The marks ‘GLP’ and ‘German Light Products’ are trademarks registered as the property of German
Light Products GmbH in Germany, in the United States of America and in other countries.
The information contained in this document is subject to change without notice. German Light
Products GmbH and all affiliated companies disclaim liability for any injury, damage, direct or
indirect loss, consequential or economic loss or any other loss occasioned by the use of, inability to
use or reliance on the information contained in this document.
Manufacturer’s head office:
German Light Products GmbH (GLP), Industriestrasse 2, 76307 Karlsbad, Germany
Tel (Germany): +49 7248 92719 - 0
Service & Support EMEA:
GLP, Industriestrasse 2, 76307 Karlsbad, Germany
Tel. (Germany): +49 7248 9271955
Email: support@glp.de
www.glp.de
Service & Support USA:
GLP USA, 1145 Arroyo St., Ste. A, 91340 San Fernando, California
Tel (USA): +1 818 767 8899
Support (US): info@germanlightproducts.com
www.germanlightproducts.com
Warning! Safety hazard.
Risk of severe injury or
death.
Warning! Hazardous voltage.
Risk of lethal or severe
electric shock.
Warning! See user
manual for important
safety information.
Warning! Fire hazard.
Warning! Risk of eye
injury.
1. Safety
Key to symbols
The following symbols are used in the Fusion EXO Spot 30 lighting fixture’s user
documentation:
General safety information
Read this manual carefully before installing, using or servicing the Fusion EXO Spot 30
lighting fixture.
If you have any doubts or questions about how to use the fixture safely, contact your
GLP® supplier for assistance. Your GLP supplier will be happy to help.
The user documentation for GLP Fusion EXO Spot 30 lighting fixtures consists of:
● This document, the EXO Spot 30 User Manual, supplied with the fixture and available
for download from www.glp.de. The User Manual contains important safety
information and installation instructions that the installer and user must read.
● The EXO Spot 30 DMX Channel Index, available for download from www.glp.de. The
Channel Index is a separate guide to the DMX control channel layout and DMX
commands available.
All documents are available for download from www.glp.de.
The Fusion EXO Spot 30 is intended for use by experienced professionals with the
knowledge and skills to set up, operate, and maintain high-powered, remotely
controlled lighting equipment safely and efficiently. These operations require expertise
that may not be provided in this Manual or in the User Manual.
● Respect all warnings and directions given in the fixture’s user documentation and
on the fixture. Read the user documentation and familiarize yourself with the safety
precautions it contains before installing or using the fixture. GLP and affiliated
EXO Spot 30 User Manual Rev. A 5
www.glp.de Safety
companies will take no responsibility for damage or injury resulting from disregard for
the information in the user documentation.
● Check the GLP website at www.glp.de and make sure that you have the latest
version of this manual. Check the fixture software version indicated on page 2 of this
manual and then use the fixture’s control panel to check the version installed in the
fixture. If the versions are not the same, this manual may still cover the fixture,
because software updates do not always affect the way you use the fixture.
However, it is possible that this manual does not match the fixture perfectly.
Software release notes can help clarify this question. You can consult software
release notes and download the correct version of this manual on the GLP website if
necessary.
● Make all user documentation available to all installers and operators. Save this
document for future reference.
● If you have any questions about the safe operation of the fixture, please contact an
authorized GLP distributor (see list of distributors at www.glp.de).
● Use the fixture only as directed in this manual. Observe all markings in this manual
and on the fixture.
● Refer all repairs and any service operation not described in this manual to a
technician authorized by GLP.
● The light source in this fixture must not be changed by the end user.
● Read and follow the user documentation for all additional equipment.
Electrical safety
● Do not allow the fixture to become immersed. Do not expose the fixture to highpressure water projections.
● Keep any unused connectors on the fixture sealed with their protective caps at all
times, both when the fixture is in use and when not in use.
● Use only a source of AC mains power that complies with local building and
electrical codes and has both overload and ground fault (earth fault) protection.
● Ensure that the fixture is electrically connected to ground (earth).
● Disconnect the fixture from AC mains power before carrying out any installation or
maintenance work and when the fixture is not in use.
● Disconnect the fixture from power immediately if any seal, cover, cable, connector
or other component is damaged, defective, deformed or showing signs of
overheating. Do not reapply power until the fixture has been repaired and made
safe by a technician authorized by GLP.
● Check that all power distribution equipment, cables and connectors are in perfect
condition, rated for the electrical requirements of all connected devices, suitable
for their application and suitable for the installation environment.
6 EXO Spot 30 User Manual Rev. A
German Light Products® Safety
● Use only Neutrik PowerCON TRUE1 cable connectors for AC mains power input at
the fixture’s Mains IN connector and for relaying AC mains power from one fixture’s
Mains OUT (Thru) connector to another fixture’s Mains IN connector.
● Use minimum 14 AWG or 1.5 mm2 power input and relay cables that are minimum
16 A-rated and temperature-rated to suit the application. In the USA and Canada
the cables must be UL-listed, type SJT or equivalent. In the EU the cables must be
type H05VV-F or equivalent.
● Do not connect devices to power in a chain if the total maximum current draw of all
the devices in the chain when added together will exceed the current rating of any
cable or connector used at any point in the chain. The supplied power input cable
is rated as follows:
- US power cable: 16 A, 14 AWG, UL-listed, E304117, SJT, 4.9 ft.
- EU power cable: 16 A, 1.5 mm², H07RN-F, 1.5 m.
Do not connect more than six (6) Fusion EXO Spot 30 fixtures to power in a chain at
100-120 V, 60 Hz.
Do not connect more than twelve (12) Fusion EXO Spot 30 fixtures to power in a
chain at 200-240 V, 50 Hz.
● The voltage and frequency at the Mains OUT socket are the same as the voltage
and frequency applied to the Mains IN socket. Only connect devices to the Mains
Out socket that accept this voltage and frequency.
● Fusion EXO Spot 30 fixtures do not have a user-replaceable fuse. If you suspect that
a fuse has blown, disconnect the fixture from power and send it to a technician
authorized by GLP for repair.
Fire safety and protection from burns
● Do not operate the fixture if the ambient temperature (Ta) exceeds 40° C / 104° F.
● The surface of the fixture’s casing can reach up to 90° C / 194° F during operation.
Avoid contact by persons and materials. Do not install the fixture in a location where
there is a risk of accidental contact. Allow the fixture to cool for at least 20 minutes
before handling
● Keep the fixture well away from flammable materials.
● Keep all combustible materials (e.g. fabric, wood, paper) at least 0.5 m / 20 in.
away from the fixture.
● Ensure that there is free and unobstructed airflow around the fixture.
● Do not illuminate surfaces within 0.5 m / 20 in. of the fixture. The light output from the
fixture is powerful enough to cause burns or fire in illuminated objects at very close
range.
