Pub. 43003-024A
GAI-TRONICSĀ® CORPORATION
A HUBBELL COMPANY
Model XCP0120A Slave Cable Assembly
Replacement Kit
Field Installation Kit Instructions
Confidentiality Notice
This manual is provided solely as an operational, installation, and maintenance guide and contains
sensitive business and technical information that is confidential and proprietary to GAI-Tronics.
GAI-Tronics retains all intellectual property and other rights in or to the information contained herein,
and such information may only be used in connection with the operation of your GAI-Tronics product or
system. This manual may not be disclosed in any form, in whole or in part, directly or indirectly, to any
third party.
General Information
The Model XCP0120A Slave Cable Assembly Replacement Kit contains a set of ribbon cables used to
replace damaged cables within an ICP9000 Series Desktop Console.
This kit includes the following components:
Qty Description
1 SLV-CBL-M Interconnecting cable (for master PCBA to CSD PCBA)
1 SLV-CBL-P Interconnecting cable (for CSD to CLP PCBAs)
Installation
1. Disconnect the power from the ICP9000 Series Desktop Console.
2. Remove the 7 screws securing the top panel and gently lift the cover to expose the attached speaker
cable and master display cable. See Figure 1.
3. Disconnect the speaker cable at the male to female connection point. Unplug the master display cable
from the top cover. Also unplug the ESD ground wire from the front panel quick-disconnect lug.
4. The exposed cable(s) in the front is the SLV-CBL-M, going from the main PCBA to the CSD PCBA.
Remove the damaged cable from the connector plug by squeezing the metallic latch catches on the
sides and pulling.
Page 1 of 2
Pub. 43003-024A
Model XCP0120A Slave Cable Assembly Replacement Kit Page: 2 of 2
Figure 1.
5. Connect the new SLV-CBL-M ribbon cable to J1 and route it under the cable slot nearest the
mounting position.
6. The exposed SLV-CBL-P cables in the rear run from the CSD PCBA to the CLP PCBA. Remove the
damaged cable from the connector by pulling gently.
7. Connect the new SLV-CBL-P ribbon cable between the CSD board at P25 and the corresponding
CLP board at J25 located in the rear of the unit.
8. Reassemble the front cover using the reverse procedure. Verify the correct ribbon cable positioning
before tightening the slave mid-panel mounting screws to avoid damage to the cable.
9. Reconnect the power to the console.
11/01