All brand and product names are trademarks, registered trademarks or service marks of their respective holders.
Installation Manual
NETWORK FISH FINDER
Model DFF3-UHD
A Word to the Owner of the DFF3-UHD
Congratulations on your choice of the FURUNO DFF3-UHD Network Fish Finder. The DFF3-UHD is a network fish finder designed for use with the NavNet TZtouch3 (TZT9F/12F/16F/19F, Ver. 3.01 or higher) and
NavNet TZtouch2 (TZT2BB only, Ver.9.01 or higher). Please carefully read and follow the recommended
procedures for installation and maintenance. Thank you for considering and purchasing FURUNO.
Operational Cautions
• A separate power supply is required. Take the power from the ship's mains via the ship's switchboard.
• The DFF3-UHD is not turned off when the multi function display is powered off. The DFF3-UHD's standby
power is 6.2 W, so turn it off from the ship’s switchboard when it is not in use.
• DFF3-UHD does not support the Bottom Discrimination, RezBoost, or ACCU-FISH.
• Do not transmit with the transducer out of water, to prevent damage to the transducer.
• Use the multi function display to change the program version of the power amp. Contact FURUNO for
information on how to upgrade program version.
• When using two types of transducers, set them from [Fishfinder]-[Transducer Setup]-[Transducer Setup][Type] of the NavNet TZtouch3 and NavNet TZtouch2. Because the equipment has only one TDID port,
two TDIDs cannot be read.
• The following concern acts as our importer in Europe, as defined in DECISION No 768/2008/EC.
- Name: FURUNO EUROPE B.V.
- Address: Ridderhaven 19B, 2984 BT Ridderkerk, The Netherlands
• The following concern acts as our importer in UK, as defined in SI 2016/1025 as amended SI 2019/470.
- Name: FURUNO (UK) LTD.
- Address: West Building Penner Road Havant Hampshire PO9 1QY, U.K.
Safety Instructions
The installer must read the safety instructions before attempting to install the equipment.
WARNING
CAUTION
Warning, Caution
WARNING
Do not disassemble or modify the
equipment.
Fire, electrical shock or serious injury
can result.
Use the proper fuse.
Use of a wrong fuse can damage the
equipment and may cause fire.
12VDC24VDC
7.5 A7.5 A
Indicates a potentially hazardous situation which, if not avoided,
could result in death or serious injury.
Indicates a potentially hazardous situation which, if not avoided,
could result in minor or moderate injury.
Prohibitive Action
Mandatory Action
CAUTION
Observe the following compass safe
distance to prevent interference to a
magnetic compass:
With regards to CE/UKCA declarations, please refer to our website (www.furuno.com) for further information about RoHS conformity declarations.
Disclosure of Information about China RoHS
With regards to China RoHS information for our products, please refer to our website
(www.furuno.com).
Installation
Select the mounting location considering the following points.
• Locate the unit away from areas subject to water splash.
• Select a location that is well ventilated.
• Observe the compass safe distances shown on page 1.
• Leave the sufficient service clearance around the unit.
2
Procedure
Tabletop mount
Bulkhead mount
OK
NO
POWER
EXT-KP
NETWORK
Transducer
Grounding terminal
Transducer
Seal nut
Super gland
1. Drill four pilot holes in the bulkhead (or tabletop) for the self-tapping screws.
2. Screw two self-tapping screws (φ5x20) into the pilot holes for upper, leave 5 mm protruding.
3. Set unit onto the screws and fasten them.
4. Tightly fasten the other two screws to fix the unit in place.
Note: For mounting on a bulkhead, the connectors must face downward.
Wiring
Wiring Outline
The figure below shows the inserting position of each cables for the DFF3-UHD. Refer to the interconnection
diagram for details.
Inserting position of cables
3
Procedure
150
150
30
Seal assemblySeal assembly
SealSeal
ClawClaw
Seal nutSeal nut
Procedure
1. Twist conductors.
2. Insert terminal opener and push.
3. Insert a conductor into hole.
4. Release the terminal opener.
5. Pull the core to confirm it is
correctly inserted.
Push
Terminal
opener
WAGO
Connector
Core
Twist
1. Remove the cover.
2. Unfasten four screws to remove the chassis cover.
[Transducer cable wiring]
3. Fabricate the transducer cable(s) as shown below.
Fabricate the cables for both the high and low frequencies. For a CHIRP transducer, fabricate the ID
signal cores for both the high and low frequencies.
150
150
6
Sheath
Wrap the shield onto the sheath.
30
Vinyl tape
Clamp here.
Single frequency transducer cable
Braided shield
Drain wire
6
Vinyl tape
Clamp here.
CHIRP transducer cable
*:Cut the purple signal core.
Note: When the previous CHIRP transducer cable (with 4 drain wires and braided shield) is used,
turn back the shield onto the sheath and fix with vinyl tape.