● Do not stick filters, masks or other materials onto the fixture. Do not block the light
output in any way. The front surface becomes hot during operation and can melt or
EXO Spot 30 User Manual Rev. A 7
www.glp.de Safety
ignite objects that are in contact with the surface. Ensure that the front surface Is
clean and unobstructed at all times in order to prevent a fire hazard and damage
to the fixture.
● The fixture’s optical components can focus the sun’s rays, creating a risk of fire and
damage. Do not expose the front of the fixture to sunlight or any other intense light
source, even from an angle.
Eye safety
● The EXO Spot 30 is classified as a Risk Group 3 lighting fixture according to EN 62471.
Possibly hazardous radiation emitted. Do not stare into the light output from the
fixture. May be harmful to the eyes.
● Do not look at the fixture’s light output with optical instruments or any device that
may concentrate the light output.
● Make sure that persons near to or working on the fixture are not looking directly into
the light output when the fixture lights up suddenly. This can happen when power is
applied, when the fixture receives a DMX signal, or when certain control menu items
are selected.
● The warning below is printed on the fixture. If the warning becomes impossible to
read, replace it with a label reproduced from this illustration:
● Provide well-lit conditions to reduce the pupil diameter of anyone working on or
near the fixture.
Strobe safety
● Flashing light, particularly at 5 - 30 Hz, may cause seizures in persons with
photosensitive epilepsy. Do not use strobe effects for extended periods.
● Comply with local regulations on the use of strobe lighting and notify the public in
advance with highly visible warning signs when strobe effects are used.
● If a seizure occurs, stop using strobe effects. Seek professional medical help. Note
the time that the seizure starts and finishes. Call emergency medical help urgently if
8 EXO Spot 30 User Manual Rev. A
German Light Products® Safety
the seizure lasts more than five minutes, if it is the person’s first seizure, or if the person
is injured. While waiting for help to arrive, protect the affected person from injuring
themselves on hard or sharp objects. If necessary, move the person to a safe place.
Lay them on their side with their head supported to prevent it from hitting the floor.
Loosen any tight clothing around their neck. Do not use force to hold the person or
restrict their movements. Do not put anything in their mouth, including your fingers.
Installation safety and protection from personal injury
● Installation must be performed by qualified personnel only and carried out in
accordance with all locally applicable regulations such as DIN VDE 0711-217.
● The fixture is not portable when installed.
● Ensure that the supporting structure and installation hardware used can hold at least
ten times the weight of the load that they support.
● Fasten the fixture to a structure or surface only as directed in this manual and only
with hardware that is specifically designed and rated for its purpose. Do not use a
safety cable as the primary means of support. Check that installation hardware is in
perfect condition. Fasteners must be steel grade 8.8 strength or better. Rigging
clamps must be half-coupler type that completely encircle the rigging truss chord.
● If the fixture is installed in a location where it may cause injury or damage if it falls,
install as directed in this manual a safety cable or similar secondary attachment that
will hold the fixture if a primary attachment fails. The secondary attachment must be
approved by an official body such as TÜV as a safety attachment for the weight
that it secures, it must comply with EN 60598-2-17 Section 17.6.6, and it must be able
to support a static suspended load that is ten times the weight that it secures.
● If the fixture is installed in a location where it may be exposed to forces such as wind
pressure, vibration or movement, make sure that the installation can withstand these
forces. Monitor weather forecasts constantly. Take down the installation
immediately if there is any risk of weather conditions that could destabilize the
installation.
● Check that all covers and items of rigging hardware are secure before using the
fixture. Do not operate the fixture with missing or damaged covers, shields or any
optical component.
● Restrict access below the work area and work from a stable platform whenever
installing, servicing or moving the fixture.
● If the fixture becomes damaged, stop using it immediately and disconnect it from
power. Do not attempt to use a fixture that is obviously damaged.
● Do not modify the fixture in any way not described in its user documentation.
● Install genuine GLP parts only.
EXO Spot 30 User Manual Rev. A 9
www.glp.de Avoiding damage to the fixture
2. Avoiding damage to the fixture
Important! Follow the directions in this section carefully, or the fixture may suffer
damage that is not covered by the product warranty.
General precautions
Do not drop the fixture or expose it to mechanical stress.
Protect the onboard LCD display and control panel from shocks, or they may suffer
damage that is not covered by the product warranty.
Do not expose the fixture to heat (from other lighting fixtures for example).
Clean optical components only as directed. Oils, solvents, and other chemicals
commonly used for cleaning can damage the lens coatings and surfaces.
Use only original spare parts. Do not make any structural modifications to the fixture or
you will void the product warranty.
Avoiding damage from light sources and heat
Do not point the front of the fixture towards the sun or other strong light sources. Strong
light can cause internal damage to the fixture, melting components or starting an
internal fire within seconds.
Figure 1. Avoiding damage from light sources
Damage can occur whether the fixture is powered on or off. See Figure 1. Damage
can also occur if the light hits the front of the fixture at an angle: the fixture does not
need to be pointing directly at the sun or other light source.
To avoid problems from strong light sources:
● Do not expose the front of the fixture to sunlight or any other strong light source.
● In outdoor applications during daylight, make sure that the front face of the fixture is
shielded or points away from the sun, even when not in use.
● Do not aim other high-powered beam lights directly at the fixture.
Do not operate the fixture in ambient temperatures above 40° C / 104° F. Allow free
airflow around the fixture.
10 EXO Spot 30 User Manual Rev. A
German Light Products® Avoiding damage to the fixture
IP rating
EXO Spot 30 fixtures are IP65-rated:
● IP stands for Ingress (entry into the fixture) Protection.
● The first figure 6 in the rating means that fixtures are protected against the entry of
dust and airborne particles.
● The second figure 5 in the rating means that fixtures are protected against the entry
of rain and water projections from all angles. Fixtures are not protected against
immersion in water and they are not protected against high-pressure water jets.
Avoiding damage from water and humidity
● Do not install EXO Spot 30 fixtures in a location where water can pool around the
fixture or allow EXO Spot 30 fixtures to become submerged in any other way. Do not
aim low- or high-pressure water jets at fixtures.
● Keep all unused connectors on the fixture sealed with their protective caps, both
when the fixture is being used and when it is not in use.
● In outdoor and high-humidity environments, use IP65-rated power and data
connectors and cable (an IP65 rating means that the item is protected against the
entry of water from rain, projections and low-pressure jets as well as the entry of
dust). When assembling connectors and installing them on cable, follow the
manufacturer’s instructions (see www.neutrik.com) and ensure that an IP65 rating is
maintained for the complete assembly. Use only the following cable connectors:
- IP65-rated 5-pin XLR connectors for data IN and OUT (THRU)
- Neutrik powerCON TRUE1 NAC3FX-W for Power IN
- Neutrik powerCON TRUE1 NAC3MX-W for Power OUT (THRU).
