General Information
GAI-Tronics Corporation offers intrinsically-safe (I.S.) telephones and isolation barrier units (IBU),
which conform to all pertinent requirements in the USA and Canada. For convenience, a telephone and
an IBU can be purchased together under a single model number: Model 261-001 for indoor use, and
Model 271-001 for outdoors.
However, for rack-mount configurations or special applications, the telephones and IBUs can be
purchased separately:
•Model 262-001 Indoor I.S. Phone
•Model 272-001 Outdoor I.S. Phone
•Model 263 Isolation Barrier Unit
The I.S. telephones are designed to be installed in all hazardous areas. The IBU or rack-mount card unit
is placed in a non-hazardous area up to one mile from the phone, limiting the energy levels going to the
hazardous area to conform to intrinsically-safe requirements.
The Model 263 Isolation Barrier Unit is constructed of durable glass-reinforced polyester, which is highly
resistant to chemicals and weather, and is rated Type 3R (rainproof).
GAI-TRONICS 3030 KUTZTOWN RD. READING, PA 19605 USA
610-777-1374 800-492-1212 Fax: 610-796-5954
ISIT WWW.GAI-TRONICS.COM FOR PRODUCT LITERATURE AND MANUALS
V
Pub. 42004-178D
Model 263 Isolation Barrier Unit (IBU) Page: 2 of 13
Installation
Installa tion Guidelines
When installing any GAI-Tronics telephone equipment, please adhere to the following guidelines to
ensure the safety of all personnel:
•NEVER install telephone wiring during a lightning storm.
•Install a UL Listed lightning arrestor on any phone installed where the phone or phone cable is at
ris k of being expos e d to li ghtning s trikes. The lightning arrestor must be installe d as c lose to the
phone as possible to maximize the protection. The lightning arrestor must not be installed within the
enclosure supplied with the phone.
•NEVER install telephone jacks in wet locations unless the jack is specifically designed for we
cations.
lo
•NEVER touch uninsulated telephone wires or terminals unless the telephone line has been
disconnected at the network interface.
•USE CAUTION when installing or modifying telephone lines.
•Install UL Listed telephone line suppressor (customer-supplied) on the telephone line.
•Use silicone sealant or equivalent around and inside all conduit entrie
s
t
Installa tion of the IBU
The Model 263 Isolation Barrier Unit provides an intrinsically-safe circuit when connected in accordance
with GAI-Tronics Pub. 42004-380, Control Drawing 73242. It must be installed in a non-hazardous
location. See Figure 1 for a typical installation.
The Model 263 Isolation Barrier Unit interior includes a power switch selector, a ring pitch adjustment,
and f our troubleshooting LE Ds. The IBU h ousi ng is c omposed of two modular suba ssemblies, th e front
panel and the rear enclosure assembly, for easy installation and wiring.
gure 1. Typical in trin sic ally-safe installation
Fi
\\s_eng\gtc proddoc s \st andard iom s - current releas e\ 42004 ins t r. m anuals \ 42004-178d. doc
03/06
Pub. 42004-178D
Model 263 Isolation Barrier Unit (IBU) Page: 3 of 13
Wiring Requirements
Design Lim its
In order to be intrinsically safe, energy and energy storage must be constrained to “safe” levels in
hazardous a rea a pparatus. Wiring inherently has capac itance formed by a dielectric material b etwee n two
conduct ors. A buil dup of this capacitance can form a surge of electricit y, a da ngerous s ituation in a
hazardous a rea.
Intrinsically-safe telephones require cabling that will limit the amount of capacitance formed. The
limitation on c able le n gth was set by Underwriter’ s Laboratory (UL) bas e d on t es t res ults . This “worst
case” cable available was found to have a capacitance of 60 picofarads/foot. Therefore, UL set the cable
limitation at one mile, the length at which this worst-case cable capacitance level was still within
acceptable bounds. Cable types with less capacitance have been specified to allow connection distances
over one mile.
For example: GAI-Tronics Model 60059-001 and 60021-301 cables allow connection distances of up to
1.5 miles.
Shiel ded Cable
Where multiple I.S. telephone wires are routed together, shielded cable should be used. The use of
shielded cable prevents cross-talk from occurring between multiple I.S. telephone circuits. The shield
must be grounded to an I.S. ground and connected only at the IBU.
Wiring G uidelin es/Contr ol Drawi ng
The Model 263 provides an intrinsically-safe circuit when installed in accordance with GAI-Tronics Pub.
42004-380, Control Drawing 73242. In addition, the NEC and the CEC provide additional installation
details that are recommended for safe installation.
General Wire Ty pes
24 AWG 22 AWG 20 AWG 19 AWG 18 AWG
Maximum capacitance,
316,800 pF/mile
C (picofarads/mile)
Max imum resist an ce,
271 171 107 85 67
R (ohms /mile )
*Ring signal loss,
-16 -12 -8 -6 -4
decibels (dB/ mile)
*Nominal ring signal is 98 dB @ 10 feet.
\\s_eng\gtc proddoc s \st andard iom s - current releas e\ 42004 ins t r. m anuals \ 42004-178d. doc
03/06
Pub. 42004-178D
Model 263 Isolation Barrier Unit (IBU) Page: 4 of 13
System Setup
GAI-Tronics recommends taking the following steps to ensure a safe and trouble-free installation:
1. Install the Model 263 Isolation Barrier Unit (IBU) and wire it completely, except for the hazardou
a
rea signal wires.
WARNING
The unit must be wired in accordance with Pub. 42004-380, Control
Drawing 73242, to ensure intrinsic safety.
2. Next, temporarily connect the I.S. telephone to the IBU with a short pair of conductors, and operate
the unit by making a test phone call. If any problems are detected, see the Troubleshooting section.
3. Call the I.S. telephone from another telephone, and adjust the
RING PITCH (located on the IB U) t o
the desired pitch. See Figure 2 for location.
4. Disconnect the I.S. telephone and install it in the intended permanent location.
WARNING
The unit must be wired in accordance with Pub. 42004-380, Control
Drawing 73242, to ensure intrinsic safety.
5. Make a call from the I.S. telephone. If any problems are detected, see the Troubleshooting section.
s
\\s_eng\gtc proddoc s \st andard iom s - current releas e\ 42004 ins t r. m anuals \ 42004-178d. doc
03/06
Pub. 42004-178D
Model 263 Isolation Barrier Unit (IBU) Page: 5 of 13
Figure 2. Rear of IBU enclosure with cover removed
\\s_eng\gtc proddoc s \st andard iom s - current releas e\ 42004 ins t r. m anuals \ 42004-178d. doc
03/06