Furman Sound PM-PRO, PM-PRO-E User Manual

FURMAN
FURMAN
FURMAN FURMAN
PRO SERIES
Power Conditioner/Monitor
MODELS PM-PRO, PM-PRO-E
Owner's Manual
3-9844 © 1998 FURMAN SOUND, INC. 960112-1407
2 PM-PRO POWER CONDITIONER/MONITOR
Note: Where different, PM-PRO-E specs are in parentheses.
Current rating:
Input Voltage Range: Meter Accuracy:
Spike Protection Modes: Clamping Voltage, all modes:
Response time: Maximum surge current: Maximum spike energy: Noise attenuation:
Dimensions:
Weight: Construction:
Power consumption: Safety Information:
20 Amps, 2400 Watts at 120 VAC (16 Amps, 3600 Watts at 230 VAC 0 to 280 VAC without damage Voltmeter:+2(+4) VAC; Ammeter:+2 amps, calibrated with trimpot adjustments Line to neutral, neutral to ground, line to ground TVSS rating 400V peak, L-N, L-G, N-G, tested to UL 1449 (TVSS rating 400V peak, L-N; 680V peak, L-G, N-G 1 nanosecond 11,000 amps (8 x 20mS pulse) 550 joules total Differential mode: Greater than 40 dB; Common mode: greater than 60 dB; both 1 to 200 MHz
1.75" (4.45 cm) H x 19" (48.25 cm) W x 8" (25 cm) D. 6 lbs. (2.7 kg). Steel chassis, zinc chromate plating; brushed and black anodized aluminum front panel; glass epoxy printed circuit boards. 32 Watts PM-Pro: UL listed. CUL listed. PM-PRO-E: CE
Options:
"-G" Suffix (PM-PRO only): provides "super spec", isolated ground 120V outlets for special applications. Please consult factory before ordering to determine suitability in your application.
The Furman PM-PRO is manufactured in the U.S.A.
FURMAN
FURMAN
FURMANFURMAN
Furman Sound, Inc.
1997 South McDowell Blvd.
Petaluma, California 94954-6919
Phone: (707) 763-1010
Fax: (707) 763-1310
Web: http://www.furmansound.com
E-Mail: info@furmansound.com
PM-PRO POWER CONDITIONER/MONITOR 3
g
Safety Information
To obtain best results from your Furman PM-PRO, please be sure to read this manual carefully before using it.
WARNING: To reduce the risk of electrical shock, do not expose this equip­ment to rain or moisture. Dangerous high voltages are present inside the enclosure. Do not remove the covers. There are no user serviceable parts inside. Refer servicin
Important Safety Instructions
to qualified personnel only.
The lightning flash with arrowhead symbol, within an equi­lateral triangle, is intended to alert the user to the presence of uninsulated dangerous voltage within the product's enclo­sure that may be of sufficient magnitude to constitute a risk of electric shock.
Please read prior to installation
1. Please read and observe all of the safety and operating instructions before the PM-PRO is operated. Retain these instructions for future reference.
2. The PM-PRO should not be used near water -- for example, near a bathtub, washbowl, kitchen sink, laundry tub, in a wet basement, near a swimming pool, etc.
3. The PM-PRO should be situated so that its location and position do not interfere with its proper ventilation. For example, the PM-PRO must not be placed on a rug, bed, sofa, or similar surface which impedes airflow across the chassis.
4. Do not place the PM-PRO near heat sources such as radiators, heat registers, stoves, or other appliances that produce heat.
5. The PM-PRO should only be connected to a 120 VAC, 60 Hz, 20 amp grounded electrical outlet. Outlets wired for 20 amps may be identified by the T-shaped socket opening that accepts the perpen­dicular blades of the PM-PRO's power plug. If you don't have a 20 amp outlet available, have one in­stalled by a qualified electrician. Do not defeat the ground or polarization of the power plug.
6. Route the power cord and other cables so that they are not likely to be walked on, tripped over, or stressed. Pay particular attention to condition of cords and
4 PM-PRO POWER CONDITIONER/MONITOR
cables at plugs, and the point where they exit from the PM-PRO. To prevent risk of fire or injury, damaged cords and cables should be replaced immediately.
7. Clean the PM-PRO with a damp cloth only. Do not use solvents or abrasive cleaners. Never pour any liquid on or into the PM-PRO.
8. When left unused for a long period of time, the power cord of the PM-PRO should be unplugged from the outlet.
9. The PM-PRO should be serviced by qualified service personnel when: a. The power supply cord or the plug has been frayed, kinked, or cut.
b. Objects have fallen or liquid has spilled into the unit. c. The PM-PRO has been exposed to rain or other moisture. d. The PM-PRO does not appear to operate normally or exhibits a marked change in performance. e. The PM-PRO has been dropped, or the enclosure damaged.
10. The PM-PRO requires that a safety ground be present for proper operation.
Any attempt to operate the PM-PRO without a safety ground is considered im­proper operation and could invalidate the warranty.
11. There are no user-serviceable parts in the PM-PRO. Refer servicing to qualified
service personnel only.