Fusion by GLP Exo Wash 30 Moving Head User Manual [EN]

User Manual
Software version V1.0.00
Fusion EXO Wash 30
GLP® Fusion EXO Wash User Manual – Revision B
© 2019 German Light Products GmbH. All rights reserved.
The marks ‘GLP’ and ‘German Light Products’ are trademarks registered as the property of German Light Products GmbH in Germany, in the United States of America and in other countries.
The information contained in this document is subject to change without notice. German Light Products GmbH and all affiliated companies disclaim liability for any injury, damage, direct or indirect loss, consequential or economic loss or any other loss occasioned by the use of, inability to use or reliance on the information contained in this document.
Manufacturer’s head office: German Light Products GmbH (GLP), Industriestrasse 2, 76307 Karlsbad, Germany Tel (Germany): +49 7248 92719 - 0
Service & Support EMEA: GLP, Industriestrasse 2, 76307 Karlsbad, Germany Tel. (Germany): +49 7248 9271955 Email: support@glp.de www.glp.de
Service & Support USA: GLP USA, 1145 Arroyo St., Ste. A, 91340 San Fernando, California Tel (USA): +1 818 767 8899 Support (US): info@germanlightproducts.com www.germanlightproducts.com
Table of Contents
1. Safety .......................................................................................................... 5
Key to symbols ...................................................................................... 5
General safety information ................................................................. 5
Electrical safety .................................................................................... 6
Fire safety and protection from burns ................................................ 7
Eye safety .............................................................................................. 8
Strobe safety ......................................................................................... 8
Installation safety and protection from personal injury ................... 9
2. Avoiding damage to the fixture ............................................................ 10
General precautions .......................................................................... 10
Avoiding damage from light sources and heat ............................. 10
IP rating ................................................................................................ 11
Avoiding damage from water and humidity .................................. 11
Avoiding damage from dust and airborne particles ..................... 12
Transportation and storage ............................................................... 12
GLP Service and Support ................................................................... 12
3. EXO Wash 30 overview ........................................................................... 13
4. Installation ................................................................................................. 15
Permitted mounting options ............................................................. 15
Securing fixtures with a safety cable ............................................... 15
Installing on a rigging truss or similar structure ................................. 16
Standing on a horizontal surface ..................................................... 17
5. AC mains power ...................................................................................... 18
Included items .................................................................................... 18
Connecting to power ........................................................................ 18
Installing power connectors .............................................................. 19
Connecting multiple fixtures to power in a chain .......................... 19
6. Connecting to DMX data ....................................................................... 20
7. Starting and stopping operation ........................................................... 21
8. Features .................................................................................................... 22
Position ................................................................................................. 22
Color .................................................................................................... 22
.............................................................................................................. 22
Dimming .............................................................................................. 23
Strobe / shutter ................................................................................... 23
Zoom .................................................................................................... 23
Behavior when the fixture is not receiving a DMX signal ............... 23
9. Control menus and onboard display .................................................... 24
Display options .................................................................................... 25
Display Locking ................................................................................... 25
Manual Control ................................................................................... 25
LED PWM frequency ........................................................................... 25
Fan control .......................................................................................... 25
Fixture information .............................................................................. 25
Pan disable / Tilt disable .................................................................... 26
Preset settings and factory defaults ................................................. 26
10. Control menu layout ............................................................................... 27
Service Advanced menu .................................................................. 29
11. DMX control modes overview ................................................................ 30
12. DMX control channel layout tables ....................................................... 33
DMX Mode 1: Compact .................................................................... 33
DMX Mode 2: Standard ..................................................................... 35
DMX Mode 3: Extended .................................................................... 39
13. Service ...................................................................................................... 48
Cleaning .............................................................................................. 48
GLP Service and Support ................................................................... 48
14. Technical specifications ......................................................................... 49
Optics ................................................................................................... 49
Control ................................................................................................. 49
Installation ........................................................................................... 49
Electrical .............................................................................................. 49
Connections ........................................................................................ 49
Construction ........................................................................................ 49
Thermal ................................................................................................ 49
Included items .................................................................................... 50
Dimensions and weight ..................................................................... 50
15. Dimensions ................................................................................................ 51
German Light Products® Safety
Warning! Safety hazard. Risk of severe injury or death.
Warning! Hazardous voltage. Risk of lethal or severe electric shock.
Warning! See user manual for important safety information.
Warning! Fire hazard.
Warning! Risk of eye injury.
1. Safety
Key to symbols
The following symbols are used in the Fusion EXO Wash 30 lighting fixture’s user documentation:
General safety information
Read this manual carefully before installing, using or servicing the Fusion EXO Wash 30 lighting fixture.
If you have any doubts or questions about how to use the fixture safely, contact your GLP® supplier for assistance. Your GLP supplier will be happy to help.
The user documentation for GLP Fusion EXO Wash 30 lighting fixtures consists of:
This document, the EXO Wash 30 User Manual, supplied with the fixture and available for download from www.glp.de. The User Manual contains important safety information and installation instructions that the installer and user must read.
The EXO Wash 30 DMX Channel Index, available for download from www.glp.de. The Channel Index is a separate guide to the DMX control channel layout and DMX commands available.
All documents are available for download from www.glp.de. The Fusion EXO Wash 30 is intended for use by experienced professionals with the
knowledge and skills to set up, operate, and maintain high-powered, remotely controlled lighting equipment safely and efficiently. These operations require expertise that may not be provided in this Manual or in the User Manual.
Respect all warnings and directions given in the fixture’s user documentation and on the fixture. Read the user documentation and familiarize yourself with the safety precautions it contains before installing or using the fixture. GLP and affiliated
EXO Wash 30 User Manual Rev. B 5
www.glp.de Safety
companies will take no responsibility for damage or injury resulting from disregard for the information in the user documentation.
Check the GLP website at www.glp.de and make sure that you have the latest version of this manual. Check the fixture software version indicated on page 2 of this manual and then use the fixture’s control panel to check the version installed in the fixture. If the versions are not the same, this manual may still cover the fixture, because software updates do not always affect the way you use the fixture. However, it is possible that this manual does not match the fixture perfectly. Software release notes can help clarify this question. You can consult software release notes and download the correct version of this manual on the GLP website if necessary.
Make all user documentation available to all installers and operators. Save this document for future reference.
If you have any questions about the safe operation of the fixture, please contact an authorized GLP distributor (see list of distributors at www.glp.de).
Use the fixture only as directed in this manual. Observe all markings in this manual and on the fixture.
Refer all repairs and any service operation not described in this manual to a technician authorized by GLP.
The light source in this fixture must not be changed by the end user.
Read and follow the user documentation for all additional equipment.
Electrical safety
Do not allow the fixture to become immersed. Do not expose the fixture to high­pressure water projections.
Keep any unused connectors on the fixture sealed with their protective caps at all times, both when the fixture is in use and when not in use.
Use only a source of AC mains power that complies with local building and electrical codes and has both overload and ground fault (earth fault) protection.
Ensure that the fixture is electrically connected to ground (earth).
Disconnect the fixture from AC mains power before carrying out any installation or
maintenance work and when the fixture is not in use.
Disconnect the fixture from power immediately if any seal, cover, cable, connector or other component is damaged, defective, deformed or showing signs of overheating. Do not reapply power until the fixture has been repaired and made safe by a technician authorized by GLP.
Check that all power distribution equipment, cables and connectors are in perfect condition, rated for the electrical requirements of all connected devices, suitable for their application and suitable for the installation environment.
6 EXO Wash User Manual Rev. B
German Light Products® Safety
Use only Neutrik PowerCON TRUE1 cable connectors for AC mains power input at the fixture’s Mains IN connector and for relaying AC mains power from one fixture’s Mains OUT (Thru) connector to another fixture’s Mains IN connector.
Use minimum 14 AWG or 1.5 mm2 power input and relay cables that are minimum 16 A-rated and temperature-rated to suit the application. In the USA and Canada the cables must be UL-listed, type SJT or equivalent. In the EU the cables must be type H05VV-F or equivalent.
Do not connect devices to power in a chain if the total maximum current draw of all the devices in the chain when added together will exceed the current rating of any cable or connector used at any point in the chain. The supplied power input cable is rated as follows:
- US power cable: 16 A, 14 AWG, UL-listed, E304117, SJT, 4.9 ft.
- EU power cable: 16 A, 1.5 mm², H07RN-F, 1.5 m.
Do not connect more than four (4) Fusion EXO Wash 30 fixtures to power in a chain at 100-120 V, 60 Hz.
Do not connect more than eight (8) Fusion EXO Wash 30 fixtures to power in a chain at 200-240 V, 50 Hz.
The voltage and frequency at the Mains OUT socket are the same as the voltage and frequency applied to the Mains IN socket. Only connect devices to the Mains Out socket that accept this voltage and frequency.
Fusion EXO Wash 30 fixtures do not have a user-replaceable fuse. If you suspect that a fuse has blown, disconnect the fixture from power and send it to a technician authorized by GLP for repair.
Fire safety and protection from burns
Do not operate the fixture if the ambient temperature (Ta) exceeds 40° C / 104° F.
The surface of the fixture’s casing can reach up to 90° C / 194° F during operation.
Avoid contact by persons and materials. Do not install the fixture in a location where there is a risk of accidental contact. Allow the fixture to cool for at least 20 minutes before handling
Keep the fixture well away from flammable materials.
Keep all combustible materials (e.g. fabric, wood, paper) at least 0.5 m / 20 in.
away from the fixture.
Ensure that there is free and unobstructed airflow around the fixture.
Do not illuminate surfaces within 0.5 m / 20 in. of the fixture. The light output from the
fixture is powerful enough to cause burns or fire in illuminated objects at very close range.
Do not stick filters, masks or other materials onto the fixture. Do not block the light output in any way. The front surface becomes hot during operation and can melt or
EXO Wash 30 User Manual Rev. B 7
www.glp.de Safety
ignite objects that are in contact with the surface. Ensure that the front surface Is clean and unobstructed at all times in order to prevent a fire hazard and damage to the fixture.
The fixture’s optical components can focus the sun’s rays, creating a risk of fire and damage. Do not expose the front of the fixture to sunlight or any other intense light source, even from an angle.
Eye safety
The EXO Wash 30 is classified as a Risk Group 3 lighting fixture according to EN 62471. Possibly hazardous radiation emitted. Do not stare into the light output from the fixture. May be harmful to the eyes.
Do not look at the fixture’s light output with optical instruments or any device that may concentrate the light output.
Make sure that persons near to or working on the fixture are not looking directly into the light output when the fixture lights up suddenly. This can happen when power is applied, when the fixture receives a DMX signal, or when certain control menu items are selected.
The warning below is printed on the fixture. If the warning becomes impossible to read, replace it with a label reproduced from this illustration:
Provide well-lit conditions to reduce the pupil diameter of anyone working on or near the fixture.
