Gabarron IGB12MB-K3DNB7G, IGB09MB-K3DNB7G, IGB18MC-K3DNB7G Owner's Manual

Air Conditioner
Owner's Manual
MODELO:
IGB18MC-K3DNB7G
Split Air Conditioner
Thank you for choosing our product.
If you have lost the Owner’s Manual, please contact the local agent or visit www.elnur.es or sent email to elnur@elnur.es for electronic version.
For proper operation, please read and keep this manual carefully.
Content
Operation Notices
Precautions............................................................................................................1
Parts name ............................................................................................................6
Screen Operation Guide
Buttons on remote controller .................................................................................7
Introduction for icons on display screen ................................................................7
Introduction for buttons on remote controller .........................................................8
Function introduction for combination buttons ......................................................12
Operation guide ....................................................................................................13
Replacement of batteries in remote controller ......................................................13
Emergency operation ..........................................................................................14
Maintenance
Clean and maintenance.......................................................................................14
Malfunction
Malfunction analysis ............................................................................................17
Installation Notice
Installation dimension diagram ............................................................................21
Tools for installation .............................................................................................22
Selection of installation location ..........................................................................22
Requirements for electric connection ..................................................................23
Installation
Installation of indoor unit......................................................................................24
Installation of outdoor unit ...................................................................................29
Vacuum pumping .................................................................................................32
Leakage detection ...............................................................................................32
Check after installation ........................................................................................33
Test and operation
Test operation ......................................................................................................33
Attachment
.........................................................................34
Pipe expanding method .......................................................................................36
This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from un­controlled waste disposal, recycle it responsibly to promote the sustainable reuse of mate­rial resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for envi­ronmental safe recycling.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
Precautions
WARNING
Do not connect air conditioner to multi-purpose socket.
This appliance can be used by children aged from 8
Operation and Maintenance
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
Do not spray water on indoor unit. It may cause electric shock or malfunction.
Otherwise, it may cause fire hazard.
Children shall not play with the appliance. Cleaning and user maintenance shall not be made by
children without supervision.
years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
Do not wash the air conditioner with water to avoid electric shock.
After removing the filter, do not touch fins to avoid injury. Do not use fire or hair dryer to dry the filter to avoid
deformation or fire hazard.
Do disconnect power supply when cleaning air conditioner. Otherwise, it may cause electric shock.
.
1
Do not block air outlet or air inlet. It may cause malfunction.
remote controller may be broken.
Power cord is overheating or damaged.
There’s abnormal sound during operation.
Circuit break trips off frequently.
Air conditioner gives off burning smell.
Indoor unit is leaking.
contact the dealer or qualified professionals for service.
When turning on or turning off the unit by emergency operation switch, please press this switch with an insulating object other than metal.
outlet. It may cause personal injury or damage.
Precautions
WARNING
conditioner and disconnect power immediately, and then
If the air conditioner operates under abnormal conditions, it may cause malfunction, electric shock or fire hazard.
Do not spill water on the remote controller, otherwise the
electric shock or damage. Please contact dealer when you need to repair air conditioner.
Do not repair air conditioner by yourself. It may cause
objects. It may cause damage or personal injury.
Do not step on top panel of outdoor unit, or put heavy
When below phenomenon occurs, please turn off air
Do not extend fingers or objects into air inlet or air
Maintenance must be performed by qualified professionals. Otherwise, it may cause personal injury
or damage.
2
Do install the circuit break. If not, it may cause malfunction.
of at least 3mm in all poles should be connected in fixed wiring.
magnet buckle
and heating buckle function, it can protect
the circuit-short and
overload.
power supply circuit and circuit break.
Precautions
WARNING
note
the following table.Air switch should be included
Make sure the power supply matches with the requirement of air conditioner.Unstable power supply or incorrect wiring or malfunction. Please install proper power supply cables before using the air conditioner.
An all-pole disconnection switch having a contact separation
Must follow the electric safety regulations when installing the unit.
grounding wire of power socket.
Properly connect the live wire, neutral wire and
any work related to electricity and safety.
Be sure to cut off the power supply before proceeding
Including an circuit break with suitable capacity, please
Air Conditioner should be properly grounded. Incorrect
Don't use unqualified power cord.
grounding may cause electric shock.
According to the local safety regulations, use qualified
Installation must be performed by qualified professionals. Otherwise, it may cause personal injury or damage.
Attachment
3
Installation must be performed in accordance with the
persons in order to avoid a hazard.
must be properly grounding with specialized grounding device by a professional. Please make sure it is always grounded effectively, otherwise it may cause electric shock.
The appliance must be positioned so that the plug is accessible.
If the length of power connection wire is insufficient, please contact the supplier for a new one. Avoid extending the wire by yourself.
All wires of indoor unit and outdoor unit should be connected by a professional.
national wiring regulations.
requirement of NEC and CEC by authorized personnel only.
Precautions
WARNING
wire, which can't be used for other purposes.
The grounding resistance should comply with national electric safety regulations.
The air conditioner is the first class electric appliance. It
keep the interconnection cable away from the copper tube.
