Fulgor F6GRT366S1 Weight and Measures

36” Gas Ranges Top 600 SERIES
Weight & Dimensions
7” (17,9)
2” (5)
2” (5)
PRODUCT DIMENSIONS
36” Wide Rangetop Models
35 3/4” (91,0)
36” (91,4)
29 1/2” (75,1)
27 3/8” (69,7)
min. 24” (61) max. 25 5/8” (65)
2” (5)
7” (17,9)
2” (5)
7” (17,9)
10” (25,5)
16 3/8” (41,5)
CUTOUT REQUIREMENTS
The surface of the entire back wall above the range and below the hood must be covered with a noncombustible material.
*Consult local code for exact location requirements.
OPENING WIDTH A B
Rangetop 36” 36" (91.4) 30 3/8 (77.1)
Note: Clearances from non-combustible materials are not
part of the ANSI Z21.1 scope and not certied.
Clearances to non-combustible materials must
conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54.
ADDITIONAL CLEARANCES:
For island installation, maintain 2-½ in. minimum from cutout to back edge of countertop and 3 in. minimum from cutout to side edges of countertop (see top view). For island installation, 12” (30.5 cm) minimum clearance back of rangetop to combustible rear wall above countertop. The island installation is and not certifi ed.
not part of
the ANSI Z21.1 scope
FLUSH ISLAND INSTALLATION
BACK
min 3” (7.6) min 3” (7.6)
min 2 1/2” (6.3)
max 13” (33)
min 18” (45,7)
Minimum clearances:
Above cooking surface (above 36” [91.4 cm])
Sides - 6” (15.2 cm)
Within 6” (15.2 cm) side clearance, wall cabinets no
deeper than 13” (33.0 cm) must be minimum 18” (45.7 cm) above cooking surface
Wall cabinets directly above product must be a minimum (122 cm) above cooking surface.
of 48”
Rear - 0” with 9 ” backguard; 0” with non-combustible
rear wall.
Below cooking surface (36” [91.4 cm] and below)
Install with zero clearance between adjacent combustible construction below the cooking surface and the back and sides of the appliance.
min 48” (122) Minimum to Combustibles
A
min 30” (76,2) to bottom of ventilation hood
PACKAGING 36
DIMENSION
35 3/4” (91, 0)
W D H
lb /
inch
lb 55 Kg
122
38"3/4 32"1/8 13"3/8
K mm
984
817 340
g /
27 3/8” (69,7)
min 6” (15,2) min 6” (15,2)
Electrical and Gas
connections
in this area
36” Gas Ranges Top 600 SERIES
Weight & Dimensions
INSTALLATION WITH SEPARATOR SHEET INSTALLATION WITHOUT SEPARATOR SHEET
7 1/2”
(19,2)
4 5/8” (11,6)
min 24”
max 25 1/2” (65)
7
HOLE FOR GAS 3 ½ ” (9)
2 3/4” (7, 0 )
min 24” (61)
)
9
7,
1
(
A
5” (128)
1 3/4” ( 4,5)
4 7/8” (12,5)
max 25 1/2” (65)
7, 9)
1
(
7”
2
(
5
)
2” (5)
A
)
5
(
2
2” (5) 2” (5)
2” (5)
1 3/4” ( 4,5)
min 24” (61)
max 25 1/2” (65)
B
CUTOUT FOR FIXING BRAKETS
A
max 25 1/2” (65)
min 24” (61)
EMPTY SPACE
2” (5)
A