Strobe safety
Flashing light, particularly at 5 - 30 Hz, may cause seizures in persons with photosensitive epilepsy. Do not use strobe effects for extended periods.
Comply with local regulations on the use of strobe lighting and notify the public in advance with highly visible warning signs when strobe effects are used.
If a seizure occurs, stop using strobe effects. Seek professional medical help. Note the time that the seizure starts and finishes. Call emergency medical help urgently if
8 EXO Wash User Manual Rev. B
German Light Products® Safety
the seizure lasts more than five minutes, if it is the person’s first seizure, or if the person is injured. While waiting for help to arrive, protect the affected person from injuring themselves on hard or sharp objects. If necessary, move the person to a safe place. Lay them on their side with their head supported to prevent it from hitting the floor. Loosen any tight clothing around their neck. Do not use force to hold the person or restrict their movements. Do not put anything in their mouth, including your fingers.
Installation safety and protection from personal injury
Installation must be performed by qualified personnel only and carried out in accordance with all locally applicable regulations such as DIN VDE 0711-217.
The fixture is not portable when installed.
Ensure that the supporting structure and installation hardware used can hold at least
ten times the weight of the load that they support.
Fasten the fixture to a structure or surface only as directed in this manual and only with hardware that is specifically designed and rated for its purpose. Do not use a safety cable as the primary means of support. Check that installation hardware is in perfect condition. Fasteners must be steel grade 8.8 strength or better. Rigging clamps must be half-coupler type that completely encircle the rigging truss chord.
If the fixture is installed in a location where it may cause injury or damage if it falls, install as directed in this manual a safety cable or similar secondary attachment that will hold the fixture if a primary attachment fails. The secondary attachment must be approved by an official body such as TÜV as a safety attachment for the weight that it secures, it must comply with EN 60598-2-17 Section 17.6.6, and it must be able to support a static suspended load that is ten times the weight that it secures.
If the fixture is installed in a location where it may be exposed to forces such as wind pressure, vibration or movement, make sure that the installation can withstand these forces. Monitor weather forecasts constantly. Take down the installation immediately if there is any risk of weather conditions that could destabilize the installation.
Check that all covers and items of rigging hardware are secure before using the fixture. Do not operate the fixture with missing or damaged covers, shields or any optical component.
Restrict access below the work area and work from a stable platform whenever installing, servicing or moving the fixture.
If the fixture becomes damaged, stop using it immediately and disconnect it from power. Do not attempt to use a fixture that is obviously damaged.
Do not modify the fixture in any way not described in its user documentation.
Install genuine GLP parts only.
EXO Wash 30 User Manual Rev. B 9
www.glp.de Avoiding damage to the fixture
2. Avoiding damage to the fixture
Important! Follow the directions in this section carefully, or the fixture may suffer damage that is not covered by the product warranty.
General precautions
Do not drop the fixture or expose it to mechanical stress. Protect the onboard LCD display and control panel from shocks, or they may suffer
damage that is not covered by the product warranty. Do not expose the fixture to heat (from other lighting fixtures for example).
Clean optical components only as directed. Oils, solvents, and other chemicals commonly used for cleaning can damage the lens coatings and surfaces.
Use only original spare parts. Do not make any structural modifications to the fixture or you will void the product warranty.
Avoiding damage from light sources and heat
Do not point the front of the fixture towards the sun or other strong light sources. Strong light can cause internal damage to the fixture, melting components or starting an internal fire within seconds.
Figure 1. Avoiding damage from light sources
Damage can occur whether the fixture is powered on or off. See Figure 1. Damage can also occur if the light hits the front of the fixture at an angle: the fixture does not need to be pointing directly at the sun or other light source.
To avoid problems from strong light sources:
Do not expose the front of the fixture to sunlight or any other strong light source.
In outdoor applications during daylight, make sure that the front face of the fixture is
shielded or points away from the sun, even when not in use.
Do not aim other high-powered beam lights directly at the fixture.
Do not operate the fixture in ambient temperatures above 40° C / 104° F. Allow free airflow around the fixture.
10 EXO Wash User Manual Rev. B
German Light Products® Avoiding damage to the fixture
IP rating
EXO Wash 30 fixtures are IP65-rated:
IP stands for Ingress (entry into the fixture) Protection.
The first figure 6 in the rating means that fixtures are protected against the entry of
dust and airborne particles.
The second figure 5 in the rating means that fixtures are protected against the entry of rain and water projections from all angles. Fixtures are not protected against immersion in water and they are not protected against high-pressure water jets.
Avoiding damage from water and humidity
Do not install EXO Wash 30 fixtures in a location where water can pool around the fixture or allow EXO Wash 30 fixtures to become submerged in any other way. Do not aim low- or high-pressure water jets at fixtures.
Keep all unused connectors on the fixture sealed with their protective caps, both when the fixture is being used and when it is not in use.
In outdoor and high-humidity environments, use IP65-rated power and data connectors and cable (an IP65 rating means that the item is protected against the entry of water from rain, projections and low-pressure jets as well as the entry of dust). When assembling connectors and installing them on cable, follow the manufacturer’s instructions (see www.neutrik.com) and ensure that an IP65 rating is maintained for the complete assembly. Use only the following cable connectors:
- IP65-rated 5-pin XLR connectors for data IN and OUT (THRU)
- Neutrik powerCON TRUE1 NAC3FX-W for Power IN
- Neutrik powerCON TRUE1 NAC3MX-W for Power OUT (THRU).
Apply a dielectric grease (available from electrical suppliers) to connector terminals
and caps to prevent corrosion and/or electrical short circuits.
Make sure that cables open into dry areas or sealed junction boxes. Moisture can be drawn along cables by capillary action or pressure variations resulting from thermal expansion.
See drawing on right. Arrange cables so that they arrive at connectors from below. Make sure that it is impossible for water to flow down cables and accumulate at connectors. If necessary, provide extra cable slack and create ‘drip loops’ before connectors.
Create loose cable bends only. Do not subject connections to bending forces or allow connections to bear the weight of long lengths of cable.
EXO Wash 30 User Manual Rev. B 11
www.glp.de Avoiding damage to the fixture
Avoiding damage from dust and airborne particles
Carry out regular visual inspections of the fixture to make sure that there is no accumulation of dirt, especially on the front of the fixture.
If cleaning is necessary, follow the instructions in ‘Service’ on page 48.
Transportation and storage
Transport the fixture in its original packaging or a suitably designed flight case to protect it from damage caused by shocks during transportation.
Release the tilt lock and support the fixture’s head with the original packaging inserts or flight case inserts during transportation.
Store the fixture in a dry location when not in use.
GLP Service and Support
Contact information for the nearest GLP Service and Support is available online at www.glp.de/en/service, by email at info@glp.de, or by telephone at the following numbers:
GLP Germany: +49 (7248) 927 19-55
GLP N. America: +1 818 767-8899
GLP UK: +44 1392 690140
GLP Asia: +852 (3151) 7730
GLP Nordic: +46 737 57 11 40
12 EXO Wash User Manual Rev. B
German Light Products® EXO Wash 30 overview
3. EXO Wash 30 overview
The Fusion EXO Wash 30 from GLP is a powerful LED-based wash light fixture with fast pan and tilt, 4 to 54 degree variable zoom and seven independently controllable RGBW zones.
The fixture can be controlled by DMX or by settings on its built in color LCD control panel. An optional wireless DMX module can be fitted to enable LumenRadio wireless control. The fixture has a built-in battery to allow the display to be operated for setup before mains power is connected.
The EXO Wash 30 can be used indoors in permanent and temporary installations. Its rugged construction and IP65 rating mean that it can also be used outdoors in temporary installations if precautions are taken to prevent immersion in water and damage from direct sunlight. It can stand on a horizontal surface or be suspended from a suitable structure as described in Section 4.
The EXO Wash 30 is not suitable for household use, for use in any location where unattended children have access to it, or for use in permanent outdoor installations.
EXO Wash 30 User Manual Rev. B 13
www.glp.de EXO Wash 30 overview
8 – Wireless indicator
9 – Battery button
10 – PowerCON TRUE1 input
11 – Mode / Esc button
12 – Up button
13 – Down button
14 – Enter button
15 – Optional wireless antenna
16 – 5 pin XLR DMX input
17 – 5 pin XLR DMX link out
18 – Vent valve
19 – PowerCON TRUE1 link out
1 – Output lens
2 – Head
3 – Tilt lock
4 – Yoke
5 – Base
6 – Control panel
7 – Rubber feet
Figure 2. EXO Wash 30 overview
14 EXO Wash User Manual Rev. B
German Light Products® Installation
4. Installation
Warning! Read ‘Safety’ starting on page 5 for important safety information that you must understand before you install or operate the fixture. Install EXO Wash 30 fixtures only as described in this chapter, or you may create an installation that is unsafe.
Install the fixture at least 0.5 m / 20 in. away from combustible materials (wood, textiles, paper, etc.), 0.5 m / 20 in. away from any surface that will be illuminated, and a safe distance away from any flammable materials (volatile spirits, etc.).
It is the installer’s responsibility to provide a stable, secure supporting structure that is suitable for the environment and application and that meets all applicable codes and legal requirements. Note the requirement to secure lighting fixtures with safety cables in temporary installations.
Permitted mounting options
An EXO Wash 30 fixture may be installed in one of the following ways:
1. Fastened to a rigging truss or similar structure at any angle by means of truss couplers or other clamps fixed to the two Omega brackets which attach to the half-turn couplers on the underside of the base.
2. Standing upright on the base on a horizontal surface.
Securing fixtures with a safety cable
In temporary installations, if a fixture can cause injury or damage if it falls you must secure it with a secondary attachment such as a safety cable that will hold it if the primary means of attachment fails. The safety cable must be approved for the weight that it secures. In multiple installations, each fixture must have its own safety cable.
EXO Wash 30 User Manual Rev. B 15
www.glp.de Installation
To secure an EXO Wash 30 fixture with a safety cable:
Figure 3. Safety cable attachment
1. Loop a safety cable around a secure anchoring point such as a truss beam or fixed structure so that it will catch the fixture if a rigging clamp fails. Take up as much slack as possible in the safety cable (by looping it more than once around the bar, for example).
2. See Figure 3 and Figure 4. Fasten the safety cable through the slot “B” on the underside of the fixture base. Check that the fixture is now secured.
Installing on a rigging truss or similar structure
You can suspend an EXO Wash 30 fixture from a rigging truss or pipe using suitable clamps attached to the Omega Brackets supplied with the EXO Wash 30.
If you are going to install the fixture hanging vertically downwards from a horizontal rigging truss or pipe, you can fasten it to the truss using G-clamps. If you are going to install the fixture in any other orientation, you must use half-coupler clamps that completely surround the truss chord or pipe.