4. Unfasten the seal nut on the cable entry for transducer cable.
5. Pass the seal nut, claw and seal onto the transducer cable, in that order.
Core*
6. Push the seal assembly into the seal nut, then tighten the super gland.
7. Remove the WAGO connectors from the PCB, then attach the transducer cable to the connector.
8. Clamp the braided shield with a cable clamp.
4
9. Attach the WAGO connector to the PCB.
Clamp the
shield
LF
HF
LF
HF TDID
KP
KP
Source
Source
Transducer
cable
LFHF
External KP
signal cable
CHIRP
transducer
Fix the
cable end
LAN
LAN
Cable
LAN
LAN
Cable
Make loop
Make loop
TDID
For two sets of single frequency
transducers
For CHIRP
transducer
External KP
signal cable
External KP signal cable (local supply)
VCTF0.75x4C
6
150150
Sheath
φ6.5
㻌㼠㼛㻌
φ12.5
Note: For previous CHIRP transducer cable, connect the drain wires to the connector and clamp
the shield.
[LAN cable and external KP signal cable wiring]
10. Connect the LAN cable to the LAN connector.
As shown in the above figure, make a loop in the cable (approx. 10mm diameter), then connect the
cable.
11. Fasten the seal nut to fix the transducer cable.
The torque shall be 2.0 Nm and the gap between the seal nut and the super gland shall be approx. 3
mm.
12. Fabricate the external KP signal cable as shown below. (core size 0.75 sq, outer dia 7.6 approx.)
13. Pass the cable through the seal nut and seal assembly, like you did with the transducer cable.
14. Push the seal assembly into the seal nut, then tighten the super gland.
15. Remove the WAGO connector from the PCB and connect it to the external KP signal cable.
16. Connect WAGO connector to the PCB.
17. Tighten the seal nut to fasten the cable.
18. Attach the EMI core (GRFC-8, supplied) to the power cable near the super gland to prevent noise (see
figure below).
19. Attach the ground wire (IV-1.25sq, local supply) to the ground terminal with a crimp-on lug (M3, local
supply) to prevent interference.
20. Reattach the chassis cover.
21. Reattach the cover.
EMI core
10 mm
External KP
signal cable
5
For networking two units
ON OTAX KHS82
14
0J
5
6
8
23
7
When two units are installed,
turn on switch #2 on one unit.
DIP switch䠄S1䠅
㻿㼀㻭㼀㼁㻿㻌 㻱㻾㻾㻻㻾
A maximum of two DFF3-UHD units can be connected on the same network. When two units are
installed, change the DIP switch setting on one unit to assign a unique IP address on that unit.
Turn ON the #2 switch of DIP switch S1 as shown in the figure below.
Operation Check
For NavNet TZtouch3 and NavNet TZtouch2, the DFF3-UHD is powered on/off from the ship’s switchboard.
The STATUS LED and ERROR LED on the bottom of the DFF3-UHD lights or blinks according to equipment
state, as described in the table below.
LED TypeSTATUSERRORMeaning
LED State
Blinking every two seconds
Blinking every 0.4 seconds
Off
Off
Normal operation
Transducer settings at NavNet
device not properly set.
Off
Lit continuouslyCommunication error with
NavNet device or internal fan
error (see “Troubleshooting”
about how to solve the problem).
LED Position
6
Troubleshooting
The table below provides basic troubleshooting procedures which the user may follow to restore normal operation. If you cannot restore normal operation, do not check inside unit. Have a FURUNO dealer check the
equipment
.
ProblemReason
Cannot turn on power.• The power cable is disconnected or damaged. Check the
power cable and if it damaged, replace it.
• Check the ship’s mains and check if the switchboard is
turned on.
• Check the fuse on the power cable. If the fuse has blown,
find the cause then replace it.
No echo appears but fixed
range scale appears.
Sensitivity is low.• Gain setting is too low. Raise the gain.
ERROR LED turns on.• Disconnect the Power cable and LAN cable.
• The sensor cable is disconnected or damaged.
Check the cable and reconnect or replace it as necessary.
• Marine life is adhering to the transducer face. Clean the
transducer face.
• Vessel is in heavily sedimented water.
• Connect the Power cable and LAN cable.
• Contact your local dealer for advice when the problem
cannot be solved.
The below shows the transducers that can be connected.
Note: CHIRP transducers (dual frequency) are the products of AIRMAR Technology Corporation.
Licensed Software
This product includes software licensed under BSD-3-Clause and others. Please refer to the following for
details on the terms of the software.
I
ntel-socfpga-hwlib
Copyright 2013-2020 Intel Corporation. All Rights Reserved.
Redistribution and use in source and binary forms, with or without modification, are permitted provided that
the following conditions are met:
1. Redistributions of source code must retain the above copyright notice, this list of conditions and the
following disclaimer.
2. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the
following disclaimer in the documentation and/or other materials provided with the distribution.
3. Neither the name of the copyright holder nor the names of its contributors may be used to endorse or
promote products derived from this software without specific prior written permission.
THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS"AND
ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE
DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR
ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES
(INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON
ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING
NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN
IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
Altera-SoCFPGA-HardwareLib-MPL
Altera MPL preloader, configured for use with SDMMC/Connectal. (The initial commit is the unmodified
sourcecode from Altera)
The original source was extracted from: altera/14.1/embedded/examples/software/Altera-SoCFPGAHardwareLib-MPL.tar.gz and has BSD copyright with the additional restriction: "This software may only be
used to run on Altera products, or to program Altera devices."
All subsequent edits by Cambridgehackers are under the same copyright.
8
PACKING LIST
02HA-X-9851
-0
DFF3-UHD
N A M E
O U T L I N E
DESCRIPTION/CODE №
Q'TY
1/1
ユニット
UNIT
ネットワーク魚探
NETWORK FISH FINDER
DFF3-UHD
000-038-529-00
1
工事材料
INSTALLATION MATERIALS
ケーブル(組品)
CABLE ASSEMBLY
FRU-3P-FF-A002M-001
000-197-092-10
1
ケーブル(組品)LAN
LAN CABLE ASSEMBLY
MOD-Z072-050+
001-167-890-10
1
工事材料袋詰
INSTALLATION MATERRIALS
CP02-09901
001-621-550-00
1
図書
DOCUMENT
装備要領書(英)
INSTALLATION MANUAL (EN)
IME-20410-*
000-199-256-1*
1
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)
A-1
C2041-Z01-A
D-1
3/Feb/2022 H.MAKI
TEMP
S-
1
27/Sep/2023 H.MAKI
34GND
2
XID
SHIELD
1
TB4
6
NC
XDR_HF(+)
5
4
NC
SHIELD
3
2
NC
XDR_HF(-)
1
TB3
XDR_LF(+)
5
4
NC
SHIELD
3
2
NC
XDR_LF(-)
43
旧送受波器ケーブルの端末処理
FABRICATION FOR PREVIOUS TRANSDUCER CABLE
または OR
MULTI FUNCTION DISPLAY
マルチファンクションディスプレイ
TZT9F/12F/16F/19F
HUB-101
イーサネットハブ
ETHERNET HUB
RJ45
8
MOD-Z072,5m
TZT2BB
(2/10m *2)
*1
TB2
1
WHT
シロ
BRN
チャ
ORG
ダイ
DRAIN
BLUアオ
DRAIN
BLKクロ
(キYEL)
BLU/WHTアオ/シロ
DRAIN
BLK/WHTクロ/シロ
DFF3-UHD
ネットワーク魚探
相互結線図
NETWORK FISH FINDER
INTERCONNECTION DIAGRAM
TITLE
NAME
名 称
02-180-1101-0
REF.No.
kg
IV-2sq.
RJ45
8
J2
ネットワーク魚探
NETWORK SOUNDER
DFF3-UHD
02P64211B
TRIG_IN_P
TRIG_IN_N
TRIG_OUT_P
TRIG_OUT_N
XDR_CHECK(+)
(+)J1SHIELD
7.5A
123
アカ RED
(-)
アオ BLU
3
(+)
CON9
AC/DC POWER
AC/DC電源
ユニット
CON1
123
SUPPLY UNIT
2
6
(-)
*2
PR-241
GNDHC
TB1
1234567
*1
VCTF0.75x4C,10m MAX.
外部KP
EXTERNAL KP
XDR_CHECK(-)
SHIELD
TEMP
XID
SHIELD
TB4
NC
XDR_HF(+)
NC
SHIELD
NC
XDR_HF(-)
TB3
XDR_LF(+)
NC
SHIELD
NC
XDR_LF(-)
TB2
WHT
34GND
2
1
6
5
4
3
2
1
5
4
3
2
1
シロ
BRN
チャ
ORG
ダイ
DRAIN
BLUアオ
BLKクロ
BLU/WHTアオ/シロ
BLK/WHTクロ/シロ
*2
12m
*3
送受波器
TRANSDUCER
DRAWN
S.HAN
27/Sep/2023
T.YAMASAKI
C2041-C01- C
27/Sep/2023
CHECKED
APPROVED
DWG.No.
SCALEMASS
1
FRU-3P-FF-A002M-001,2m
12/24 VDC
A
TPYC-1.5
100-230VAC
1φ,50-60Hz
NOTE
2: OPTION.
注記
1)造船所手配。
2)オプション。
3)延長ケーブルC44-02(オプション)で50mまで延長可。
B
C
1: SHIPYARD SUPPLY.
3: EXTENSION CABLE C44-02 (OPTION) ENABLES EXTENSION UP TO 50m.
9-52 Ashihara-cho,
A:FEB
2022
.
D:JUN.05, 2024
Pub. No.
(
)
Nishinomiya, 662-8580, JAPAN
・FURUNO Authorized Distributor/Dealer
All rights reserved.
REFU
DFF3-UHD
Printed in Japan
IME-20410-D
0 0 0 1 9 9 2 5 6 1 4