Gaggenau 900791 User Manual

GaggenauOperatingandInstallationInstructions
GaggenauNoticed’utilisationetd’installation
GaggenauInstruccionesdeutilizaciónydemontaje
Extractorhood
AH900761/900791
2
Howtousetheseoperatinginstructions3
Features4
Safetyinstructions5
ReadandSaveTheseInstructions5
Safetynotes6
Operation7
Light7
Fanlevels7
Specialfunctions9
Cleaningandcare10
Lampreplacement12
InstallationInstructions
Importantinformation13
Installation13
Electricalinformation14
Electricalconnection14
Wirediagram15
Installation16
TableofContents
Dearcustomer,
Congratulationonyourdecisiontopurchasean
exclusivekitchenappliancefromGaggenau.
Tomakesureyouwillbeabletouseallfunctionsof
theapplianceasquicklyandsafelyaspossible,we
havetriedtomaketheseoperatinginstructionsas
conciseaspossible.
Pleasekeeptheoperatinginstructionsinasafe
place.
Thesedocumentsalsoincludeinstallation
instructions.Certaininstallationworkmayonlybe
donebyaqualifiedelectrician.Pleasemakesure
thattheseinstructionsarealwaysavailable
wheneverneeded.
Howtousethese
operatinginstructions
3
Features
1Smokescreen
2Controlpanel
3Greasefilter
4Handlestrip
5Viewingwindow
6Activatedcharcoalfilter
7Spacerrail
Thisflatscreenhoodoffersyou:
anoutstandingstainlesssteeldesign,
agoodextractioncapacitywithlittlenoise,
easyoperationandcare,
exhaustorcirculatingairoperationdepending
ontherequirement,
alargenumberofoperatorcontrolfunctions
thankstoelectroniccontroland
variousspecialfunctions(e.g.interval
ventilation).
3
5
4
2
1
7
6
Greasefilter
saturation
display
LightningAfter-
running
Intensive
fanlevel
FanLevel3FanLevel2FanLevel1Motoroff
4
ReadAndSaveTheseInstructions.
WARNING-TOREDUCETHERISKOFFIRE,
ELECTRICSHOCK,ORINJURYTOPERSONS,
OBSERVETHEFOLLOWING:
a.) Usethisunitonlyinthemannerintendedbythe
manufacturer.Ifyouhavequestions,contact
themanufacturer.
b.) Beforeservicingorcleaningunit,switchpower
offatservicepanelandlocktheservice
disconnectingmeanstopreventpowerfrom
beingswitchedonaccidentally.Whenthe
servicedisconnectingmeanscannotbelocked,
securelyfastenaprominentwarningdevice,
suchasatag,totheservicepanel.
CAUTION:
FORGENERALVENTILATIONUSEONLY.DO
NOTUSETOEXHAUSTHAZARDOUSOR
EXPLOSIVEMATERIALSANDVAPORS.
WARNING-TOREDUCETHERISKOFARANGE
TOPGREASEFIRE.
a.) Neverleavesurfaceunitsunattendedathigh
settings.Boiloverscausesmokingandgreasy
spilloversthatmayignite.Heatoilsslowlyon
lowormediumsettings.
b.) AlwaysturnhoodONwhencookingathigh
heatorwhenflambeingfood(i.e.Crepes
Suzette,CherriesJubilee,PeppercornBeef
Flambe’).
c.) Cleanventilatingfansfrequently.Grease
shouldnotbeallowedtoaccumulateonfanor
filter.
d.) Useproperpansize.Alwaysusecookware
appropriateforthesizeofthesurfaceelement.
WARNING-TOREDUCETHERISKOFINJURYTO
PERSONSINTHEEVENTOFARANGETOP
GREASEFIRE,OBSERVETHEFOLLOWING:
a.) SMOTHERFLAMESwithaclose-fittinglid,
cookiesheet,ormetaltray,thenturnoffthe
burner.BECAREFULTOPREVENTBURNS.If
theflamesdonotgooutimmediately,
EVACUATEANDCALLTHEFIRE
DEPARTMENT.
b.) NEVERPICKUPAFLAMINGPAN-Youmay
beburned.
c.) DONOTUSEWATER,includingwetdishcloth
ortowels-aviolentsteamexplosionwillresult.
d.) UseanextinguisherONLYif:
1.YouknowyouhaveClassABC
extinguisher,andyoualreadyknowhowto
operateit.
2.Thefireissmallandcontainedinthearea
whereitstarted.
