FXI Power Play Manual rev.24 01/25/13
TABLE OF CONTENTS
Important Safeguards..................................................................................................................................4
Shear and friction reduction....................................................................................................................6
Indications for use.........................................................................................................................................7
System Specifi cations.....................................................................................................................................11
Patient Comfort Controls and Monitoring..............................................................................................,.........21
Other Features..................................................................................................................................................22
Suspend/Disable Low Air Loss Therapy....................................................................................................22
Power failure................................................................................................................................................22
Storage and Care..............................................................................................................................................24
Call for Assistance...........................................................................................................................................24
FXI Power Play Manual rev.24 01/25/13
IMPORTANT SAFEGUARDS
Read ALL Instructions BEFORE Using This Product
IMPORTANT NOTICE:
The equipment has to be installed and
operated in the manner for which it was
4
FXI Power Play User Manual
intended. Facility staff/user is responsible
for reading and understanding the product
user manual and contacting FXI if anything
in this manual is unclear. FXI will not be held
responsible for any injuries resulting from
failure to comply with the instructions and
precautions in this manual.
WARNING:
The FXI specialty support surfaces are designed to fi t
on a standard bed frame. The risk of entrapment can
arise when the equipment is placed on bed frames
that leave gaps of even a few inches between the
mattress and the headboard, footboard, and bed or
side rails. The equipment is NOT to be used when
such gaps are present.
Facility staff/user is responsible for ensuring that all
mattresses properly fi t the bed frames. FXI is not
responsible for the placement of its equipment on
bed frames that leave gaps between the mattress
and the headboard, footboard or bed or side rails
which present a risk of harm to patients.
WARNING: (See Safety Information in “Nursing Procedures” Section)
The safe use of the equipment is maximized when used in conjunction with bed rails and there may be
an increased risk of falls when such bed rails are not present. Serious injury or death can result from the
use (potential entrapment) or non-use (potential patient falls) of side rails or other restraints. Local policies
regarding the use of side rails should be taken into account. Whether and how to use side rails is a decision
that should be based on each patient’s individual needs and should be made by the physician, caregivers and
responsible parties.
When using the mattress system always ensure that the patient is positioned properly within the confi nes of
the bed. Do not let any extremities protrude over the side or between the bed rails when the mattress is being
used.
FXI Power Play Manual rev.24 01/25/13
DANGER EXPLOSION HAZARD:
DO NOT USE IN THE PRESENCE OF FLAMMABLE
ANAESTHETICS. DO NOT USE IN THE PRESENCE
OF SMOKING MATERIALS OR OPEN FLAME. AIR
FLOWING THROUGH THE AIR MATTRESS WILL
SUPPORT COMBUSTION.
WARNING:
A possible fi re hazard exists. This product is suitable for
use with oxygen administering equipment of the nasal,
mask, or half bed-length, tent-type only. To prevent
personal injury or equipment damage, ensure that the
oxygen tent does not extend below the mattress
DANGER:
To reduce the risk of shock, perform the following
instructions. Failure to do so could result in personal
injury or equipment damage.
Immediately after using the Symbioso Power Play, 1)
unplug it from its power source.
Do not place or store the product where it can fall or 2)
be pulled into a tub or sink.
Do not place or drop the product into water or other 3)
liquid.
Do not remove the enclosure of the Surface Power 4)
Unit. Refer servicing to Linet.
the mattress input grill.
Never drop or insert any object into any grill 6)
opening
When storing the Surface Power Unit 7)
separately from the mattress take care not to
spill food or liquids onto the Surface Power
Unit.
The optional Surface Power Unit is designed 8)
to be used as part of the FXI Power Play
support surface. Do not operate the Surface
Power Unit outside the mattress.
Do not use the product outdoors, or where 9)
aerosol-spray products are used.
Plug this product only into a properly 10)
grounded outlet. Refer to “Grounding
Instructions”.
Be sure nothing is placed on the power cord 11)
and ensure it is not located where it can be
stepped on or tripped over.
Do not attempt to service the Surface Power 12)
Unit or Pendant. Please call Linet for any
service requests.
SAVE THESE INSTRUCTIONS FOR
FUTURE REFERENCE
5
5
FXI Power Play User Manual
WARNING:
To reduce the risk of burns, shock, fi re, or personal
injury, perform the following instructions. Failure to do so
could result in personal injury or equipment damage.
