Gaggenau CX492611 Product specification sheet

CX 492 611
Stainless steel frame Black glass ceramic Width 36" (90 cm)
Included accessories
1 Cooking sensor for temperature
regulation.
Installation accessories
VA 420 000
Connection strip for combination with other Vario 400 series for
flush mounting. VA 420 010
Connection strip for combination with other Vario 400 series for
surface mounting.
Optional accessories CA 060 600
Cooking sensor for temperature regulation within pots.
GN 232 110
Teppan Yaki plate made of multi-ply material, 13" x 21", GN 1/1. For full surface induction cooktops.
GN 232 230
Teppan Yaki plate made of multi-ply material, 13" x 14, GN 2/3. For full surface induction cooktops.
Combinable with:
AL400791 AI442720 / AI442760 AW442720 / AW442760 AF210791
Good to know:
Wall installations require the hood to 
be as large as the cooktop(s). Island
installations require the hood to be 
larger than the cooktop(s).
Vario 400 series full surface induction cooktop
CX 492
– One large cooking surface – Free positioning of up to 6 items
of cookware
– All sizes and formats of cookware
can be used
– TFT touch display for an intuitive
control of all functions
– Cooking sensor function for
temperature control in pots – Professional cooking functions – Max. power output of up to
5,500 W for large cookware – Precision-crafted 3 mm stainless
steel – For surface mounting with a visible
edge or for flush mounting – Can be combined with other Vario
400 series appliances
Cooking zones
One unique cooking surface allows 
for all sizes and formats of cookware to be used. Up to 6 items of cookware can be placed simultaneously on the cooktop.
Operation
Easy to use color graphic TFT touch display with use indications. Electronic power control in 17 output levels.
Features
Cooking sensor function. Professional cooking function. Dynamic cooking function. Teppan Yaki function. Booster function for pots. Booster function for pans. Keep warm function. Individual pot detection. Cooking timer for each cooking position. Stopwatch. Information key with use indicators. Power management.
Home network integration for digital services (Home Connect) wireless via WiFi. The use of the Home Connect functionality depends on the Home Connect services, which are not available in every country. For further information please check: home-connect.com.
Take into account the appliance weight and additional loads. Additional instructions for flush mounting: Installation is possible in countertops made of stone, synthetics or solid wood. Heat resistant and watertight sealing of the cut edges must be observed. For a suitable heat resistant filler please consult the countertop manufacturer. The groove must be continuous and even, so that uniform placing of the appliance on the gasket is ensured. Do not use discontinuous lining. The joint width may vary due to size tolerances of the combinations and of the countertop cut-out.
If installing several appliances in individual cut-outs allow for a division bar of minimum 2" (50 mm) between the individual cut-outs. Operates with magnetic (induction) iron pots and pans only. For an optimal heat distribution, the use of flat bottom cookware is recommended. The wok pan WP 400 001 cannot be used with this appliance. To insure that the appliance works correctly, the cooktop must be sufficiently ventilated either from the rear or base of the cabinet. Please see the installation instructions for further detail. Appliance can be snapped into the countertop from above. Appliance weight: approx. 77 lb. (35.2 kg).
Rating
Rating: 6,240 W (208 / 220 V) 7,200 W (240 V) Minimum fuse protection: 30 A Electrical: 208 / 220–240 V / 60 Hz Electrical connection:
Hardwire required, 37" cable length. 
Safety
Main switch. Residual heat indicator. Child lock. Safety shut-off. Pause function.
Planning notes
Depending on the type of installation (surface-mounted or flush-mounted), the specific definition of the cut-out must be observed. If combining several Vario 400 series appliances, a connection strip VA 420 must be placed between the appliances. Depending on the type of installation, the corresponding connection strip must be provided. The weight bearing capacity and stability, in the case of thin countertops in particular, must be supported using suitable substructures.
www.gaggenau.com/us Revised: June 2021
Fill with silicone
Longitudinal section
Surface-mount Installation Flush-mount Installation
Cross-section
(526 )
20½"
(B)
⅛" (3)
4⅛" (105)
37" (960)
≥ 1⅜" (35)
≥ 2" (51)
35¾" (908)
≥ 4⅜" (110)
34¹⁵⁄16"
(887 )
±¹⁄
±2
20½" (520)
16
"
19⅜"
(492 )
35¾" (908)
4¼" (108)
20½" (520)
⅛"
(3)
37" (960)
16
"
"
±¹⁄
16
±2
R ⅛" (R 3)
90°
≥ 1⅜" (35)
≥ 2" (51)
A: ⅛" (3.5
≥ 4⅜" (110)
±¹⁄
16
"
34¹⁵⁄
±2
(887 )
"
±¹⁄
16
36"
±2
(914 )
-0.5
)
16
±¹⁄
19⅜"
±2
(492 )
16
"
+¹⁄
16
"
20¹¹⁄
"
+2
(
526 )
+¹⁄16"
"
16
R ³⁄
+1
(R 5 )
(A)
90°
R ⅛" (R 3)
Longitudinal section
1
/8"
(3+1)
1
/2"
(13.5)
Cross-section
⅛"
+1
(3 )
16
"
¹¹⁄ (17)
-0.5
A: ⅛" (3.5 B: Fill with silicone
)
35
34
3
/4" (908)
15
/16" ±1/16"
(887
+1
36"
(914+2)
(520)
19⅜"
(492 )
20¹¹⁄16"
1
/8"
+1
(3
)
-0.5
1
(3.5
)
/8"
1
/2"
±2
)
(13.5)
/16"
⅛"
+1
(3 )
(A)
¹¹⁄16"
(17)
16
"
±¹⁄
±2
16
"
+¹⁄
+2
Numbers indicated inside parenthesis ( ) = mm
www.gaggenau.com/us Revised: June 2021
Loading...