3.Thefiredepartmentisbeingcalled.
4.Youcanfightthefirewithyourbacktoan
exit.
SafetyInstructions
5
SafetyNotes
$
Donotoperatedamagedappliances.
Isolatetheappliancefromthemainsduringevery
maintenanceoperation.Todothis,switch-offthe
correspondingfuse.
Theappliancemustonlybeconnectedbyan
authorisedspecialist,payingattentiontothe
relevantregulationsofthepowersupplycompanies
andtheregionalconstructionregulations.
Repairsmustbecarriedoutbyauthorised
specialists,thusensuringelectricalsafety.
Observetheassemblyinstructions!
Nowarrantyclaimscanbelodgedintheeventof
damagecausedbyfailuretoobservethese
instructions.
Connectingcablesmustnotcomeintocontactwith
hotcookingsurfaces.
Iftheconnectingcableforthisapplianceis
damaged,thecablemustbereplacedbythe
manufacturerorhiscustomerserviceorasimilarly
qualifiedpersoninordertopreventseriousinjuryto
theuser.
Donotoperatetheextractorhoodwithoutinserted
lamps.Defectivebulbsshouldbereplaced
immediatelytopreventtheremainingbulbsfrom
overloading.
Neveroperatetheappliancewithoutagreasefilter.
Hazardousorexplosivesubstancesandvapours
mustnotbeextracted!
Theuserisresponsibleforexpertuseandthe
perfectconditionoftheappliance.
Onlyeveroperatetheapplianceundersupervision.
Overheatedfatoroilcaneasilycatchfire.Ifyouare
cookingwithfatoroil,e.g.chips,etc.,neverleave
thecookerunattended.
Caution!Over-greasedfiltersareafirerisk!Only
everdeep-fryundertheextractorunderconstant
supervision.Payattentiontocleaningthegrease
filteronaregularbasis.
Firerisk!Donotflambémealsundertheextractor
hood!
Operationoftheextractorhoodaboveahearthfor
solidfuels(coalorwoodetc.)isonlypartly
permitted.
Gasappliancesmayonlybeusedunderthe
extractorhoodwhenpotsandpansareplacedon
them!
Donotoperateallhotplatessimultaneouslyovera
prolongedperiod(max.15minutes)atmaximum
thermalload,otherwisethereisariskofburnsfrom
touchingthehousingsurfacesorariskofdamaging
theextractorhood.Whenoperatingtheextractor
hoodaboveahob,operatethehoodatmaximum
settingifthreeormorehotplatesareonatthesame
time.
Theapplianceisnotintendedforusebyyoung
childrenorinfirmedpersonswithoutsupervision.
Youngchildrenshouldbesupervisedtoensurethey
donotplaywiththeappliance.
Donotletadultsorchildrenoperatetheappliance
unsupervised:
–iftheyarementallyorphysicallyunabletousethe
appliancesafelyandcorrectly,
–iftheydon’thavetheknowledgeandexperience
tousetheappliancesafelyandcorrectly.
Whenchildrenbecomeoldenoughtooperatethe
appliance,itisthelegalresponsibilityofthe
parentsorlegalguardianstoensurethattheyare
instructedinsafepracticesbyqualifiedpersons.
Donotplaceanyheavyobjectsontheappliance.
Donotcleantheappliancewithasteamcleaning
apparatusorwithwaterpressurebecausethis
posesariskofshort-circuits.
Adequateincomingairmustbeensuredifawood,
coal,gasoroilheateroranopenhearthisoperated
inthesameroomastheoneinwhichthehoodis
installed.
Safeoperationispossiblewheneverthepartial
vacuumintheplacewherethefiringequipmentis
installeddoesnotexceed4Pa(0.04mbar).This
canbeachievedwhenevertheairneededfor
combustionisabletoenterthroughopeningsthat
cannotbesealed,forexampleindoors,windows,
incoming/exhaustairwallboxesorothertechnical
means.
Disposeofpackagingmaterialsproperly(see
Installationinstructions).
Thisextractorhoodisdesignedfordomesticuse
only.
Ifmalfunctionsshouldoccur,contactyourdealeror
Gaggenauafter-salesservice.Indoingso,please
specifythemodelnumberconcerned(therating
plateisunderthegreasefilter).
Wecannotbeheldresponsiblefordamage
causedbyfailuretoobservetheseinstructions.
Technicalmodificationsreserved.
6
Operation
Thecontrolpanelisbuiltintothehandlerailofthe
screenslideandislocatedontherighthandside.