The temperature of refrigerant circuit will be high, please
the manufacturer, its service agent or similarly qualified
If the supply cord is damaged, it must be replaced by
The yellow-green wire in air conditioner is grounding
The appliance shall be installed in accordance with
Do not put through the power before finishing installation.
4
The indoor unit should be installed close to the wall.
reachable after finishing installation.
far away from animals or plants.If it is unavoidable, please add the fence for safety purpose.
Precautions
WARNING
place, only the qualified person can perform the work. Otherwise, it may cause personal injury or damage.
If you need to relocate the air conditioner to another
must be installed in the line.
For the air conditioner without plug, an circuit break
Select a location which is out of reach for children and
For the air conditioner with plug, the plug should be
Working temperature range
NOTICE:
Indoor side DB/WB(°C) Outdoor side DB/WB(°C)
Maximum cooling 32/23 43/26
Maximum heating 27/- 24/18
The operating temperature range (outdoor temperature) for cooling is -15~43; Heating temperature range for the model without electric heating belt for chassis is -15~24 Heating temperature range for the model with electric heating belt for chassis is -20~24 .
5
(Display content or position may be different from above graphics, please refer to actual products)
Outdoor Unit
air inlet
air outlet
Connection wire
Parts name
Indoor Unit
air inlet
panel
aux.button
horizontal louver air outlet
heating indicator
temp. indicator
cooling indicator
power indicator
receiver window
drying indicator
display
remote control
NOTICE:
Actual product may be different from above graphics, please refer to actual products.
6
Buttons on remote controller
Introduction for icons on display screen
1 ON/OFF button
2 MODE button
3 +/- button
4 FAN button
5 button
8 X-FAN button
9 TEMP button
10 TIMER button
11 TURBO button
12 SLEEP button
13 LIGHT button
7 CLOCK button
6 TIMER ON button
Up & down swing
Child Lock
set time
TIMER ON/TIMER OFF
turbo mode
set temperature
X-fan
send signal
set fan speed
light
Temp. display type
:Set temp.
:Outdoor ambient temp.
:Indoor ambient temp.
Sleep mode
Heat mode
Fan mode
Dry mode
Cool mode
Auto mode
Operation mode
air mode
ON/OFF
MODE
FAN
X-FAN
TURBO
TEMP
TIMER OFF
SLEEP
LIGHT
2
5
6
10
13
12
11
9
8
3
4
7
1
TIMER ON
CLOCK
7
After selecting auto mode, air conditioner will operate automatically according to ambient temperature. Set temperature can’t be adjusted and also can’t be displa­ yed. Press "FAN" button can adjust fan speed. Press
" "
button can adjust
swing angle.
After selecting cool mode, air conditioner operates under cool mode. Cool indicator
" " on indoor unit is ON. You can press "+" or "-" button to adjust set temperature.
Press "FAN" button can adjust fan speed. Press
" "
button can adjust swing
angle.
After selecting dry mode, air conditioner operates under dry mode at low speed. Dry indicator
" "
on indoor unit is ON. Under dry mode, fan speed can’t be ad-
justed. Press
" "
button to adjust swing angle.
After selecting fan mode, air conditioner operates only under fan mode, All mode indicators on indoor unit is OFF. Operation indicator is ON. Press
"FAN" button can
adjust fan speed. Press
After selecting heat mode, air conditioner operates under heat mode. Heat indicator "
" on indoor unit is ON. You can press "+" or "-" button to adjust set temperature
.
Press "FAN" button to adjust fan speed. Press " " button to adjust swing angle
(Cooling only unit can’t receive the signal for heating mode.)
Introduction for buttons on remote controller
Note:
After putting through power, air conditioner will give out a sound and operation indicator " " is ON (red indicator). You can operate the air conditioner through the remote controller.
At ON status, after each pressing button on remote controller, the signal icon " "
indicates the signal has been sent to air conditioner.
At OFF status, display screen on remote controller displays set temperature. At on status, display screen on remote controller displays the corresponding startup
function’s icon.
ON/OFF button
MODE button
1
2
Press this button can turn on or turn off the air conditioner. After turning on the unit, operation indicator " " on indoor unit is ON (green indicator. Color may be differ­ent for different models)and indoor unit gives out a sound.
Press this button can select your required operation mode.
AUTO COOL FANDRY HEAT
" "
button to adjust swing angle.
8
Introduction for buttons on remote controller
"+"
or "-" button
FAN button
3
4
5
After each pressing of "+" or "-" button, it can increase or decrease set temper-
ature 1℃. Hold "+" or "-" button, 2s later, set temperature on remote controller will change quickly. After reaching to your required time, loosen the button. Temperature indicator on indoor unit will also change accordingly. (Temperature can’t be adjusted under auto mode)
● Under TIMER ON, TIMER OFF or Clock setting, you can press "+"or "-" button to
adjust time. (Refer to TIMER button for details)
Pressing this button can set fan speed circularly as: auto (AUTO), low( ),medium ( ), high( ).
Auto
Note:
● Under AUTO Speed,IDU fan motor will adjust the fan speed (high, medium or low
speed) according to ambient temperature.
