Galaxy Audio Check-Mate CM-140 Instruction Manual

CM-140
Instruction
Manual
SOUND LEVEL METER
CE
GCBC CM140-12000
GALAXY AUDIO
TITLE PAGE
I. Safety Information………………………….. 1 II. General Description.…………………...…1-2 III. Specifications……………..……………… 2-3 IV. Name and Functions…………………….. 4-5 V. Calibration Procedures………..………... 6-7 VI. Measurement Preparation……..……….… 7 VII. Operating Precautions………..…………. 7-8 VIII. Measurement………………………………... 8
CONTENTS
I. Safety Information
Read the following safety information carefully before attempting to operate or service the meter. Use the meter only as specified in this manual; otherwise, the protection provided by the meter may be impaired.
Ø Environment Conditions Œ Altitude up to 2000 meters Relative humidity 90% max. Ž Operation Ambient 0 to 40
Ø Maintenance & Clearing Œ Qualified personnel should only perform repairs or
servicing not covered in this manual.
Periodically wipe the case with a dry cloth. Do not use
abrasives or solvents on this instrument.
Ø Safety symbols
Comply with EMC When servicing, use only specified replacement
parts.
II. General Description
Thank you for using our Sound Level Meter. To ensure that you can get the most from it, we recommend that you read and follow the manual carefully before use. This unit conforms to the IEC651 type2, ANSI S1.4 Type2 for Sound Level Meters. This Sound Level Meter has been designed to meet the measurement requirements of safety engineers, health, industrial safety offices and sound quality control in various environments.
q Range from 32dB to 130dB at frequencies between
31.5Hz and 8 KHz.
CM-140 SPL METER
1
III. Specifications
Standard Applied: IEC651 Type2, ANSI S1.4 Type2. Frequency Range: 31.5Hz to 8KHz Measuring Level Range: 32dB to 130dB Frequency Weighting: A / C Microphone: 1/2-inch electret condenser microphone Display: LCD Digital Display: 4 digit Resolution: 0.1dB Display Update: 0.5 sec. Time Weighting: FAST (125mS), SLOW (1 sec.) Level Ranges: Lo: 32 dB to 80 dB
Med: 50 dB to 100 dB
Hi: 80 dB to 130 dB
Accuracy: ±1.5dB ( under reference conditions, 94dB@1kHz )
Dynamic Range: 50 dB Alarm Function: “OVER” is when input is more than
upper limit of range. “UNDER” is when input is less than lower
limit of range. MAX / MIN Hold: Hold readings the Maximum and Minimum Value.
q Display with 0.1dB steps on a 4-digit LCD. q Two equivalent weighted sound pressure levels, A and
C.
q AC signal output is available from standard 3.5mm
coaxial socket suitable for a frequency analyzer, level recorder, FFT analyzer, graphic recorder, etc.
2
CM-140 SPL METER