● Apply a dielectric grease (available from electrical suppliers) to connector terminals
and caps to prevent corrosion and/or electrical short circuits.
● Make sure that cables open into dry areas or sealed junction boxes. Moisture can
be drawn along cables by capillary action or pressure variations resulting from
thermal expansion.
● See drawing on right.
Arrange cables so that they
arrive at connectors from
below. Make sure that it is
impossible for water to flow
down cables and
accumulate at connectors.
If necessary, provide extra
cable slack and create ‘drip loops’ before connectors.
● Create loose cable bends only. Do not subject connections to bending forces or
allow connections to bear the weight of long lengths of cable.
EXO Spot 30 User Manual Rev. A 11
www.glp.de Avoiding damage to the fixture
Avoiding damage from dust and airborne particles
● Carry out regular visual inspections of the fixture to make sure that there is no
accumulation of dirt, especially on the front of the fixture.
● If cleaning is necessary, follow the instructions in ‘Service’ on page 38.
Transportation and storage
● Transport the fixture in its original packaging or a suitably designed flight case to
protect it from damage caused by shocks during transportation.
● Release the tilt lock and support the fixture’s head with the original packaging
inserts or flight case inserts during transportation.
● Store the fixture in a dry location when not in use.
GLP Service and Support
Contact information for the nearest GLP Service and Support is available online at
www.glp.de/en/service, by email at info@glp.de, or by telephone at the following
numbers:
● GLP Germany: +49 (7248) 927 19-55
● GLP N. America: +1 818 767-8899
● GLP UK: +44 1392 690140
● GLP Asia: +852 (3151) 7730
● GLP Nordic: +46 737 57 11 40
12 EXO Spot 30 User Manual Rev. A
German Light Products® EXO Spot 30 overview
3. EXO Spot 30 overview
The Fusion EXO Spot 30 from GLP is a powerful LED-based profile spot fixture with fast
pan and tilt, CMY color mixing, six fixed colors on three separate wheels, and six
rotating / eight fixed gobos on two wheels. A rotating prism, variable frost, variable
beam angle (zoom) are also provided.
The fixture can be controlled by DMX or by settings on its built in color LCD control
panel. An optional wireless DMX module can be fitted to enable LumenRadio wireless
control. The fixture has a built-in battery to allow the display to be operated for setup
before mains power is connected.
The EXO Spot 30 can be used indoors in permanent and temporary installations. Its
rugged construction and IP65 rating mean that it can also be used outdoors in
temporary installations if precautions are taken to prevent immersion in water and
damage from direct sunlight. It can stand on a horizontal surface or be suspended
from a suitable structure as described in Section 4.
The EXO Spot 30 is not suitable for household use, for use in any location where
unattended children have access to it, or for use in permanent outdoor installations.
EXO Spot 30 User Manual Rev. A 13
www.glp.de EXO Spot 30 overview
8 – Wireless indicator
9 – Battery button
10 – PowerCON TRUE1 input
11 – Mode / Esc button
12 – Up button
13 – Down button
14 – Enter button
15 – Optional wireless antenna
16 – 5 pin XLR DMX input
17 – 5 pin XLR DMX link out
18 – Vent valve
19 – PowerCON TRUE1 link out
1 – Output lens
2 – Head
3 – Tilt lock
4 – Yoke
5 – Control panel
6 – Base
7 – Rubber feet
Figure 2. EXO Spot 30 overview
14 EXO Spot 30 User Manual Rev. A
German Light Products® Installation
4. Installation
Warning! Read ‘Safety’ starting on page 5 for important safety information
that you must understand before you install or operate the fixture. Install
EXO Spot 30 fixtures only as described in this chapter, or you may create an
installation that is unsafe.
Install the fixture at least 0.5 m / 20 in. away from combustible materials
(wood, textiles, paper, etc.), 0.5 m / 20 in. away from any surface that will
be illuminated, and a safe distance away from any flammable materials
(volatile spirits, etc.).
It is the installer’s responsibility to provide a stable, secure supporting
structure that is suitable for the environment and application and that
meets all applicable codes and legal requirements. Note the requirement
to secure lighting fixtures with safety cables in temporary installations.
Permitted mounting options
An EXO Spot 30 fixture may be installed in one of the following ways:
1. Fastened to a rigging truss or similar structure at any angle by means of
truss couplers or other clamps fixed to the two Omega brackets which attach
to the half-turn couplers on the underside of the base.
2. Standing upright on the base on a horizontal surface.
Securing fixtures with a safety cable
In temporary installations, if a fixture can cause injury or damage if it falls you must
secure it with a secondary attachment such as a safety cable that will hold it if the
primary means of attachment fails. The safety cable must be approved for the weight
that it secures. In multiple installations, each fixture must have its own safety cable.
EXO Spot 30 User Manual Rev. A 15
www.glp.de Installation
To secure an EXO Spot 30 fixture with a safety cable:
Figure 3. Safety cable attachment
1. Loop a safety cable around a secure anchoring point such as a truss
beam or fixed structure so that it will catch the fixture if a rigging clamp fails.
Take up as much slack as possible in the safety cable (by looping it more than
once around the bar, for example).
2. See Figure 3 and Figure 4. Fasten the safety cable through the slot “B” on
the underside of the fixture base. Check that the fixture is now secured.
Installing on a rigging truss or similar structure
You can suspend an EXO Spot 30 fixture from a rigging truss or pipe using suitable
clamps attached to the Omega Brackets supplied with the EXO Spot 30.
If you are going to install the fixture hanging vertically downwards from a horizontal
rigging truss or pipe, you can fasten it to the truss using G-clamps. If you are going to
install the fixture in any other orientation, you must use half-coupler clamps that
completely surround the truss chord or pipe.
16 EXO Spot 30 User Manual Rev. A
German Light Products® Installation
Figure 4. Omega bracket fasteners
1. Attach suitable clamps to the Omega brackets.
2. Line up the fasteners of the Omega bracket with the holes “A” in the
base of the EXO Spot 30 as shown in Figure 4. The brackets may be installed
either way round so the cabling is in line with the bar or at right angles to it.
3. Lock the Omega brackets onto the EXO Spot 30 by turning the fasteners
through 90 degrees.
4. Attach the clamp to the truss or structure. Ensure that the head and yoke
of the fixture will not collide with any fixed objects as the fixture moves. Ensure
that the fixture has sufficient clearance to any adjacent surfaces or objects.
5. Secure the fixture with a safety cable through slots “B” as described in the
previous section.
Standing on a horizontal surface
To install an EXO Spot 30 fixture on a horizontal surface:
1. Check that the surface is secure and can safely hold the weight of the
fixture plus all hardware and cables.
2. Stand the fixture firmly on the rubber feet fitted to the base of the unit.
Ensure that the head and yoke of the fixture will not collide with any fixed
objects as the fixture moves. Ensure that the fixture has sufficient clearance to
any adjacent surfaces or objects.