● Fan speed under dry mode is low speed.
Press this button can select up&down swing. Swing angle can be selected in sequ­ence as below:
When selecting " " with remote controller, it’s auto swing. Horizontal louver of air conditioner will swing up&down automatically at the maximum angle. When selecting " 、 、 、
swing. Horizontal louver of air conditioner will stop at that position as shown by the icon to swing.
no display (horizontal louvers stops at current position)
button
Note:
For preventing cold wind, after starting up heating mode, indoor fan will blow fan afterdelaying 1-5min. (Details time is decided by indoor ambient temperature) Temperature setting range on remote controller: 16℃-30℃. Fan speed setting range: auto, low speed, medium speed and high speed.
9
CLOCK button
7
Introduction for buttons on remote controller
X-FAN button
8
6
After pressing this button under cooling or dry mode, remote controller displays the character of "X-FAN" and X-FAN function is started up. Press this button again to cancel X-FAN function. The character of "X-FAN" will disappear.
Note:
After starting up X-FAN function, when turning off the unit, indoor fan will continue
TIMER ON button
Note:
Time setting range: 0.5-24 hours.
Time interval between two operations can’t exceed 5s. Otherwise, remote
controller will exit the setting status automatically.
At ON status, press this button once can set TIMER OFF. The character of HOUR
TIMER
ON. After each pressing of "+" or "-" button, time will increase or decrease half an
hour. When holding "+" or "-" button, 2s later, the time will change quickly until to
Cancel TIMER OFF: Press "TIMER" button again under TIMER OFF status.
At OFF status, press this button once can set TIMER ON. Please refer to TIMER off for detailed operation. Cancel TIMER ON: Press "TIMER" button again under TIMER ON status.
Press this button, the clock can be set up, signal blink and display.Within 5 seconds, the value can be adjusted by pressing + or - button, if continuously press this button for 2 seconds above, in every 0.5 seconds, the value on ten place of Minute will be increased 1. During blinking, repress the Clock button, signal will be constantly displayed and it denotes the setting succeeded. After powered on, 12:00 is defaulted to display and signal will be displayed. If there is signal be displayed that denotes the current time value is Clock value, otherwise is Timer value.
10
Note:
● Outdoor ambient temperature display may can’t be selected for some models. When indoor unit receives " " signal, it displays indoor set temperature.
● Only for the model whose indoor unit has dual-8 display.
Time setting range: 0.5-24 hours.
Time interval between two operations can’t exceed 5s. Otherwise, remote controller will exit the setting status automatically.
Introduction for buttons on remote controller
TEMP button
TIMER OFF button
9
10
to
operate for a while at low speed to dry the residual water inside the indoor unit.
● When the unit operates under X-FAN mode, press "X-FAN" button can turn off X-FAN function. Indoor fan stops operation immediately.
Press this button can see indoor set temperature, indoor ambient temperature or outdoor ambient temperature on indoor unit’s display. Temperature is set circularly by remote controller as below:
no display
● When selecting " " by remote controller or no display, temperature indicator on indoor unit displays set temperature.
● When selecting " " by remote controller, temperature indicator on indoor unit displays indoor ambient temperature.
● When selecting " " by remote controller, temperature indicator on indoor unit displays outdoor ambient temperature.
Once press this key to enter into TIMER OFF setup, in which case the TIMER OFF icon will blink. The method of setting is the same as for TIMER ON.
11
Function introduction for combination buttons
Introduction for buttons on remote controller
TURBO button
SLEEP button
LIGHT button
11
12
13
When pressing this button under cooling or heating mode, air conditioner will enter into quick cooling or quick heating mode. The character of "TURBO" is displayed on remote controller. Press this button again to exit turbo function and the character of "TURBO" will be disappeared on remote controller.
Press this button under cooling, heating mode can start up sleep function. " " icon will be displayed on remote controller. Press this button again to cancel sleep function. " "icon on remote controller will be displayed.
Press this button can turn off the light for indoor unit’s display. " " icon on remote controller will disappear. Press this button again to turn on the light for indoor unit’s display. " " icon on remote controller will be displayed.
Child lock function
Switchover function for temperature display
Press "+" and "-" buttons simultaneously can turn on or turn off child lock function. When child lock function is started up, " " icon will be displayed on remote
controller won’t send signal.
After turning off the unit by remote controller, press "-" button and "MODE" button simultaneously to switch between ℃and °F .
12
Operation guide
Replacement of batteries in remote controller
1. Press the back side of remote controller marked
the cover of battery box along the arrow direction.
2. Replace two 7# (AAA 1.5V) dry batteries, and make sure the position of "+" polar and "-" polar are correct.
3. Reinstall the cover of battery box.
signal sender battery
Cover of battery box
remove
reinstall
Note:
● During operation, point the remote control signal sender at the receiving
window on indoor unit.
The distance between signal sender and receiving window should be no more than 8m, and there should be no obstacles between them.
or wireless telephone; remote controller should be close to indoor unit during operation.
● Replace new batteries of the same model when replacement is required.
● When you don’t use remote controller for a long time, please take out the
batteries.
