General Information
The Model XCP0300A Upgrade Kit for the ICP9000 Navigator consoles includes the firmware and
software necessary for upgrading to the current production features and functionality. This kit is intended
only for use in the ICP9000 Navigator Series MCU. It includes the following components:
Qty Description
1 Master EPROM chip
1 Host EPROM chip
3 Slave EPROM chips
1 Navigator Software CD
1 Programming Bundle CD (includes CARD Suite Software)
1 Navigator Installation/Service Manual
GAI-Tronics Corporation 400 E. Wyomissing Ave. Mohnton, PA 19540 USA
610-777-1374 800-492-1212 Fax: 610-796-5954
V
ISIT WWW.GAI-TRONICS.COM FOR PRODUCT LITERATURE AND MANUALS
Pub. 43003-031D
Model XCP0300A Navigator Upgrade Kit Page: 2 of
Installation
ICP9000 Navigator Series MCU
1. Disconnect power from the ICP9000 Navigator Series MCU and remove all attached cables from the
rear panel.
2. Remove the 10 screws securing the side cover panel and gently lift the cover off. See Figure 1.
3. On each slave PCBA (CP-CSD) locate U502 EPROM socket and extract the EPROM.
4. Replace them with the Slave EPROM (SLAV**) provided in this kit, taking care to observe the
direction indicated on the socket of the EPROM. Ensure that the chip is properly seated in the socket.
5. Disconnect the ribbon cables (SLV-CBL-M) attached to the Main PCBA.
3
6. Remove the 4 screws holding the inner PCBA mounting plate to the main enclosure.
7. Disconnect the (SLV-CBL-P) cables from the surge suppression PCBAs. This allows you to remove
the inner PCBA mounting plate to gain access to the main PCBA. Refer to Figure 1.
f:\radio products-draft\gtc 43003\43003-031d\43003-031d.doc
12/10
Figure 1.