PANEL CONVECTOR HEATERS
INSTALLATION INSTRUCTIONS AND USER GUIDE
PH075 AND PH075T RATING 750 W 230 – 240 V~
PH150 AND PH150T RATING 1500 W 230 – 240 V~
PH200 AND PH200T RATING 2000 W 230 – 240 V~
Before connecting the unit for the first time, please, read
these instructions carefully.
1.- IMPORTANT INFORMATION
x The warranty of the panel heater will not cover any damage
caused by non observance of any of these instructions.
x This Guide must be kept and given to any new owner.
x Check that the voltage shown on the rating plate on the heater is
the same as the voltage of the supply to which connection is to be
made.
x Should the heater be moved and reinstalled it is essential that the
work is carried out by a competent electrician.
x The use of panel heaters is forbidden in any area where there is a
presence of gases, explosives or inflammable objects.
x Do not use this heater to dry clothes.
x Neither the connecting cable nor any other object must come into
contact with the hot unit.
x Do not cover this heater at any time.
x The surfaces of this heater can be hot, so young children should
not be left unsupervised in the vicinity of the heater.
x The air outlet grill at the top of the heater cabinet and the air inlet
at the bottom of the heater are provided to ensure the most efficient operation of the appliance. They also protect the heater from
overheating, therefore, it is essential that at no time are they covered.
x This heater should be disconnected from the electricity supply
before any repair work is carried out. This action should also be
taken during the times of the year when heat is not required.
x The panel heater should not be installed just below an electrical
socket.
x The appliance must be installed in such a way that switches and
other control devices cannot be touched by a person using a bath
or shower.
x The installation must be carried out in accordance with the current
electrical regulations.
x The heater is fitted with a flexible cable size 3 x 1.00 mm2 for
electrical connection. It may be used to connect the heater to the
fixed wiring of the premised through a suitable connection box positioned adjacent to the panel heater.
x This appliance must be connected to the supply by fixed wiring.
The supply circuit to the heater must incorporate a double pole
isolating switch having a contact separation of at least 3 mm.
x If the flexible power cable for this unit is damaged, it may only be
replaced by a repair workshop recognised by the manufacturer, as
special tools are necessary.
x This appliance must be earthed.
x Before carrying out any work inside the appliance, the panel heater
must be disconnected from the electricity supply.
x The presence in the air of particles of smoke, dust and other
pollutants could, in time, discolour the walls and surfaces around
the panel heater.
x Please complete the enclosed warranty card and return it to the
manufacturer to enable registration to take place.
x All models are supplied with an electrical interrupt cut-out. This will
switch off the heater if, for any reason, it overheats. Should the cutout operate, turn the heater off and remove the cause for the overheating. The cut-out will be reset automatically.
2.- Installation instructions
- When positioning the heater for installation it is important that a minimum clearance of 50 cm must be allowed between the heater and any
combustible materials, such as furniture, curtains etc, to ensure the best
heating results.
Fig. 1
- Open the carton at the indicated side. The screws are in the accessories
bag. Turn the carton upside down to allow the heater to stand. Check that
it is the correct model and that it is in good condition.
- Fix the two square brackets to the back of the heater by using the two
small screws (see Fig. 1).
41.0 cm ( 750W)
56.0 cm (1250W)
63.5 cm (1500W)
78.5 cm (2000W)
8cm
10cm
min 20cm min 20cm
min 15cm min 15cm
- Position and fix the top bracket at the correct distance from the floor
(see Fig. 2) and hang the unit on the hooks of the top bracket. Mark the
fixing points on the wall using a pencil. Use the heater fixing holes as a
template and mark the wall through the two fixing holes in the square
brackets. Fix the heater to the wall.
Fig. 2
41.0 cm

3.- Using the panel heater.
NON TIMER MODELS
Open the hinged controls cover to access the controls. After adjustment the control
cover closes automatically.
Switch on the heater by setting one of the two switches marked I-O to “ I “. The off
position is marked “ O “.
You can select half heat or full heat by setting only one of the switches marked I-O to
“ I “ or by setting the two ones (this feature is not available on 750W models). When the
heater is generating heat the neon indicator on the switch will be illuminated.
The heater is fitted with an adjustable thermostat, which enables room temperature to
be controlled by adjusting the setting accordingly. Turn the thermostat control to the
maximum (fully clockwise) to heat the room rapidly. When the desired temperature has
been reached, turn the thermostat control slowly to the left (anti-clockwise) until the
luminous indicator switches off. By leaving in this position, the heater will automatically
maintain the selected temperature.
TIMER MODELS
If the slide switch marked I -O- is set to the position marked “ I “ the
heater will be always on, under the control of the thermostat as a non timer
model.
If the slide switch marked I -O- is set to the position marked “O “ the
heater will be in the off position.
If the slide switch marked I -O- is set to the position marked “ “ the
heater will operate automatically. Set the timer by rotating the dial clockwise
until the correct time is indicated opposite the datum mark. Pull the appropriate segments out to set the desired programme. This programme will repeat
itself every day. The timer may be set to give as many “on” periods of any
length as may be required.
The switch marked I – II provides a choice of half heat or full heat. (not
available on 750W models). When the heater is generating heat the neon
indicator on the switch will be illuminated.
3.- Cleaning and maintenance.
Clean and dust with a dry, soft cloth only when the unit is disconnected and
cold. Do not use solvents or abrasive products for cleaning.
4.- Wiring
The symbol on the product or in its
packaging indicates that this product may not
be treated as household waste. Instead it shall
be handed over to the applicable collection
point for the recycling of electrical and electronic equipment. By ensuring this product is
disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise
be caused by inappropriate waste handling of
this product. For more detailed information
about recycling of this product, please contact
your local city office, your household waste
disposal service or the shop where you purchased the product. These instructions are only
valid in the EU member states.
PH-125T
PH-150T
PH-200T
PH-125
PH-150
PH-200
PH-075T
PH-075
T: 24h Timer
E1: Element 1
E2: Element 2
S: Safety cut out
C: Switch
L: Luminous indicator
Ta: Ambient thermostat
Brown : Live
Blue : Neutral
Green and Yellow : Earth