interference to radio communica ons. However, there is no guarantee that interference will not occur in a par cular installa on. If this equipment does cause harmful interference to radio or television recep on, which can be determined by turning the equipment o and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separa on between the equipment and receiver.
- Connect the equipment into an outlet on a circuit diff erent from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Industry Canada
This device complies with Industry Canada licence-exempt RSS standard(s). Opera on is subject to the following two condi ons: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired opera on of the device.
Note: Changes or modifi ca ons not expressly approved by Gallagher Group Limited could void the user’s authority to operate this equipment.
Drill Template
40 mm (1.57 inches)
32 mm (1.26 inches) 48 mm (1.89 inches)
115 mm (4.53 inches)
13 mm (1/2 inch)
diameter hole for cable
70 mm (2.76 inches)
22.5 mm
(0.89 inches)
40 mm (1.57 inches)
Loading...