![](/html/80/809a/809a45e6549f65a2fa19a1494fbdf9058464dac266092831080858b00589618b/bg1.png)
Pub. 43003-035B
GAI-TRONICS® CORPORATION
A HUBBELL COMPANY
Model XRM0001A
Navigator Control Module Relay Kit
Field Installation Kit Instructions
Confidentiality Notice
This manual is provided solely as an operational, installation, and maintenance guide and contains
sensitive business and technical information that is confidential and proprietary to GAI-Tronics.
GAI-Tronics retains all intellectual property and other rights in or to the information contained herein,
and such information may only be used in connection with the operation of your GAI-Tronics product or
system. This manual may not be disclosed in any form, in whole or in part, directly or indirectly, to any
third party.
General Information
The Model XRM0001A Control Module Relay Kit is designed for used with the ICP9000 Navigator
Series Console and the XCP0600A Output Control Module Kit. This kit includes the following
components:
Qty Description
1 Output Module, 8-relay
1 Snaptrack, 12-inch
2
The relay output module provides eight Form “C”, dry-contact outputs, each rated to 10 amperes. The
relay circuit board is arranged in two sections of four relays each. Each section had dedicated
connections to its own terminal blocks allowing the two sections to be separated and to operate
independently.
The PC board assembly may be provided in one of two formats:
Screws, #8×3/4-inch
PC Board Assembly, Part No. RIO-8C (or RIO-8-OC)
The Part No. RIO-8C PCBA is fabricated strictly for Open-Collector input control. This configuration
meets the requirements of the Model XCP0600A Output Control Kit and requires no field adjustments or
changes.
GAI-Tronics Corporation P.O. Box 1060, Reading, PA 19607-1060 USA
610-777-1374 800-492-1212 Fax: 610-796-5954
VISIT WWW.GAI-TRONICS.COM FOR PRODUCT LITERATURE AND MANUALS
![](/html/80/809a/809a45e6549f65a2fa19a1494fbdf9058464dac266092831080858b00589618b/bg2.png)
Pub. 43003-035B
Model XRM0001A Navigator Control Module Relay Kit Page: 2 of
PC Board Assembly, Part No. RIO-8
The Part No. RIO-8 PCBA can be configured for either Open-Collector (“OC”) or Logic Level (“LL”)
input control. This unit is factory configured to the “LL” mode of operation, and must be converted to the
“OC” mode for use with the Model XCP0600A Output Control Kit.
Convert the Part No. RIO-8 PCBA by changing the jumper arrangement associated with each relay.
Jumper wires JW1 through JW8 are associated with their respectively numbered relays. Refer to Figure 1
for jumper locations.
Move the jumper from the “LL” position to the “OC” position on each relay being used by the Model
XCP0600A Output Control Kit.
N
OTE: Failure to change the jumper position to “OC” will prevent the unit from functioning.
Installation
3
1. Mount the 12-inch Snaptrack® to the desired surface with the two screws provided in this kit.
2. Snap or slide the relay board into place. Refer to Figure 1 for the interconnection with the Model
XCP0600A (12584-xxx) Output Control Module.
d:\radio products-current release\43003\43003-035b\43003-035b.doc
03/06