Afterinstallation,theunitcanbeoperatedfromthe
front.
Afteractivation,allfunctionselectionkeyswiththe
exceptionoftheOFFkey(„Motoroff")areback-lit
ingreen.
Light
Thelightingcanbeswitchedonoroff,regardless
ofwhethertheextractorisinoperation,bypressing
the0key(seeFig.3).
Fanlevels
Threefanspeedsandoneintensivespeedare
available(seeFig.4).
Yousetthefanlevelrequiredtosuityourneedsby
pressingthefunctionselectorkeys1,2,3orInt.
Thecorrespondingindicatorlamponthecontrol
panellightsup.
Fig.3
Fig.4
ororor
7
TheIntkeyfortheintensivelevelshouldbepressed
whenbrowningandfryinginanopenpan.
(seeFig.5)
Ifyouhaveswitchedonthehoodbyselectingthe
intensivelevel,itwillbeswitchedoffagain
automaticallyafter5minutes.
IfyoupresstheIntkeywhilethehoodisrunningat
fanlevel1,2or3theelectroniccontrolwillswitch
backautomaticallytothepreviouslyselectedfan
levelafter5minutes(seeFig.6).
PresstheOFFkey(motoroff)ifyouwishtoswitch
offtheintensivelevelbefore
the5minuteperiod
haselapsed(seeFig.7).Youcanswitchoffthe
hood’sextractionfunctionatanytimebypressing
theOFFkey(motoroff).
Fig.5
Fig.6
Fig.7
8
Specialfunctions
Intensive:
Youcansetthehoodonintensivefor3,5or
10minutesbysimultaneouslypressingtheIntkey
andthe1,2or3keyandyoucanstorethissetting
(seeFig.8).Whendelivered,theapplianceissetto
fiveminutes,i.e.thecombinationoftheIntkeyand
thekey2.
After-runninglevel:
Youcansetandstoretheafter-runninglevelby
simultaneouslypressingthekeyrandthekey1,2
or3(seeFig.9).
Level2,i.e.thecombinationofthekeyrandthe
key2,aresetatthefactory.
Theafter-runningtimeforallsettingsisten
minutes.Theventilationandlightingfunctions
switchoffautomaticallyafterthistime.
Intervalventilation:
Intervalventilationisaspecialfeatureofthis
appliancewhichactivatesthefanforfiveminutes
everyhour.Youcanactivatethisfunctionby
simultaneouslypressingtheOFFkeyandthe1,2or
3keydependingontherequiredextractioncapacity
(seeFig.10).
Thismodeofoperatingisindicatedbyalternating
Illuminationofthekeyrtogetherwiththe
correspondingfanlevelindicator.
Youcanswitchoffintervalventilationbypressing
thekeyOFF.
Fig.8
Fig.9
Fig.10
Fig.11
oror
oror
oror
9
Cleaningandcare
ThegreasefiltersaturationdisplayFflashesafter
operating30hourstoindicateyouthatyoushould
cleanthegreasefilter(seeFig.2).Itgoeswithout
sayingthatthegreasefiltercanbecleanedatany
time,evenifthegreasefiltersaturationdisplayis
notflashing.
Themetalgreasefilterscanberemovedeasilyfor
cleaning(seeFig.12):
Gripthehandlerailofthegreasefilterandpullthe
greasefiltertowardsyououtoftheunit.
Themetalgreasefilterscanbecleanedinadish-
washeratamaximumtemperatureof65°C
(149°F),whereitshouldbesupportedvertically
to
allowfoodorresiduetodrainoff.
Slightdiscolorationsmayoccurwhencleaning
metalfiltersinadishwasher.
Ifpossible,theinnerpartsofthehousingshouldbe
wipedoutwithhotwaterwhenreplacingthefilters.
Thesoundinsulationmatscanbecleanedeasily.
Avoidusingpointedorroughobjectswhencleaning
them.
Aftercleaningit,re-insertthegreasefilterinthe
hoodinthepositionfromwhereyouremovedit.
Thegreasefiltersaturationdisplayisresetby
pressingtheFkey.Flashingoftheindicatinglamp
goesoff.
Note:
Activatedcharcoalfiltersdonotcontainany
pollutingsubstances.Theycanbedisposedof
throughthenormalrefusecollectionchannels.
