Fulham EliteControl CTBRCB02JM02 Installation Instructions Manual

Page 1
15
INSTALLATION INSTRUCTIONS
E498 565
Important Safety Instructions
When using electrical equipment and this lighting device basic safety precaution should be followed at all times including but not limited to the following:
COMPLIANT
Input Voltage / Frequency Input Current Input Power Standby Power Maximum Load RFI / EMI RF Communlaction Type Input Surge Protection Transmission Range Dimming Controller Type
Potting/Degree of Fill
120-277VAC (+/- 10%), 50-60Hz 5A Max.
600W (Max.) <1W Max 600W @ 120-277 VAC FCC PART 15A NONCONSUMER, EN 55015
2.4GHz Bluetooth mesh
Line-Nuetral 6kV 160ft.(50m) Bluetooth mesh (SIG Compllant)
YES/Full
eliteBlue
order@fulham.com
www.fulham.com
Page of 1 2
20 - Rev 18 818 A
Page 2
INSTALLATION INSTRUCTIONS
NOTE:
1. Driver has two (2) mounting tabs with a round hole in each.
2. Fasten a screw through the mounting tab if mounted on a flat surface.
E498 565
15
COMPLIANT
RST
GRAY ( - Dimming 0-10VDC)
GRN/ YLW( GND)
INPUT SIDE LENGTH OUTPUT SIDE LENGTH
NOTE:
1. The unit must be installed by a licensed electrician.
WHITE
BLACK
GRAY (-)
2
BLACK 12.4"[315mm] RED 12.4"[315mm]
WHITE 12.4"[315mm] BLUE 12.4"[315mm]
PURPLE 12.4"[315mm]
GRAY 12.4"[315mm]
17.3"[440mm]
GRN/YLW 12.4"[315mm]
INPUT OUTPUT
0-10V
DIMMING
Ø
order@fulham.com
www.fulham.com
Page of 2 2
20 - Rev 18 818 A
Loading...