16 EXO Wash User Manual Rev. B
German Light Products® Installation
Figure 4. Omega bracket fasteners
1. Attach suitable clamps to the Omega brackets.
2. Line up the fasteners of the Omega bracket with the holes “A” in the base of the EXO Wash 30 as shown in Figure 4. The brackets may be installed either way round so the cabling is in line with the bar or at right angles to it.
3. Lock the Omega brackets onto the EXO Wash 30 by turning the fasteners through 90 degrees.
4. Attach the clamp to the truss or structure. Ensure that the head and yoke of the fixture will not collide with any fixed objects as the fixture moves. Ensure that the fixture has sufficient clearance to any adjacent surfaces or objects.
5. Secure the fixture with a safety cable through slots “B” as described in the previous section.
Standing on a horizontal surface
To install an EXO Wash 30 fixture on a horizontal surface:
1. Check that the surface is secure and can safely hold the weight of the fixture plus all hardware and cables.
2. Stand the fixture firmly on the rubber feet fitted to the base of the unit. Ensure that the head and yoke of the fixture will not collide with any fixed objects as the fixture moves. Ensure that the fixture has sufficient clearance to any adjacent surfaces or objects.
EXO Wash 30 User Manual Rev. B 17
www.glp.de AC mains power
5. AC mains power
Warning! Read ‘Safety’ starting on page 5 for important safety information that you must understand before you install or operate the fixture.
Check that all cables and connectors are suitable for the installation environment and application (see recommendations in ‘Avoiding damage to the fixture’ on page 10).
Use H07 RN-F 3 x 2.5mm / SJT 12 AWG cables with original Neutrik powerCON TRUE1 connectors to supply power to fixtures.
Line up the keyways in connectors carefully. Do not try to insert or twist a connector if it feels excessively stiff. Resistance to insertion or twisting is a sign that connectors may be incorrectly lined up.
Keep connectors sealed with their rubber caps at all times when not in use.
Included items
The EXO Wash 30 is supplied with a power cord with Neutrik powerCON TRUE1 connector.
Connecting to power
The AC mains power supply must include a connection to ground / protective earth. It must be protected against ground / earth leakage and overload. The fixture’s internal auto-sensing power supply accepts AC power at 100-240 V, 50/60 Hz. Do not connect the fixture to power at any other voltage or to an external dimmer.
The EXO Wash 30 does not have a power ON/OFF switch. Power is applied to the fixture as soon as the power cable becomes live.
The EXO Wash 30 has a 3-conductor Neutrik powerCON TRUE1 Mains IN power input socket that accepts AC power from a TRUE1 female cable connector. Although TRUE1 connectors support hot plugging, it is still good practice to shut down power to power cables before connecting them to fixtures.
To connect the fixture to power:
1. If convenient, shut down power to the power input cable.
2. Note the position of the keys and keyways on the TRUE1 power cable connector and Mains IN socket and align them with each other. Insert the cable connector into the socket and twist clockwise to lock. Do not use force. If the connector feels excessively stiff, remove it and check again that it is lined up correctly.
3. Before applying power to the power cable, check that nobody is looking directly into the front of the fixture.
To disconnect the fixture from power, pull the latch on the cable connector outwards to release it, then twist the connector counterclockwise and pull to remove it from the socket.
18 EXO Wash User Manual Rev. B
German Light Products® AC mains power
Live or L
Neutral or N
Ground / Earth or
US system
Black
White
Green
EU system
Brown
Blue
Yellow/green
Installing power connectors
If you intend to draw power from convenience receptacles / consumer mains power sockets, it is possible to install a suitable cord cap / power plug on the supplied power cord / input cable. If you do this, check that the cord cap / plug is rated minimum 250 V, 16 A, that it has a connection to ground / earth and that it has an integral cable grip. Follow the cord cap / plug manufacturer’s assembly instructions.
If you need to install a Neutrik powerCON TRUE1 connector on a power cable, follow the instructions given in the Support area of the Neutrik website at www.neutrik.com.
Respect the color coding used in the supplied power cable and in your local mains power wiring system. US and EU systems use the color coding shown below:
Connecting multiple fixtures to power in a chain
You can connect fixtures to power in a daisy-chain to simplify your power circuit layout.
EXO Wash 30 fixtures have 2.5 mm2 internal wiring from Power IN to Power THRU connectors.
Warning! Do not connect more than four (4) EXO Wash 30 fixtures in total to power in one chain at 100-120 V, 60 Hz. Do not connect more than eight (8) EXO Wash 30 fixtures in total to power in one chain at 200-240 V, 50 Hz.
The power input cable supplied with the fixture is rated 16 A maximum. Add together the maximum current draw ratings of all the devices that you intend to connect to power in a daisy chain and do not create a chain with a total maximum current draw of more than 16 A, or you will create a risk of fire and electric shock.
To connect fixtures to power in a chain:
1. Obtain power relay cables that have male and female Neutrik powerCON TRUE1 connectors. Cables must be minimum 14 AWG or 1.5mm2, rated minimum 16 A and suitable for the environment and application.
EXO Wash 30 User Manual Rev. B 19
2. Connect the power input cable to the Mains IN socket of the first fixture as described under ‘Connecting to power’ on page 18.
3. Connect a relay cable to the Mains OUT / THRU socket of the first fixture and to the Mains IN socket of the second fixture.
4. If you are using 100-120 V, 60 Hz AC mains power you can continue connecting EXO Wash 30 fixtures Mains OUT / THRU socket to Mains IN socket until the chain contains a maximum of four (4) fixtures in total. If you are using 200-240 V, 50 Hz AC mains power you can continue connecting fixtures Mains OUT to Mains IN until the chain contains a maximum of eight (8) fixtures total.
www.glp.de Connecting to DMX data
1
Signal Ground
2
Data –
3
Data +
4
Not used
5
Not used
6. Connecting to DMX data
Check that all cables and connectors are suitable for the installation environment and application (see recommendations in ‘Avoiding damage to the fixture’ on page 10).
Use digital 110 Ohm DMX cable with IP65 5-pin XLR connectors to supply DMX data to fixtures.
Keep connectors sealed with their rubber caps at all times when not in use. The EXO Wash 30 has two 5-pin XLR sockets for IN and THRU connections to a DMX
data link. EXO Wash 30 fixtures support the USITT DMX 512A signal protocol. They also support RDM (Remote Device Management).
The 5-pin XLR connectors use standard pin allocations:
The DMX cable should start at the console and be daisy-chained through each fixture to be controlled using the DMX input and DMX link out connectors. If you need to split the DMX cable, use a powered DMX splitter.
If you would like advice with planning and installing a DMX link, your GLP supplier will be happy to provide assistance.
20 EXO Wash User Manual Rev. B
German Light Products® Starting and stopping operation
7. Starting and stopping operation
Warning! Before you apply power to the fixture or operate it after a blackout, make sure that nobody is looking directly into the front of the fixture.
The EXO Wash 30’s TRUE1 mains power input connector supports hot-plugging, and connecting and disconnecting a live power cable is an option, especially if you need to shut down power urgently, but it is still good practice to shut down power to the AC mains power circuit before connecting and disconnecting power cables.
To start operation, check that nobody is looking into the front of the fixture, then apply power to the AC mains power circuit.
To stop operation, shut down power to the AC mains power circuit.
EXO Wash 30 User Manual Rev. B 21
www.glp.de Features
8. Features
The EXO Wash 30 unit has the following features:
Position
Pan rotation 630°(3.9 sec) or 540°(4.3 sec),Tilt rotation 267°(2.2 sec) with 16 bit resolution. The fixture will automatically reposition if knocked – this option can be disabled from the menu. The Pan and Tilt movements can be inverted using the menu.
Color
The fixture has seven zones of Red/Green/Blue/White (RGBW) color mixing LEDs. Depending on the DMX mode these have up to 16-bit dimming and can be controlled independently, or using macro patterns.
The zones/pixels are arranged as shown in the diagram below.
Figure 5. Pixel order
22 EXO Wash User Manual Rev. B
German Light Products® Features
Figure 6. Dimming curves
Dimming
See Figure 6. You can select from two dimming curves using the control panel or the Control / Settings DMX channel:
Linear sets dimming so that it appears to increase and decrease evenly throughout the dimming range.
Soft gives finer control at low light levels and coarser control at high light levels.
The default setting is Soft.
Strobe / shutter
A variety of strobing and fading effects can be produced by the fixture.
Zoom
The beam angle of the fixture can be adjusted (zoom) from 4° to 54°. The zoom operation can be inverted using the menu.
Behavior when the fixture is not receiving a DMX signal
You can set the fixture to react in three different ways if no DMX signal is present (if the fixture is being controlled by DMX but the DMX signal stops, or if you apply power to the fixture when no DMX signal is present):
Blackout sets the fixture to black out. This is the default setting.
Hold sets the fixture to continue obeying the last DMX values it received. If no DMX
signal was being received, the fixture will black out.
Preset Scene sets the fixture to output a preset scene which you have previously captured from an incoming DMX state using the Manual Control > Capture Scene menu option. You can also manually set the control values (or edit the captured values) using the attribute settings in the Manual Control menu.
All these settings are available via DMX on the Control / Settings channel and in the fixture’s control panel.
EXO Wash 30 User Manual Rev. B 23
www.glp.de Control menus and onboard display
9. Control menus and onboard display
Warning! DMX control is disabled when the control menus are active. Be prepared for the fixture to emit strong light as soon as you exit the control menus.
The control panel and onboard LCD display provide access to user settings, readouts and utilities.
Figure 7. Onboard display
The four control buttons have the following functions:
MODE/ESC: Activate the menus or go back one level towards the top of the menu.
UP: Scroll up or increase a number. DOWN: Scroll down or reduce a number. ENTER: Activate the control panel if it is in sleep mode. Then enter a menu, select
a setting or implement a command.
When you apply power to the fixture, it boots up. After it has booted, the panel displays the default screen.
The Battery button is used to power up the control panel for setup before mains is connected to the unit. Battery mode can be disabled in the menu.
The W-DMX indicator shows when wireless DMX is being received, if the optional wireless module has been fitted.
24 EXO Wash User Manual Rev. B
German Light Products® Control menus and onboard display
DMX control is disabled when the control menus are active.
Display options
The illuminated LCD display lets you change fixture settings. The display has a battery backup so that you can change the settings before mains is connected to the fixture. See Chapter 9 for more details.
Using the Control / Settings DMX channel or the fixture’s control panel you can: Set display modes using the Fixture Settings > Display Mode option:
- On: The display stays on constantly. This setting can be useful when you are configuring or servicing the fixture.
- Auto: The display will automatically switch off after a few seconds even if the fixture is not receiving a valid control signal or if it has detected an error.
Invert the display using the Fixture Settings > Display Orientation option, so it is easier to read if the fixture is hanging upside down.
Display Locking
On the Fixture Settings > Lock menu, you can configure the display to lock after a period of time to prevent accidental changes to the options.
You can set a custom lock code using the Fixture Settings > Lock > Set Passcode option. If you do not set a custom code, the default code is 0000.