● If the display on remote controller is fuzzy or there’s no display, please replace batteries.
1. After putting through the power, press " " button on remote controller to turn on the air conditioner.
2. Press " " button to select your required mode: AUTO, COOL, DRY, FAN, HEAT.
3. Press "+" or "-" button to set your required temperature. (Temperature can’t be adjusted under auto mode).
4. Press " " button to set your required fan speed: auto, low, medium and high speed.
5. Press " " and " " button to select fan blowing angle.
ON/OFF
MODE
FAN
13
Emergency operation
Clean and maintenance
air conditioner. When the air conditioner is turned on, it will operate under auto mode.
aux. button
panel
WARNING:
Use insulated object to press the auto button
If remote controller is lost or damaged, please use auxiliary button to turn on or turn off the air conditioner. The operation in details are as below:
WARNING
NOTICE:
Turn off the air conditioner and disconnect the power before cleaning the air conditioner to avoid electric shock.
■ Do not wash the air conditioner with water to avoid electric shock.
■ Do not use volatile liquid to clean the air conditioner.
Clean surface of indoor unit
When the surface of indoor unit is dirty, it is recommended to use a soft dry cloth or wet cloth to wipe it.
● Do not remove the panel when cleaning it.
14
Clean and maintenance
1
2
3
4
Open panel
Pull out the panel to a certain ● Use dust catcher or water to
the water (below 45℃) to clean it, and then put it in a shady and cool place to dry.
panel cover tightly.
operation environment, clean frequency can be increased.
WARNING
15
Clean and maintenance
1. Check whether air inlets and air outlets are blocked.
2. Check whether circuit break, plug and socket are in good condition.
4. Check whether mounting bracket for outdoor unit is damaged or corroded. If yes, please contact dealer.
5. Check whether drainage pipe is damaged.
1. Disconnect power supply.
3. Check whether mounting bracket for outdoor unit is damaged or corroded. If yes, please contact dealer.
Notice for recovery
1. Many packing materials are recyclable materials. Please dispose them in appropriate recycling unit.
2. If you want to dispose the air conditioner, please contact local dealer or consultant service center for the correct disposal method.
NOTICE: Checking before use-season
NOTICE: Checking after use-season
16
Malfunction analysis
General phenomenon analysis
Please check below items before asking for maintenance. If the malfunction still
can’t be eliminated, please contact local dealer or qualied professionals.
Phenomenon Check items Solution
Indoor unit can’t receive remote controller’s signal or remote controller has no action.
● Whether it's interfered severely
(such as static electricity, stable voltage)?
● Whether remote controller is
within the signal receiving range?
● Whether there are obstacles?
● Whether remote controller is
pointing at the receiving window?
● Is sensitivity of remote contro­ ller low; fuzzy display and no
display?
● No display when operating
remote controller?
● Fluorescent lamp in room?
● Pull out the plug. Reinsert
the plug after about 3min, and then turn on the unit again.
● Signal receiving range is 8m.
● Remove obstacles.
Select proper angle and point the remote controller at the re­ ceiving window on indoor unit.
● Check the batteries. If the
power of batteries is too low, please replace them.
● Take the remote controller
close to indoor unit.
● Turn off the uoresent lamp
and then try it again.
● Check whether remote cont-
roller appears to be damaged. If yes, replace it.
No air emitted from indoor unit
● Air inlet or air outlet of indoor
unit is blocked?
● Eliminate obstacles.
● Under heating mode, indoor
temperature is reached to set temperature?
● After reaching to set temper-
ature, indoor unit will stop bl­ owing out air.
● Heating mode is turned on just
now?
● In order to prevent blowing
out cold air, indoor unit will be started after delaying for sev­ eral minutes, which is a nor­ mal phenomenon.
17
Malfunction analysis
● Power failure?
● Is plug loose?
● Circuit break trips off or
fuse is burnt out?
● Wiring has malfunction?
● Unit has restarted immediately
after stopping operation?
● Whether the function setting
for remote controller is correct?
● Reset the function.
● Wait for 3min, and then turn
on the unit again.
● Ask professional to replace it.
● Ask professional to replace
circuit break or fuse.
● Reinsert the plug.
● Wait until power recovery.
Air condit-
ioner can’t operate
Mist is em­itted from indoor unit’s air outlet
● Indoor temperature and hum-
idity is high?
● Because indoor air is cooled rapidly. After a while, indoor
temperature and humidity will be decrease and mist will disappear.
Phenomenon
Check items Solution
Set temper­ature can’t be adjusted
● Unit is operating under auto
mode?
● Temperature can’t be adju-
sted under auto mode. Please switch the operation mode if you need to adjust temperature.
● Your required temperature
exceeds the set temperature range?
● Set temperature range:
16℃~30℃.
Cooling (heating) effect is not good.
● Voltage is too low?
● Wait until the voltage
resumes normal.
● Filter is dirty? ● Clean the lter.
● Set temperature is in proper
range?
● Adjust temperature to proper
range.
● Door and window are open? ● Close door and window.
18
Phenomenon Check items Solution
Odours are emitted
● Whether there’s odour source,
such as furniture and cigarette, etc.