EXO Spot 30 User Manual Rev. A 17
www.glp.de AC mains power
5. AC mains power
Warning! Read ‘Safety’ starting on page 5 for important safety information
that you must understand before you install or operate the fixture.
Check that all cables and connectors are suitable for the installation
environment and application (see recommendations in ‘Avoiding damage
to the fixture’ on page 10).
Use H07 RN-F 3 x 2.5mm / SJT 12 AWG cables with original Neutrik powerCON
TRUE1 connectors to supply power to fixtures.
Line up the keyways in connectors carefully. Do not try to insert or twist a
connector if it feels excessively stiff. Resistance to insertion or twisting is a sign
that connectors may be incorrectly lined up.
Keep connectors sealed with their rubber caps at all times when not in use.
Included items
The EXO Spot 30 is supplied with a power cord with Neutrik powerCON TRUE1
connector.
Connecting to power
The AC mains power supply must include a connection to ground / protective earth. It
must be protected against ground / earth leakage and overload. The fixture’s internal
auto-sensing power supply accepts AC power at 100-240 V, 50/60 Hz. Do not connect
the fixture to power at any other voltage or to an external dimmer.
The EXO Spot 30 does not have a power ON/OFF switch. Power is applied to the fixture
as soon as the power cable becomes live.
The EXO Spot 30 has a 3-conductor Neutrik powerCON TRUE1 Mains IN power input
socket that accepts AC power from a TRUE1 female cable connector. Although TRUE1
connectors support hot plugging, it is still good practice to shut down power to power
cables before connecting them to fixtures.
To connect the fixture to power:
1. If convenient, shut down power to the power input cable.
2. Note the position of the keys and keyways on the TRUE1 power cable
connector and Mains IN socket and align them with each other. Insert the
cable connector into the socket and twist clockwise to lock. Do not use force.
If the connector feels excessively stiff, remove it and check again that it is
lined up correctly.
3. Before applying power to the power cable, check that nobody is looking
directly into the front of the fixture.
To disconnect the fixture from power, pull the latch on the cable connector outwards
to release it, then twist the connector counterclockwise and pull to remove it from the
socket.
18 EXO Spot 30 User Manual Rev. A
German Light Products® AC mains power
Live or L
Neutral or N
Ground / Earth or
US system
Black
White
Green
EU system
Brown
Blue
Yellow/green
Installing power connectors
If you intend to draw power from convenience receptacles / consumer mains power
sockets, it is possible to install a suitable cord cap / power plug on the supplied power
cord / input cable. If you do this, check that the cord cap / plug is rated minimum
250 V, 16 A, that it has a connection to ground / earth and that it has an integral cable
grip. Follow the cord cap / plug manufacturer’s assembly instructions.
If you need to install a Neutrik powerCON TRUE1 connector on a power cable, follow
the instructions given in the Support area of the Neutrik website at www.neutrik.com.
Respect the color coding used in the supplied power cable and in your local mains
power wiring system. US and EU systems use the color coding shown below:
Connecting multiple fixtures to power in a chain
You can connect fixtures to power in a daisy-chain to simplify your power circuit
layout.
EXO Spot 30 fixtures have 2.5 mm2 internal wiring from Power IN to Power THRU
connectors.
Warning! Do not connect more than six (6) EXO Spot 30 fixtures in total to
power in one chain at 100-120 V, 60 Hz. Do not connect more than twelve
(12) EXO Spot 30 fixtures in total to power in one chain at 200-240 V, 50 Hz.
The power input cable supplied with the fixture is rated 16 A maximum. Add
together the maximum current draw ratings of all the devices that you
intend to connect to power in a daisy chain and do not create a chain with
a total maximum current draw of more than 16 A, or you will create a risk of
fire and electric shock.
To connect fixtures to power in a chain:
1. Obtain power relay cables that have male and female Neutrik
powerCON TRUE1 connectors. Cables must be minimum 14 AWG or 1.5mm2,
rated minimum 16 A and suitable for the environment and application.
EXO Spot 30 User Manual Rev. A 19
2. Connect the power input cable to the Mains IN socket of the first fixture
as described under ‘Connecting to power’ on page 18.
3. Connect a relay cable to the Mains OUT / THRU socket of the first fixture
and to the Mains IN socket of the second fixture.
4. If you are using 100-120 V, 60 Hz AC mains power you can continue
linking EXO Beam fixtures Mains OUT / THRU socket to Mains IN socket until the
chain contains a maximum of six (6) fixtures in total. If you are using 200-240 V,
50 Hz AC mains power you can continue connecting fixtures Mains OUT to
Mains IN until the chain contains a maximum of twelve (12) fixtures total.
www.glp.de Connecting to DMX data
1
Signal Ground
2
Data –
3
Data +
4
Not used
5
Not used
6. Connecting to DMX data
Check that all cables and connectors are suitable for the installation environment and
application (see recommendations in ‘Avoiding damage to the fixture’ on page 10).
Use digital 110 Ohm DMX cable with IP65 5-pin XLR connectors to supply DMX data to
fixtures.
Keep connectors sealed with their rubber caps at all times when not in use.
The EXO Spot 30 has two 5-pin XLR sockets for IN and THRU connections to a DMX data
link.EXO Spot 30 fixtures support the USITT DMX 512A signal protocol. They also support
RDM (Remote Device Management).
The 5-pin XLR connectors use standard pin allocations:
The DMX cable should start at the console and be daisy-chained through each fixture
to be controlled using the DMX input and DMX link out connectors. If you need to split
the DMX cable, use a powered DMX splitter.
If you would like advice with planning and installing a DMX link, your GLP supplier will
be happy to provide assistance.
20 EXO Spot 30 User Manual Rev. A
German Light Products® Starting and stopping operation
7. Starting and stopping operation
Warning! Before you apply power to the fixture or operate it after a
blackout, make sure that nobody is looking directly into the front of the
fixture.
The EXO Spot 30’s TRUE1 mains power input connector supports hot-plugging, and
connecting and disconnecting a live power cable is an option, especially if you need
to shut down power urgently, but it is still good practice to shut down power to the AC
mains power circuit before connecting and disconnecting power cables.
To start operation, check that nobody is looking into the front of the fixture, then apply
power to the AC mains power circuit.
To stop operation, shut down power to the AC mains power circuit.
EXO Spot 30 User Manual Rev. A 21
www.glp.de Features
8. Features
The EXO Spot 30 unit has the following features:
Position
Pan rotation 540°, Tilt rotation 258° with 16 bit resolution. The fixture will automatically
reposition if knocked – this option can be disabled from the menu. The Pan and Tilt
movements can be inverted using the menu.
Color wheels
Color can be controlled either by variable Cyan, Magenta, Yellow control channels (8-
10), or fixed color filters can be selected using Color 1/Cyan, Color 2/Magenta, Color
3/Yellow control channels (5-7).