Manual Control
Using the Manual Control menu you can set fixed values to the fixture’s control channels, as if it was in DMX control mode 1. This is useful when testing.
LED PWM frequency
The LEDs in the unit are dimmed using Pulse Width Modulation (PWM) which can sometimes cause flickering on cameras. The Fixture Settings > PWM option allows you to select different frequencies for the PWM to fix such issues. The higher frequencies may cause reduced dimming performance.
Fan control
The fixture has internal cooling fans. In a noise critical situation you can slow these down using the Fixture Settings > Fan Mode option. The normal setting is Regulated which will adjust the fan speed automatically. If you set the option to Low the fan speed is kept slow but this may result in the fixture overheating and reducing its output.
The fixture has an additional fan near the lens to clear condensation. You can control how this fan works using the Fixture Settings > Defog option.
Fixture information
The Information menu in the control panel gives access to items of information from the fixture’s sensors and memory. You can check temperature sensor readouts, see total operating hours counters, and see software version number, for example.
EXO Wash 30 User Manual Rev. B 25
www.glp.de Control menus and onboard display
Pan disable / Tilt disable
These options allow you to disable the startup reset movements or disable the drive of the pan and/or tilt motors. The options are
- Off: Normal motor control
- Reset Disabled: The fixture will not do its power on reset sequence on this motor but
the motor is still controlled. This can be used when a fixture is mounted in a confined space and would collide with an obstruction if it did the reset sequence.
- Current Disabled: The motor drive function is completely disabled. This is mostly used for service or diagnostics.
Preset settings and factory defaults
You can store three different versions of option settings using the Service > Service Advanced > Save Settings menu and load them using the Load Settings > Preset 1-2-3
options. These allow you to quickly set up the fixture in a particular configuration. Settings are stored after a power off/on cycle and after a reset.
Two options are available in the fixture’s control panel for deleting multiple custom settings and restoring defaults:
- Service > Default Settings reloads all the fixture’s factory default settings except DMX address, DMX mode, captured scene, preset settings and offset values. This option returns the fixture to baseline settings without affecting its basic configuration in an installation.
- Service > Service Advanced > Factory Backup reloads all the fixture’s factory default settings including DMX address, DMX mode, and erases all storage. This option reinitializes the fixture completely and returns to its state when it left the factory.
-
26 EXO Wash User Manual Rev. B
German Light Products® Control menu layout
Menus
Notes
DMX ADDRESS
1 - 512
Enter DMX address
CONTROL MODE
Compressed – 13 channels
Select DMX control mode
Standard – 22 channels
Extended – 37 channels
Pixel – 50 channels
CONTROL PROTOCOL
DMX
Wired DMX control
WIRELESS
Wireless DMX control (optional module)
FIXTURE SETTINGS
Pan Invert
Off / On
Invert Pan movement
Tilt Invert
Off / On
Invert Tilt movement
Position Feedback
Off / On
If On, fixture repositions if knocked
Pan Disabled
Off / Reset Disabled / Current Disabled
Disable motor drive for service
Tilt Disabled
Off / Reset Disabled / Current Disabled
Zoom Invert
Off / On
Inverts Zoom movement
Dimmer Curve
Soft (Gamma) / Linear
Dimming curve
No Signal
Blackout / Hold / run Captured Scene
Action when no DMX signal
Capture Scene
Press ENTER to capture scene
Store scene for no signal
PWM
600 Hz / 2200 Hz / 3000 Hz / 4800 Hz / 9600 Hz / 25000 Hz
Frequency of LED dimming
Display Mode
Auto / On / Off
Display blanking
Display Orientation
Normal / Upside Down
Display reversing
Max Temperature
60 – 90C / 140-194F
Sets overheat temperature where shutdown will occur
Fan Mode
Regulated / High / Medium / Low
Set fan speed control
Load Settings
Preset 1 / Preset 2 / Preset 3
Press ENTER for 3 sec to confirm
Lock
Off / On /. Set Passcode
Lock the control panel
Defog
Off / On / Quick
Settings for lens defogging fan
Battery
On / Off
Disable the battery operation of the control panel
MANUAL CONTROL
Reboot
Press ENTER for 3 sec to confirm
Manual function control (DMX Mode 1)
Pan Coarse 0-255
These values can be set manually or from a DMX state using Capture Scene option
Pan Fine 0-255
Tilt Coarse 0-255
Tilt Fine 0-255
Dimmer 0-255
Shutter 0-255
Virtual color wheel 0-255
10. Control menu layout
EXO Wash 30 User Manual Rev. B 27
www.glp.de Control menu layout
Red 0-255
Green 0-255
Blue 0-255
White 0-255
Zoom 0-255
Control 0-255
Capture Scene
Press ENTER for 3 sec to capture incoming DMX state
INFORMATIO N
Firmware Version
ver x.x
Fixture firmware version
Fixture Details
Serial … xx / RDM … xx
Show fixture serial, RDM unique ID
Device Life
Total / User
Shows power cycles, Power Hours, LED Hours
DMX Link Status
Refresh Rate (Hz) / Frame Length / Mode Length
Details of DMX signal
Temperatures
xxx…
Unit temperatures
Fan Speeds
Fan1 …
Error Log
Xxx
SERVICE
Test All
Running
Press Enter to start test, Menu or Enter to stop
Test Pan only
Running
Test Tilt only
Running
Test LED only
Running
Test Zoom only
Running
Default Settings
See Note 1 below
Service Advanced
See below for menu
Hold Enter for 6 sec to enter this menu
FACTORY MENU
This menu is for use by authorized service technicians only
Note 1: Default Setting will return all options to default except DMX address, Control Mode. It does not erase captured scene, preset settings or offset values
Default settings are written in BOLD type.
28 EXO Wash User Manual Rev. B
German Light Products® Control menu layout
Menus
Notes
Pan Disable
Off/On
Tilt Disable
Off/On
Units
°C / °F
Offsets
Tilt
xxx
Zoom
xxx
Reset Counter
Power Hours
Power Cycles
LED Hours
Max Temperature
Temperature Unit
Save Settings
Preset 1
Preset 2
Preset 3
Factory Backup
See Note 2 below
Service Advanced menu
Hold down Enter for 6 seconds to access this menu.
Note 2: Factory backup will reset all options to default, erase captured scene, erase preset settings, erase offset values. User Hour counter and Temperature Unit will not be affected.
EXO Wash 30 User Manual Rev. B 29
www.glp.de DMX control modes overview
DMX Mode 1: Compact Compact Mode uses 13 DMX
channels. It provides 16-bit control of pan and tilt,
dimming and a shutter with strobe and ramp up/down effects. It has a virtual color wheel effect (color presets with rotation effects) and RGBW color mixing.
Compact Mode also provides control of zoom and a control / settings channel that lets you configure the feature and adjust settings remotely via DMX.
Mode 1
Compact
1
Pan 2 Pan fine
3
Tilt
4
Tilt fine
5
Dimmer
6
Shutter
7
Virtual color wheel
8
Red 9 Green
10
Blue
11
White
12
Zoom
13
Control / Settings
DMX Mode 2: Standard Standard Mode uses 22 DMX channels.
It provides 16-bit control of pan and tilt, 16-bit control of dimming and a shutter with strobe and ramp up/down effects. It has a virtual color wheel effect (color presets with rotation effects), color temperature control and 16-bit RGBW color mixing.
Standard Mode also gives access to a range of Pattern FX with variable speed and crossfading parameters, control of zoom and a control / settings channel that lets you configure the feature and adjust settings remotely via DMX.
Mode 2
Standard
1
Pan
2
Pan fine
3
Tilt
4
Tilt fine
5
Dimmer
6
Dimmer fine
7
Shutter
8
Virtual color wheel
9
CTC
10
Red
11
Red fine
12
Green
13
Green fine
14
Blue
15
Blue fine
16
White
17
White fine
18
Pattern
19
Pattern Speed
20
Pattern Fading
21
Zoom
22
Control / Settings
11. DMX control modes overview
The following DMX control modes are available in the EXO Wash 30.
30 EXO Wash User Manual Rev. B
German Light Products® DMX control modes overview
DMX Mode 3: Extended Extended Mode uses 37 DMX channels. It provides 16-bit control of pan and tilt,
16-bit control of dimming and a shutter with strobe and ramp up/down effects. It has a virtual color wheel effect (color presets with rotation effects), color temperature control and 16-bit RGBW color mixing.
Extended Mode also has two layers:
Layer 1, the background layer, has 16-bit color dimming and a shutter effect that includes a random pixel strobe.
Layer 2, the top layer, has a range of Pattern FX with 16-bit dimming, shutter effects and color control via a virtual color wheel (color presets) and 16-bit RGBW color mixing. Layer 2 also has variable speed and crossfading parameters
Extended Mode also provides control of zoom and a control / settings channel that lets you configure the feature and adjust settings remotely via DMX.
Mode 3
Extended
1
Pan
2
Pan fine
3
Tilt
4
Tilt fine
5
Dimmer
6
Dimmer fine
7
Shutter
8
Virtual color wheel
9
CTC
10
Red
11
Red fine
12
Green
13
Green fine
14
Blue
15
Blue fine
16
White
17
White fine
18
Layer 1 Color dimmer
19
Layer 1 Color dimmer fine
20
Layer 1 Shutter
21
Layer 2 Pattern dimmer
22
Layer 2 Pattern dimmer fine
23
Layer 2 Pattern shutter
24
Layer 2 Pattern color wheel
25
Layer 2 Pattern red
26
Layer 2 Pattern red fine
27
Layer 2 Pattern green
28
Layer 2 Pattern green fine
29
Layer 2 Pattern blue
30
Layer 2 Pattern blue fine
31
Layer 2 Pattern white
32
Layer 2 Pattern white fine
33
Layer 2 Pattern
34
Layer 2 Pattern speed
35
Layer 2 Pattern fading
36
Zoom
37
Control / Settings
EXO Wash 30 User Manual Rev. B 31
www.glp.de DMX control modes overview
DMX Mode 4: Pix Pix Mode uses 50 DMX channels.
It provides 16-bit control of pan and tilt, 16-bit control of dimming and a shutter with strobe and ramp up/down effects. It has a virtual color wheel effect (color presets with rotation effects), color temperature control and 16-bit RGBW color mixing.
Pix Mode also gives access to a range of Pattern FX with variable speed and crossfading parameters, control of zoom and a control / settings channel that lets you configure the feature and adjust settings remotely via DMX.
Finally, Pix Mode provides independent RGBW color mixing on each of the fixture’s seven pixels.