● Eliminate the odour source.
● Clean the lter.
Air conditio-
ner operates abnormally
● Whether there’s interference,
such as thunder, wireless devices, etc.
● Disconnect power, put back
power, and then turn on the unit again.
Outdoor unit has vapor
● Heating mode is turned on?
● During defrosting under he-
ating mode, it may generate vapor, which is a normal phenomenon.
“Water
owing”
noise
● Air conditioner is turned on or
turned off just now?
● The noise is the sound of refrigerant owing inside
the unit, which is a normal phenomenon.
Cracking noise
● Air conditioner is turned on or
turned off just now?
● This is the sound of friction
caused by expansion and/or contraction of panel or other parts due to the change of temperature.
Malfunction analysis
19
Malfunction analysis
Error Code
● When air conditioner status is abnormal, temperature indictor on indoor unit will
ation of error code.
Indoor display
Error code
Above indicator diagram is only for reference. Please refer to actual product for the actual indicator and position.
■ When below phenomenon occurs, please turn off air conditioner and discon-
for service.
● Power cord is overheating or damaged.
● Theres abnormal sound during operation.
● Circuit break trips off frequently.
● Air conditioner gives off burning smell.
● Indoor unit is leaking.
■ If the air conditioner operates under abnormal conditions, it may cause
Note:
service.
Error code
Troubleshooting
Means defrosting status. It’s the normal phenomenon.
Heating indicator ON 10s OFF 0.5s
Defrosting or oil return mode
It is normal. The indicating lamp in heat mode will wink 0.5s and light 10s.
E5: overcurrent protection
Power indicator blinks and E5 is displayed
C5:Connector jumper malfunction
Check if the connector jumper contacts the properly. If replace the PCB, please take off the old for the new PCB.
F1:Indoor ambient temp. sensor malfunction
Check if indoor room temp. sensor is connected properly?
malfunction
F2:Evaporator temp.sensor
Check if indoor tube temp. sensor is connected properly?
Feedback terminal of PG motor hasn’t been connected firmly. The control end of PG motor hasn’t been connected firmly. Fan blade hasn’t been installed correctly and it can’t run smoothly. Motor hasn’t been installed correctly and tightly. Motor has been damaged. Control panel has been damaged.
H6:PC motor (indoor fan) can’t run
Control panel has been damaged.
U8:Malfunction of zero cross detection circuit for PG motor (indoor fan)
WARNING
20
Installation dimension diagram
Drainage pipe
At least 250cm
At least 15cm
At least 50cm
At least 50cm
At least
30cm
At least 300cm
At least 200cm
Space to the obstruction
Space to the
obstruction
Space to the
obstruction
Space to the ceiling
Space to the obstruction
Space to the obstruction
At least 30cm
At least 15cm
At least 15cm
Space to the wall
Space to the wall
Space to the wall
21
1. There should be no obstruction near air inlet and air outlet.
2. Select a location where the condensat­ ion water can be dispersed easily and won't affect other people.
3. Select a location which is convenient to connect the outdoor unit and near the power socket.
4. Select a location which is out of reach for children.
5.
The location should be able to withstand the weight of indoor unit and won't incr­ ease noise and vibration.
6.
The appliance must be installed 2.5m
above oor.
7. Don't install the indoor unit right above the electric appliance.
8. Please try your best to keep way from
uorescent lamp.
Tools for installation
Selection of installation location
1 Level meter 2 Screw driver 3 Impact drill 4 Drill head 5 Pipe expander 6 Torque wrench
7 Open-end wrench 8 Pipe cutter
9 Leakage detector
10 Vacuum pump 11 Pressure meter 12 Universal meter
13 Inner hexagon spanner 14 Measuring tape
Note:
● Please contact the local agent for installation.
● Don't use unqualied power cord.
Basic requirement
Outdoor unit
Indoor unit
Installing the unit in the following pla­ces maycause malfunction. If it is un­avoidable, please consult the local dealer:
1.The place with strong heat sources,
vapors, ammable or explosive gas
,
or volatile objects spread in the air.
2.The place with high-frequency devices (such as welding machine, medical equipment).
3.The place near coast area.
4.
The place with oil or fumes in the air.
5.The place with sulfureted gas.
6.Other places with special circums­ tances.
7.Do not use the unit in the immediate surroundings of a laundry a bath a shower or a swimming pool.
1. Select a location where the noise and outow air emitted by the outdoor unit
will not affect neighborhood.
2. The location should be well ventilated and dry, in which the outdoor unit won't be exposed directly to sunlight or strong wind.
3. The location should be able to withstand the weight of outdoor unit.
4. Make sure that the installation follows the requirement of installation dimension diagram.
5. Select a location which is out of reach for children and far away from animals or plants.If it is unavoidable, please add the fence for safety purpose.
22
Requirements for electric connection
Safety precaution
Grounding requirement
1. Must follow the electric safety regulations when installing the unit.
circuit break.
3. Make sure the power supply matches with the requirement of air conditioner. Unstable power supply or incorrect wiring or malfunction. Please install proper power supply cables before using the air conditioner.
