Future Automation EAD User Manual

Electric Advance & Drop
Instruction Sheet
Sheet 1 of 8
ISSUE: 003
www.futureautomation.co.uk
1 IR Remote Control
FUNCTION
A remote controlled mechanism that will advance and drop a
screen while keeping
it parallel to the wall.
SUITABILITY
SPECIFYING
The wall the mechanism is to be fixed to must be
completely vertical.
WARNING
It is the responsiblity of
the installer to warn all
potential end users of
the dangers of interfering
with mechanisms during
operation
IMPORTANT
Mechanisms which lift or move weights need
to be checked on a
yearly basis for any
damage which may
result in an accident
FUTURE
CONTROL
Supplied with basic infrared
remote. Can be learnt
by many learning remotes.
Also has switch control so can be operated by relays, switches, Crestron/AMX or
Lutron systems.
AUTOMATION
Electric Advance & Drop
Instruction Sheet
Sheet 2 of 8
ISSUE: 003
www.futureautomation.co.uk
Fixing to Wall
Always use appropriate
fixing types.
Fitting The Mechanism To The Wall
The EAD must be completely vertical. Make sure with the use of a spirit level that the wall behind is vertical. If it is not, you will have to use washers / spacers behind the wall plates in order to make the mechanism completely vertical.
A
Suitability of wall fixings will
depend on the type of
wall the product is to
be fixed to.
If unsure, please seek instruction from your
supplying dealer.
FUTURE
DETAIL A
AUTOMATION
Electric Advance & Drop
Instruction Sheet
Checking The Mechanism
Sheet 3 of 8
ISSUE: 003
www.futureautomation.co.uk
Movement
Once fixed to the wall, make
sure the mechanism moves
freely and with ease.
Be sure that the mechanism
cannot sit back against the
wall by itself.
The mechanism operates
by unwinding a long strap
system within the casing.
If the mechnism is leaning back a lot, the mechansim
may fail to release from
the wall properly.
Make sure the mechanism
CANNOT stay in this position
without motor power or assistance.
FUTURE
AUTOMATION
Electric Advance & Drop
Instructions Sheet
Adjusting Mechanism Limits
B
DO NOT REMOVE THIS SCREW
Sheet 4 of 8
ISSUE: 003
www.futureautomation.co.uk
X4 COVER BOLTS
IN SWITCH
OUT SWITCH
DETAIL B
The EAD comes set to its maximum drop. Do not try to adjust it past it's factory setting.
When the buttons are clicked out they are set. To adjust the positions push the buttons so they are clicked in, use the remote to get mechanism in the new positions. Press stop on the remote in the desired position and set by pressing the corresponding motor switch so it clicks out. The new position is now set.
FUTURE
AUTOMATION
Electric Advance & Drop
Instruction
Sheet
Sheet 5 of 8
ISSUE: 003
www.futureautomation.co.uk
Electrical Connections
The EAD the AC2 connection block.
mechanism must be connected to
Remove this screw to release the lid
Connect the Infrared Sensor here
A
DETAIL A
Connect the IEC Power Lead Here
It is VERY important that when all of the
connector blocks are connected in the
FUTURE
electrical connections are made, the
way shown above, with all the wires
coming directly out the top of the
connector blocks.
AUTOMATION
Instruction
Electric Advance & Drop
Sheet
Contact Closure
Use an RJ45 connector in the CC1 socket on the control box to operate via contact closure.
Sheet 6 of 8
ISSUE: 003
www.futureautomation.co.uk
1
pins
8
There are a number of LEDs which will light up when the corresponding contact closure connections are shorted together.
A red LED will light up when the emergency stop link is removed.
B
PIN
1
2
3
4
5
6
7
8
568
A
W/G
G
W/O
BL
W/BL
O
W/BR
BR
568
B
W/O
O
W/G
BL
W/BL
G
W/BR
BR
DESCRIPTION
12V SUPPLY CURRENT LIMITED
12V LATCH
GROUND
DEVICE IN LATCHED
DEVICE STOP
DEVICE OUT
DEVICE IN
ACTION
When 12V is attached, device will go OUT. When 12V is removed, device will go IN.
When shorted to ground, device will go OUT. When short removed, device will go IN. CC4
When shorted to ground, stops device in current position. CC3
Momentary short to ground will make device go OUT. CC2
Momentary short to ground will make device go IN. CC1
DETAIL B
FUTURE
AUTOMATION
Instruction
Electric Advance & Drop
Sheet
RS232
Use an RJ11 connector in the socket marked RS232 on the control box to operate using RS232.
DETAILS
Band rate: 9600 Stop bit: 1 Parity: None Databits: 8
PROTOCOL
ASCI fa_in = Device IN fa_out = Device OUT fa_stop = Device STOP
Sheet 7 of 8
ISSUE: 003
www.futureautomation.co.uk
= Carriage Return
PIN 1: IN
PIN 6: OUT
PIN 3&4: GROUND
6
7
1
8
2
3
9
4
5
FUTURE
PIN 2: IN
PIN 3: OUT
PIN 5: GROUND
AUTOMATION
Instruction
Electric Advance & Drop
Sheet
Operation Details
Sheet 8 of 8
ISSUE: 003
www.futureautomation.co.uk
Contact Closure LEDs
To show the contact closure operation is working correctly. LEDs are on when connections are shorted together.
EMERGENCY STOP
This connection will stop all functions of the mechanism once broken / removed. Red LED will also be on.
AC2
Gives an output of 240V(or 110V) to control the Electric Tilt motor.
Outputs stay live for 60 seconds after the OUT or IN functions are selected.
FUTURE
AUTOMATION