Mode 4
Pix
1
Pan
2
Pan fine
3
Tilt
4
Tilt fine
5
Dimmer
6
Dimmer fine
7
Shutter
8
Virtual color wheel
9
CTC
10
Red
11
Red fine
12
Green
13
Green fine
14
Blue
15
Blue fine
16
White
17
White fine
18
Pattern
19
Pattern Speed
20
Pattern Fading
21
Zoom
22
Control / Settings
23
Pixel 1 Red
24
Pixel 1 Green
25
Pixel 1 Blue
26
Pixel 1 White
27
Pixel 2 Red
28
Pixel 2 Green
29
Pixel 2 Blue
30
Pixel 2 White
31
Pixel 3 Red
32
Pixel 3 Green
33
Pixel 3 Blue
34
Pixel 3 White
35
Pixel 4 Red
36
Pixel 4 Green
37
Pixel 4 Blue
38
Pixel 4 White
39
Pixel 5 Red
40
Pixel 5 Green
41
Pixel 5 Blue
42
Pixel 5 White
43
Pixel 6 Red
44
Pixel 6 Green
45
Pixel 6 Blue
46
Pixel 6 White
47
Pixel 7 Red
48
Pixel 7 Green
49
Pixel 7 Blue
50
Pixel 7 White
32 EXO Wash User Manual Rev. B
German Light Products® DMX MODE 1
Channel
Command
DMX
range
Percent
Default
DMX
Fade
1
Pan
Pan left–right
0
65535
0
100
32767
Fade
2
Pan fine
3
Tilt
Tilt up–down
0
65535
0
100
32767
Fade
4
Tilt fine
5
Dimmer
Intensity 0–100%
0
255 0 100
0
Fade
6
Shutter
Shutter closed
0 4 0
1.6
0
Snap
Single flash when change on dimmer channel
5 9 2.0
3.5
Sync ramp up slow–fast
10
39
3.9
15.3
Sync ramp down slow–fast
40
69
15.7
27.1
Sync ramp up-down slow–fast
70
99
27.5
38.8
Sync double flash (slow–fast)
100
129
39.2
50.6
Random strobe pixel (slow–fast)
130
159
51.0
62.4
Random strobe all (slow–fast)
160
199
62.7
78.0
Sync strobe (1 Hz–10 Hz)
200
250
78.4
98.0
Shutter open
251
255
98.4
100
7
Color wheel effect
Off (RGBW)
0 7 0
2.7
0
Snap
Color 01 - Red
8
15
3.1
5.9
Snap
Color 02 - Amber
16
23
6.3
9.0
Snap
Color 03 - Warm Yellow
24
31
9.4
12.2
Snap
Color 04 - Yellow
32
39
12.5
15.3
Snap
Color 05 - Green
40
47
15.7
18.4
Snap
Color 06 - Turquoise
48
55
18.8
21.6
Snap
Color 07 - Cyan
56
63
22.0
24.7
Snap
Color 08 - Blue
64
71
25.1
27.8
Snap
Color 09 - Lavender
72
79
28.2
31.0
Snap
Color 10 - Mauve
80
87
31.4
34.1
Snap
Color 11 - Magenta
88
95
34.5
37.3
Snap
Color 12 - Pink
96
103
37.6
40.4
Snap
Color 13 - White 3200K
104
111
40.8
43.5
Snap
Color 14 - White 5600K
112
119
43.9
46.7
Snap
Color 15 - White 7200K
120
127
47.1
49.8
Snap
Stop
128
128
50.2
50.2
Snap
Rainbow colors crossfade slow > fast
129
223
50.6
87.5
Fade
Random colors crossfade slow > fast
224
255
87.8
100
Fade
8
Red
Red intensity 0-100%
0
255 0 100
0
Fade
9
Green
Green intensity 0-100%
0
255 0 100
0
Fade
10
Blue
Blue intensity 0-100%
0
255 0 100
0
Fade
11
White
White intensity 0-100%
0
255 0 100
0
Fade
12
Zoom
Wide–narrow
0
255 0 100
0
Fade
12. DMX control channel layout tables
DMX Mode 1: Compact
11 DMX Channels
EXO Wash 30 User Manual Rev. B 33
www.glp.de DMX MODE 1
13
Control / Settings
No function
0 9 0.0
3.5
0
Snap
Dimmer curve: Extra-soft (3s hold)
10
15
3.9
5.9
Dimmer curve: Linear (3s hold)
16
21
6.3
8.2
Display mode: Auto (3s hold)
22
27
8.6
10.6
Display mode: On (3s hold)
28
33
11.0
12.9
Display mode: Off (3s hold)
34
39
13.3
15.3
Display orientation: Normal (3s hold)
40
45
15.7
17.6
Display orientation: Inverted (3s hold)
46
51
18.0
20.0
No DMX: Blackout (3s hold)
52
57
20.4
22.4
No DMX: Hold (3s hold)
58
63
22.7
24.7
No DMX: Stand-alone (3s hold)
64
69
25.1
27.1
Fan mode: Regulated (3s hold)
70
75
27.5
29.4
Fan mode: High (3s hold)
76
81
29.8
31.8
Fan mode: Medium (3s hold)
82
87
32.2
34.1
Fan mode: Low (3s hold)
88
93
34.5
36.5
Position feedback: Off (3s hold)
94
99
36.9
38.8
Position feedback: On (3s hold)
100
105
39.2
41.2
No function
106
117
41.6
45.9
Tilt inversion: Off (3s hold)
118
123
46.3
48.2
Tilt inversion: On (3s hold)
124
129
48.6
50.6
Pan inversion: Off (3s hold)
130
135
51.0
52.9
Pan inversion: On (3s hold)
136
141
53.3
55.3
Zoom inversion: Off (3s hold)
142
147
55.7
57.6
Zoom inversion: On (3s hold)
148
153
58.0
60.0
Defog: Off
154
159
60.4
62.4
Defog: On
160
165
62.7
64.7
Defog: Quick
166
171
65.1
67.1
Load Settings Preset1
172
177
67.5
69.4
Load Settings Preset2
178
183
69.8
71.8
Load Settings Preset3
184
189
72.2
74.1
PWM 600 Hz (5s hold)
190
195
74.5
76.5
PWM: 2200 Hz (5s hold)
196
201
76.9
78.8
PWM: 3000 Hz (5s hold)
202
207
79.2
81.2
PWM: 4800 Hz (5s hold)
208
213
81.6
83.5
PWM: 9600 Hz (5s hold)
214
219
83.9
85.9
PWM: 25 kHz (5s hold)
220
225
86.3
88.2
No function
226
231
88.6
90.6
Return to default settings
232
237
91.0
92.9
Reset Pan/Tilt (3s hold)
238
243
93.3
95.3
Reset Head (3s hold)
244
249
95.7
97.6
Reset All (3s hold)
250
255
98.0
100
34 EXO Wash User Manual Rev. B
German Light Products® DMX MODE 2
Channel
Command
DMX
range
Percent
Defaul
t DMX
Fade
1
Pan
Pan left–right
0
65535
0
100
32767
Fade
2
Pan fine
3
Tilt
Tilt up–down
0
65535
0
100
32767
Fade
4
Tilt fine
5
Dimmer
Intensity 0–100%
0
65535
0
100
32767
Fade
6
Dimmer fine
7
Shutter
Shutter closed
0 4 0
1.6
0
Snap
Single flash when change on dimmer channel
5 9 2.0
3.5
Sync ramp up slow–fast
10
39
3.9
15.3
Sync ramp down slow–fast
40
69
15.7
27.1
Sync ramp up-down slow–fast
70
99
27.5
38.8
Sync double flash (slow–fast)
100
129
39.2
50.6
Random strobe pixel (slow–fast)
130
159
51.0
62.4
Random strobe all (slow–fast)
160
199
62.7
78.0
Sync strobe (1 Hz–10 Hz)
200
250
78.4
98.0
Shutter open
251
255
98.4
100
8
Color wheel effect
Off (RGBW)
0 7 0
2.7
0
Snap
Color 01 - Red
8
15
3.1
5.9
Snap
Color 02 - Amber
16
23
6.3
9.0
Snap
Color 03 - Warm Yellow
24
31
9.4
12.2
Snap
Color 04 - Yellow
32
39
12.5
15.3
Snap
Color 05 - Green
40
47
15.7
18.4
Snap
Color 06 - Turquoise
48
55
18.8
21.6
Snap
Color 07 - Cyan
56
63
22.0
24.7
Snap
Color 08 - Blue
64
71
25.1
27.8
Snap
Color 09 - Lavender
72
79
28.2
31.0
Snap
Color 10 - Mauve
80
87
31.4
34.1
Snap
Color 11 - Magenta
88
95
34.5
37.3
Snap
Color 12 - Pink
96
103
37.6
40.4
Snap
Color 13 - White 3200K
104
111
40.8
43.5
Snap
Color 14 - White 5600K
112
119
43.9
46.7
Snap
Color 15 - White 7200K
120
127
47.1
49.8
Snap
Stop
128
128
50.2
50.2
Snap
Rainbow colors crossfade slow > fast
129
223
50.6
87.5
Fade
Random colors crossfade slow > fast
224
255
87.8
100
Fade
9
Color Temperature (Kelvin)
RAW 0 15 0 5.9
Snap
10000
16
18
6.3
7.1
9900
19
21
7.5
8.2
9800
22
24
8.6
9.4
9700
25
27
9.8
10.6
9600
28
30
11.0
11.8
9500
31
33
12.2
12.9
9400
34
36
13.3
14.1
9300
37
39
14.5
15.3
9200
40
42
15.7
16.5
9100
43
45
16.9
17.6
9000
46
48
18.0
18.8
8900
49
51
19.2
20.0
8800
52
54
20.4
21.2
8700
55
57
21.6
22.4
DMX Mode 2: Standard
22 DMX Channels
EXO Wash 30 User Manual Rev. B 35
www.glp.de DMX MODE 2
8600
58
60
22.7
23.5
8500
61
63
23.9
24.7
8400
64
66
25.1
25.9
8300
67
69
26.3
27.1
8200
70
72
27.5
28.2
8100
73
75
28.6
29.4
8000
76
78
29.8
30.6
7900
79
81
31.0
31.8
7800
82
84
32.2
32.9
7700
85
87
33.3
34.1
7600
88
90
34.5
35.3
7500
91
93
35.7
36.5
7400
94
96
36.9
37.6
7300
97
99
38.0
38.8
7200
100
102
39.2
40.0
7100
103
105
40.4
41.2
7000
106
108
41.6
42.4
6900
109
111
42.7
43.5
6800
112
114
43.9
44.7
6700
115
117
45.1
45.9
6600
118
120
46.3
47.1
6500
121
123
47.5
48.2
6400
124
126
48.6
49.4
6300
127
129
49.8
50.6
6200
130
132
51.0
51.8
6100
133
135
52.2
52.9
6000
136
138
53.3
54.1
5900
139
141
54.5
55.3
5800
142
144
55.7
56.5
5700
145
147
56.9
57.6
5600
148
150
58.0
58.8
5500
151
153
59.2
60.0
5400
154
156
60.4
61.2
5300
157
159
61.6
62.4
5200
160
162
62.7
63.5
5100
163
165
63.9
64.7
5000
166
168
65.1
65.9
4900
169
171
66.3
67.1
4800
172
174
67.5
68.2
4700
175
177
68.6
69.4
4600
178
180
69.8
70.6
4500
181
183
71.0
71.8
4400
184
186
72.2
72.9
4300
187
189
73.3
74.1
4200
190
192
74.5
75.3
4100
193
195
75.7
76.5
4000
196
198
76.9
77.6
3900
199
