GAI-Tronics 12562-108 User Manual

Pub. 42003-249B
GAI-TRONICS® CORPORATION
A HUBBELL COMPANY
SMART Emergency Telephone PCBA
MODEL 12562-108

Confidentiality Notice

This manual is provided solely as an operation, installation, and maintenance guide and contains sensitive business and technical information that is confidential and proprietary to GAI-Tronics. GAI-Tronics retains all intellectual property and other rights in or to the information contained herein, and such information may only be used in connection with the operation of your GAI-Tronics product or system. This manual may not be disclosed in any form, in whole or in part, directly or indirectly, to any third party.

General Information

The Model 12562-108 SMART Emergency Telephone PCBA Replacement Kit contains a printed circuit board assembly to be used in the following GAI-Tronics RED ALERT
®
emergency telephone models:
392-00x 393-00x 393AL-00x 394AL-00x 396-00x 397-00x 398-00x
Electrostatic Discharge (ESD) Protection:
Your telephone may have an earth ground terminal provision. If so, ensure that it is connected to ground in accordance with all local safety regulations and the National Electrical Code (NEC). Grounding has to be ensured for safe and stable communications. Do not use long and coiled ground wires. Trim ground wires to the required length. Use a star configuration whenever possible.

Installation

Models 393-00x, 393AL-00x, and 394AL-00x

Removing the Old PCBA

1. Use the Model 233-001 Security Screwdriver to remove the four front panel screws, and remove the
panel from the enclosure after disconnecting the telephone line.
2. Disconnect the microphone, speaker, LED indicator, keypad (Model 394AL-00x only), and switch
cable(s) from the PCBA. Record the location of each connection for later reconnection.
GAI-Tronics Corporation 400 E. Wyomissing Ave. Mohnton, PA 19540 USA
610-777-1374 800-492-1212 Fax: 610-796-5954
ISIT WWW.GAI-TRONICS.COM FOR PRODUCT LITERATURE AND MANUALS
V
Pub. 42003-249B
M
ODEL 12562-108 SMART EMERGENCY TELEPHONE PCBA REPLACEMENT KIT Page 2 of 4
3. Disconnect the red and green wires from the telephone line connection on the PCBA. Save the
modular cord.
4. Unscrew the four corner screws from the PCBA. Save the screws.

Installing the New PCBA

1. Align the holes in the four corners of the new PCBA with the standoffs in the telephone, maintaining
proper orientation. See Figure 1 on page 3.
2. Use the screws (from step 4 in the previous section) to secure the PCBA.
3. Reconnect the red (ring) and green (tip) telephone wires to the PCBA.
4. Reconnect the microphone, speaker, LED indicator, keypad (Model 394AL-00x only) and switch
cable(s) to the board.
5. Use the Model 233-001 Security Screwdriver to install the four front panel screws.
Models 397-00x and 398-00x

Removing the Old PCBA

1. Use the Model 233-001 Security Screwdriver to remove the six front panel screws and remove the
panel from its back box after disconnecting the telephone line.
2. Disconnect the microphone, speaker, switches, LED indicator, and keypad cables (Model 398-00x
only) from the PCBA. Record the location of each connection for later reconnection.
3. Disconnect the red and green wires from the telephone line connection on the PCBA. Save the
modular cord.
4. Unscrew the four screws securing the PCBA. Save the screws.

Installing the New PCBA

1. Align the holes in the four corners of the new PCBA with the standoffs in the telephone, maintaining
proper orientation. See Figure 2 on page 4.
2. Use the screws (from step 4 in the previous section) to secure the PCBA.
3. Reconnect the red (ring) and green (tip) telephone wires to the PCBA.
4. Reconnect the microphone, speaker, switches, LED indicator, and keypad cable (Model 398-00x
only) to the board.
5. Use the Model 233-001 Security Screwdriver to install six front panel screws.
f:\standard ioms - current release\42003 kit manuals\42003-249b.doc
02/13
Loading...