4. Properly connect the live wire, neutral wire and grounding wire of power socket.
5. Be sure to cut off the power supply before proceeding any work related to electricity and safety.
7. If the supply cord is damaged, it must be replaced by the manufacturer, its
8. The temperature of refrigerant circuit will be high, please keep the interconnec­ tion cable away from the copper tube.
9. The appliance shall be installed in accordance with national wiring regulations.
10.Installation must be performed in accordance with the requirement of NEC and CEC by authorized personnel only
grounding with specialized grounding device by a professional. Please make sure it is always grounded effectively, otherwise it may cause electric shock.
2. The yellow-green wire in air conditioner is grounding wire, which can't be used for other purposes.
3. The grounding resistance should comply with national electric safety regulations.
4. The appliance must be positioned so that the plug is accessible.
5. An all-pole disconnection switch having a contact separation of at least 3mm in
6. Including an circuit break with suitable capacity, please note the following table. Air switch should be included magnet buckle and heating buckle function, it can protect the circuit-short and overload. (Caution: please do not use the fuse only for protect the circuit)
Air-conditioner
Circuit break capacity
09K 10A
18K 10A
12K 10A
23
Installation of indoor unit
Step one: choosing installation location
Step two: install wall-mounting frame
rm it with the client.
1. Hang the wall-mounting frame on the wall; adjust it in horizontal position with the
plastic expansion particles in the holes.
3. Fix the wall-mounting frame on the wall with tapping screws (ST4.2X25TA) and
.
1. Choose the position of piping hole according to the direction of outlet pipe. The position of piping hole should be a little lower than the wall-mounted frame, shown as below.
Step three: open piping hole
2. Open a piping hole with the diameter of Φ55 on the selected outlet pipe
position. In order to drain smoothly, slant the piping hole on the wall slightly downward to the outdoor side with the gradient of 5-10°.
18K0912K
Left
Wall
Φ55mm Φ55mm
Right
Mark in the middle of it
Level meter
Rear piping hole
Wall
Space
to the
wall
above
150mm
Space
to the
wall
above
150mm
Rear piping hole
mm150
Ф55mm
Ф55mm
mm0 5 1
Wall
Wall
Mark on the middle of it
Gradienter
Left
Right
(Rear piping hole)
(Rear piping hole)
Space to the wall
above
Space to the wall
above
24
1. Aim the pipe joint at the corresponding bellmouth.
2. Pretightening the union nut with hand.
3. Adjust the torque force by referring to the following sheet. Place the open-end wrench on the pipe joint and place the torque wrench on the union nut. Tighten the union nut with torque wrench.
2. When select leading out the pipe from left or right, please cut off the corresponding hole on the bottom case.
cut off the hole
left right
1. The pipe can be led out in the direction of right, rear right, left or rear left.
left
rear left
right
rear right
Step four: outlet pipe
Installation of indoor unit
Note:
● Pay attention to dust prevention and take relevant safety measures when
opening the hole.
The plastic expansion particles are not provided and should be bought
locally.
Indoor
5-10°
outdoor
Φ55
union nutpipe joint
pipe
25
4. Wrap the indoor pipe and joint of con­ nection pipe with insulating pipe, and then wrap it with tape.
Step six: install drain hose
Installation of indoor unit
torque wrench
open-end wrench
indoor pipe
pipe
union nut
Hex nut diameter Tightening torque (N.m)
Φ 6
Φ 9.52
Φ 12 Φ 16 Φ 19
30~40
45~55
60~65 70~75
15~20
insulating pipe
1. Connect the drain hose to the outlet pipe of indoor unit.
2. Bind the joint with tape.
outlet
pipe
drain hose
drain hose
tape
outlet pipe
drain hose
insulating pipe
Note:
● Add insulating pipe in the indoor
drain hose in order to prevent condensation.
● The plastic expansion particles are
not provided.
1. Open the panel, remove the screw on the wiring cover and then take down the cover.
wiring cover
screw
panel
Step seven: connect wire of indoor unit
26
N(1) 2 3
blue brownblack
yellow­green
Outdoor unit connection
2. Make the power connection wire go through the cable-cross hole at the back of indoor unit and then pull it out from the front side.
4. Put wiring cover back and then tighten the screw.
5. Close the panel.
Installation of indoor unit
Note:
All wires of indoor unit and outdoor unit should be connected by a professional.
for a new one. Avoid extending the wire by yourself.
installation.
● For the air conditioner without plug, an air switch must be installed in the line. The air switch should be all-pole parting and the contact parting distance should be more than 3mm.
3. Remove the wire clip; connect the power connection wire to the wiring terminal according to the color; tighten the screw and then fix the power connection wire with wire clip.
power connection wire
cable-cross hole
27
Installation of indoor unit
Step eight: bind up pipe
1. Bind up the connection pipe, power cord and drain hose with the band.
indoor unit
gas pipe
indoor and
outdoor power cord
liquid pipe
drain hose
band
2. Reserve a certain length of drain hose and power cord for installation when binding them. When binding to a certain degree, separate the indoor power and then separate the drain hose.