201
78.0
78.8
3800
202
204
79.2
80.0
3700
205
207
80.4
81.2
3600
208
210
81.6
82.4
3500
211
213
82.7
83.5
3400
214
216
83.9
84.7
3300
217
219
85.1
85.9
3200
220
222
86.3
87.1
3100
223
225
87.5
88.2
3000
226
228
88.6
89.4
2900
229
231
89.8
90.6
36 EXO Wash User Manual Rev. B
German Light Products® DMX MODE 2
2800
232
234
91.0
91.8
2700
235
237
92.2
92.9
2600
238
240
93.3
94.1
2500
241
255
94.5
100
10
Red
Red intensity 0–100%
0
65535
0
100
32767
Fade
11
Red fine
12
Green
Green intensity 0–100%
0
65535
0
100
32767
Fade
13
Green fine
14
Blue
Blue intensity 0–100%
0
65535
0
100
32767
Fade
15
Blue fine
16
White
White intensity 0–100%
0
65535
0
100
32767
Fade
17
White fine
18
Pattern
Static pattern
0
51 0 20.0
0
Snap
Chase animation
52
131
20.4
51.4
Fade animation
132
211
51.8
82.7
Random
212
255
83.1
100
19
Pattern speed
Slow–fast
0
255 0 100
0
Fade
20
Pattern fade
Slow crossfade–snap
0
255 0 100
0
Fade
21
Zoom
Wide–narrow
0
255 0 100
0
Fade
22
Control / Settings
No function
0 9 0.0
3.5
0
Snap
Dimmer curve: Extra-soft (3s hold)
10
15
3.9
5.9
Dimmer curve: Linear (3s hold)
16
21
6.3
8.2
Display mode: Auto (3s hold)
22
27
8.6
10.6
Display mode: On (3s hold)
28
33
11.0
12.9
Display mode: Off (3s hold)
34
39
13.3
15.3
Display orientation: Normal (3s hold)
40
45
15.7
17.6
Display orientation: Inverted (3s hold)
46
51
18.0
20.0
No DMX: Blackout (3s hold)
52
57
20.4
22.4
No DMX: Hold (3s hold)
58
63
22.7
24.7
No DMX: Stand-alone (3s hold)
64
69
25.1
27.1
Fan mode: Regulated (3s hold)
70
75
27.5
29.4
Fan mode: High (3s hold)
76
81
29.8
31.8
Fan mode: Medium (3s hold)
82
87
32.2
34.1
Fan mode: Low (3s hold)
88
93
34.5
36.5
Position feedback: Off (3s hold)
94
99
36.9
38.8
Position feedback: On (3s hold)
100
105
39.2
41.2
No function
106
117
41.6
45.9
Tilt inversion: Off (3s hold)
118
123
46.3
48.2
Tilt inversion: On (3s hold)
124
129
48.6
50.6
Pan inversion: Off (3s hold)
130
135
51.0
52.9
Pan inversion: On (3s hold)
136
141
53.3
55.3
Zoom inversion: Off (3s hold)
142
147
55.7
57.6
Zoom inversion: On (3s hold)
148
153
58.0
60.0
Defog: Off
154
159
60.4
62.4
Defog: On
160
165
62.7
64.7
Defog: Quick
166
171
65.1
67.1
Load Settings Preset1
172
177
67.5
69.4
Load Settings Preset2
178
183
69.8
71.8
Load Settings Preset3
184
189
72.2
74.1
PWM: 600 Hz (5s hold)
190
195
74.5
76.5
PWM: 2200 Hz (5s hold)
196
201
76.9
78.8
PWM: 3000 Hz (5s hold)
202
207
79.2
81.2
PWM: 4800 Hz (5s hold)
208
213
81.6
83.5
PWM: 9600 Hz (5s hold)
214
219
83.9
85.9
PWM: 25 kHz (5s hold)
220
225
86.3
88.2
EXO Wash 30 User Manual Rev. B 37
www.glp.de DMX MODE 2
No function
226
231
88.6
90.6
Return to default settings
232
237
91.0
92.9
Reset Pan/Tilt (3s hold)
238
243
93.3
95.3
Reset Head (3s hold)
244
249
95.7
97.6
Reset All (3s hold)
250
255
98.0
100
38 EXO Wash User Manual Rev. B
German Light Products® DMX control channel layout tables
Channel
Command
DMX
range
Percent
Default
DMX
Fade
1
Pan
Pan left–right
0
65535
0
100
32767
Fade
2
Pan fine
3
Tilt
Tilt up–down
0
65535
0
100
32767
Fade
4
Tilt fine
5
Dimmer
Intensity 0–100%
0
65535
0
100
32767
Fade
6
Dimmer fine
7
Shutter
Shutter closed
0 4 0
1.6
0
Snap
Single flash when change on dimmer channel
5 9 2.0
3.5
Sync ramp up slow–fast
10
39
3.9
15.3
Sync ramp down slow–fast
40
69
15.7
27.1
Sync ramp up-down slow–fast
70
99
27.5
38.8
Sync double flash (slow–fast)
100
129
39.2
50.6
Random strobe pixel (slow–fast)
130
159
51.0
62.4
Random strobe all (slow–fast)
160
199
62.7
78.0
Sync strobe (1 Hz–10 Hz)
200
250
78.4
98.0
Shutter open
251
255
98.4
100
8
Color wheel effect
Off (RGBW)
0 7 0
2.7
0
Snap
Color 01 - Red
8
15
3.1
5.9
Snap
Color 02 - Amber
16
23
6.3
9.0
Snap
Color 03 - Warm Yellow
24
31
9.4
12.2
Snap
Color 04 - Yellow
32
39
12.5
15.3
Snap
Color 05 - Green
40
47
15.7
18.4
Snap
Color 06 - Turquoise
48
55
18.8
21.6
Snap
Color 07 - Cyan
56
63
22.0
24.7
Snap
Color 08 - Blue
64
71
25.1
27.8
Snap
Color 09 - Lavender
72
79
28.2
31.0
Snap
Color 10 - Mauve
80
87
31.4
34.1
Snap
Color 11 - Magenta
88
95
34.5
37.3
Snap
Color 12 - Pink
96
103
37.6
40.4
Snap
Color 13 - White 3200K
104
111
40.8
43.5
Snap
Color 14 - White 5600K
112
119
43.9
46.7
Snap
Color 15 - White 7200K
120
127
47.1
49.8
Snap
Stop
128
128
50.2
50.2
Snap
Rainbow colors crossfade slow > fast
129
223
50.6
87.5
Fade
Random colors crossfade slow > fast
224
255
87.8
100
Fade
9
Color Temperature (Kelvin)
RAW 0 15 0 5.9
Snap
10000
16
18
6.3
7.1
9900
19
21
7.5
8.2
9800
22
24
8.6
9.4
9700
25
27
9.8
10.6
9600
28
30
11.0
11.8
9500
31
33
12.2
12.9
9400
34
36
13.3
14.1
9300
37
39
14.5
15.3
9200
40
42
15.7
16.5
9100
43
45
16.9
17.6
9000
46
48
18.0
18.8
8900
49
51
19.2
20.0
8800
52
54
20.4
21.2
8700
55
57
21.6
22.4
8600
58
60
22.7
23.5
8500
61
63
23.9
24.7
8400
64
66
25.1
25.9
DMX Mode 3: Extended
37 DMX Channels
EXO Wash 30 User Manual Rev. B 39
www.glp.de DMX control channel layout tables
8300
67
69
26.3
27.1
8200
70
72
27.5
28.2
8100
73
75
28.6
29.4
8000
76
78
29.8
30.6
7900
79
81
31.0
31.8
7800
82
84
32.2
32.9
7700
85
87
33.3
34.1
7600
88
90
34.5
35.3
7500
91
93
35.7
36.5
7400
94
96
36.9
37.6
7300
97
99
38.0
38.8
7200
100
102
39.2
40.0
7100
103
105
40.4
41.2
7000
106
108
41.6
42.4
6900
109
111
42.7
43.5
6800
112
114
43.9
44.7
6700
115
117
45.1
45.9
6600
118
120
46.3
47.1
6500
121
123
47.5
48.2
6400
124
126
48.6
49.4
6300
127
129
49.8
50.6
6200
130
132
51.0
51.8
6100
133
135
52.2
52.9
6000
136
138
53.3
54.1
5900
139
141
54.5
55.3
5800
142
144
55.7
56.5
5700
145
147
56.9
57.6
5600
148
150
58.0
58.8
5500
151
153
59.2
60.0
5400
154
156
60.4
61.2
5300
157
159
61.6
62.4
5200
160
162
62.7
63.5
5100
163
165
63.9
64.7
5000
166
168
65.1
65.9
4900
169
171
66.3
67.1
4800
172
174
67.5
68.2
4700
175
177
68.6
69.4
4600
178
180
69.8
70.6
4500
181
183
71.0
71.8
4400
184
186
72.2
72.9
4300
187
189
73.3
74.1
4200
190
192
74.5
75.3
4100
193
195
75.7
76.5
4000
196
198
76.9
77.6
3900
199
201
78.0
78.8
3800
202
204
79.2
80.0
3700
205
207
80.4
81.2
3600
208
210
81.6
82.4
3500
211
213
82.7
83.5
3400
214
216
83.9
84.7
3300
217
219
85.1
85.9
3200
220
222
86.3
87.1
3100
223
225
87.5
88.2
3000
226
228
88.6
89.4
2900
229
231
89.8
90.6
2800
232
234
91.0
91.8
2700
235
237
92.2
92.9
2600
238
240
93.3
94.1
2500
241
255
94.5
100
10
Red
Red intensity 0–100%
0
65535
0
100
32767
Fade
11
Red fine
40 EXO Wash User Manual Rev. B
German Light Products® DMX control channel layout tables
12
Green
Green intensity 0–100%
0
65535
0
100
32767
Fade
13
Green fine
14
Blue
Blue intensity 0–100%
0
65535
0
100
32767
Fade
15
Blue fine
16
White
White intensity 0–100%
0
65535
0
100
32767
Fade
17
White fine
18
Layer 1 DImmer
Layer 1 (background) intensity 0–100%
0
65535
0
100
32767
Fade
19
Layer 1 Dimmer fine
20
Layer 1 Shutter
Layer 1 (background) shutter closed
0 4 0
1.6
0
Snap
Single flash when change on dimmer channel
5 9 2.0
3.5
Sync ramp up slow–fast
10
39
3.9
15.3
Sync ramp down slow–fast
40
69
15.7
27.1
Sync ramp up-down slow–fast
70
99
27.5
38.8
Sync double flash (slow–fast)
100
129
39.2
50.6
Random strobe pixel (slow–fast)
130
159
51.0
62.4
Random strobe all (slow–fast)
160
199
62.7
78.0
Sync strobe (1 Hz–10 Hz)
200
250
78.4
98.0
Shutter open
251
255
98.4
100
21
Layer 2 DImmer
Layer 2 (top layer) intensity 0–100%
0
65535
0
100
32767
Fade
22
Layer 2 Dimmer fine
23
Layer 2 Pattern Shutter
Shutter closed
0 4 0
1.6
0
Snap
Single flash when change on dimmer channel
5 9 2.0
3.5
Sync ramp up slow–fast
10
39
3.9
15.3
Sync ramp down slow–fast