Fig.12
Fig.13
Greasefilter
10
Recirculatingairmode
Ifyoudecidedtopurchasethehoodwithcirculating
aircapability,youmustreplacetheactivated
charcoalfilter(optional)afteracertainperiodof
operation(seeFig.14).Ifusedoncedaily,the
charcoalfiltermustbereplacedapproximatelyonce
totwiceannually:Firstremovethegreasefilterfrom
themount.AsshowninFig.14,removethe
activatedcharcoalfilterfromtheextractortowards
youandreplacetheoldonebyanewactivated
charcoalfilter.
SparepartNos.fortheactivatedcharcoalfilter:
forAH900-761
KF900-055
forAH900-791
KF900-090
Viewingwindow
Theviewingwindowconsistingofhardenedglass
shouldbecleanedasneeded.Itcanberemovedin
theupwarddirectionafterpullingoutthesmoke
screen.Theviewingwindowcanbecleanedina
dishwasher.
Cleanthecontrolpanelwithamoistclothanda
littledetergent.
Donotusebrushesorabrasiveagentssuchas
scrubbingcleaners.
Fig.14
Coverstrip
Activated
charcoal
filter
11
Deactivatethewallhood'spowersupplyas
describedonPage4.
Firstremovethegreasefilter.
Detachthelampcoverbyremovingthescrewsthat
securethelampcovertotheinsideofthehousing.
Removethesecuringclipandfirstpullthe
fluorescentlampdownwardsoutoftheplastic
holderandthenhorizontallyoutofthesocket.
Defectivefluorescentlampsmustonlybe
replacedbylampsofthesametype.
Theoriginalsparepart:
forAH900-761
sparepartnumber211406
forAH900-791
sparepartnumber292103
isavailablefromspecialistdealersoryour
Gaggenauafter-salesservice.
Insertthenewfluorescentlampinthesocketso
thatitaudiblyengages.Thenpressthelamp
securelyintotheplasticholderandclosethe
securingclipontotheholder.Thelampisnow
secureagainstdroppingout.
Cleanthelampcoverinmilddetergentandthen
secureitonthehoodagain.
Connecttheunittothepoweragain.
Note:
Asstandard,yourhoodcontainsafluorescenttube
withthecolour„brightwhite".Thisensures
optimumilluminationofyourcookingarea.Ifyou
wishadifferentcolour,youcanorderthecolours
„warmtone"and„Interna”fromyourspecialist
dealer.
Lampreplacement
12
Installation
WARNING-TOREDUCETHERISKOFFIRE,
ELECTRICSHOCK,ORINJURYTOPERSONS,
OBSERVETHEFOLLOWING:
a.) Installationworkandelectricalwiringmustbe
donebyqualifiedperson(s)inaccordancewith
allapplicablecodesandstandards,including
fire-ratedconstruction.
b.) Sufficientairisneededforpropercombustion
endexhaustingofgasesthroughtheflue
(chimney)offuelburningequipmenttoprevent
backdrafting.Followtheheatingequipment
manufacturer’sguidelineandsafetystandards
suchasthosepublishedbytheNationalFire
ProtectionAssociation(NFPA),andthe
AmericanSocietyforHeating,Refrigeration
andAirConditioning(ASHRAE),andthelocal
codeauthorities.
c.) Whencuttingordrillingintowallorceiling,do
notdamageelectricalwiringandotherhidden
utilities.
d.) Ductedfansmustalwaysbeventedtothe
outdoors.
e.) NEVERplaceaswitchwhereitcanbereached
fromatuborshower.
WARNING–TOREDUCETHERISKOFFIRE,USE
ONLYMETALDUCTWORK.
WARNING:
Theapplicableregulationsoftheenergysupply
companiesandtheregionalconstruction
regulationsmustbeobservedwheninstallingthe
hood.
Minimumdistancebetweenelectriccooktopand
bottomedgeofhood:181/2”(47cm)
Minimumdistanceongascooktopsbetweenthe
upperedgeofthegrateandloweredgeofthe
hood:26”(65cm)
Connectionpossibilities
Thewallhoodwasconceivedfortheexhaustairor
airrecirculationmode.Theexhaustaircanbe
routedintoaseparateexhaustairshaftordirectly
intotheopenthroughtheoutsidewall.
Itisnotallowedtopasstheexhaustairintoaflue
orexhaustairchimneythatisinoperationorintoa
shaftthatislinkedtotheheatingbasement.
Consultthechimneysweepresponsibleforyour
districtwheneveryouwishtopasstheexhaustair
intoachimneythatisnotinoperation.
