GAI-Tronics XCP0040A User Manual

Pub. 43003-015B
GAI-TRONICS® CORPORATION
A HUBBELL COMPANY
Model XCP0040A 4-Channel
E&M Control Kit
Confidentiality Notice
This manual is provided solely as an operational, installation, and maintenance guide and contains sensitive business and technical information that is confidential and proprietary to GAI-Tronics. GAI-Tronics retains all intellectual property and other rights in or to the information contained herein, and such information may only be used in connection with the operation of your GAI-Tronics product or system. This manual may not be disclosed in any form, in whole or in part, directly or indirectly, to any third party.
General Information
The Model XCP0040A 4-Channel E&M Control Kit for the ICP9000 Series Desktop Console or the ICP9000 Navigator MCU allows control of E&M signaling stations and works in conjunction with the Model CP0070A and XCP0070A Supervisor Unit. The kit includes the following components:
Qty Description
1 E&M Control PCBA
Installation
1. Disconnect power from the ICP9000 Series Desktop Console or the ICP9000 Navigator Series Master
Control Unit. Remove the attached cables.
2. Remove the four #4-40 flat-head machine screws from the top and bottom of the cover on the
Supervisory unit. See Figure 1.
3. Remove the four #6-32 pan head machine screws from the Supervisory unit cover.
Note: At this point, the Supervisory unit is held in place solely by its connection to the three DB25 connectors.
GAI-Tronics Corporation P.O. Box 1060, Reading, PA 19607-1060 USA
610-777-1374 n 800-492-1212 n Fax: 610-775-6540
VISIT WWW.GAI-TRONICS.COM FOR PRODUCT LITERATURE AND MANUALS
Pub. 43003-015B
Model XCP0040A 4-Channel E&M Control Kit Page: 2 of 2
4. Remove the two #4-40 screws on the top right of the Supervisory PCBA to add E&M Control to
channels 1 through 4, on the top middle for channels 5 through 8, and on the top left for channels 9 through 12. Refer to the silk screen labeling on the Supervisory cover for clarification.
5. Attach the E&M board to the CES PCBA in the Supervisory unit by inserting the connector pins
through the holes in the board as shown in Figure 1.
6. Replace the #4-40 screws that you originally removed from the CES board in order to secure the
E&M Control PCBA. Insert the screws through both boards and tighten until snug.
7. Replace the Supervisory unit’s cover along with the four #6 × 32 screws and the four #4 × 40 screws,
and reattach all cables. Reconnect the power.
8. Refer to the CARD Suite Software (XAC1000A) for the specific programming instructions for
reconfiguration.
11/02
Figure 1.
Loading...