40
69
15.7
27.1
Sync ramp up-down slow–fast
70
99
27.5
38.8
Sync double flash (slow–fast)
100
129
39.2
50.6
Random strobe pixel (slow–fast)
130
159
51.0
62.4
Random strobe all (slow–fast)
160
199
62.7
78.0
Sync strobe (1 Hz–10 Hz)
200
250
78.4
98.0
Shutter open
251
255
98.4
100
24
Layer 2 Pattern color wheel effect
Layer 2 (top layer) pattern off (RGBW)
0 7 0
2.7
0
Snap
Color 01 - Red
8
15
3.1
5.9
Snap
Color 02 - Amber
16
23
6.3
9.0
Snap
Color 03 - Warm Yellow
24
31
9.4
12.2
Snap
Color 04 - Yellow
32
39
12.5
15.3
Snap
Color 05 - Green
40
47
15.7
18.4
Snap
Color 06 - Turquoise
48
55
18.8
21.6
Snap
Color 07 - Cyan
56
63
22.0
24.7
Snap
Color 08 - Blue
64
71
25.1
27.8
Snap
Color 09 - Lavender
72
79
28.2
31.0
Snap
Color 10 - Mauve
80
87
31.4
34.1
Snap
Color 11 - Magenta
88
95
34.5
37.3
Snap
Color 12 - Pink
96
103
37.6
40.4
Snap
Color 13 - White 3200K
104
111
40.8
43.5
Snap
Color 14 - White 5600K
112
119
43.9
46.7
Snap
Color 15 - White 7200K
120
127
47.1
49.8
Snap
Stop
128
128
50.2
50.2
Snap
Rainbow colors crossfade slow > fast
129
223
50.6
87.5
Fade
Random colors crossfade slow > fast
224
255
87.8
100
Fade
25
Layer 2 Pattern Red
Layer 2 (top layer) pattern red intensity 0–100%
0
65535
0
100
32767
Fade
26
Layer 2 Pattern Red fine
27
Layer 2 Pattern Green
Layer 2 (top layer) pattern green intensity 0–100%
0
65535
0
100
32767
Fade
EXO Wash 30 User Manual Rev. B 41
www.glp.de DMX control channel layout tables
28
Layer 2 Pattern Green fine
29
Layer 2 Pattern Blue
Layer 2 (top layer) pattern blue intensity 0–100%
0
65535
0
100
32767
Fade
30
Layer 2 Pattern Blue fine
31
Layer 2 Pattern White
Layer 2 (top layer) pattern white intensity 0–100%
0
65535
0
100
32767
Fade
32
Layer 2 Pattern White fine
33
Layer 2 Pattern
Layer 2 (top layer) static pattern
0
51 0 20.0
0
Snap
Chase animation
52
131
20.4
51.4
Fade animation
132
211
51.8
82.7
Random
212
255
83.1
100
34
Layer 2 Pattern speed
Slow–fast
0
255 0 100
0
Fade
35
Layer 2 Pattern fade
Slow crossfade–snap
0
255 0 100
0
Fade
36
Zoom
Wide–narrow
0
255 0 100
0
Fade
37
Control / Settings
No function
0 9 0.0
3.5
0
Snap
Dimmer curve: Extra-soft (3s hold)
10
15
3.9
5.9
Dimmer curve: Linear (3s hold)
16
21
6.3
8.2
Display mode: Auto (3s hold)
22
27
8.6
10.6
Display mode: On (3s hold)
28
33
11.0
12.9
Display mode: Off (3s hold)
34
39
13.3
15.3
Display orientation: Normal (3s hold)
40
45
15.7
17.6
Display orientation: Inverted (3s hold)
46
51
18.0
20.0
No DMX: Blackout (3s hold)
52
57
20.4
22.4
No DMX: Hold (3s hold)
58
63
22.7
24.7
No DMX: Stand-alone (3s hold)
64
69
25.1
27.1
Fan mode: Regulated (3s hold)
70
75
27.5
29.4
Fan mode: High (3s hold)
76
81
29.8
31.8
Fan mode: Medium (3s hold)
82
87
32.2
34.1
Fan mode: Low (3s hold)
88
93
34.5
36.5
Position feedback: Off (3s hold)
94
99
36.9
38.8
Position feedback: On (3s hold)
100
105
39.2
41.2
No function
106
117
41.6
45.9
Tilt inversion: Off (3s hold)
118
123
46.3
48.2
Tilt inversion: On (3s hold)
124
129
48.6
50.6
Pan inversion: Off (3s hold)
130
135
51.0
52.9
Pan inversion: On (3s hold)
136
141
53.3
55.3
Zoom inversion: Off (3s hold)
142
147
55.7
57.6
Zoom inversion: On (3s hold)
148
153
58.0
60.0
Defog: Off
154
159
60.4
62.4
Defog: On
160
165
62.7
64.7
Defog: Quick
166
171
65.1
67.1
Load Settings Preset1
172
177
67.5
69.4
Load Settings Preset2
178
183
69.8
71.8
Load Settings Preset3
184
189
72.2
74.1
PWM: 600 Hz (5s hold)
190
195
74.5
76.5
PWM: 2200 Hz (5s hold)
196
201
76.9
78.8
PWM: 3000 Hz (5s hold)
202
207
79.2
81.2
PWM: 4800 Hz (5s hold)
208
213
81.6
83.5
PWM: 9600 Hz (5s hold)
214
219
83.9
85.9
PWM: 25 kHz (5s hold)
220
225
86.3
88.2
No function
226
231
88.6
90.6
Return to default settings
232
237
91.0
92.9
Reset Pan/Tilt (3s hold)
238
243
93.3
95.3
42 EXO Wash User Manual Rev. B
German Light Products® DMX control channel layout tables
Reset Head (3s hold)
244
249
95.7
97.6
Reset All (3s hold)
250
255
98.0
100
EXO Wash 30 User Manual Rev. B 43
www.glp.de DMX control channel layout tables
Channel
Command
DMX
range
Percent
Default
DMX
Fade
1
Pan
Pan left–right
0
65535
0
100
32767
Fade
2
Pan fine
3
Tilt
Tilt up–down
0
65535
0
100
32767
Fade
4
Tilt fine
5
Dimmer
Intensity 0–100%
0
65535
0
100
32767
Fade
6
Dimmer fine
7
Shutter
Shutter closed
0 4 0
1.6
0
Snap
Single flash when change on dimmer channel
5 9 2.0
3.5
Sync ramp up slow–fast
10
39
3.9
15.3
Sync ramp down slow–fast
40
69
15.7
27.1
Sync ramp up-down slow–fast
70
99
27.5
38.8
Sync double flash (slow–fast)
100
129
39.2
50.6
Random strobe pixel (slow–fast)
130
159
51.0
62.4
Random strobe all (slow–fast)
160
199
62.7
78.0
Sync strobe (1 Hz–10 Hz)
200
250
78.4
98.0
Shutter open
251
255
98.4
100
8
Color wheel effect
Off (RGBW)
0 7 0
2.7
0
Snap
Color 01 - Red
8
15
3.1
5.9
Snap
Color 02 - Amber
16
23
6.3
9.0
Snap
Color 03 - Warm Yellow
24
31
9.4
12.2
Snap
Color 04 - Yellow
32
39
12.5
15.3
Snap
Color 05 - Green
40
47
15.7
18.4
Snap
Color 06 - Turquoise
48
55
18.8
21.6
Snap
Color 07 - Cyan
56
63
22.0
24.7
Snap
Color 08 - Blue
64
71
25.1
27.8
Snap
Color 09 - Lavender
72
79
28.2
31.0
Snap
Color 10 - Mauve
80
87
31.4
34.1
Snap
Color 11 - Magenta
88
95
34.5
37.3
Snap
Color 12 - Pink
96
103
37.6
40.4
Snap
Color 13 - White 3200K
104
111
40.8
43.5
Snap
Color 14 - White 5600K
112
119
43.9
46.7
Snap
Color 15 - White 7200K
120
127
47.1
49.8
Snap
Stop
128
128
50.2
50.2
Snap
Rainbow colors crossfade slow > fast
129
223
50.6
87.5
Fade
Random colors crossfade slow > fast
224
255
87.8
100
Fade
9
Color Temperature (Kelvin)
RAW 0 15 0 5.9
Snap
10000
16
18
6.3
7.1
9900
19
21
7.5
8.2
9800
22
24
8.6
9.4
9700
25
27
9.8
10.6
9600
28
30
11.0
11.8
9500
31
33
12.2
12.9
9400
34
36
13.3
14.1
9300
37
39
14.5
15.3
9200
40
42
15.7
16.5
9100
43
45
16.9
17.6
9000
46
48
18.0
18.8
8900
49
51
19.2
20.0
8800
52
54
20.4
21.2
8700
55
57
21.6
22.4
8600
58
60
22.7
23.5
8500
61
63
23.9
24.7
8400
64
66
25.1
25.9
DMX Mode 4: Pix
50 DMX Channels
44 EXO Wash User Manual Rev. B
German Light Products® DMX control channel layout tables
8300
67
69
26.3
27.1
8200
70
72
27.5
28.2
8100
73
75
28.6
29.4
8000
76
78
29.8
30.6
7900
79
81
31.0
31.8
7800
82
84
32.2
32.9
7700
85
87
33.3
34.1
7600
88
90
34.5
35.3
7500
91
93
35.7
36.5
7400
94
96
36.9
37.6
7300
97
99
38.0
38.8
7200
100
102
39.2
40.0
7100
103
105
40.4
41.2
7000
106
108
41.6
42.4
6900
109
111
42.7
43.5
6800
112
114
43.9
44.7
6700
115
117
45.1
45.9
6600
118
120
46.3
47.1
6500
121
123
47.5
48.2
6400
124
126
48.6
49.4
6300
127
129
49.8
50.6
6200
130
132
51.0
51.8
6100
133
135
52.2
52.9
6000
136
138
53.3
54.1
5900
139
141
54.5
55.3
5800
142
144
55.7
56.5
5700
145
147
56.9
57.6
5600
148
150
58.0
58.8
5500
151
153
59.2
60.0
5400
154
156
60.4
61.2
5300
157
159
61.6
62.4
5200
160
162
62.7
63.5
5100
163
165
63.9
64.7
5000
166
168
65.1
65.9
4900
169
171
66.3
67.1
4800
172
174
67.5
68.2
4700
175
177
68.6
69.4
4600
178
180
69.8
70.6
4500
181
183
71.0
71.8
4400
184
186
72.2
72.9
4300
187
189
73.3
74.1
4200
190
192
74.5
75.3
4100
193
195
75.7
76.5
4000
196
198
76.9
77.6
3900
199
201
78.0
78.8
3800
202
204
79.2
80.0
3700
205
207
80.4
81.2
3600
208
210
81.6
82.4
3500
211
213
82.7
83.5
3400
214
216
83.9
84.7
3300
217
219
85.1
85.9
3200
220
222
86.3
87.1
3100
223
225
87.5
88.2
3000
226
228
88.6
89.4
2900
229
231
89.8
90.6
2800
232
234
91.0
91.8
2700
235
237
92.2
92.9
2600
238
240
93.3
94.1
2500
241
255
94.5
100
10
Red
Red intensity 0–100%
0
65535
0
100
32767
Fade
11
Red fine
EXO Wash 30 User Manual Rev. B 45
