G4S Technology S840 User Manual

Installation and User Instructions for S840 Readers
The S840 is a contactless smart-card reader with keypad, which uses p
communications
cards.
Fit the Weatherproofing Kit
1
When mounting outside, the two-part gasket kit must be fitted:
a) Remove the backplate from the reader by
releasing the two securing screws.
b) Remove the cutouts and backing paper
from the two gaskets, then stick them to the backplate as shown.
The optional heater kit maintains the reader at the correct temperature when mounted outside. With the backplate off, remove the backing paper from the two elements, then stick them to the inner sides of the reader. The heaters must be connected to a 24V AC supply (min 25VA).
2
Mount the Backplate
20mA current loop seudo-random
. The S840 is able to read HID format
®
Outer gasket
Backplate
Inner gasket
Backplate securing screws
With the backplate off (see above), mount the backplate adjacent to the opening edge of the door and at a convenient height. Feed the required cables through the backplate:
The cable from the controller.
!
The cable from the heater, if used (must
!
be a separate cable). A cable from a Remote Interface Module
!
(RIM), if used. A RIM can reduce cable lengths to door furniture.
3
Reader Links
Ensure no jumper is fitted across LK2 (TEST). If a jumper is provided, park it across one pin only. LK4 (AUDIO KB FB) - set to 1 for sound on and 0 for sound off. LK1 (LED BR) - set to H position.
You should find that the backplate has holes for connection to most standard electrical backboxes.
4
Reader Connections
a
Reader
The I/O terminal is for connection to a RIM (see
+12V
the RIM Instructions).
RX-
On completion, re-secure
RX+
the reader to the backplate.
I/0
TX-
TX+ Do not use
0V
b
12V
Controller connections (20mA current loop)
Connect shield at controller end only (attach to case).
5
Present the card face-on to the reader until you hear "bleep". Cards can be presented in rapid succession; there is no need to wait for the green or red LED to extinguish efore presenting another.
If the reader has been enabled for user-code mode at the controller, you can gain access by pressing the # key, entering your card number, then pressing the * key.
0V
TX-
TX+
RX-
RX+
Using the Reader
About the Reader LEDs
Green (access granted) LED
Red (access denied) LED
Flashing amber (PIN) LED
Twisted pairs (use Belden 9503 cable)
When this LED is lit, the lock is released and you may open the door.
This is lit if you do not have access rights to gain entry, or if the reader could not read your card (in this case, move the card away,thenpresentitagain).
If the amber LED flashes, enter your PIN. If you make a mistake, the red LEDis lit for a moment, then theflashing amber prompts you to try again.
Alarm LED
These auxiliary LED indicators can be configured to operate in conjunction with conditional commands.
Switch LED
9600-0347. Installation and User Instructions for S840 Readers,
Issue 1.0x2 7th January 2004. AMAG Technology Ltd, 2004. FCC Notice: This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Any unauthorized modification to this device may void the authority of the user to operate it.
All trademarks acknowledged. HID is a registered trademark of HID Corporation.
©
}
Specifications
Input voltage: 9-14Vdc. Input current (excl. heater): 110mA @ nom. 12Vdc. Operating temperature: -13 to 158 F (-25 to 70 C) without heater. Operating humidity: 15 to 90%, non-condensing. Maximum read range: 6" (150mm). Approvals: EN50133, R&TTE, IP656.
°°
Loading...