To set a fixed color you must have the corresponding variable color channel set to zero
● to set Color 1 on channel 5 you must set Cyan on channel 8 to zero,
● to set Color 2 on channel 6 you must set Magenta on channel 9 to zero,
● to set Color 3 on channel 7 you must set Yellow on channel 10 to zero,
Internally the fixture has three color wheels each with 4 colors including open white
and a variable Cyan, Magenta or Yellow segment.
Figure 5. Color Wheels
22 EXO Spot 30 User Manual Rev. A
German Light Products® Features
Gobo wheels
The EXO Spot 30 has two gobo wheels. Wheel 1 has 9 positions including open and the
gobos are fixed (non-rotating).
Figure 6. Gobo Wheel 1
Wheel 2 has seven positions including open and these gobos are rotatable and
indexable.
Figure 7. Gobo Wheel 2
EXO Spot 30 User Manual Rev. A 23
www.glp.de Features
Dimming
16-bit dimming control is provided. You can select from two dimming curves using the
control panel or the Control / Settings DMX channel, see Figure 8:
Figure 8. Dimming curves
● Linear sets dimming so that it appears to increase and decrease evenly throughout
the dimming range.
● Soft gives finer control at low light levels and coarser control at high light levels.
The default setting is Soft.
Strobe / shutter
A variety of strobing and fading effects can be produced by the fixture.
Prism
A three segment prism allows beam splitting effects. The prism can be independently
inserted in the beam path or removed, and can be continuously rotated in either
direction or set to an indexed position.
Frost
A variable amount of frost / diffusion can be added to the light beam
Focus
Variable focus allows you to focus the output on Gobo wheel 1, Gobo wheel 2 or
create gobo morph effects by moving focus between two gobos.
Zoom
The beam size can be controlled between 7 degrees and 30 degrees. A menu option
allows you to reverse the operation of the zoom control.
24 EXO Spot 30 User Manual Rev. A
German Light Products® Features
Behavior when the fixture is not receiving a DMX signal
You can set the fixture to react in three different ways if no DMX signal is present (if the
fixture is being controlled by DMX but the DMX signal stops, or if you apply power to
the fixture when no DMX signal is present):
● Blackout sets the fixture to black out. This is the default setting.
● Hold sets the fixture to continue obeying the last DMX values it received. If no DMX
signal was being received, the fixture will black out.
● Preset Scene sets the fixture to output a preset scene which you have previously
captured from an incoming DMX state using the Manual Control > Capture Scene
menu option. You can also manually set the control values (or edit the captured
values) using the attribute settings in the Manual Control menu.
All these settings are available via DMX on the Control / Settings channel and in the
fixture’s control panel.
EXO Spot 30 User Manual Rev. A 25
www.glp.de Control menus and onboard display
9. Control menus and onboard display
Warning! DMX control is disabled when the control menus are active. Be
prepared for the fixture to emit strong light as soon as you exit the control
menus.
The control panel and onboard LCD display provide access to user settings, readouts
and utilities.
Figure 9. Onboard display
The four control buttons have the following functions:
MODE/ESC: Activate the menus or go back one level towards the top of the
menu.
UP: Scroll up or increase a number.
DOWN: Scroll down or reduce a number.
ENTER: Activate the control panel if it is in sleep mode. Then enter a menu, select
a setting or implement a command.
When you apply power to the fixture, it boots up. After it has booted, the panel
displays the default screen.
The Battery button is used to power up the control panel for setup before mains is
connected to the unit. Battery mode can be disabled in the menu.
The W-DMX indicator shows when wireless DMX is being received, if the optional
wireless module has been fitted.
26 EXO Spot 30 User Manual Rev. A
German Light Products® Control menus and onboard display
DMX control is disabled when the control menus are active.
Display options
The illuminated LCD display lets you change fixture settings. The display has a battery
backup so that you can change the settings before mains is connected to the fixture.
See Chapter 9 for more details.
Using the Control / Settings DMX channel or the fixture’s control panel you can:
Set display modes using the Fixture Settings > Display Mode option:
- On: The display stays on constantly. This setting can be useful when you are
configuring or servicing the fixture.
- Auto: The display will automatically switch off after a few seconds even if the fixture
is not receiving a valid control signal or if it has detected an error.
Invert the display using the Fixture Settings > Display Orientation option, so it is easier to
read if the fixture is hanging upside down.
Display Locking
On the Fixture Settings > Lock menu, you can configure the display to lock after a
period of time to prevent accidental changes to the options.
You can set a custom lock code using the Fixture Settings > Lock > Set Passcode
option. If you do not set a custom code, the default code is 0000.
Manual Control
Using the Manual Control menu you can set fixed values to the fixture’s control
channels, as if it was in DMX control mode 1. This is useful when testing.
LED PWM frequency
The LEDs in the unit are dimmed using Pulse Width Modulation (PWM) which can
sometimes cause flickering on cameras. The Fixture Settings > PWM option allows you
to select different frequencies for the PWM to fix such issues. The higher frequencies
may cause reduced dimming performance.
Fan control
The fixture has internal cooling fans. In a noise critical situation you can slow these
down using the Fixture Settings > Fan Mode option. The normal setting is Regulated
which will adjust the fan speed automatically. If you set the option to Low the fan
speed is kept slow but this may result in the fixture overheating and reducing its output.
The fixture has an additional fan near the lens to clear condensation. You can control
how this fan works using the Fixture Settings > Defog option.
Fixture information
The Information menu in the control panel gives access to items of information from
the fixture’s sensors and memory. You can check temperature sensor readouts, see
total operating hours counters, and see software version number, for example.
EXO Spot 30 User Manual Rev. A 27
www.glp.de Control menus and onboard display
Pan disable / Tilt disable
These options allow you to disable the startup reset movements or disable the drive of
the pan and/or tilt motors. The options are
- Off: Normal motor control
- Reset Disabled: The fixture will not do its power on reset sequence on this motor but
the motor is still controlled. This can be used when a fixture is mounted in a
confined space and would collide with an obstruction if it did the reset sequence.
- Current Disabled: The motor drive function is completely disabled. This is mostly
used for service or diagnostics.
Preset settings and factory defaults
You can store three different versions of option settings using the Service > Service
Advanced > Save Settings menu and load them using the Load Settings > Preset 1-2-3
options. These allow you to quickly set up the fixture in a particular configuration.
Settings are stored after a power off/on cycle and after a reset.
Two options are available in the fixture’s control panel for deleting multiple custom
settings and restoring defaults:
- Service > Default Settings reloads all the fixture’s factory default settings except
DMX address, DMX mode, captured scene, preset settings and offset values. This
option returns the fixture to baseline settings without affecting its basic
configuration in an installation.
- Service > Service Advanced > Factory Backup reloads all the fixture’s factory
default settings including DMX address, DMX mode, and erases all storage. This
option reinitializes the fixture completely and returns to its state when it left the
factory.