3. Bind them evenly.
4. The liquid pipe and gas pipe should be bound separately at the end.
Note:
● The power cord and control wire
can't be crossed or winding.
● The drain hose should be bound
at the bottom.
drain hose
band
connection pipe
indoor power cord
Step nine: hang the indoor unit
1. Put the bound pipes in the wall pipe and then make them pass through the wall hole.
2. Hang the indoor unit on the wall-mounting frame.
3. Stuff the gap between pipes and wall hole with sealing gum.
4. Fix the wall pipe.
5. Check if the indoor unit is installed rmly and closed to the wall.
Note:
● Do not bend the drain hose too excessively in order to prevent blocking.
indoor
outdoor
wall pipe
sealing gum
upper hook
lower hook of wall-mounting frame
28
Installation of outdoor unit
(select it according to the actual installation situation)
1. Select installation location according to the house structure.
2. Fix the support of outdoor unit on the selected location with expansion screws.
at least 3cm above the floor
Note:
installing the outdoor unit.
Make sure the support can withstand at least
four times of the unit weight.
The outdoor unit should be installed at least
joint.
● For the unit with cooling capacity of 2300W ~5000W, 6 expansion screws are needed; for the unit with cooling capacity of 6000W ~8000W, 8 expansion screws are needed; for the unit with cooling capacity of 10000W
~16000W, 10 expansion screws are needed.
Step two: install drain joint
gnitaeh dna gnilooc rof ylnO(
unit)
1. Connect the outdoor drain joint into the hole on the chassis, as shown in the picture below.
2. Connect the drain hose into the drain vent.
chassis
outdoor drain joint
Drain hose
drain vent
1. Place the outdoor unit on the support.
2. Fix the foot holes of outdoor unit with bolts.
foot holes
foot holes
29
Installation of outdoor unit
Step four: connect indoor and outdoor pipes
1. Remove the screw on the right han­ dle of outdoor unit and then remove the handle.
2. Remove the screw cap of valve and aim the pipe joint at the bellmouth of pipe.
3. Pretightening the union nut with hand.
4. Tighten the union nut with torque wrench by referring to the sheet below.
handle
screw
gas pipe
liquid pipe
liquid valve
gas valve
union nut
pipe joint
Hex nut diameter
Tightening torque
(N.m)
Φ 6
Φ 9.52
Φ 12 Φ 16 Φ 19
30~40
45~55 60~65 70~75
15~20
1. Remove the wire clip; connect the power connection wire and signal control wire (only for Heat pump type) to the wiring terminal according to the color;
Indoor unit connection
Indoor unit connection
N(1) 2 3
blue brownblack
yellow­green
1218K Cool only type and Heat
pump type(for some model
09
LN
2 3N(1)
N
L
POWER
blue
blue(white)
brown(black)
black brown
yellow­green
yellow- green (green)
0912K Cool only type and Heat pump type(for some model
30
Step six: neaten the pipes
1. The pipes should be placed along the wall, bent reasonably and hidden possibly. Min. semidiameter of bending the pipe is 10cm.
2. If the outdoor unit is higher than the wall
hole, you must set a U-shaped curve in the
pipe before pipe goes into the room, in order to prevent rain from getting into the room.
● The through-wal height of drain hose
shouldn't be higher than the outlet pipe hole of indoor unit.
● Slant the drain hose slightly dow-
nwards. The drain hose can't be
curved, raised and uctuant, etc.
● The water outlet can't be placed
in water in order to drain smoothly.
Installation of outdoor unit
U-shaped curve
wall
drain hose
the drain hose can't raise
upwards.
The drain hose can't be fluctuant
The drain hose can't be fluctuant
The water outlet can't be fluctuant
The water outlet can't be placed in water
Note:
2. Fix the power connection wire and signal control wire with wire clip (only for cooling and heating unit).
Note:
● After tighten the screw, pull the power cord slightly to check if it is rm.
● Never cut the power connection wire to prolong or shorten the distance.
31
Vacuum pumping
Leakage detection
1. Remove the valve caps on the liquid valve and gas valve and the nut of refri­ gerant charging vent.
2. Connect the charging hose
of piezometer to the refri-
gerant charging vent of gas valve and then connect the other charging hose to the vacuum pump.
3. Open the piezometer com-
pletely and operate for 10-15min to check if the
pressure of piezometer re-
mains in -0.1MPa.
4. Close the vacuum pump and maintain this status for 1-2min to check if the pres-
sure of piezometer remains
in -0.1MPa. If the pressure decreases, there may be leakage.
5. Remove the piezometer, open the valve core of liquid valve and gas valve
completely with inner hexagon spanner.
6. Tighten the screw caps of valves and refrigerant charging vent.
7. Reinstall the handle.
Use vacuum pump
liquid valve
gas valve
refrigerant charging vent
nut of refrigerant charging vent
vacuum pump
piezometer
valve cap
Lo Hi
inner hexagon spanner
open
close
1. With leakage detector: Check if there is leakage with leakage detector.
2. With soap water: If leakage detector is not available, please use soap water for leakage detection.
Apply soap water at the suspected position and keep the soap water for more
than 3min. If there are air bubbles coming out of this position, there's a leakage.
