Pub. 43003-015B
GAI-TRONICS® CORPORATION
A HUBBELL COMPANY
Model XCP0040A 4-Channel
E&M Control Kit
Field Installation Kit Instructions
Confidentiality Notice
This manual is provided solely as an operational, installation, and maintenance guide and contains
sensitive business and technical information that is confidential and proprietary to GAI-Tronics.
GAI-Tronics retains all intellectual property and other rights in or to the information contained herein,
and such information may only be used in connection with the operation of your GAI-Tronics product or
system. This manual may not be disclosed in any form, in whole or in part, directly or indirectly, to any
third party.
General Information
The Model XCP0040A 4-Channel E&M Control Kit for the ICP9000 Series Desktop Console or the
ICP9000 Navigator MCU allows control of E&M signaling stations and works in conjunction with the
Model CP0070A and XCP0070A Supervisor Unit. The kit includes the following components:
Qty Description
1 E&M Control PCBA
Installation
1. Disconnect power from the ICP9000 Series Desktop Console or the ICP9000 Navigator Series Master
Control Unit. Remove the attached cables.
2. Remove the four #4-40 flat-head machine screws from the top and bottom of the cover on the
Supervisory unit. See Figure 1.
3. Remove the four #6-32 pan head machine screws from the Supervisory unit cover.
Note: At this point, the Supervisory unit is held in place solely by its connection to the three DB25
connectors.
GAI-Tronics Corporation P.O. Box 1060, Reading, PA 19607-1060 USA
610-777-1374 n 800-492-1212 n Fax: 610-775-6540
VISIT WWW.GAI-TRONICS.COM FOR PRODUCT LITERATURE AND MANUALS
Pub. 43003-015B
Model XCP0040A 4-Channel E&M Control Kit Page: 2 of 2
4. Remove the two #4-40 screws on the top right of the Supervisory PCBA to add E&M Control to
channels 1 through 4, on the top middle for channels 5 through 8, and on the top left for channels 9
through 12. Refer to the silk screen labeling on the Supervisory cover for clarification.
5. Attach the E&M board to the CES PCBA in the Supervisory unit by inserting the connector pins
through the holes in the board as shown in Figure 1.
6. Replace the #4-40 screws that you originally removed from the CES board in order to secure the
E&M Control PCBA. Insert the screws through both boards and tighten until snug.
7. Replace the Supervisory unit’s cover along with the four #6 × 32 screws and the four #4 × 40 screws,
and reattach all cables. Reconnect the power.
8. Refer to the CARD Suite Software (XAC1000A) for the specific programming instructions for
reconfiguration.