Sets overheat
temperature where
shutdown will occur
Fan Mode
Regulated / High / Medium
/ Low
Set fan speed control
Load Settings
Preset 1 / Preset 2 / Preset 3
Press ENTER for 3 sec to
confirm
Lock
Off / On /. Set Passcode
Lock the control panel
Defog
Off / On / Quick
Settings for lens defogging
fan
Battery
On / Off
Disable the battery
operation of the control
panel
MANUAL
CONTROL
Reboot
Press ENTER for 3 sec to
confirm
Manual function control
(DMX Mode 1)
Pan Coarse 0-255
These values can be set
manually or from a DMX
state using Capture Scene
option
Pan Fine 0-255
Tilt Coarse 0-255
Tilt Fine 0-255
Color 1 Cyan 0-255
Color 2 Magenta 0-255
Color 3 Yellow 0-255
Cyan 0-255
Magenta 0-255
10. Control menu layout
EXO Spot 30 User Manual Rev. A 29
www.glp.de Control menu layout
Yellow 0-255
Gobo Wheel 1 0-255
Gobo Wheel 2 0-255
Gobo 2 rotation coarse 0255
Gobo 2 rotation fine 0-255
Shutter 0-255
Dimmer Coarse 0-255
Dimmer Fine 0-255
Frost 0-255
Prism 0-255
Prism rotation 0-255
Focus coarse 0-255
Focus fine 0-255
Zoom 0-255
Control 0-255
Capture Scene
Press ENTER for 3 sec to
capture incoming DMX
state
INFORMATIO
N
Firmware Version
ver x.x
Fixture firmware version
Fixture Details
Serial … xx / RDM … xx
Show fixture serial, RDM
unique ID
Device Life
Total / User
Shows power cycles,
Power Hours, LED Hours
DMX Link Status
Refresh Rate (Hz) / Frame
Length / Mode Length
Details of DMX signal
Temperatures
xxx…
Unit temperatures
Fan Speeds
Fan1 …
Error Log
Xxx
SERVICE
Test All
Running
Press Enter to start test,
Menu or Enter to stop
Test Pan only
Running
Test Tilt only
Running
Test LED only
Running
Test Zoom only
Running
Default Settings
See Note 1 below
Service Advanced
See below for menu
Hold Enter for 6 sec to
enter this menu
FACTORY
MENU
This menu is for use by authorized service technicians only
Note 1: Default Setting will return all options to default except DMX address, Control
Mode. It does not erase captured scene, preset settings or offset values
Default settings are written in BOLD type.
30 EXO Spot 30 User Manual Rev. A
German Light Products® Control menu layout
Menus
Notes
Pan Disable
Off/On
Tilt Disable
Off/On
Units
°C / °F
Offsets
Tilt
xxx
Zoom
xxx
Reset
Counter
Power Hours
Power Cycles
LED Hours
Max Temperature
Temperature Unit
Save Settings
Preset 1
Preset 2
Preset 3
Factory
Backup
See Note 2 below
Service Advanced menu
Hold down Enter for 6 seconds to access this menu.
Note 2: Factory backup will reset all options to default, erase captured scene, erase
preset settings, erase offset values. User Hour counter and Temperature Unit will not be
affected.
EXO Spot 30 User Manual Rev. A 31
www.glp.de DMX control mode overview
DMX Mode 1: Standard
The EXO Spot 30 uses 23 DMX channels.
It provides 16-bit control of pan and tilt,
16-bit dimming and a shutter with
strobe and ramp up/down effects.
Control of the three color wheels, two
gobo wheels, gobo rotation, zoom and
the prism is provided.
You also have control of focus and a
control / settings channel that lets you
configure the feature and adjust
settings remotely via DMX.
Mode 1
Compact
1
Pan 2 Pan fine
3
Tilt
4
Tilt fine
5
Color wheel 1 Cyan
6
Color wheel 2 Magenta
7
Color wheel 3 Yellow
8
Cyan
9
Magenta
10
Yellow
11
Gobo 1
12
Gobo 2
13
Gobo 2 index/rotate
14
Shutter
15
Dimmer coarse
16
Dimmer fine
17
Frost
18
Prism
19
Prism rotation
20
Focus coarse
21
Focus fine
22
Zoom
23
Control
11. DMX control mode overview
The EXO Spot 30 has only one DMX control mode which uses the following DMX
channels
32 EXO Spot 30 User Manual Rev. A
German Light Products® DMX control channel layout tables
Channel
Command
DMX
range
Percent
Default
DMX
Fade
1
Pan
Pan left–right
0
65535
0
100
32767
Fade
2
Pan fine
3
Tilt
Tilt up–down
0
65535
0
100
32767
Fade
4
Tilt fine
5
Color 1 (Cyan)
Position 1 (Open)
0 3 0.0
1.2
0
Snap
Position 1 + 2 (Split Color)
4 7 1.6
2.7
Position 2
8
11
3.1
4.3
Position 2 + 3 (Split Color)
12
15
4.7
5.9
Position 3
16
19
6.3
7.5
Position 3 + 4 (Split Color)
20
23
7.8
9.0
Position 4
24
27
9.4
10.6
Position 4 + 5 (Split Color)
28
31
11.0
12.2
Position 5
32
35
12.5
13.7
Indexing from Open over fixed Colors
to Cyan (full)
36
169
14.1
66.3
Color Bounce from Open over fixed
Colors to Cyan (full) and back, FastSlow
170
214
66.7
83.9
Color Bounce Stop
215
215
84.3
84.3
Invert Color Bounce from Cyan (Full)
over fixed Colors to Open and back,
Slow-Fast
216
255
84.7
100.0
6
Color 2
(Magenta)
Position 1 (Open)
0 3 0.0
1.2
0
Snap
Position 1 + 2 (Split Color)
4 7 1.6
2.7
Position 2
8
11
3.1
4.3
Position 2 + 3 (Split Color)
12
15
4.7
5.9
Position 3
16
19
6.3
7.5
Position 3 + 4 (Split Color)
20
23
7.8
9.0
Position 4
24
27
9.4
10.6
Position 4 + 5 (Split Color)
28
31
11.0
12.2
Position 5
32
35
12.5
13.7
Indexing from Open over fixed Colors
to Magenta (full)
36
169
14.1
66.3
Color Bounce from Open over fixed
Colors to Magenta (full) and back,
Fast-Slow
170
214
66.7
83.9
Color Bounce Stop
215
215
84.3
84.3
Invert Color Bounce from Magenta
(Full) over fixed Colors to Open and
back, Slow-Fast
216
255
84.7
100.0
7
Color 3
(Yellow)
Position 1 (Open)
0 3 0.0
1.2