Duringthecourseofplanning,achimneysweep
mustbeconsultedifaroomair-dependenthearth
isoperatedinthesameroomastheoneinwhicha
hoodisoperatedintheexhaustairmode.Adequate
incomingairmustbeensured.Theapplicable
constructionandsafetyregulationsmustbe
observed.
Adequateincomingairmustbeensuredifawood,
coal,gasoroilheateroranopenhearthisoperated
inthesameroomastheoneinwhichthehoodis
installed.
Safeoperationispossiblewheneverthepartial
vacuumintheplacewherethefiringequipment
isinstalleddoesnotexceed4Pa(0.04mbar).
Thiscanbeachievedwhenevertheairneededfor
combustionisabletoenterthroughopeningsthat
cannotbesealed,forexampleindoors,windows,
incoming/exhaustairwallboxesorothertechnical
means.
GroundingInstructions
Theappliancemustbegrounded. Intheeventofan
electricalshortcircuit,groundingreducestherisk
ofelectricshockbyprovidinganescapewirefor
theelectriccurrent.Thisapplianceisequippedwith
acordhavingagroundingwirewithagrounding
plug.Theplugmustbepluggedintoanoutletthatis
properlyinstalledandgrounded.
WARNING–IMPROPERGROUNDINGCAN
RESULTINARISKOFELECTRICSHOCK.
Consultaqualifiedelectricianifthe
groundinginstructionsarenotcompletely
understood,orifdoubtexistsastowhetherthe
applianceisproperlygrounded.
Donotuseanextensioncord.Ifthepowersupply
cordistooshort,haveaqualifiedelectricianinstall
anoutletneartheappliance.
Importantinformation
$
13
Electricalconnection:
Observethespecificationsontheratingplate.The
unitmayonlybeconnectedbyanauthorized
electrician,whoisresponsiblefortheproper
functioningatthetimeofinstallation.
HemustexplainoperationoftheunittotheUser
withreferencetoitsinstructionmanual.
Iftheappliancecannotbedisconnectedcompletely
fromthepowersupplybymeansofanaccessible
plug,thenaswitch,fuseorcircuitbreakerwhich
complieswithlocalcodemustbeinstalled.
TheUsershouldbeinstructedonhowto
disconnecttheapplianceinanemergency.
Notesonrepair:
Iftheappliancedoesnotfunctioncorrectlycheck
thefusesfirst.Ifthepowersupplyisfunctioning
correctlybutyourappliancestilldoesnotwork,
notifyyourGaggenaudealer,whowillprovideyou
withtheaddressantelephonenumberofyour
nearestfactoryauthorizedserviceagentorcontact
GaggenauUSA,+18774GAGGENAU.
Repairsmayonlybecarriedoutbyauthorized
electricianinordertoguaranteethesafetyofthe
appliance.Unauthorizedtamperingwiththe
appliancewillinvalidateanywarrantyclaims.The
appliancemustalwaysbedisconnectedfromthe
powersupplywhenbeingrepaired.
Oldappliancesarenotworthlessrubbish.Valuable
rawmaterialscanbereclaimedbyrecyclingold
appliances.Beforedisposingofyouroldappliance,
renderitunusable.
Youreceivedyournewapplianceinaprotective
shippingcarton.Allpackagingmaterialsare
environmentallyfriendlyandrecyclable.Please
contributetoabetterenvironmentbydisposingof
packagingmaterialsinanenvironmentally-friendly
manner.
Pleaseaskyourdealerorinquireatyourlocal
authorityaboutcurrentmeansofdisposal.
Theextractorhoodcanbeusedinexhaustairor
circulatingairmode.
Alwaysmounttheextractorhoodoverthecentreof
thehob.
Theextractorhoodmustnotbeinstalledovera
solidfuelcooker–apotentialfirehazard(e.g.flying
sparks)–unlessthecookerfeaturesaclosed,non-
removablecoverandallnationalregulationsare
observed.
Thesmallerthegapbetweentheextractorhoodand
hotplates,thegreaterthelikelihoodthatdroplets
willformontheundersideoftheextractorhood.
Additionalinformationconcerninggascookers:
Wheninstallinggashotplates,complywiththe
relevantnationalstatutoryregulations(e.g.in
Germany:TechnischeRegelnGasinstallation
TRGI).
Alwayscomplywiththecurrentlyvalidregulations
andinstallationinstructionssuppliedbythegas
appliancemanufacturer.
Onlyonesideoftheextractorhoodmaybeinstalled
nexttoahigh-sidedunitorhighwall.Gapatleast
2”.
Importantinformation
$
14
15
Wirediagram
AH900761
AH900791