Use this product only for its intended use as 1)
described in this manual. Only use attachments
and/or accessories that are recommended by the
manufacturer.
The AC Power Cord acts as the main disconnect for 2)
this device. Make sure to maintain adequate access
to the AC power connection.
If this product has a damaged power cord or plug, 3)
is not working properly, has been dropped or
damaged, or has been dropped into water, do not
operate it. For examination and repair, return the
product to FXI.
Keep the Surface Power Unit , Pendant and power 4)
cord away from heated surfaces, i.e. space heaters.
For best performance void blocking the air openings 5)
in the mattress Surface Power Unit output grill or on
FXI Power Play Manual rev.24 01/25/13
INTRODUCTION
The FXI Power Play, provided by FXI is a
unique therapy system that provides pressure
relief and, with the optionally installed Surface
Power Unit/Pendant, Low Air Loss moisture
control therapy.
Moisture control through Low air Loss therapy
has been demonstrated to reduce the risk of
and aid in the treatment of pressure ulcers (bed
6
sores caused by loss of skin blood fl ow).
MOISTURE CONTROL
Patients are at risk for skin maceration if excess
moisture is permitted to accumulate beneath the patient.
This may be due to perspiration, incontinence or wound
drainage. On the FXI Power Play moisture is controlled
via the specially treated, semi-permeable protective
laminate cover. Moisture control can be further enhanced
through the use of the optional “Surface Power Unit” to
provide Low Air Loss therapy capability.
FXI Power Play User Manual
The FXI Power Play mattress replacement
system is suitable for the care and prevention
of all stages of pressure ulcers and for patients
who have been assessed to be at risk from the
complications of immobility. The FXI Power Play
is quiet and simple enough for single caregiver
installation. The user-friendly controls allow for
easy adjustment of patient comfort.
Additionally, low friction and shear materials
together with average interface pressures well
below capillary closing pressure means that the
FXI Power Play mattress system meets the
comfort and clinical requirements of patients up
to 500 pounds.
We have ensured that the FXI Power Play
addresses the three key areas in the treatment
of compromised skin:
Pressure relief •
Moisture control •
Reduction in shearing forces•
SHEAR AND FRICTION REDUCTION
Shearing occurs when the skin is stationary in relation
to the support surface, while the underlying tissues and
vessels are stretched and damaged. When a patient’s
skin rubs against another surface, the result is friction.
The top surface of the FXI Power Play therapy cover is
constructed from a very smooth fabric with low friction
and shear properties to protect the patient’s skin from
these damaging forces.
PRESSURE RELIEF
FXI Power Play is a convertible dynamic
pressure relieving mattress system that has two
modes of operation:
Non-powered•
Powered Low Air Loss•
Powered mode requires the installation of
the FXI Power Play Surface Power Unit and
Pendant. The non-powered mode requires only
that a Surface Power Unit not be turned on or
not installed.
FXI Power Play Manual rev.24 01/25/13
INDICATIONS FOR USE
PRESSURE RELIEF
Patients with these conditions could be candidates for
The selection of a pressure-relieving surface needs to
be based on each individual patient’s clinical condition
or diagnosis and co-morbidities. The FXI Power Play
mattress system provides pressure relief well below
capillary closing levels and allows for adequate perfusion
to promote healing.
PAIN MANAGEMENT
Patients with these conditions could be
candidates for the FXI Power Play mattress
system:
AIDS•
Arthritis•
Oncology•
The FXI Power Play mattress system provides
uniform distribution of weight over a wide
surface area, which relieves pressure against
bony prominences and provides a soft,
gentle therapy surface to lie on. For patients
experiencing severe pain and discomfort due to
pressure and/or positioning limitations, consider
the FXI Power Play mattress system as an
adjunct to pain management interventions.
7
7
FXI Power Play User Manual
FXI Power Play Manual rev.24 01/25/13
FEATURES
The FXI Power Play Surface Power Unit is comprised of two components, designed to work with the FXI Power
Play mattress.
Surface Power Unit – This fi ts into the mattress and is connected to a wall outlet through a external low voltage
power supply.
Pendant control - This wirelessly connects to the in mattress Surface Power Unit and is used to control the Low
Air Loss therapy level.
8
FXI Power Play User Manual
Surface Power Unit
Pendant
FXI Power Play Manual rev.24 01/25/13