0
Snap
Position 1 + 2 (Split Color)
4 7 1.6
2.7
Position 2
8
11
3.1
4.3
Position 2 + 3 (Split Color)
12
15
4.7
5.9
Position 3
16
19
6.3
7.5
Position 3 + 4 (Split Color)
20
23
7.8
9.0
Position 4
24
27
9.4
10.6
Position 4 + 5 (Split Color)
28
31
11.0
12.2
Position 5
32
35
12.5
13.7
Indexing from Open over fixed Colors
36
169
14.1
66.3
12. DMX control channel layout tables
DMX Mode 1: Standard
24 DMX Channels
EXO Beam 10 User Manual Rev. A 33
www.glp.de DMX control channel layout tables
to Yellow (full)
Color Bounce from Open over fixed
Colors to Yellow (full) and back, FastSlow
170
214
66.7
83.9
Color Bounce Stop
215
215
84.3
84.3
Invert Color Bounce from Yellow (Full)
over fixed Colors to Open and back,
Slow-Fast
216
255
84.7
100.0
8
Cyan
Cyan color mixing (see note 1)
0
255 0 100
0
Fade
9
Magenta
Magenta color mixing (see note 1)
0
255 0 100
0
Fade
10
Yellow
Yellow color mixing (see note 1)
0
255 0 100
0
Fade
11
Gobo wheel 1
Open
0
8
0.0
3.1
0
Snap
Gobo 1
9
17
3.5
6.7
Snap
Gobo 2
18
26
7.1
10.2
Snap
Gobo 3
27
35
10.6
13.7
Snap
Gobo 4
36
44
14.1
17.3
Snap
Gobo 5
45
53
17.6
20.8
Snap
Gobo 6
54
62
21.2
24.3
Snap
Gobo 7
63
71
24.7
27.8
Snap
Gobo 8
72
80
28.2
31.4
Snap
Gobo 1 shaking
81
92
31.8
36.1
Snap
Gobo 2 shaking
93
104
36.5
40.8
Snap
Gobo 3 shaking
105
116
41.2
45.5
Snap
Gobo 4 shaking
117
128
45.9
50.2
Snap
Gobo 5 shaking
129
140
50.6
54.9
Snap
Gobo 6 shaking
141
152
55.3
59.6
Snap
Gobo 7 shaking
153
164
60.0
64.3
Fade
Gobo 8 shaking
165
176
64.7
69.0
Fade
Gobo wheel spin stop
177
177
69.4
69.4
Gobo wheel spin clockwise fast >
slow
178
216
69.8
84.7
Gobo wheel spin stop
217
217
85.1
85.1
Fade
Gobo wheel spin counterclockwise
slow > fast
218
255
85.5
100
Fade
12
Gobo wheel 2
Open 0 4
0.0
1.6
0
Snap
Gobo 1 indexed
5 9 2.0
3.5
Snap
Gobo 2 indexed
10
14
3.9
5.5
Snap
Gobo 3 indexed
15
19
5.9
7.5
Snap
Gobo 4 indexed
20
24
7.8
9.4
Snap
Gobo 5 indexed
25
29
9.8
11.4
Snap
Gobo 6 indexed
30
34
11.8
13.3
Snap
Gobo 1 rotate
35
39
13.7
15.3
Snap
Gobo 2 rotate
40
44
15.7
17.3
Snap
Gobo 3 rotate
45
49
17.6
19.2
Snap
Gobo 4 rotate
50
54
19.6
21.2
Snap
Gobo 5 rotate
55
59
21.6
23.1
Snap
Gobo 6 rotate
60
64
23.5
25.1
Snap
Gobo 1 shake and index
65
74
25.5
29.0
Snap
Gobo 2 shake and index
75
84
29.4
32.9
Snap
Gobo 3 shake and index
85
94
33.3
36.9
Snap
Gobo 4 shake and index
95
104
37.3
40.8
Snap
Gobo 5 shake and index
105
114
41.2
44.7
Snap
Gobo 6 shake and index
115
124
45.1
48.6
Snap
Gobo 1 shake and rotate
125
134
49.0
52.5
Snap
Gobo 2 shake and rotate
135
144
52.9
56.5
Snap
Gobo 3 shake and rotate
145
154
56.9
60.4
Snap
Gobo 4 shake and rotate
155
164
60.8
64.3
Snap
Gobo 5 shake and rotate
165
174
64.7
68.2
Snap
Gobo 6 shake and rotate
175
184
68.6
72.2
Snap
34 EXO Spot 30 User Manual Rev. A
German Light Products® DMX control channel layout tables
Gobo wheel spin stop
185
185
72.5
72.5
Snap
Gobo wheel spin clockwise fast >
slow
186
219
72.9
85.9
Fade
Gobo wheel spin stop
220
220
86.3
86.3
Snap
Gobo wheel spin counterclockwise
slow > fast
221
255
86.7
100
Fade
EXO Beam 10 User Manual Rev. A 35
www.glp.de DMX control channel layout tables
13
Gobo 2
Index/Rotate
when ch. 12 = “indexed”:
0
Fade
Gobo index 0-360°
0
255 0 100
when ch. 12= “rotate”:
0
Fade
Gobo rotation stop
0 0 0
0
Gobo rotation clockwise fast > slow
1
127
0.4
49.8
Gobo rotation stop
128
128
50.2
50.2
Gobo rotation counterclockwise
slow > fast
129
255
50.6
100
14
Shutter
Shutter closed
0 4 0
1.6
0
Snap
Single flash when change on dimmer
channel
5 9 2.0
3.5
Sync ramp up slow–fast
10
39
3.9
15.3
Sync ramp down slow–fast
40
69
15.7
27.1
Sync ramp up-down slow–fast
70
99
27.5
38.8
Sync double flash (slow–fast)
100
129
39.2
50.6
Random strobe pixel (slow–fast)
130
159
51.0
62.4
Random strobe all (slow–fast)
160
199
62.7
78.0
Sync strobe (1 Hz–10 Hz)
200
250
78.4
98.0
Shutter open
251
255
98.4
100
15
Dimmer
Intensity 0-100%
0
65535
0
100
0
Fade
16
Dimmer fine
17
Frost
Frost 0 – 100%
0
255 0 100
0
Fade
18
Prism
No prism
0 3 0
1.2
0
Snap
Prism inserted
4
255
1.6
100
19
Prism rotation
No prism
0 3 0
1.2
Fade
Variable position from 0-360°
4
127
1.6
49.8
Rotation stop
128
128
50.2
50.2
Rotation clockwise fast > slow
129
191
50.6
74.9
Rotation stop
192
192
75.3
75.3
Rotation counterclockwise slow >
fast
193
255
75.7
100
20
Focus
Focus 0 > 100%
0
65535
0
100
32767
Fade
21
Focus fine
22
Zoom
Zoom 0 > 100%
0
255 0 100
128
Fade
23
Control /
Settings
No function
0 9 0.0
3.5
0
Snap
Dimmer curve: Extra-soft (3s hold)
10
15
3.9
5.9
Dimmer curve: Linear (3s hold)
16
21
6.3
8.2
Display mode: Auto (3s hold)
22
27
8.6
10.6
Display mode: On (3s hold)
28
33
11.0
12.9
Display mode: Off (3s hold)
34
39
13.3
15.3
Display orientation: Normal (3s hold)
40
45
15.7
17.6
Display orientation: Inverted (3s hold)
46
51
18.0
20.0
No DMX: Blackout (3s hold)
52
57
20.4
22.4
No DMX: Hold (3s hold)
58
63
22.7
24.7
No DMX: Stand-alone (3s hold)
64
69
25.1
27.1
Fan mode: Regulated (3s hold)
70
75
27.5
29.4
Fan mode: High (3s hold)
76
81
29.8
31.8
Fan mode: Medium (3s hold)
82
87
32.2
34.1
Fan mode: Low (3s hold)
88
93
34.5
36.5
Position feedback: Off (3s hold)
94
99
36.9
38.8