32
Check after installation
Test operation
● Check according to the following requirement after nishing installation.
Items to be checked Possible malfunction
Has the unit been installed rmly? The unit may drop, shake or emit noise. Have you done the refrigerant leakage
test?
It may cause insufcient cooling
(heating) capacity.
Is heat insulation of pipeline sufcient?
It may cause condensation and water dripping.
Is water drained well?
It may cause condensation and water dripping.
Is the voltage of power supply accord­ing to the voltage marked on the nameplate?
It may cause malfunction or damaging the parts.
Is electric wiring and pipeline installed correctly?
It may cause malfunction or damaging
the parts. Is the unit grounded securely? It may cause electric leakage. Does the power cord follow the speci-
cation?
It may cause malfunction or damaging
the parts. Is there any obstruction in the air inlet
and outlet?
It may cause insufcient cooling
(heating) capacity. The dust and sundries caused during
installation are removed?
It may cause malfunction or damaging
the parts. The gas valve and liquid valve of
connection pipe are open completely?
It may cause insufcient cooling
(heating) capacity.
1. Preparation of test operation
● The client approves the air conditioner.
● Specify the important notes for air conditioner to the client.
2. Method of test operation
● Put through the power, press ON/OFF button on the remote controller to start
operation.
● Press MODE button to select AUTO, COOL, DRY, FAN and HEAT to check
whether the operation is normal or not.
● If the ambient temperature is lower than 16℃, the air conditioner can’t
start cooling.
33
1. Standard length of connection pipe
● 5m, 7.5m, 8m.
4. The additional refrigerant oil and refrigerant charging required after prolonging connection pipe
After the length of connection pipe is prolonged for 10m at the basis of standard length, you should add 5ml of refrigerant oil for each additional 5m
of connection pipe.
The calculation method of additional refrigerant charging amount (on the basis of liquid pipe):
Basing on the length of standard pipe, add refrigerant according to the requirement as shown in the table. The additional refrigerant charging amount per meter is different according to the diameter of liquid pipe. See the
following sheet.
Additional refrigerant charging amount = prolonged length of liquid pipe × additional refrigerant charging amount per meter
Cooling
capacity
Cooling
capacity
5000Btu/h
(1465W)
24000Btu/h
(7032W)
7000Btu/h
(2051W)
28000Btu/h
(8204W)
9000Btu/h
(2637W)
36000Btu/h
(10548W)
12000Btu/h
(3516W)
42000Btu/h
(12306W)
18000Btu/h
(5274W)
48000Btu/h
(14064W)
Max height difference
Max height difference
Max length of connec­tion pipe
Max length of connec­tion pipe
15 255 10
15 305 10
15 305 20
20 3010 20
25 3010 20
2.Min. length of connection pipe is 3m.
3.Max. length of connection pipe and max. high difference.
Configuration of connection pipe
34
Additional refrigerant charging amount for R22, R407C, R410A and R134a
Diameter of connection pipe
Liquid pipe(mm) Gas pipe(mm)
Φ6
Φ6 or Φ9.52
Φ12
Φ16
Φ19
Φ22.2
Φ9.52 or Φ12
Φ16 or Φ19
Φ19 or Φ22.2
Φ25.4 or Φ31.8
_
_
Cooling only(g/m) Cooling and heating(g/m)
15
15
30
60
250 250
350
350
120
120
50
20
Outdoor unit throttle
Conguration of connection pipe
35
Pipe expanding method
Note:
Improper pipe expanding is the main cause of refrigerant leakage. Please expand the pipe according to the following steps:
A: Cut the pipe
● Conrm the pipe length according to
the distance of indoor unit and outdoor unit.
● Cut the required pipe with pipe cutter.
pipe
pipe cutter
leaning uneven burr
B: Remove the burrs
● Remove the burrs with shaper and
prevent the burrs from getting into the pipe.
downwards
pipe
shaper
C: Put on suitable insulating pipe D: Put on the union nut
● Remove the union nut on the indoor
connection pipe and outdoor valve; install the union nut on the pipe.
union pipe
pipe
E: Expand the port
● Expand the port with expander.
Note:
● "A" is different according to the
diameter, please refer to the sheet below:
expander
hard mold
pipe
F: Inspection
● Check the quality of expanding port.
If there is any blemish, expand the port again according to the steps above.
the length is equal
improper expanding
leaning
damaged
surface
crack uneven
thickness
smooth surface
Outer diameter
(mm)
A(mm)
Max Min
Φ6-6.35(1/4")
Φ9.52(3/8")
Φ12-12.7(1/2") Φ15.8-16(5/8")
1.3 0.7
1.6 1.0
1.8 1.0
2.4 2.2
36
ELNUR S.A.
Travesía de Villa Esther, 11
28110 Algete - Madrid
Tfno. de Atención al Cliente:
+34 91 628 1440
www.elnur.es
www.elnur-global.com
www.elnur.co.uk
As a part of the policy of continuous product improvement Elnur s.a. reserves the right to alter specifications without notice.
Loading...