www.glp.de DMX control channel layout tables
12
Green
Green intensity 0–100%
0
65535
0
100
32767
Fade
13
Green fine
14
Blue
Blue intensity 0–100%
0
65535
0
100
32767
Fade
15
Blue fine
16
White
White intensity 0–100%
0
65535
0
100
32767
Fade
17
White fine
18
Pattern
Static pattern
0
51 0 20.0
0
Snap
Chase animation
52
131
20.4
51.4
Fade animation
132
211
51.8
82.7
Random
212
255
83.1
100
19
Pattern speed
Slow–fast
0
255 0 100
0
Fade
20
Pattern fade
Slow crossfade–snap
0
255 0 100
0
Fade
21
Zoom
Wide–narrow
0
255 0 100
0
Fade
22
Control / Settings
No function
0 9 0.0
3.5
0
Snap
Dimmer curve: Extra-soft (3s hold)
10
15
3.9
5.9
Dimmer curve: Linear (3s hold)
16
21
6.3
8.2
Display mode: Auto (3s hold)
22
27
8.6
10.6
Display mode: On (3s hold)
28
33
11.0
12.9
Display mode: Off (3s hold)
34
39
13.3
15.3
Display orientation: Normal (3s hold)
40
45
15.7
17.6
Display orientation: Inverted (3s hold)
46
51
18.0
20.0
No DMX: Blackout (3s hold)
52
57
20.4
22.4
No DMX: Hold (3s hold)
58
63
22.7
24.7
No DMX: Stand-alone (3s hold)
64
69
25.1
27.1
Fan mode: Regulated (3s hold)
70
75
27.5
29.4
Fan mode: High (3s hold)
76
81
29.8
31.8
Fan mode: Medium (3s hold)
82
87
32.2
34.1
Fan mode: Low (3s hold)
88
93
34.5
36.5
Position feedback: Off (3s hold)
94
99
36.9
38.8
Position feedback: On (3s hold)
100
105
39.2
41.2
No function
106
117
41.6
45.9
Tilt inversion: Off (3s hold)
118
123
46.3
48.2
Tilt inversion: On (3s hold)
124
129
48.6
50.6
Pan inversion: Off (3s hold)
130
135
51.0
52.9
Pan inversion: On (3s hold)
136
141
53.3
55.3
Zoom inversion: Off (3s hold)
142
147
55.7
57.6
Zoom inversion: On (3s hold)
148
153
58.0
60.0
Defog: Off
154
159
60.4
62.4
Defog: On
160
165
62.7
64.7
Defog: Quick
166
171
65.1
67.1
Load Settings Preset1
172
177
67.5
69.4
Load Settings Preset2
178
183
69.8
71.8
Load Settings Preset3
184
189
72.2
74.1
PWM: 600 Hz (5s hold)
190
195
74.5
76.5
PWM: 2200 Hz (5s hold)
196
201
76.9
78.8
PWM: 3000 Hz (5s hold)
202
207
79.2
81.2
PWM: 4800 Hz (5s hold)
208
213
81.6
83.5
PWM: 9600 Hz (5s hold)
214
219
83.9
85.9
PWM: 25 kHz (5s hold)
220
225
86.3
88.2
No function
226
231
88.6
90.6
Return to default settings
232
237
91.0
92.9
Reset Pan/Tilt (3s hold)
238
243
93.3
95.3
Reset Head (3s hold)
244
249
95.7
97.6
Reset All (3s hold)
250
255
98.0
100
23
Pixel 1 Red
Intensity 0-100%
0
255 0 100
0
Fade
24
Pixel 1 Green
Intensity 0-100%
0
255 0 100
0
Fade
25
Pixel 1 Blue
Intensity 0-100%
0
255 0 100
0
Fade
46 EXO Wash User Manual Rev. B
German Light Products® DMX control channel layout tables
26
Pixel 1 White
Intensity 0-100%
0
255 0 100
0
Fade
27
Pixel 2 Red
Intensity 0-100%
0
255 0 100
0
Fade
28
Pixel 2 Green
Intensity 0-100%
0
255 0 100
0
Fade
29
Pixel 2 Blue
Intensity 0-100%
0
255 0 100
0
Fade
30
Pixel 2 White
Intensity 0-100%
0
255 0 100
0
Fade
31
Pixel 3 Red
Intensity 0-100%
0
255 0 100
0
Fade
32
Pixel 3 Green
Intensity 0-100%
0
255 0 100
0
Fade
33
Pixel 3 Blue
Intensity 0-100%
0
255 0 100
0
Fade
34
Pixel 3 White
Intensity 0-100%
0
255 0 100
0
Fade
35
Pixel 4 Red
Intensity 0-100%
0
255 0 100
0
Fade
36
Pixel 4 Green
Intensity 0-100%
0
255 0 100
0
Fade
37
Pixel 4 Blue
Intensity 0-100%
0
255 0 100
0
Fade
38
Pixel 4 White
Intensity 0-100%
0
255 0 100
0
Fade
39
Pixel 5 Red
Intensity 0-100%
0
255 0 100
0
Fade
40
Pixel 5 Green
Intensity 0-100%
0
255 0 100
0
Fade
41
Pixel 5 Blue
Intensity 0-100%
0
255 0 100
0
Fade
42
Pixel 5 White
Intensity 0-100%
0
255 0 100
0
Fade
43
Pixel 6 Red
Intensity 0-100%
0
255 0 100
0
Fade
44
Pixel 6 Green
Intensity 0-100%
0
255 0 100
0
Fade
45
Pixel 6 Blue
Intensity 0-100%
0
255 0 100
0
Fade
46
Pixel 6 White
Intensity 0-100%
0
255 0 100
0
Fade
47
Pixel 7 Red
Intensity 0-100%
0
255 0 100
0
Fade
48
Pixel 7 Green
Intensity 0-100%
0
255 0 100
0
Fade
49
Pixel 7 Blue
Intensity 0-100%
0
255 0 100
0
Fade
50
Pixel 7 White
Intensity 0-100%
0
255 0 100
0
Fade
EXO Wash 30 User Manual Rev. B 47
www.glp.de Service
Warning! There are no user-serviceable parts inside the fixture. Opening the fixture can compromise its IP65 rating and cause damage that is not covered by the product warranty. Any service operation that requires removal of a cover must be performed by a professional service technician with the tools, skills, and personal protective equipment to maintain high-powered lighting equipment safely and efficiently.
13. Service
Cleaning
EXO Wash 30 fixtures require occasional cleaning to prevent the buildup of dust, dirt, and residue from atmospheric effects. Failure to keep the fixture clean will significantly reduce light output and may cause heat buildup and damage that is not covered by the product warranty. Regular cleaning will ensure maximum performance and reliable operation.
The cleaning schedule depends on the operating environment. Check fixtures regularly for signs of dirt buildup.
You can clean the fixture using a soft cloth slightly dampened with a household or automotive glass cleaning product. Do not apply pressure to the clear front or display on the back of the fixture, as you may scratch these surfaces.
Use the tilt lock mechanism to hold the head in a vertical position for easier cleaning.
GLP Service and Support
Contact information for the nearest GLP Service and Support is available online at www.glp.de/en/service, by email at info@glp.de, or by telephone at the following numbers:
GLP Germany: +49 (7248) 927 19-55
GLP N. America: +1 818 767-8899
GLP UK: +44 1392 690140
GLP Asia: +852 (3151) 7730
GLP Nordic: +46 737 57 11 40
48 EXO Wash User Manual Rev. B
German Light Products® Technical specifications
14. Technical specifications
Optics
Light source: 7x 40W Osram RGBW LEDs Lifetime: 20 000 hrs. approx. to > 70% luminous output Luminous flux: 40995 lux @ 3 m, 14758 lux @ 5 m Beam angle (half peak): 4° to 54°
Control
Control systems: DMX, RDM, Manual setting DMX channel footprint: 13 / 22 / 37 / 50 depending on mode Setting and addressing: Onboard control panel with LCD display, RDM DMX compliance: USITT DMX512 RDM compliance: ANSI/ESTA E1.20 Pan range: 630°, 16 bit resolution Tilt range: 267°, 16 bit resolution
Installation
Options: Stand on horizontal surface, suspended using truss mount brackets Operating position: Any Minimum distance to combustible materials: 0.5 m (20 in.) Minimum distance to illuminated surfaces: 0.5 m (20 in.) Installation environment: Temporary or permanent indoor installation, temporary outdoor
installation Secondary attachment: Slot for safety cable attachment
Electrical
AC mains power: 100-240 V nominal, 50/60 Hz Power supply unit: Auto-ranging electronic switch mode Maximum power consumption, all LEDs at 100% output: 300 W
Maximum permitted number of fixtures daisy-chained to power
4 x EXO Wash 30 total @ 100-120 V, 60 Hz 8 x EXO Wash 30 total @ 200-240 V, 50 Hz
Connections
AC mains power in and thru (out): Neutrik powerCON TRUE1 with sealing cap Control data in and thru (out): Neutrik 5-pin XLR with sealing cap
Construction
Ingress protection rating: IP65 Fixture housing: Aluminum, plastic Color: Black
Thermal
Cooling: Fan, Convection Minimum ambient temperature: -10° C (14° F) Maximum ambient temperature: 40° C (104° F)
EXO Wash 30 User Manual Rev. B 49
www.glp.de Technical specifications
Included items
Power cable with Neutrik powerCON TRUE1 mains input plug
Dimensions and weight
Length: 279mm / 11.0 ins. Width: 380 mm / 15.0 ins. Height: 521 mm / 20.5 ins. Weight: 19.7 kg (43.4 lbs.)