Future Automation LA User Manual

Page 1
LA - Lifting Arm
Instructions
Sheet 1 of 8
ISSUE: 001
www.futureautomation.co.uk
FUTURE
AUTOMATION
Page 2
LA - Lifting Arm
Instructions
www.futureautomation.co.uk
Your Pack Should Contain
Sheet 2 of 8
ISSUE: 001
1 No. IR Remote
1 No. Remote Control
1 No. Silver Control Box and Infrared Receiver
1 No. Black Power Supply
1 No. RJ45 Lead to test contact closure
1 No. Group A bolt pack to secure screen
WARNING
It is the responsiblity of
the installer to warn all
potential end users of
the dangers of interfering
with mechanisms during
operation
IMPORTANT
Mechanisms which lift or move weights need
to be checked on a
yearly basis for any
damage which may
result in an accident
FUTURE
AUTOMATION
Page 3
LA - Lifting Arm
Instructions
Stage 1
Controlling the Mechanism
Sheet 3 of 8
ISSUE: 001
www.futureautomation.co.uk
Uprights
Actuator
Connect up the lead from the black power supply to the actuator. Plug in the silver control box and use the remote control to operate the lift.
It will just use OUT, IN and STOP.
FUTURE
AUTOMATION
Page 4
LA - Lifting Arm
Instructions
www.futureautomation.co.uk
Stage 2
Fitting the Screen
Place the insert into the mechanism.
Put the mechanism in the box but don't secure at this stage.
The screen can be secured in place. Rest it carefully on the upper arm and bolt in plate. Use spacers if the screen has recesses in the back.
Sheet 4 of 8
ISSUE: 001
Upper Arm
Insert
FUTURE
AUTOMATION
Page 5
LA - Lifting Arm
Instructions
Stage 3
Fitting Lid and Switches
The lid can be fitted using screws and washers through the 10 holes in the Lid Mounts.
See the technical sheet showing the cabinet dimensions, to determine the gap above the screen.
The four safety switches can be screwed to the side of the box. They line up with the cut outs in the Top Panel. Set up so that the safety edge can move down 3 to 5mm and operate the switches. When plugged into the control box they will stop the mechanism.
Sheet 5 of 8
ISSUE: 001
www.futureautomation.co.uk
Lid Mounts
3
A
A
Detail B
TOP
Safety Edge
B
Safety Switches
Section AA
Top Panel
FUTURE
AUTOMATION
Page 6
LA - Lifting Arm
Instructions
www.futureautomation.co.uk
Stage 4
Setting Up
When you take the machanism down for the first time with the lid on, be prepared to press if it goes down to far. It should ideally stop short of hitting the safety edge by about 2mm.
Adjusting the length of the strut bar will adjust how horizontal the lid will be in the down position. Adjust this first.
To change the height of the lid in relationship to the box, adjust the two link bars equally, or lift the mechanism up on shims. In the down position line up the lid with the box by moving the mechanism. Then fix in place.
stop
Sheet 6 of 8
ISSUE: 001
Top Trim
Cables come out here.
Strut Bolt
Screen cables are run through the arm. Remove the cover plates to gain access through the joint.
Finally fit the Top Trim using magnetic catches or similar.
2 to 3mm
C
Detail C
Screen Cables go in here on both sides
FUTURE
Link Bars
AUTOMATION
Page 7
LA - Lifting Arm
Control Details
Contact Closure
Use an RJ45 connector in the CC1 socket on the control box to operate via contact closure.
Sheet 7 of 8
ISSUE: 001
www.futureautomation.co.uk
PIN
1
2
3
4
5
6
7
8
568
A
W/G
G
W/O
BL
W/BL
O
W/BR
BR
568
B
W/O
O
W/G
BL
W/BL
G
W/BR
BR
DESCRIPTION
12V SUPPLY CURRENT LIMITED
12V TRIGGER
GROUND
DEVICE TOGGLE
DEVICE LATCH
DEVICE STOP
DEVICE IN
DEVICE OUT
ACTION
When 12V is attached, will go OUT. When 12V is removed, will go in.
Momentary short to ground to toggle from in to out and out to in. CC5
Short to ground will make device go out. Release short to go in. CC4
Momentary short to ground, stops device in current position. CC3
Momentary short to ground will make device go in. CC2
Momentary short to ground will make device go out. CC1
FUTURE
AUTOMATION
Page 8
LA - Lifting Arm
Control Details
RS232
Use an RJ11 connector in the socket marked RS232 on the control box to operate using RS232.
DETAILS
Band rate: 9600 Stop bit: 1 Parity: None Databits: 8
PROTOCOL
ASCI fa up, = Device up fa down, = Device down fa stop, = Device stop
Sheet 8 of 8
ISSUE: 001
www.futureautomation.co.uk
6
1
PIN 1 - IN PIN 6 - OUT PIN 2+3 - GROUND
PIN 2 - IN PIN 3 - OUT PIN 5 - GROUND
FUTURE
AUTOMATION
Loading...