Position feedback: On (3s hold)
100
105
39.2
41.2
No function
106
117
41.6
45.9
Tilt inversion: Off (3s hold)
118
123
46.3
48.2
Tilt inversion: On (3s hold)
124
129
48.6
50.6
36 EXO Spot 30 User Manual Rev. A
German Light Products® DMX control channel layout tables
Pan inversion: Off (3s hold)
130
135
51.0
52.9
Pan inversion: On (3s hold)
136
141
53.3
55.3
Zoom inversion: Off (3s hold)
142
147
55.7
57.6
Zoom inversion: On (3s hold)
148
153
58.0
60.0
Defog: Off
154
159
60.4
62.4
Defog: On
160
165
62.7
64.7
Defog: Quick
166
171
65.1
67.1
Load Settings Preset1
172
177
67.5
69.4
Load Settings Preset2
178
183
69.8
71.8
Load Settings Preset3
184
189
72.2
74.1
PWM 600 Hz (5s hold)
190
195
74.5
76.5
PWM: 2200 Hz (5s hold)
196
201
76.9
78.8
PWM: 3000 Hz (5s hold)
202
207
79.2
81.2
PWM: 4800 Hz (5s hold)
208
213
81.6
83.5
PWM: 9600 Hz (5s hold)
214
219
83.9
85.9
PWM: 25 kHz (5s hold)
220
225
86.3
88.2
No function
226
231
88.6
90.6
Return to default settings
232
237
91.0
92.9
Reset Pan/Tilt (3s hold)
238
243
93.3
95.3
Reset Head (3s hold)
244
249
95.7
97.6
Reset All (3s hold)
250
255
98.0
100
Note 1: When CMY channels 8-10 are above zero, they take precedence over the
static color wheel CMY controls on channels 5-7.
To set fixed color on channel 5, ensure channel 8 is at zero.
To set fixed color on channel 6, ensure channel 9 is at zero.
To set fixed color on channel 7, ensure channel 10 is at zero.
EXO Beam 10 User Manual Rev. A 37
www.glp.de Service
Warning! There are no user-serviceable parts inside the fixture. Opening the
fixture can compromise its IP65 rating and cause damage that is not covered
by the product warranty. Any service operation that requires removal of a
cover must be performed by a professional service technician with the tools,
skills, and personal protective equipment to maintain high-powered lighting
equipment safely and efficiently.
13. Service
Cleaning
EXO Spot 30 fixtures require occasional cleaning to prevent the buildup of dust, dirt, and
residue from atmospheric effects. Failure to keep the fixture clean will significantly reduce
light output and may cause heat buildup and damage that is not covered by the product
warranty. Regular cleaning will ensure maximum performance and reliable operation.
The cleaning schedule depends on the operating environment. Check fixtures regularly for
signs of dirt buildup.
You can clean the fixture using a soft cloth slightly dampened with a household or
automotive glass cleaning product. Do not apply pressure to the clear front or display on
the back of the fixture, as you may scratch these surfaces.
Use the tilt lock mechanism to hold the head in a vertical position for easier cleaning.
GLP Service and Support
Contact information for the nearest GLP Service and Support is available online at
www.glp.de/en/service, by email at info@glp.de, or by telephone at the following
numbers:
● GLP Germany: +49 (7248) 927 19-55
● GLP N. America: +1 818 767-8899
● GLP UK: +44 1392 690140
● GLP Asia: +852 (3151) 7730
● GLP Nordic: +46 737 57 11 40
38 EXO Spot 30 User Manual Rev. A
German Light Products® Technical specifications
14. Technical specifications
Optics
Light source: Advanced 90W White LED
Lifetime: 20 000 hrs. approx. to > 70% luminous output
Luminous flux @ 7° zoom: 107100 lux @ 3 m, 38556 lux @ 5 m
Beam angle (half peak): 7° - 30°
Control
Control systems: DMX, RDM, Manual setting
DMX channel footprint: 24
Setting and addressing: Onboard control panel with LCD display, RDM
DMX compliance: USITT DMX512
RDM compliance: ANSI/ESTA E1.20
Pan range: 540°, 16 bit resolution
Tilt range: 258°, 16 bit resolution
Installation
Options: Stand on horizontal surface, suspended using truss mount brackets
Operating position: Any
Minimum distance to combustible materials: 0.5 m (20 in.)
Minimum distance to illuminated surfaces: 0.5 m (20 in.)
Installation environment: Temporary or permanent indoor installation, temporary outdoor
installation
Secondary attachment: Slot for safety cable attachment
Electrical
AC mains power: 100-240 V nominal, 50/60 Hz
Power supply unit: Auto-ranging electronic switch mode
Maximum power consumption, LED at 100% output: 295 W
Maximum permitted number of fixtures daisy-chained to power
6 x EXO Spot 30 total @ 100-120 V, 60 Hz
12 x EXO Spot 30 total @ 200-240 V, 50 Hz
Connections
AC mains power in and thru (out): Neutrik powerCON TRUE1 with sealing cap
Control data in and thru (out): Neutrik 5-pin XLR with sealing cap
Construction
Ingress protection rating: IP65
Fixture housing: Aluminum, plastic
Color: Black
Thermal
Cooling: Fan, Convection
Minimum ambient temperature: -10° C (14° F)
Maximum ambient temperature: 40° C (104° F)
EXO Beam 10 User Manual Rev. A 39
www.glp.de Technical specifications
Included items
Power cable with Neutrik powerCON TRUE1 mains input plug
Dimensions and weight
Length: 368mm / 14.5 ins.
Width: 380 mm / 15.0 ins.
Height: 605 mm / 23.8 ins.
Weight: 25.9 kg (57 lbs.)
40 EXO Spot 30 User Manual Rev. A
German Light Products® Dimensions
15. Dimensions
All dimensions are in millimeters
EXO Beam 10 User Manual Rev. A 41